Classification

1. What is the minimum height of the manhole from finish floor level. (2mtrs). √
2. What is P A N I? Surge producer, absorber, on isolated equipment & isolated equipment. √
3. Osp mandrel size? 3 5/8 in 12in length
4. When Sloping and shoring required in trench excavation? Above 1.2 mtrs or above depth √
5. What test is required for copper cable before placement commenced? Continuity on reel
6. Choose the correct color of the subduct? Orange, green, white & blue.
7. The standard Rope size used in the duct bank? 6mm (1/4 in)
8. UL stands for?
9. Telecom conduit system refers to which standard? SAES-T-911. √
10. Minimum length of the patch cable? 5MTRS √
11. When Mandrel test is required? Before & after concrete
12. The length of the BSW shall not exceed the following length?150mtrs
13. Before HDD placement need approval from the following? Concern authority
14. What is the recommended space between the two conduits for concrete placement? 38mm
15. Fiber optics normally measured at what wavelength? 1310nm & 1550nm √
16. Fire resistant to a minimum of 1-hour fire rated for all TER/TR/EF. √
17. 80CM shall be the minimum distance from the finish floor level to splice end plate.
18. Underground entrance requirement?
Ans: - Conduit shall not be located more than 5cm (2in) from rear wall having the backboard and
not less than 15cm (6in) from the side wall.
19. Ef must be the demarcation (termination point) for designated outdoor use and cables
designated for indoor use.
20. When cable terminal requires surge protector? The recommended space allocation is 2 to 3
times larger than the space for regular cross connect.
21. Work area outlet and work area equipment not more than 5m(16ft).
22. Grounding rod height? 8ft √ dimension 5/8 8ft
23. Minimum bending radius for Foc? 10 times not under tension & 20 times under tension

(diameter). √
24. Telecom room equipped with heat sensors that will connect to noc & alarm indicators shall be
installed outside TER.
25. Front and rear side of equipment working clearance in TER/TR (91cm / 76cm) as per BICSI 1
MTRS.
26. Only non-filled fire-retardant rated splices shall be used only in buildings to splice an
outside plant cables with an indoor cable. OSP cables within the building shall be wrapped
with fireproof tape. Indoor cables shall be listed as Communication Riser Cable (Type
CMR). √

Classificatio
Classification

27. Splice loss shall not be more than 0.2 dB per splice.
28. The minimum bending radius for buffer tubes is usually between 38 mm (1.5 in.) and 76
mm (3.0 in.).

29. The splice closure is classified according to the configuration of cables that enter the closure
such as,
 Straight, Branch. √
30. What is the height of wireless access point from FFL (3.75mtrs).
31. SINGLE-MODE OPTICAL FIBER (Dispersion-Shifted or Non-Zero Dispersion-Shifted) - (In
accordance with applicable ITU-T-G.652 /ITU-T-G.653/ ITU-T-G.655).
32. 62.5 μm (core)/125 μm (cladding) MULTIMODE, GRADED-INDEX OPTICAL WAVEGUIDE FIBER
(In accordance with applicable EIA/TIA-455 series)
33. The Foc cable pulling tension shall not exceed 600 pounds.
34. Telecommunications building grounding shall have a Single-point Ground (SPG) System also

known as TMGB (Telecommunications Master Grounding Bus bar). √


P surge producers (such as interior radio equipment including cable trays that are connected to radio
equipment, Cable Shield/Cable Vault Ground Bar and MDF/Entrance Cable Protector Ground Bar)
A surge absorber (both ground leads coming from the opposite sides of the ground grid) √
N non-isolated equipment (DC Power system positive return bus, computer floor, communication
racks and cable trays)
I isolated equipment (electronic switching equipment and transmission systems and terminal
Equipment)

