Brochure For LGG160D Single Phase DIN-Rail LCD Smart Prepaid Meter ENV5.0

You might also like

Download as pdf or txt
Download as pdf or txt
You are on page 1of 4

LGG160D

LGG160D is a single phase DIN-Rail


prepaid meter with LCD display which is
configurable for power grid monitoring,
load controlling, tamper monitoring and
vending. It offers a plug and play module
and an advanced anti-tamper solution to
help utility increase the revenues and
decrease the line loss.
It complies with STS/CTS standard and
DLMS/COSEM open protocol. A wise
solution for residential customer.
LGG160D Main Functionalities :
ICO Function Function Icon and Description
ØActive and Reactive Energy
ØImport and Export Energy
Measurement
ØAbsolute and Algebra Active Energy

ØUp to 4 TOU tariffs


ØUp to 10 switch-time tables and 8 day-tables
Multi TOU Tariff
ØUp to 12 week-tables and 12 season- tables
(Optional)
ØUp to 100 holiday-tables

ØBlock and Slide demand mode


ØActive/reactive maximum demand
Max-Demand
ØRecord 13 months Maximum Demand (KW,KVAR)

ØLarge display with 10x5mm size and eight digits


ØOBIS code and functional icon, easy to read
ØUp to 8 digits number (6+2,7+1,8+0)
LCD display
ØWide viewing angle
ØHighlighting Backlight

ØSTS, CTS and STS6


ØPrepaid and Post-paid switchover
ØLocal and remote charge
Prepayment
ØLED and Buzzer for low credit alarm
ØEmergency credit and friendly mode

ØUp to 10 steps tariff


ØUp to 5 steps Monthly service charge
ØUp to 5 kinds subsidy
Tariff Expense
ØUp to 3 kinds fixed charge
(Optional)
ØUp to 5 kinds levies charge
ØUp to 3 kinds VAT charge

ØMulti control mode


ØLocal and remote load control
ØDisconnection scheme can be configurable
Load control
ØRelay status indicator
ØRelay malfunction self-check

ØUp to 2 Megabytes of Non-volatile memory


ØUp to 3 channels profiles
Load Profile ØUp to total 100 days records
ØCapture period and members can be configurable

ØUp to 4 independent communication ports


ØOptical Port for local communication
ØMC171 Port for the data recovery maintenance
Communication
ØPlug and play modem for remote communication:
Ports
GPRS/3G/4G/Ethernet/NB-IoT/PLC/RF/Lora…(Optional)
ØHAN modem for home area network communication
wired MBUS.
LGG160D Main Functionalities :
ICO Function Function Icon and Description
ØUp to 100 standard event records with occurred date
and time: low battery, clock sync, clock malfunction, NV
memory malfunction, watchdog reset, meter malfunction,
MD reset, high temperature, firmware upgrade etc.
ØUp to 225 tamper event records with occurred date and
time: meter cover open, terminal cover open, module
cover open, strong magnetic interference, unauthorized
login, parameter configuration etc.
ØUp to 100 control event records with occurred date and
time: disconnect the breaker, connect the breaker,
Event breaker control failure etc.
ØUp to 225 power grid event records with occurred date
and time: power on, power off, under voltage, over
voltage, over current, over load, current polarity reversal,
current bypass, low power factor, neutral disturbance etc.
ØUp to 50 charge event records with occurred date and
time: charging value, charging TOKEN etc.
ØUp to 50 management TOKEN event records with
occurred date and time: Management TOKEN type,
management TOKEN etc.

ØUp to 3 sealing positions


ØTerminal cover, meter cover and module cover sealing
ØSelf-protection under Over load control, Abnormal
Anti Tamper
voltage control, Arrearage control, Tamper control,
Malfunction control, Fire disaster control etc.

ØAlarms with LED/Buzzer and LCD on CIU


Alarm ØAlarm can be configurable

ØInternational open protocol


ØIEC62056-21 E mode DLMS
Communication Protocol ØHDLC DLMS and TCPIP DLMS
ØSTS/CTS TOKEN and SMS

ØUp to 13 month billing data


ØCalculate monthly net consumption of energy
Billing Record ØUp to 31 days daily data
ØCalculate daily net consumption of energy

ØFirmware upgrade
Firmware Upgrade ØFast and stable solution

ØHandy keypad
ØLCD display with backlight
ØConsumption rate indicator
CIU/UIU unit
ØWired MBUS Communication
ØAlarm with LED/LCD/Buzzer
ØEasy to install
LGG160D Technical Specification :
Description Value
Rated voltage 220V~240V

Operating voltage range 60%Un~130%Un


Rated Current and Starting Current 5(100)A,5(80)A,5(60)A and 0.4%Ib
Rated frequency 50Hz
1000imp/kWh
Pulse Constant
1000imp/kvarh
Cl.1 for Active
Accuracy Class
Cl.2 for Reactive
Power Consumption Voltage circuit < 1W or 5VA, Current circuit < 0.2VA
Battery and Life Replaceable Lithium battery, life more than 15 years
Tropical working temperature -40℃ to +70℃, Humidity is up to 95%
Impulse voltage > 8KV, AC voltage > 4KV, Short circuit
EMC Performance
current > 3KA, Electrostatic Discharge > 8KV&15KV etc.
IP54 comply with IEC60529
Protection class
Insulation grade II
Polycarbonate with non-conductive, high impact,
Housing material smooth finish, durable, non-flammable, UV stabilized,
UV resistant and high resistance to weathering
Dimension 155mmX70mmX70mm

LGG160D Diagram :

LONGI METER CO., LTD.


Sales Dept.:Building B1/8F, No.830, Wenyi West Road, Hangzhou 310012,China
E-Mail: overseas@longimeter.com
Web Site: www.longimeter.com

You might also like