Camera Setup: Electrical

You might also like

Download as pdf or txt
Download as pdf or txt
You are on page 1of 4

ELECTRICAL

Camera Setup

Camera Setup 2. Auto (R)LCD Backlight Control/Day/Night Settings


Press this button to switch between the ABC mode, the
The camera system consists of a 12 Vdc camera mod-
(R)LCD backlight day and the (R)LCD backlight night
ule with a heater capable of operating in -40 - 85° C
settings. The ABC mode controls the backlight settings
(-40 - 185° F) temperatures, as well as a 177.8 mm
between the minimum settings (which are adjustable,
(7 in) color LCD monitor. This section describes basic
see the service menu) and 100%, depending on the
monitor operation, navigation and standard setup pro-
amount of available ambient light. The day and night
cedures.
modes' brightness settings can be manually adjusted
by pressing the minus (6) or plus (7) buttons (the set-
Keyboard Operation tings will be saved). This setting is not camera specific
and will therefore function on all cameras.
3. Contrast
Press the contrast button once to enter the contrast ad-
justment mode. Use the minus (6) and plus (7) buttons
to select the image contrast.
4. Brightness
Press the brightness button once to enter the bright-
ness adjustment mode. Use the minus (6) and plus (7)
buttons to select the image brightness.
3. and 4. Saturation
Press the contrast button (3) and the brightness button
(4) at the same time to enter the saturation adjustment
mode. Use the minus (6) and plus (7) buttons to select
the image saturation.

NOTE
Figure 22802
The following buttons are used to scroll through the
The keyboard on the monitor consists of eight buttons various setup menus.
that facilitate navigation through the various setup
5. Option
menus. The following is a description of each button
and its function. Press the option button to return to the previous menu.
1. Camera Selection 6. Selection/Setting -
Press the camera selection button once. The camera Press the selection/setting - button to go to the next
LED will blink, indicating the manual camera override is menu option.
active. Use the minus (6) and plus (7) buttons to select
7. Selection/Setting +
the camera. You can select a different camera by
switching off this function by pressing the plus and mi- Press the selection/setting + button to go to the previ-
nus buttons. ous menu option.
8. Enter
Press the enter button to select or activate the high-
lighted option.

Crown 2009 PF17774-1 M4.3-1457-500

23
ELECTRICAL
Camera Setup

Standby Mode Horizontal Bars


The horizontal bars should be turned on and should be
NOTE adjusted, which can be accomplished by performing
The blue wire should not be connected to +BV during the following procedures.
this procedure. Otherwise, it will not be possible to en- 1. Open the service menu. To open the service
gage standby. This can be accomplished by raising the menu, press the minus (6), plus (7) and camera
mast above staging. selection buttons (1) at the same time. Refer to Fig-
The monitor should already come in standby mode. If it ure 22804.
is not, perform the following procedures to put the mon-
itor in standby mode.
1. When the monitor is switched ON, press the enter
button (8) on the keypad. This will bring up a menu
where standby is already highlighted. Refer to Fig-
ure 22803.

Figure 22804

2. Use the option (5), minus (6), plus (7) and enter (8)
buttons to scroll through the service menu.
3. Press the enter button (8) to activate the camera
settings menu. When entering the menu, use the
minus (6) and plus (7) buttons to select the camera
Figure 22803 (C1) to configure and press the enter (8) button.
The yellow cursor will jump to the list of items. Use
NOTE the minus and plus buttons to select the item to ad-
If the standby menu cannot be toggled, ensure the just, and press the enter button. If the selection op-
forks are above staging. If the standby menu still can- tion is ON/OFF, it will toggle between on (repre-
not be toggled, go into the keyboard menu and ensure sented by a large dot) and off (represented by a
it is not locked out (represented by a large dot instead small dot). If the option is a numeric value, it is pos-
of a small one). sible to change the value with the minus and plus
buttons. Press the enter button to store the new
2. Press the enter button (8) a second time and the setting. Refer to Figure 22805.
monitor will go into standby. A black screen will
now be shown. When the blue wire is connected to
BNEG (above staging), the monitor will be acti-
vated and the camera picture will be shown on the
screen. When the blue wire is either disconnected
(open) or connected to +BV (below staging), the
monitor will go back to standby and show a black
screen again.

Figure 22805

M4.3-1457-501 Crown 2009 PF17774-2

24
ELECTRICAL
Camera Setup

4. Scroll to the horizontal marker option. Enable this


option to switch the marker on. The marker is dis- Menu • Do not set.
played as a horizontal green line.
5. Scroll to the marker position option. This option ad-
Camera Switch • Set this option so camera
selection cannot be toggled.
justs the horizontal position of the marker. 0 is the
top of the screen, 100 is the bottom of the screen. Camera Setting • Set this option so brightness
Adjust the marker with the minus (6) and plus (7) cannot be changed, etc.
buttons until it hits the tip of the forks with the forks
extended and level. Press the option button (5) to
Standby • Set this option so the operator
cannot get the camera out of
return to the previous menu. standby below staging, thus
having the camera on.
Locking the Keyboard
1. In the camera settings menu, scroll to the system Language and Default Settings
settings menu and press the enter button (8).
When entering the system settings menu, use the Language
minus (6) and plus (7) buttons to select the key-
board to configure and press the enter button. The This option under the system setting menu opens the
yellow cursor will jump to the list of items. language selection menu. The selected language will
Scroll down to keyboard and press the enter but- be used for all OSD (on screen display) menus. The
ton. This will bring up the keyboard menu. Press OSD menus are available in English, Dutch, German,
the enter button to get into the keyboard lock French, Czech, Hungarian, Italian, Polish, Portuguese,
menu. Refer to Figure 22806. Spanish, Turkish, Swedish, Finnish, Danish and Nor-
wegian. Refer to Figure 22807.

Figure 22806
Figure 22807
2. In the keyboard lock menu, the following options
can be toggled ON (represented by a large dot)
and OFF (represented by a small dot).

Crown 2009 PF17774-3 M4.3-1457-502

25
ELECTRICAL
Camera Setup

NOTE
All user settings will be lost when the factory defaults
are reset.

Default Settings
This option under the system setting menu opens the
default settings menu. If the restore defaults option is
selected, the factory settings will be reset. The restore
defaults option can be used to get the service techni-
cian back to a known state. Refer to Figure 22808.

Figure 22808

M4.3-1457-503 Crown 2009 PF17774-4