Professional Documents
Culture Documents
Environmental Impact Assessment For Infrastructure Development Project in Chennai
Environmental Impact Assessment For Infrastructure Development Project in Chennai
---------------------------------------------------------------------***-------------------------------------------------------------------
Abstract - Environmental impact assessment study Assessment (REIA) study and to prepare the
for medical and engineering colleges in Chennai- Environmental Management plan for the proposed
development for obtaining the Environmental Clearance
Tamilnadu. Based on the TOR issued by the SEIAA, the
for their proposed building construction project from the
Rapid Environmental Impact Assessment Report has State Environmental Impact Assessment Authority
been prepared for the Existing and Proposed expansion (SEIAA), Chennai.
of Institution, “Deemed University” (Medical College &
Hospital Engineering College, College of Engineering & 1.1 Land Details
Technology and School of Architecture) at S.Nos. 78/3,
79, 80, 81, 82/1, 82/2, 83/1A, 83/2, 84, 85/2, 86/4B, Table-1 – Land details
88/1, 88/3, 299 of Mevalurkuppam Village and S.Nos.
300, 301, 302, 303/1, 303/2, 303/3, 303/5, 304, Land Description:
305/3B, 305/3B, 305/4, 306, 308 of Chettipedu Village,
5,03,914.56 Sqm (124.51
Sriperumbudur Taluk, Kanchipuram District by Medical Total Plot area (Sqm)
acres)
and Educational Trust. Major environmental attributes
has considered identifying the Impacts and providing Total Built up area (Sqm) 2,90,710.17 Sqm
solutions with mitigation measures. Mainly covered
Water, noise and solid waste management sector. S.Nos. 78/3, 79, 80, 81, 82/1,
82/2, 83/1A, 83/2, 84, 85/2,
Keywords: Water, Noise, solid waste, impact, mitigation 86/4B, 88/1, 88/3, 299, 300,
Plot/Survey/Khasra No
measures & EIA 301, 302, 303/1, 303/2, 303/3,
303/5, 304, 305/3B, 305/3B,
305/4, 306, 308
1. INTRODUCTION
Mevalurkuppam & Chettipedu
One of the Medical and Educational Trust proposes to Village
expand its Institutional Buildings in Mevalurkuppam & villages
Chettipedu villages, Sriperumbudur Taluk, Kanchipuram
District in the state of Tamil Nadu. The project proponent Taluk Sriperumbudur Taluk
proposes to obtain Environmental Clearance for the land
area of 5, 03,914.56 Sqm (124.51 acres) and the built up District & State Kanchipuram & Tamilnadu
area of 2, 90,710.17 Sqm (Existing Buildings – 2, 48,516.13
Sqm & Proposed Buildings – 42,194.04 Sqm). The
proposed project falls under 8(b) category as per MoEF,
EIA Notification, and 14th September 2006. Hence it is
required to submit TOR and Rapid Environmental Impact
Assessment (REIA) study as per State Environmental
Impact Assessment Authority, Chennai.
2.1 Project Location The project site is owned by Medical and Educational
Trust, Chennai. The project site is in Mevalurkuppam &
Picture-1 – Location info Chettipedu villages and it is classified as Primary
Residential Zone by the Chennai Metropolitan
Development Authority. The site selection was done based
on proximity to local communities, existing drainage
pattern, ecologically sensitive areas, Geo technical report
has been covered in the EIA study.
Total Non
Total Bio
Required/Lim Total solid Bio
Degradable
it IS Waste Degradable
W1 W2 W3 Description Waste
S. Parameter 10500/2012 generation Waste
Mg/ Mg/ Mg/ generation
No s Kg/day generation
l l l Kg/day
Req Permi Kg/day
uire ssible
Medical 2211 1327 885
pH at 6.5- -- College and
1 7.0 7.10 7.20 Hospital
25ºC 8.5
5 Sodium 78 62 78 -- 92 55 37
School of
6 Potassium 4 2 3 -- Architecture
45 No
8 Nitrate 8 2.5 11
Relax Per capita solid waste generation for residential is 0.6 kg /
capita / day and for other working population it is 0.2
Calcium 75 200 kg/capita/day.
9 26 21 79
(as Ca)
Source: Central Public Health and Environmental
Magnesiu 30 75 Engineering Organization (CPHEEO).
10 52 12 30
m (as Mg)
3. RESULTS AND DISCUSSIONS
Sulphate -- --
11 42.1 39 57
(as SO4) 3.1 study about impacts and Mitigation Measures
Total 45 No As seen from the water quality result Table, Calcium and
12 BDL BDL BDL
nitrogen Relax Magnesium content varies between 79 to 21 mg/l and 52
to 12 mg/l respectively.
BDL 0.16 BDL -- ---
Total
Total hardness and alkalinity expressed as CaCO3 ranges
13 phosphor
(DL: (DL: between 340 to 150 mg/l and 186 to 152 mg/l
us 0.1) 0.1) respectively. The study area is fast developing commercial
and residential area the extraction of ground water is
14 DO 5.5 6.0 5.4 4.0 --
envisaged in huge quantity, the proper rain water
harvesting and storm water drains has been designed in
the project site to increase the recharge potential of rain
water to increase the level of ground water and to improve p = permeability factor
the quality of ground water in the core area.
r = rainfall intensity in m / yr.
Water Requirement/Usage Summary:
Hence, total volume of rainwater run - off will be : (a) +
Total water requirements : 1102.69 KLD (b) + (c) = 1, 36,468 Cum. /yr
Total Daily fresh water required : 689.73 KLD Run-off during peak rainfall is (considering rainfall rate of
100mm/ day) = 11,372 cum/day
Daily fresh water requirement for Domestic use
: 589.73 KLD However, the rainwater collection drain and recharge pit
Daily fresh water requirement for Lab & is designed for highest hourly peak flow according to the
Operation Theatre use : 72.00 KLD site condition.
Daily fresh water requirement for Laundry use
: 28.00 KLD Rain Harvest Pit - Roads / pavements and
Water requirement for flushing : 412.97 KLD
landscape
Gardening water Requirement : 270.00 KLD
Table-8
Actual water requirement for Gardening:
Rainfa
Coeffic Total
Area for Green belt development × 3.5 lts Area ll
ient Rainwate
Description intens
= 77,038.88 Sqm × 3.5 lts/ Sqm = 269636.08 lts in Sqm r Runoff
runoff ity in
Cum.yr
m
Rainwater Management:
Roof area 71,513 0.90 1 64,362
Rain Harvest Pit - Roads / pavements and
landscape: Roads & 1
70,463 0.75
Pavement 52,847
Design parameters:
Landscape & 1
77,038 0.25
Total Plot Area considered : 5, 03,914 Sqm. Green Area 19,260
Total bio waste generation : 0.20 Tons/day Environmental Management plan is a vital process of any
management plan of the development project. This helps
OWC model proposed : OWC 300 in signaling the potential problems that resulting from the
proposed project and will allow for prompt
Waste treatment per batch : 125 kg
implementation of effective corrective measures. The
Time taken for each batch : 15 - 20 min environmental monitoring will be carried out for the
construction and operational phases.
Table-9 – Nature of waste
Non
Sent to authorized recyclers
2 biodegrad 1.79 3 Ambient Noise Once in three month
or local bodies for disposal
able waste Level
4. CONCLUSIONS BIOGRAPHIES