Flow Switch 10.2.

calorimetric EFKP/EFKM EFKP/M

ELECTRICAL DATA
temperature output only with EFKT
display 9 LED's (red = limit,
PNP
green 1-8 = min.-max. flow brow n
setting potentiometer single-threaded 1 +
supply voltage 24 V DC ±20% w hite
2 Temp.
current consumption 70mA z
blue
3 0V
signal PNP or NPN z
black
load 200mA max. 4 Flow
connection at locking plug M12x1, 4-pole z=load
NPN
short-circuit proof yes brow n
reverse polarity proof yes 1 +
z
protection class EFKP IP 60, EFKM IP 67 w hite
2 Temp.
blue
3 0V
black z
4 Flow

MOUNTING POSITION METERING SUBSTANCES

water for aggressive liquids

oil

NOMENCLATURE
basic type
EFKP- 015 H K 029 P S specification
EFKP-  with plastic head
EFKPT-  calorimetric with plastic head and temperatur switch
EFKM-  Flow Switch with metal head
EFKMT-  with metal head and temperatur switch
008  connection G1/4A
015  connection G1/2A
038  connection footstuffs sensor ISO 2852 size 38
H  socket thread
L  footstuffs sensor
K  stainless steel 1.4571
029  probe length 29.6mm
028  probe length 28mm
045  probe length 45mm
056  probe length 56mm
P  PNP output
N  NPN output
Locking plug KPU-02SG
S 
M12x1, 4-polr, cable 2 m, straight plug
H  with goose-neck

ACCESSORY
Locking plug M12x1
basic type
K PU- 02 S G specification
K  ready-made cable
KB04  self makable cable 4-pole
PU-  material PUR
02  length 2 m
05  length 5 m
10  length 10 m
S  moulded-on plug
G  straight plug
W  angled plug 90°

All technical changes reserved

BASIC Standard BASIC Programme option VARIO Special option ⊕ PLUS Accessories not recommendable

Distributed by: PVL Ltd - Crowborough, East Sussex, TN6 2NQ, UK 12.05.2005
T: +44(0)1892 664499 F: +44(0)1892 663690 E: sales@pvl.co.uk W: www.pvl.co.uk page 2 of 2