Índice Área de Mantenimiento de Patio de Contenedores: Horizonte 1: 100
Índice Área de Mantenimiento de Patio de Contenedores: Horizonte 1: 100
550
Patio de Carga General
5350
Contenedor vacío / pesado y OGG Patio de Carga General
28800
2 Point C
Point D 7@4000=28000
Índice
3000 1:4000 Área de mantenimiento de patio de contenedores
6981 20000 4019
31000
100
3 3
Geotextile(150g/cm -200g/cm )
50~80
Soil Classification First Maintenance
Minimum 254mm Minimum 305mm Expansion joint
Spreading Spreading
320
Sika Dust Seal Sika Dust Seal
260
1/m 2 1/m 2 Structure of expansion joint of
1:20
Mainly dust suppression of cement stabilized crushed stone
7@4000=28000 3000
Structure of two overlapping construction joint
1:20
31000 of cement stabilized crushed stone
1-1
Horizonte 1: 100 4000
Vertical 1:40
260
C32/40 Concrete Slab 350mm
5@300=1500
Cement Stabilized Crushed Stone 150mm
60
175 175
180
4000
6@300=1800
5350
260
Layout plan of dowel in joints
1:40
0 ISSUED FOR CONSTRUCTION 2021-05-10 Zhang Yong Chang Zhanwei Wu Zhefeng NOTES: PROJECT: DRAWING TITLE: SCALE :
CLIENT: DESIGNER : 1.Dimensions are in millimeters, except where indicated. A1: 1:20
F For Revision 2020-10-20 Zhang Yong Chang Zhanwei Wu Zhefeng 2.This project should be carried out after the underground construction is completed. A3: 1:40
E For Revision 2020-09-21 Zhang Yong Chang Zhanwei Wu Zhefeng 3.Characteristic yield strength of reinforcement and dowel is not less than 420MPa.
D For Revision 2020-08-18 Zhang Yong Chang Zhanwei Wu Zhefeng 4.The bending strength of concrete is 5.5MPa, and the bending modulus is 33GPa. Chancay Multipurpose Terminal New First Stage, Peru DATE :
C For Revision 2020-04-09 Zhang Yong Chang Zhanwei Wu Zhefeng 5.Dowels in slabs with other dimensions than 4m X 4m and odd-sized slabs shall be arranged in the same dowel spacing and
Slab Division Drawing 2021-05-10
中远海运港口秘鲁钱凯公司 2020-03-30 Zhang Yong Chang Zhanwei Wu Zhefeng length compared with those in 4m X 4m slabs. Detailed Engineering For Container Yard Maintenance Area
COSCO SHIPPING Ports Chancay PERÚ S.A. CCCC Water Transportation Consultants Co.Ltd B For Revision CODE : REVISION:
Rev. DESCRIPTION DATE BY. CKD. APD. AUD. 6.Dowels shall be coated with a bond-breaking substance to prevent bonding to the PCC during the construction period.