Download as pdf or txt
Download as pdf or txt
You are on page 1of 2

OEG BUIL DING M ATERIAL S - M ETAL FRAM ING M ANUFACTURERS

6001 BORDENTOWN AVE, SAYREVIL L E, NJ 0887 2

P 7 32.667.3636 I WWW.OEG USA.COM I ORDERS@ OEG USA.COM

CATEGORY MEMBER# GAGE COATING


Roof Deck 15BD358 20 G60

PHYSICAL PROPERTIES
Deck Type B Deck
Design Thickness 0.0358
Weight 2.1
Coating G60
SECTION PROPERTIES 40 KSI
Ip (In4) 0.191
In (In4) 0.2104
Sp (In3) 0.2122
Sn (In3) 0.2247

ALLOWABLE BENDING 40 KSI


M positive/ Ωinch-lbs per ft 5083
M negative/ Ωinch-lbs per ft 5382

SECTION PROPERTIES 50 KSI


Ip (In4) 0.191
In (In4) 0.2104
Sp (In3) 0.2122
Sn (In3) 0.2247

ALLOWABLE BENDING 50 KSI


M positive/ Ωinch-lbs per ft 6353
M negative/ Ωinch-lbs per ft 6728

ALLOWABLE WEB CRIPPLING DATA 40 KSI (LB)


Pe1 End 937
Pe2 End 996
Pe1 Interior 1513
Pe2 Interior 1887

ALLOWABLE WEB CRIPPLING DATA 50 KSI (LB)


Pe1 End 1171
Pe2 End 1207
Pe1 Interior 1891
Pe2 Interior 2359

NOTES
All section properties and ASD (Ω = 1.67) uniform loads are calculated in accordance with ANSI/SDI RD-2017 and AISI S100-2012 and
AISI S100-2016.
All section properties and strengths are reported per foot of panel width.
p = Property in positive bending; n = Property in negative bending.
Complies with the 2015 International Building Code and AISI S100-12
Zinc-Coated (Galvanized) sheet metal meets or exceeds ASTM A653 and ASTM A1003

DISCAIMER:
All data, detail and speci cations included in herein are intended as a general guide for using OEG Building Materials products. These products should not be used in design or construction without
evaluation by a quali ed engineer or architect, to determine their suitability for a speci c use. OEG Building Materials assumes no liability for failure resulting f rom use or misapplication of computation,
details or speci cations contained herein. OEG Building Material assumes no liability for damages resulting f rom improper application or insulation of these products.
OEG BUIL DING M ATERIAL S - M ETAL FRAM ING M ANUFACTURERS

6001 BORDENTOWN AVE, SAYREVIL L E, NJ 0887 2

P 7 32.667.3636 I WWW.OEG USA.COM I ORDERS@ OEG USA.COM

ALLOWABLE UNIFORMLY DISTRIBUTED LOADS (PSF)

Span Length(ft) 5.0 5.5 6.0 6.5 7.0 7.5 8.0 8.5 9.0 9.5 10.0

Span Cond. KSI S D S D S D S D S D S D S D S D S D S D S D

1-SPANS 40 136 100 112 75 94 58 80 46 69 37 60 30 53 24 47 20 42 17 38 15 34 13

2-SPANS 40 142 242 118 181 99 140 84 110 73 88 63 72 56 59 49 49 44 41 39 35 36 30

3-SPANS 40 178 189 147 142 124 109 105 86 91 69 79 56 69 46 62 38 55 32 49 28 44 24

1-SPANS 50 169 100 140 75 118 58 100 46 86 37 75 30 66 24 59 20 52 17 47 15 42 13

2-SPANS 50 178 242 147 181 124 140 105 110 91 88 79 72 69 59 62 49 55 41 49 35 44 30

3-SPANS 50 222 189 184 142 154 109 132 86 113 69 99 56 87 46 77 38 69 32 62 28 56 24

NOTES:
Load tables are calculated using section properties based on the steel design thickness.
Loads shown in tables are uniformly distributed loads in psf. Span length assumes center-to-center spacing of supports. Tabulated
loads shall not be increased by assuming clear span dimensions.
All construction load spans are calculated using a 200 pound service load on a 1 foot width of deck, in accordance with ANSI/SDI RD-
2017.
Deck de ection should be checked in accordance with ANSI/SDI RD-2017.

DISCAIMER:
All data, detail and speci cations included in herein are intended as a general guide for using OEG Building Materials products. These products should not be used in design or construction without
evaluation by a quali ed engineer or architect, to determine their suitability for a speci c use. OEG Building Materials assumes no liability for failure resulting f rom use or misapplication of computation,
details or speci cations contained herein. OEG Building Material assumes no liability for damages resulting f rom improper application or insulation of these products.