Professional Documents
Culture Documents
Parts List For Schneider Electric Electromagnetic Flow Products
Parts List For Schneider Electric Electromagnetic Flow Products
PL 008-760
Parts List
https://www.se.com
Legal Information
The Schneider Electric brand and any trademarks of Schneider Electric SE and its
subsidiaries referred to in this guide are the property of Schneider Electric SE or its
subsidiaries. All other brands may be trademarks of their respective owners.
This guide and its content are protected under applicable copyright laws and furnished
for informational use only. No part of this guide may be reproduced or transmitted in
any form or by any means (electronic, mechanical, photocopying, recording, or
otherwise), for any purpose, without the prior written permission of Schneider Electric.
Schneider Electric does not grant any right or license for commercial use of the guide
or its content, except for a non-exclusive and personal license to consult it on an "as is"
basis. Schneider Electric products and equipment should be installed, operated,
serviced, and maintained only by qualified personnel.
As standards, specifications, and designs change from time to time, information
contained in this guide may be subject to change without notice.
To the extent permitted by applicable law, no responsibility or liability is assumed by
Schneider Electric and its subsidiaries for any errors or omissions in the informational
content of this material or consequences arising out of or resulting from the use of the
information contained herein.
Parts List for Schneider Electric Electromagnetic Flow Products
Table of Contents
Important Safety Instructions ..........................................................................5
IMT33A Magnetic Flow Signal Converter .....................................................6
Model Code -IMT33A .......................................................................................6
Ordering Instructions ..................................................................................8
Parts - IMT33A.................................................................................................9
Field Mount Covers ........................................................................................ 11
Reference Documents....................................................................................13
IMT31A Magnetic Flow Signal Converter ...................................................14
Model Code - IMT31A.....................................................................................14
Ordering Instructions ................................................................................15
Parts - IMT31A...............................................................................................16
EMF Signal Cable for IMT31A .........................................................................16
Reference Documents....................................................................................17
IMT30A Magnetic Flow Signal Converter ...................................................18
Model Code - IMT30A.....................................................................................18
Ordering Instructions ................................................................................19
Parts - IMT30A...............................................................................................20
Reference Documents....................................................................................20
9500A Magnetic Flow Sensor .......................................................................21
Model Code - 9500A.......................................................................................21
Parts - 9500A.................................................................................................24
Reference Documents....................................................................................24
9600A Magnetic Flow Sensor .......................................................................25
Model Code - 9600A.......................................................................................25
Ordering Instructions ................................................................................27
Parts - 9600A.................................................................................................28
Reference Documents....................................................................................30
8400A Magnetic Flow Sensor .......................................................................31
Model Code - 8400A.......................................................................................31
Parts - 8400A.................................................................................................33
Reference Documents....................................................................................33
8500A Magnetic Flow Sensor .......................................................................34
Model Code - 8500A.......................................................................................34
Ordering Instructions ................................................................................36
Parts - 8500A.................................................................................................37
Reference Documents....................................................................................37
9700A Magnetic Flow Sensor .......................................................................38
Model Code - 9700A.......................................................................................38
Ordering Instructions ................................................................................42
Parts - 9700A.................................................................................................42
Reference Documents....................................................................................43
6500W Magnetic Flow Tube .........................................................................44
Model Code - 6500W......................................................................................44
PL 008-760 3
Parts List for Schneider Electric Electromagnetic Flow Products
Parts - 6500W................................................................................................46
Reference Documents....................................................................................46
IMT65W Magnetic Flow Transmitter ............................................................47
Model Code - IMT65W....................................................................................47
Ordering Instructions ................................................................................48
Parts - IMT65W..............................................................................................49
Reference Documents....................................................................................51
4 PL 008-760
Important Safety Instructions Parts List for Schneider Electric Electromagnetic Flow Products
This safety alert symbol that lets you know about potential personal
injury hazards. Obey all safety messages with this symbol to avoid
possible injury or death.
DANGER
DANGER indicates a hazardous situation which, if not avoided, will result in death
or serious injury.
Failure to follow these instructions will result in death or serious injury.
WARNING
WARNING indicates a hazardous situation that, if not avoided, could result in
death or serious injury.
Failure to follow these instructions can result in death, serious injury, or
equipment damage.
CAUTION
CAUTION indicates a hazardous situation that, if not avoided, could result in
minor or moderate injury.
Failure to follow these instructions can result in injury or equipment damage.
