Professional Documents
Culture Documents
T750a2 Falco
T750a2 Falco
POWER MAGNETICS
MECHANICAL SPECIFICATIONS
Front View Side View PCB Layout (Top) Schematic
A Pf B
0.600 3
[15.24]
0.360 Ps
[9.14] 0.300
C [7.62]
Primary Sec. #2
2 0.300
[7.62] Pf
Ps
0.033
1 3 1
[0.84]
D MAX.
1 2 3 3 2 f0.042 x 3
[1.067]
0.032
[0.81]
INCHES [mm]
ELECTRICAL SPECIFICATIONS
FALCO PART RoHS PART V/A TOL. Turns Irms max. DCR (Ω)1 A max. B max. C max. D min.
NUMBER NUMBER Ratio (Amps.) max. in / mm in / mm in / mm in / mm
T75001 0.100 ±2% 1000:1 60.00 43.00 0.940 / 23.88 0.480 / 12.19 1.000 / 25.40 0.200 / 5.08
T75L01 0.100 ±2% 1000:1 60.00 46.20 0.940 / 23.88 0.480 / 12.19 1.000 / 25.40 0.200 / 5.08
T75B01 0.100 ±2% 1000:1 60.00 46.20 0.940 / 23.88 0.480 / 12.19 1.000 / 25.40 0.170 / 4.32
T750A2 0.100 ±2% 1000:1 15.00 44.00 0.940 / 23.88 0.480 / 12.19 1.000 / 25.40 0.200 / 5.08