Professional Documents
Culture Documents
15BD358
15BD358
PHYSICAL PROPERTIES
Deck Type B Deck
Design Thickness 0.0358
Weight 2.1
Coating G60
SECTION PROPERTIES 40 KSI
Ip (In4) 0.191
In (In4) 0.2104
Sp (In3) 0.2122
Sn (In3) 0.2247
NOTES
All section properties and ASD (Ω = 1.67) uniform loads are calculated in accordance with ANSI/SDI RD-2017 and AISI S100-2012 and
AISI S100-2016.
All section properties and strengths are reported per foot of panel width.
p = Property in positive bending; n = Property in negative bending.
Complies with the 2015 International Building Code and AISI S100-12
Zinc-Coated (Galvanized) sheet metal meets or exceeds ASTM A653 and ASTM A1003
DISCAIMER:
All data, detail and speci cations included in herein are intended as a general guide for using OEG Building Materials products. These products should not be used in design or construction without
evaluation by a quali ed engineer or architect, to determine their suitability for a speci c use. OEG Building Materials assumes no liability for failure resulting f rom use or misapplication of computation,
details or speci cations contained herein. OEG Building Material assumes no liability for damages resulting f rom improper application or insulation of these products.
OEG BUIL DING M ATERIAL S - M ETAL FRAM ING M ANUFACTURERS
Span Length(ft) 5.0 5.5 6.0 6.5 7.0 7.5 8.0 8.5 9.0 9.5 10.0
NOTES:
Load tables are calculated using section properties based on the steel design thickness.
Loads shown in tables are uniformly distributed loads in psf. Span length assumes center-to-center spacing of supports. Tabulated
loads shall not be increased by assuming clear span dimensions.
All construction load spans are calculated using a 200 pound service load on a 1 foot width of deck, in accordance with ANSI/SDI RD-
2017.
Deck de ection should be checked in accordance with ANSI/SDI RD-2017.
DISCAIMER:
All data, detail and speci cations included in herein are intended as a general guide for using OEG Building Materials products. These products should not be used in design or construction without
evaluation by a quali ed engineer or architect, to determine their suitability for a speci c use. OEG Building Materials assumes no liability for failure resulting f rom use or misapplication of computation,
details or speci cations contained herein. OEG Building Material assumes no liability for damages resulting f rom improper application or insulation of these products.