NOTICE
NOTICE is used to address practices not related to physical injury.
Failure to follow these instructions can result in equipment damage.
Please Note
Electrical equipment should only be installed, operated, serviced, and maintained by
qualified personnel. No responsibility is assumed by Schneider Electric for any
consequences arising out of the use of this material.
A qualified person is one who has skills and knowledge related to the construction,
installation, and operation of electrical equipment and has received safety training to
recognize and avoid the hazards involved.
PL 008-760 5
Parts List for Schneider Electric Electromagnetic Flow Products IMT33A Magnetic Flow Signal Converter
Code Description
Model
IMT33A Magnetic Flow Signal Converter
Type
Power Supply
4 24 VDC/AC
A 100-230 VAC (85-253 VAC, 50/60 Hz)
Ex Version
0 without - non Ex
1 Ex zone 1 (terminal compartment “d” - Compact)
A cCSAus OL
W RU EAC (Russia)1
X KA EAC (Kazakhstan)1
Y BE EAC (Belarus)1
Cable Connection
4 3 x ½” NPT
5 3 x PF ½
6 3 x M20 x 1.5
Operating Manual/Operating Language
1 German/German
3 English US/English US
6 PL 008-760
IMT33A Magnetic Flow Signal Converter Parts List for Schneider Electric Electromagnetic Flow Products
Code Description
4 French/French
A English GB/eastern Europe group (GB, CZ, HU, SI, SL, AL, BG & RO)
B English GB/northern Europe group (GB, DK, FI, LT, NO, PL, EE & LV)
R Without/Chinese 2
S English GB/Russian
X Without/Russian
Custody Transfer
0 Without
Process Diagnostics
0 Standard
4 Batch controlling - BC
1 Standard
2 Stainless steel 1.4408/316 (Compact & Field only)
Communication
13 Basic IO (4-20 mA/HART + pulse/frequency + status + control output)
G IO RS485 Modbus
1st IO Module
03 Without, no module possible
8 Without IO module
3
PL 008-760 7
Parts List for Schneider Electric Electromagnetic Flow Products IMT33A Magnetic Flow Signal Converter
Code Description
84 Without IO module
A Current output - active
Reference Method
0 Standard
1 Virtual Reference
Tag plate (Field and Wall Only)
0 Standard
2 316/1.4401 Tag plate (120 x 46 mm)
Ordering Instructions
Give instrument Model Code when ordering.
4. Standard
8 PL 008-760
IMT33A Magnetic Flow Signal Converter Parts List for Schneider Electric Electromagnetic Flow Products
Parts - IMT33A
Figure 1 - IMT33A Field Version
PL 008-760 9
Parts List for Schneider Electric Electromagnetic Flow Products IMT33A Magnetic Flow Signal Converter
Table 2 - Parts for IMT33A Field Version and IMT33A Wall-Mounted Version
10 PL 008-760
IMT33A Magnetic Flow Signal Converter Parts List for Schneider Electric Electromagnetic Flow Products
PL 008-760 11
Parts List for Schneider Electric Electromagnetic Flow Products IMT33A Magnetic Flow Signal Converter
1 2
3 4
5 6
Table 4 - Parts for IMT33A Field Version and IMT33A Wall-Mounted Version
12 PL 008-760
IMT33A Magnetic Flow Signal Converter Parts List for Schneider Electric Electromagnetic Flow Products
Table 4 - Parts for IMT33A Field Version and IMT33A Wall-Mounted Version (Continued)
XN00101250 DS blue IMT31A W/Ex & IMT33A F/Ex 100 m (328 ft)
XN00101260 DS blue IMT31A W/Ex & IMT33A F/Ex 300 m (984 ft)
XN00101270 DS blue IMT31A W/Ex & IMT33A F/Ex 500 m (1640 ft)
XN00101280 DS blue IMT31A W/Ex & IMT33A F/Ex 1000 m (3280 ft)
Reference Documents
Document Number Description
PL 008-760 13
Parts List for Schneider Electric Electromagnetic Flow Products IMT31A Magnetic Flow Signal Converter
