Design of Column Base

Project = Vijaya Mall


RFS = 767
Column number = C1

Working Forces P = -120.0 kN


M11 = 20.0 kN-m
M22 = 10.0 kN-m
V1 = 40.0 kN
V2 = 20.0 kN
Governing case = Wind load case
Column size Bc = 200.0 mm
Dc = 450.0 mm
Grade of Concrete Fck = 25.0 Mpa
Assumed size of Bolts = 20.0 mm
Edge type For rolled sawn or planed edge
Minimum Edge distance = 37.0 mm
Distance from column face = 100.0 mm
Minimum size of plate subjected to minimum edge distance
Bp = 474.0 mm
Dp = 724.0 mm
Assumed size of Base plate
Base Plate size Bp = 450.0 mm
Dp = 600.0 mm

Bearing Pressure under base plate


P/A = -0.4 N/mm2
M11/Z = 0.7 N/mm2
M22/Z = 0.5 N/mm2
= 0.8 N/mm2
OK
Minimum size of pedastal
B = 550.0 mm
D = 700.0 mm

Thickness of base plate


Cantilever projections of the plate are along "B" = 125.0 mm
Cantilever projections of the plate are along "D" = 75.0 mm
Permissible bending stress = 165.0 N/mm2

Along the B
The bearing pressure at edge = 0.0 N/mm2
At column face = -0.2 N/mm2
Moment at column face = -328.6 N-mm/mm
Required thickness of plate = #NUM! mm

#NUM!
Provided base plate thickness = 20.0 mm
Number of stiffener = 2.0
Thickness of stiffener plate = 16.0 mm
Depth provided = 500.0 mm
Neutral axis depth Yb = 158.6 mm
Yt = 361.4 mm
Moment of inertia I = 796876190.5 mm4
Zt = 3674.7 mm3
Required = -1.5 mm3
OK
Along the D
The bearing pressure at edge = 0.3 N/mm2
At column face = 0.1 N/mm2
Moment at column face = 659.7 N-mm/mm
Required thickness of plate = 4.9 mm
Thickness of plate is OK
Provided base plate thickness = 20.0 mm
Number of stiffener = 2.0
Thickness = 16.0 mm
Depth provided = 500.0 mm
Neutral axis depth Yb = 176.4 mm
Yt = 343.6 mm
Moment of inertia I = 722709333.3 mm4
Zt = 4674.1 mm3
Required = 3.0 mm3
OK
Anchor Bolts
Grade of Bolts 8.8
Tensile capacity of bolts 141.1 kN
Shear strength of bolts 90.7 kN
Length of bolts 900.0 mm
Along B
Total force is to be resisted by bolts = -253.3 kN
Hence there will tension in holding down bolts
Number of bolts required to resist tension = 1.8
Number of bolts required to resist shear = 0.4
Along D
Total force is to be resisted by bolts -320.0 kN
Hence there will tension in holding down bolts
Number of bolts required to resist tension = 2.3
Number of bolts required to resist shear = 0.2