7 6 5 4 3 2 1

DO NOT SCALE. IF IN DOUBT ASK!

F THE FOLLOWING IS A CONTINUATION OF (RIG - 001). F

THE OPEN ENDS OF THE UNISTRUT CHANNEL SHOULD BE FIXED INTO A SUITIBLE WALL.
FI IF NO SUITIBLE WALL IS AVALIBLE A 2ND RIG (001) CAN BE CONSTRUCTED 2m AWAY.

940mm
XI OR SUPPORTED BY UNISTRUT CHANNELS FIXED INTO THE GROUND.
NG
ZO
NE CUT 3 UNISTRUT CHANNELS TO 2.1m AND 2 UNISTRUT CHANNELS TO 1040mm.
. CUT TWO 50 x 50 x 0.7mm MIN THICK GALVANISED ANGLES TO 1240mm THEN SNIP THE ANGLES
100mm IN ON EITHER SIDE TO CREATE A 100mm FLANGE ON BOTH SIDES AND A 1040mm MAIN BODY.
2100mm

INSTALL 2 OF THE 2.1m UNISTRUT CHANNELS TO THE OUTER EDGES OF THE WOODEN RIG.
E THE 3RD CHANNEL IS INSTALLED IN THE CENTRE AT 1050mm E

USE UNISTRUT FIXING PLATES, SPING LOADED NUTS AND HEX SCREWS TO SECURE THE

940mm
1050mm

SMALLER UNISTRUT CHANNELS TO THE CENTRES OF THE LARGER CHANNELS.

1040mm 1040mm PLACE THE 50 x 50 x 0.7mm ANGLES ON THE INSIDE OF THE FRAMEWORK AND FIX TO
THE LARGER UNISTRUTS VIA THE FLANGE, USING FIRE RATED FIXINGS AS REQUIRED.
FIT THEM AS CLOSE TO THE VERTICAL RIG/FRAMEWORK AS POSSIBLE WHITHOUT BLOCKING
THE BOTTOM FACE OF THE ANGLE.

D D

1040mm UNISTRUT CHANNELS. 50 x 50 x 0.7mm GALVANISED ANGLE.

UNISTRUT FIXING PLATE. UNISTRUT FIXING PLATE.


2.1m UNISTRUT CHANNEL.
C C
UNISTRUT FIXING PLATE.

2.1m UNISTRUT CHANNEL. 50 x 50 x 0.7mm GALVANISED ANGLES.

2.1m UNISTRUT CHANNEL.

RIG - 001

B B

FIREFLY™ - HORIZONTAL TRAINING RIG


TBA PROTECTIVE TECHNOLOGIES LTD ARTIST: JC DRAWING NO:

ALL RIGHTS RESERVED. NO PARTS OF THIS DRAWING MAY BE USED REPRODUCED, ALTERED, STORED IN A
RETRIEVAL SYSTEM OR TRANSMITTED IN ANY FORM OR BY ANY MEANS WITHOUT THE PRIOR WRITTEN
UNIT 3, Transpennine Trading Estate, Gorrells Way
Rochdale, OL11 2PX, United Kingdom
APPROVED: CB RIG - 002
PERMISSION OF TBA PROTECTIVE TECHNOLOGIES LTD. WHILST EVERY EFFORT HAS BEEN MADE TO
A COMPLY WITH THE CURRENT STATUTORY REGULATIONS, IT IS THE USER'S RESPONSIBILITY TO ENSURE T: +44 (0)1706 758 817 DATE: 20/01/2023 REVISION: 1 A
THAT THE FINAL DETAILING AND INSTALLATION MEETS THE REQUIREMENTS OF RELEVANT REGULATORY
AUTHORITY (OFTEN BUILDING CONTROL). PLEASE CHECK www.tbafirefly.com TO ENSURE THAT YOU ARE E: Technical@TBAFIREFLY.com
USING THE CORRECT AND CURRENT VERSION. W: www.tbafirefly.com
COPYRIGHT 2022 SCALE: NTS IN SEQUENCE: 2/2