Code Description
Model
IMT31A Magnetic Flow Signal Converter
Type
-N IMT31A wall-mounted
Power Supply
1 12-24 VDC
4 24 VDC/AC (19-31 V)
Ex Version
0 without - non Ex
2 Ex zone 1 (terminal compartment “e” - compact & wall) (9500A tubes only)
A cCSAus OL
G IECEx zone 1 (terminal compartment “e” - compact & wall) (9500A tubes only)
T BE-Ex EAC (Belarus “e” - Compact & Field) 5(9500A tubes only)
U RU-Ex EAC (Russia “e” - Compact & Field) 5(9500A tubes only)
V KA-Ex EAC (Kazakhstan “e” - Compact & Field) 5(9500A tubes only)
W RU EAC (Russia) 5
X KA EAC (Kazakhstan) 5
Y BE EAC (Belarus) 5
Cable Connection
4 ½ in NPT
5 PF ½
6 M20 x 1.5
Operating Manual/Operating Language
5 see below/German
6 see below/English GB
7 see below/French
8 see below/Spanish
A see below/eastern Europe group (GB, CZ, HU, SI, SL, AL, BG & RO)
B see below/northern Europe group (GB, DK, FI, LT, NO, PL, EE & LV)
14 PL 008-760
IMT31A Magnetic Flow Signal Converter Parts List for Schneider Electric Electromagnetic Flow Products
Code Description
H see below/Italian
K see below/Portuguese
L see below/Dutch
M see below/Swedish
R see below/Chinese 6
X see below/Russian
Custody Transfer
0 Without
Process Diagnostics
0 Standard
C Tropicalized electronics for non Ex (not for 12-24 VDC)
1 Standard
2 Stainless steel
Communication
1 Basic IO (4-20 mA/HART + pulse/frequency + status output)
1st IO Module
0 Without, no module possible
Reference Method
0 Standard
Tag Plate(Field & Wall Only)
0 Standard
2 316/1.4401 Tag plate (120 x 46 mm)
Manuals
1 German
3 7 English
4 French
Ordering Instructions
Give instrument Model Code when ordering.
PL 008-760 15
Parts List for Schneider Electric Electromagnetic Flow Products IMT31A Magnetic Flow Signal Converter
Parts - IMT31A
Table 6 - Parts for IMT31A (Not Shown)
1 2
3 4
5 6
16 PL 008-760
IMT31A Magnetic Flow Signal Converter Parts List for Schneider Electric Electromagnetic Flow Products
XN00101250 DS blue IMT31A W/Ex & IMT33A F/Ex 100 m (328 ft)
XN00101260 DS blue IMT31A W/Ex & IMT33A F/Ex 300 m (984 ft)
XN00101270 DS blue IMT31A W/Ex & IMT33A F/Ex 500 m (1640 ft)
XN00101280 DS blue IMT31A W/Ex & IMT33A F/Ex 1000 m (3280 ft)
CG100G1100 Power supply "4", 24 V DC/AC, not for Normal AC operation, Basic I/O
Reference Documents
Document Number Description
PL 008-760 17
Parts List for Schneider Electric Electromagnetic Flow Products IMT30A Magnetic Flow Signal Converter
Code Description
Model
IMT30A Magnetic Flow Signal Converter
Type
Power Supply
1 12-24 VDC
A 100-230 VAC (85-253 VAC, 50/60 Hz)
Ex Version
0 without - non Ex
Cable Connection
4 ½ in NPT
5 PF ½
6 M20 x 1.5
Operating Manual/Operating Language
5 without/German
6 without/English GB
7 without/French
8 without/Spanish
A without/eastern Europe group (GB, CZ, HU, SI, SL, AL, BG & RO)
H without/Italian
K without/Portuguese
L without/Dutch
M without/Swedish
R without/Chinese 8
X without/Russian
Custody Transfer
0 Without
Process Diagnostics
0 Standard
Signal Converter Housing
1 Standard
Communication
1 Basic IO (4-20 mA/HART + pulse/frequency + status output)
18 PL 008-760
IMT30A Magnetic Flow Signal Converter Parts List for Schneider Electric Electromagnetic Flow Products
Code Description
1st IO Module
0 Without, no module possible
Reference Method
0 Standard
Tag Plate (Field & Wall Only)
0 Standard
2 316/1.4401 Tagplate (120 x 46 mm)
Manuals
1 German
3 9 English
4 French
Ordering Instructions
Give instrument Model Code when ordering.