35. Machine bolts screwed into nonmetallic concrete inserts that have been cast in place. The
top cable rack support (type S or L) concrete insert is to be located 230 mm below the MH
roof.
36. Foc striped inside the splice closure (2.4 to 3.5).
37. What is produce when telecom utilities parallel through power lines (EMI). √
38. Power outlet of telecom & electrical separation (1mtrs).
39. Mounting Wall outlets shall be securely mounted at least 38 cm (15 in.) above the finished
floor or, a minimum of 150 mm above desk tops,
40. Wall mounted outlets Design telecommunications outlets so that installations in a dry-wall,
plaster, or concrete block wall will be at least 100 mm square by 57 mm deep (4 in. square
by 2 ¼ in. deep) or (4 in. square by 2 1/8 in. deep).
41. What is the height of the telecom room ceiling (2.6mtrs) 8.53ft
42. 100-Ohm UTP Cabling
1) Bend Radius
In spaces with UTP terminations, cable bend radii shall not be less than four times the cable
diameter for outlet cable.
2) Pulling Tension
The maximum pulling tension for a 4-pair 24-AWG UTP cable should not exceed 110 N (25
lbf).
43. The operating voltage of “in-plant party paging stations” shall be 120 Volts AC, 60 Hz.

Classificatio
Classification

44. Acoustical booths shall be furnished for the party paging stations in areas where ambient
noise levels exceed 80 dBA. The ambient noise level measured inside the acoustical booths
shall not exceed 80 dBA.
45. Loudspeakers shall be installed in areas where ambient noise levels exceed 90 Dba.
46. The in-plant party paging communications system shall include a multi-tone yelp, warble,
siren and steady tone.
47. Handset cable of party paging stations shall be retractile and extendible to at least 180 cm.
48. The loudspeaker for the party paging system shall be mounted to a minimum height of 2.5
meters. The loudspeaker cone shall not point upwards in a vertical direction.

49. Enclosures
The enclosures for “in-plant party paging communications equipment” shall comply with;
NEMA type 12 - for indoor, non-hazardous locations
NEMA type 4X - for outdoor non-hazardous location
50. what is the minimum size of the ground conductor cable for telecom utility 6AWG (16mm) √
51. What Is the min allowable measurement of lighting inside the telecom room 540lux √
52. Splicing hardware is determined by (mounting requirement, optical fiber count & splicing).
53. SAES-T-928 - telecom Osp buried cable
54. SAES-T-911- Conduit system √
55. SAES-T-916 Building cable system pathway & spaces
56. SAES-T-624 Telecommunications: Fiber Optic Cables for Outside Plant (OSP) and Inter/Intra
Building Applications
57. SAES-T-632 Splicing and closure
58. SAES-T-795 Bonding and grounding
59. SAES-T-629 Out side plant copper cable
60. SAES-T-493 Mobile and fixed radio system
61. SAES-T-494 VSAT
62. SAES-T-555 CCTV
63. SAES-T-566 DMZ
64. SAES-T-570 Design residential infrastructure
65. All Antennas for DTRS base station shall install a surge arrestor as per UL 452 “Antenna
Discharge Units for Radio and Television Receiving Appliances” and UL 497C “Equipment
Covered by the Standard for Protectors for Coaxial Communications Circuits.”
66. SAES-T-919 SUBMARINE FIBER OPTICS
67. SAES-T-018 Symbol & abbreviations
68. Humidity radio system
Indoor humidity design basis shall be 20% to 80% relative humidity. Outdoor design basis
shall be 5% to 95% relative humidity (non-condensing).

72 HVAC temperature range is


Temperature range of 18°C to 24°C, Humidity range of 30 to 55 %, Heat dissipation hour of 750
to 5,000 BTUs per cabinet. √
73 Minimum dimension of TMGB?
Have a minimum dimension of 6 mm (thick) X 100 mm wide X 500 mm (length).

Classificatio
Classification

74 What is GPR? Ground potential rise due to the flow of lightning or power fault currents.
Lightning, Accidental contact with light or power lines of 300 volts or more.
75 Main conduit curves
Transverse more than 90 degrees & Have a radius of less than 6 m. √
76 Attenuation
The maximum attenuation of each fiber within a cable, when normalized to a length of 1 km. At
wavelength = 1,300 nm, shall be 0.5 dB/km or less, and at wavelength = 1,550 nm, shall be 0.3 dB/km or

less. √
77 Power outlet requirement in TR
6-inches above the floor and placed at 1.8-meter (6 ft.) intervals around perimeter walls

Classificatio