9. Standard
PL 008-760 19
Parts List for Schneider Electric Electromagnetic Flow Products IMT30A Magnetic Flow Signal Converter
Parts - IMT30A
Figure 6 - Parts for IMT30A
Display Tool
Spare Electronics
Reference Documents
Document Number Description
20 PL 008-760
9500A Magnetic Flow Sensor Parts List for Schneider Electric Electromagnetic Flow Products
Code Description
Model
9500A Magnetic Flow Sensor
PL 008-760 21
Parts List for Schneider Electric Electromagnetic Flow Products 9500A Magnetic Flow Sensor
Code Description
Nominal Pressure
-1 PN 6 EN 1092-1 (DN 1200…2000)
Ex Version 10
0 non Ex
1 EEx zone 1 (for IMT33A Compact and Field, IMT31A Compact and Wall only)11
5 FM Class I DIV 2 (for IMT33A Compact and Field, IMT31A Compact and Wall only
A cCSAus OL (for IMT33A Compact and Field, IMT31A Compact and Wall only)
C CSA Class I DIV 2 (for IMT33A Compact and Field, IMT31A Compact and Wall only)
T BE-Ex EAC (Belarus IMT33A Compact and Field, IMT31A Compact and Wall only)11
U RU-Ex EAC (Russia IMT33A Compact and Field, IMT31A Compact and Wall only)11
V KA-Ex EAC (Kazakhstan IMT33A Compact and Field, IMT31A Compact and Wall only)11
W RU-EAC (Russia)11
X KA-EAC (Kazakhstan)11
Y BE-EAC (Belarus)11
System Design
Converter Model
0 Without/modular
3 IMT31A (Compact design)
10. To maintain certification, make sure the transmitter being used is listed in the description.
11. Check BuyAutomation for availability
22 PL 008-760
9500A Magnetic Flow Sensor Parts List for Schneider Electric Electromagnetic Flow Products
Code Description
Lining
Electrodes (Fixed)
3 Nickel alloy12
6 Titanium
B Nickel alloy 13
Construction of Electrodes
1 Fixed
Housing/Flange Material
1 Steel/steel St 37-c22/A105
3 Steel/stainless steel DIN 1.4404|316 L
0 IP66/67/standard
1 IP68 Field/standard (with stainless steel connection box)
3 IP66/67/ISO 13359
4 IP68 Field /ISO 13359 (with stainless steel connection box)
Cable
0 Compact - without/separate DS
1 Separate BTS
2 Separate LIYCY (only for FM/CSA Class 1 DIV 2) (only for IMT33A and IP68)
Y Without
Cable Length
1 10 m (30 ft)
2 15 m (45 ft)
12. Equivalent to Hastelloy® C4. Hastelloy is a registered trademark of Haynes International, Inc.
13. Equivalent to Hastelloy® C22.
PL 008-760 23
Parts List for Schneider Electric Electromagnetic Flow Products 9500A Magnetic Flow Sensor
Code Description
3 20 m (60 ft)
4 25 m (75 ft)
5 30 m (90 ft)
6 40 m (120 ft)
7 50 m (150 ft)
Y Without
Calibration
0 Standard
2 316|1.4401 Tag plate (120 x 46 mm)
Ring /Material
0 Without
5 Ring #1/Titanium
6 Ring #1/1.4404|316 L
E Ring #3/1.4404|316 L
Construction Requirements
0 Standard
QA/QC Requirements
0 Standard
Ratio of CT-Calibration
0 Standard, R=80
Parts - 9500A
Not applicable. There are no parts available for the 9500A.
Reference Documents
Document Number Description
24 PL 008-760
9600A Magnetic Flow Sensor Parts List for Schneider Electric Electromagnetic Flow Products
Code Description
Model
9600A Magnetic Flow Sensor
Connection / Pressure
-H DIN 11851 - Dairy screw connection
Ex Version
0 non Ex
5 FM Class I DIV 2 (IMT33A Field [DN 2.5…15])
PL 008-760 25
Parts List for Schneider Electric Electromagnetic Flow Products 9600A Magnetic Flow Sensor
Code Description
Converter Model
0 Without/modular
3 IMT31A (Compact design)
Mounting Material
0 Without
Grounding Ring Material
Electrodes (Fixed)
6 Titanium
7 Platinum (wetted parts) (DN 2.5…15, 1/10 in...½ in)
0 IP66/67/standard
1 IP68 Field/standard (with stainless steel connection box)
Cable
0 Compact - without/separate DS
1 Separate BTS
26 PL 008-760
9600A Magnetic Flow Sensor Parts List for Schneider Electric Electromagnetic Flow Products
Code Description
Y Without
Cable Length
1 10 m (30 ft)
2 15 m (45 ft)
3 20 m (60 ft)
4 25 m (75 ft)
5 30 m (90 ft)
6 40 m (120 ft)
7 50 m (150 ft)
Y Without
Calibration
0 Standard
2 316|1.4401 Tagplate (120 x 46 mm)
Construction Requirements
0 Standard
QA/QC Requirements
0 Standard
Ratio of CT-Calibration
0 Standard, R=80
Ordering Instructions
Give instrument Model Code when ordering.
PL 008-760 27
Parts List for Schneider Electric Electromagnetic Flow Products 9600A Magnetic Flow Sensor
Parts - 9600A
Figure 7 - 9600A
5 6 7
8 9 10
11 12 13
14 15 16
28 PL 008-760
9600A Magnetic Flow Sensor Parts List for Schneider Electric Electromagnetic Flow Products
N/A VN994058S120000 1 DN 2.5 - DN 15 - Nickel alloy (a) Grounding ring for flange type
PL 008-760 29
Parts List for Schneider Electric Electromagnetic Flow Products 9600A Magnetic Flow Sensor
Reference Documents
Document Number Description
MI 021-521 Instruction, Model 9600A Magnetic Flow Tube for hygienic and sanitary applications
PSS 1-6H5 A Product Specifications, Model 9600A Magnetic Flow Tube for hygienic and sanitary applications
30 PL 008-760
8400A Magnetic Flow Sensor Parts List for Schneider Electric Electromagnetic Flow Products
Code Description
Model
8400A Magnetic Flow Sensor
A 150 lbs RF ASME B 16.5 (3/8 in…6 in) maximum working pressure 232 psi
B 300 lbs RF ASME B 16.5 (3/8 in…4 in) derated / maximum working pressure 232 psi
Approval
0 non Ex
5 FM Class I DIV 2 (for IMT33A Compact and Field only)
A cCSAus OL (IMT33A Compact and Field & IMT31A Compact and Wall only)
Converter Model
0 Without
3 IMT31A (Compact/Integral Design)
PL 008-760 31
Parts List for Schneider Electric Electromagnetic Flow Products 8400A Magnetic Flow Sensor
Code Description
Mounting Material
318 St. Steel DIN 1.4404|316L (DN 10…15|3/8 in...½ in), without (DN 25…150|1 in...6 in)
Electrodes
B Standard, Nickel alloy 19
0 IP66/67/Standard dimension
Cable
018 Compact (none) - Separate (remote) DS
1 Separate BTS
Y Without
Cable Length
1 10 m (30 ft)
2 15 m (45 ft)
3 20 m (60 ft)
4 25 m (75 ft)
5 30 m (90 ft)
6 40 m (120 ft)
7 50 m (150 ft)
Y Without
Calibration
0 Standard
2 Standard calibration + 316/1.4401 Tagplate (120 x 46 mm)
32 PL 008-760
8400A Magnetic Flow Sensor Parts List for Schneider Electric Electromagnetic Flow Products
Code Description
Special
0 Standard
Version
H Standard
Construction Requirements
0 Standard
QA/QC Requirements
0 Standard
Ratio of CT-Calibration
0 Standard, R=80
Warranty
0 Standard
Instruction language
0 Standard
Parts - 8400A
Not applicable. There are no parts available for the 8400A.
Reference Documents
Document Number Description
PSS 1-6H7 A Product Specifications, Model 8400A Magnetic Flowmeter in wafer version
PL 008-760 33
Parts List for Schneider Electric Electromagnetic Flow Products 8500A Magnetic Flow Sensor
Code Description
Model
8500A Magnetic Flow Sensor
Approval
0 non Ex
1 Ex Zone 1 (for IMT33A Compact and Field & IMT31A Wall only)
A cCSAus OL (IMT33A Compact and Field & IMT31A Compact and Wall only)
34 PL 008-760
8500A Magnetic Flow Sensor Parts List for Schneider Electric Electromagnetic Flow Products
Code Description
Converter Model
0 Without
3 IMT31A (Compact/Integral Design)
Mounting Material
3 20 St. Steel DIN 1.4404|316 - O-ring FPM|FKM (DN 2.5...15|1/10 in...1/2 in)
T St. Steel DIN 1.4404|316 - O-ring EPDM (DN 2.5...15|1/10 in...1/2 in)
7 Nickel alloy (a) O-ring EPDM (DN 2.5...15 - 1/10 in...1/2 in)
G St. Steel DIN 1.4571|316 Ti - Gasket filled PTFE (DN 25…100/1 in...4 in)
R St. Steel DIN 1.4571|316 Ti - Gasket graphite (DN 25…100/1 in...4 in)
Electrodes
0 20 Standard, Platinum
7 Cermet - Platinum
Protection Class/Dimension (Face-to-Face)
PL 008-760 35
Parts List for Schneider Electric Electromagnetic Flow Products 8500A Magnetic Flow Sensor
Code Description
Cable
0 22 Compact (none) - Separate (remote) DS
1 Separate BTS
2 Separate LIYCY (only for FM/CSA Class 1 DIV 2 with IP68 and IMT33A)
Y Without
Cable Length
1 10 m (30 ft)
2 15 m (45 ft)
3 20 m (60 ft)
4 25 m (75 ft)
5 30 m (90 ft)
6 40 m (120 ft)
7 50 m (150 ft)
Y Without
Calibration
0 Standard
2 Standard calibration + 316/1.4401 Tagplate (120 x 46 mm)
Special
0 Standard
Version
H Standard
Construction Requirements
0 Standard
QA/QC Requirements
0 Standard
Ratio of CT-Calibration
0 Standard, R=80
Warranty
0 Standard
Instruction language
0 Standard
Ordering Instructions
Give instrument Model Code when ordering.
36 PL 008-760
8500A Magnetic Flow Sensor Parts List for Schneider Electric Electromagnetic Flow Products
Parts - 8500A
Table 16 - Parts for 8500A -Gaskets, filled PTFE (Garlock Blue Gylon 2504)
XN99021100 2 DN 15
XN99021110 2 DN 25
XN99021120 2 DN 40
XN99021130 2 DN 50
XN99021140 2 DN 80
XN99021150 2 DN 100
Reference Documents
Document Number Description
PSS 1-6H8 A Product Specifications, Model 8500A Magnetic Flowmeter wafer version
PL 008-760 37
Parts List for Schneider Electric Electromagnetic Flow Products 9700A Magnetic Flow Sensor
Code Description
Model
9700A Magnetic Flow Sensor
38 PL 008-760
9700A Magnetic Flow Sensor Parts List for Schneider Electric Electromagnetic Flow Products
Code Description
Nominal Pressure
-1 PN 6 EN 1092-1 (DN 1200...2000)
-M JIS 20 K (DN25…40|1 in…1 1/2 in) & (DN 200 … 600|8 in…24 in)
Approval 23
0 non Ex
1 Ex Zone 1
3 Ex Zone 2 (for IMT33A Compact and Field only). Only with Converter Model C, D
5 FM Class I DIV 2 (for IMT33A Compact and Field, IMT31A Compact and Wall only)
A cCSAus OL (for IMT33A Compact and Field, IMT31A Compact and Wall only). Only with Converter Model 3, 4,
C, D
C CSA Class I DIV 2 (for IMT33 Compact and Field, cFMus IMT31 Compact and Wall only)
D NEPSI Zone 1 (for IMT33A Compact and Field only). Only with Converter Model C, D
F IECEx Zone 1 (for IMT33A Compact and Field, DN 700...1200|28 in…48 in)
T BE-Ex EAC (Belarus; for IMT33A Compact and Field, IMT31A Compact and Wall only) 24
U RU-Ex EAC (Russia; for IMT33A Compact and Field, IMT31A Compact and Wall only) 24
V KA-Ex EAC (Kazakhstan; for IMT33A Compact and Field, IMT31A Compact and Wall only) 24
W RU-EAC (Russia) 24
X KA-EAC (Kazakhstan) 24
Y BE-EAC (Belarus) 24
System Design
23. To maintain certification, make sure the transmitter being used is listed in the description.
24. Check BuyAutomation for availability.
PL 008-760 39
Parts List for Schneider Electric Electromagnetic Flow Products 9700A Magnetic Flow Sensor
Code Description
Converter Model
0 Without - With system Design: 4, 5, 6, A, B, C
Lining
0 Standard
1 PTFE
2 PTFE - provided for protection rings (multiple sizes and rings)
A Soft Rubber - 6 mm thickness (DN 50 - DN 600 | 2 in to 24 in) (non Ex only) (Only with IMT33A)
D PU - Polyurethane
P Soft Rubber - 4 mm Thickness (DN 50 - DN 600 | 2 in - 24 in) (non Ex only) (Only with IMT33A)
Electrodes
1 Stainless Steel DIN 1.4571 | 316 Ti
3 Nickel alloy 25
4 Nickel alloy 26
5 Tantalum
6 Titanium
7 Platinum
B Nickel alloy 27
Construction of Electrodes
1 Fixed
Housing/Flange Material
40 PL 008-760
9700A Magnetic Flow Sensor Parts List for Schneider Electric Electromagnetic Flow Products
Code Description
U Housing: Duplex - Flanges: Steel St 37-C22/A105/A 105 (With St.St. Conn. Box.) (DN 10-20 | 3/8 in to 3/4 in)
V Housing: Duplex - Flanges: Steel St 1.4306/304/A 105 (With St.St. Conn. Box.) (DN 10-20 | 3/8 in to 3/4 in)
W Housing: Duplex - Flanges: Steel St 1.4404/316L/A 105 (With St.St. Conn. Box.) (DN 10-20 | 3/8 in-3/4 in)
0 IP66/67/Standard
1 IP68 Field/Standard (with stainless steel connection box)
3 IP66/67/ISO 13359
4 IP68 Field/ISO 13359 (with stainless steel connection box)
Cable
0 Compact (none) - Separate (remote) DS
1 Separate BTS
Y Without
Cable Length
1 10 m (30 ft)
2 15 m (45 ft)
3 20 m (60 ft)
4 25 m (75 ft)
5 30 m (90 ft)
6 40 m (120 ft)
7 50 m (150 ft)
Y Without
Calibration
0 Standard
2 Standard calibration + 316/1.4401 Tag plate (120 x 46 mm)
Grounding Ring/Materials
0 Without
4 Ring #1 - Tantalum
5 Ring #1 - Titanium
PL 008-760 41
Parts List for Schneider Electric Electromagnetic Flow Products 9700A Magnetic Flow Sensor
Code Description
6 Ring #1 - 1.4404|316 L
E Ring #3 - 1.4404|316 L
Finish
0 Standard
Special
0 Standard
Version
H Standard
Construction Requirements
0 Standard
QA/QC Requirements
0 Standard
Ratio of CT-Calibration
0 Standard, R=80
Warranty
0 Standard
Instruction Language
0 Standard
Ordering Instructions
Give instrument Model Code when ordering.
Parts - 9700A
Table 18 - Parts for 9700A-Junction Box
42 PL 008-760
9700A Magnetic Flow Sensor Parts List for Schneider Electric Electromagnetic Flow Products
Reference Documents
Document Number Description
PL 008-760 43
Parts List for Schneider Electric Electromagnetic Flow Products 6500W Magnetic Flow Tube
Code Description
Model
6500W Magnetic Flow Tube
Nominal Diameter
6501W DN 25...1 in
651HW DN 40...1½ in
6502W DN 50...2 in
652HW DN 65...2½ in
6503W DN 80...3 in
6504W DN 100...4 in
6505W DN 125...5 in
6506W DN 150...6 in
6508W DN 200...8 in
6510W DN 250...10 in
6512W DN 300...12 in
6514W DN 350...14 in
6516W DN 400...16 in
6518W DN 450...18 in
6520W DN 500...20 in
6524W DN 600...24 in
Nominal Pressure
-0 Gas threaded connection (only 1 in and 1.5 in)
-3 PN 16 EN 1092-1
-A 150 lb RF ASME B 16.5
-N 10K Conn. Acc. JIS B2220
System Design/Cable Connection
Transmitter Model
0 Without/modular
7 IMT65W (C) - IP68
44 PL 008-760
6500W Magnetic Flow Tube Parts List for Schneider Electric Electromagnetic Flow Products
Code Description
Lining
0 Standard (Rilsan)
Electrodes
B Nickel alloy 30
Housing Material
1 Steel
Protection Class/Dimension (Face-to-Face)
2 IP68 Factory/standard (with stainless steel connection box) (field) or IP68 Factory/standard (compact)
Cable
0 Compact - without/separate with WSC 2(V3 only)
Cable Length
1 10 m (30 ft)
4 25 m (75 ft)
Calibration
0 Standard
A Custody Transfer
Ring Material
0 Without
Finish
0 Standard
3 Offshore (IP68 only)
Reserved/Default
0 Reserved Field
Construction Requirements
0 Standard
QA/QC Requirements
0 Standard
Tag Plate
0 Standard
2 316/1.4401 Tagplate (120 x 46 mm)
PL 008-760 45
Parts List for Schneider Electric Electromagnetic Flow Products 6500W Magnetic Flow Tube
Code Description
Ratio of CT-Calibration
0 Standard, R=80
Instruction Language
1 German
3 English
4 French
Warranty
0 Standard
Destination
0 Standard
B Belarus
K Kazakhstan
R Russia
Flange Material
2 DIN 1.4301/304 L (Standard for sizes 6 in (DN 150) to 8 in, Optional for 10 in to 24 in)
Parts - 6500W
Not applicable. There are no parts available for the 6500W.
Reference Documents
Document Number Description
PSS 1-6H10 A Product Specifications, 6500W + IMT65W Battery Powered Electromagnetic Water Meter
46 PL 008-760
IMT65W Magnetic Flow Transmitter Parts List for Schneider Electric Electromagnetic Flow Products
Code Description
Model
IMT65W Magnetic Flow Transmitter
Type
Power Supply
Ex Version
0 non Ex
Cable Connection
F IP68 connector with 5 m (15 ft) output cable
Operating Manual
5 see below/German
6 see below/English
7 see below/French
Custody Transfer
5 Water, MI-001
Process Diagnostics
0 Standard
A P/T sensor
1 Standard polycarbonate
PL 008-760 47
Parts List for Schneider Electric Electromagnetic Flow Products IMT65W Magnetic Flow Transmitter
Code Description
Communication
1 Basic IO (2 passive pulse +2 passive status output - not activated)
K External Instruments
Electronic Option
H Standard
Tag Plate (Field Only)
0 Standard
2 316/1.4401 Tag plate (120 x 46 mm)
Instruction Language
1 German
3 English
4 French
Power Supply Wiring
0 Standard, battery
Destination
0 Standard
B Belarus
K Kazakhstan
R Russia
Ordering Instructions
Give instrument Model Code when ordering.
48 PL 008-760
IMT65W Magnetic Flow Transmitter Parts List for Schneider Electric Electromagnetic Flow Products
Parts - IMT65W
Figure 8 - Parts for IMT65W
PL 008-760 49
Parts List for Schneider Electric Electromagnetic Flow Products IMT65W Magnetic Flow Transmitter
Housing Parts
2 Housing Kit: Includes housing, union nut/ring, display cover and two
XN1204021H 1 gaskets
3
4
Not shown XN12041200 1 Opening Wrench
Power
XNCA030200 1 Battery pack double (2x lithium D-cell, 34 Ah)
XNCA030220 1 Battery pack double (2x lithium D-cell, 34 Ah) (origin France)
XNCA030400 1 Multi-Power
XN12030220 1 Battery pack double (2x lithium D-cell, 19 Ah) (origin France)
XNCA100110 1 IP68 connector with 5 m (15 ft) output cables (Basic IO, 8-Pins)
XNCA100120 1 IP68 connector with 10 m (30 ft) output cables (Basic IO, 8-Pins)
XNCA100130 1 IP68 connector with 25 m (75 ft) output cables (Basic IO, 8-Pins)
Not shown
XNCA100210 1 IP68 connector with 5 m (15 ft) output cables (Modbus IO, 4-Pins)
XNCA100220 1 IP68 connector with 10 m (30 ft) output cables (Modbus IO, 4-Pins)
XNCA100230 1 IP68 connector with 25 m (75 ft) output cables (Modbus IO, 4-Pins)
XNCA100310 1 IP68 connector with 5 m (15 ft) output cables (Basic IO, 8-Pins)
XNCA100320 1 IP68 connector with 10 m (30 ft) output cables (Basic IO, 8-Pins)
XNCA100330 1 IP68 connector with 25 m (75 ft) output cables (Basic IO, 8-Pins)
Not shown
XNCA100410 1 IP68 connector with 5 m (15 ft) output cables (Modbus IO, 4-Pins)
XNCA100420 1 IP68 connector with 10 m (30 ft) output cables (Modbus IO, 4-Pins)
XNCA100430 1 IP68 connector with 25 m (75 ft) output cables (Modbus IO, 4-Pins)
50 PL 008-760
IMT65W Magnetic Flow Transmitter Parts List for Schneider Electric Electromagnetic Flow Products
Reference Documents
Document Number Description
PSS 1-6H10 A Product Specifications, 6500W + IMT65W Battery Powered Electromagnetic Water Meter
PL 008-760 51
Schneider Electric Systems USA, Inc.
70 Mechanic Street
Foxboro, MA 02035
United States of America
© 2016 – 2023 Schneider Electric Systems USA, Inc. All rights reserved.
PL 008-760