Weight load control instrument

A)Overview
DTZZIII-type weight load controller has a reasonable structure, easy installation, simple
debugging, seismic anti-interference ability, high precision, stable and reliable performance
characteristics. The controller uses three digital display, intuitive image, user-friendly
operation. The load value can be set freely according to the customer's needs, easy to use

B)Main technical indicators,


1)Power supply voltage: AC220 (-15- + 10%) V
2)Integrated error of not more than 1, the control of the use of digital LED easy to use, : 5%
3) Operating temperature: -10- +60 ℃
4)Sensor overload capacity and sealing level:
safety overload 150%
FS limit overload 300%
FS sealing degree IP67
5) Relay output contact capacity: 74 / DC243. ; SA / AC220V
6) Alarm control point:
 Static warning alarm point: 90% of the rated load (factory settings), sound
and light alarm
 Static overload alarm point: rated load of 105% (factory settings), sound and
light alarm.
 Moment of cut off the king for the M dynamic limit alarm point: 150% of the
rated load (factory settings), sound and light alarm, Kawasaki cut off a circuit;
Note: strength beyond the limits listed above, the use of the system may lead to abnormal or
cause its permanent damage

C) Working principle
DTZZIII-type load cell will be converted into electrical signals into the electrical signal, the
transmission cable and control device connected by the control device to sum up v1A / D
converter, single-chip operation to achieve electronic weighing. When the weight of the
sensor reaches or exceeds the static warning alarm point setpoint, the controller on the
controller panel lights up and sounds an alarm. When the weight of the sensor reaches or
exceeds the static overload alarm point or the dynamic limit alarm point Set the value of the
corresponding control relay within the relay contacts and control system to achieve the same

D) System installation:

1) Controller shape And terminal function: machine lin sundan size b. Drawing instrument installation
accessories size in …
time control the purpose of the control panel on the corresponding full load "overload", LED
lights and issued a different sound alarm. Fourth, the system installation 1, the controller
shape and terminal function: Chassis dimensions 10a 25 0 ° cS

a) The controller can be mounted in the control cabinet and connected directly to the
control cabinet with two M6 thrusters as shown in Figure 2a: if needed to be installed
elsewhere. You can fix the two mounting accessories shown in Figure 2b to the rear
of the control, and then install the control to the desired location.

b) Terminal function:
1-4: NC;
5: 24V +;
6: set +;
7: set -;
8: GNDI);
9: NC:
10: dynamic limit alarm point normally open;
11: dynamic limit alarm point often Closed point;
12: dynamic limit alarm point common point;
13: static overload alarm point normally open point;
14: static overload alarm point normally closed point;
15: static overload alarm point common point;
16: idle;
2) Sensor wiring :
The controller and the sensor are connected by a special plug, and the
connection way of the sensor plug is:
Plug-pin sensor line
Pin 1-------------signal +
Pin 2-------------power-
Pin 3-------------signal –
Pin 4-------------power +
E) Parameter setting and debugging
Parameters set method
1) Set the parameters before the first 5 and 6 terminals, 7 and 8 terminals were shorted
(set up after they are disconnected, Pull the switch to the "set" position, to the
instrument connected to the power .
2) Digital tube shows "5", then press the clear button, digital tube display: 5-10,
where:
"5" for the load to set the parameters, the cycle shows : 1-250, on behalh
of 1%-250%
"6” Adjust the dynamic limit alarm point action value, the cycle shows:
100-250, on behalf of 100% -250%;
"7" Adjust the static overload alarm point action value, the cycle shows
60-150, on behalf 60%-150%
"8" Adjust the static warning alarm point action value, the cycle shows:
20-100, on behalf of 20% -100% for the static overload alarm point
action value
"9" Adjust the static overload alarm point delay coefficient set value, 0-
100, on behalf of 0%-100%;
"10" For the equipment rated load, the cycle shows: 5-50 on behalf of 0.5-5
ton.
Adjust the dynamic limit alarm point action value as an example, the digital tube
display transferred to "6", waiting for a moment, hear the two buzzer C ring
At this time, the digital tube displays the dynamic limit alarm point action value of the
current device.
At this time, press the clear switch, and the digital display is displayed from "80" and
"180". When the display stops at the value to be set , Will pull the switch to the "run"
position, then display as "841", said the input is complete

3) Re-power to the device, set up. The other options are set up in the same way.

Debugging
Method 1,
When the scene has a rated load weight, the following methods can be debugged:
(the first operation is recommended to use this method for debugging)

(1) The controller on the functional terminals connected to the control system, 5
and 6 terminals, 7 and8 terminals are shorted (they are disconnected after
commissioning)

(2) Lift the bottom of the cage.

(3) Set the switch to the "RUN" position, so that the instrument enters into the
detection state.

(4) No-load clear (Press the reset button for more than 5 seconds, hear after a
long sound, inmediatly release. The digital tube shows the actual weight 0.00)

(5) Load the rated load, press and hold clear Button for more than 5 seconds,
hear a long sound immediately after the release, the digital display of the
actual weight.

(6) The controller power, and then re-power, debugging is completed.


Method 2,
when the scene does not have enough weight, you can use a lighter weight to
complete the debugging.
The specific process is as follows: Assuming the "10" item is "20, that is, the
equipment rated load of 2ton, and the scene only 1000KG weight, the learning
process is this:
(1) The cage in the bottom of stability, the implementation of clear
operation
(2) After the completion of the clear, the 1000KG weight into the cage. set
(3) Press and hold the clear button for about 5 seconds, the instrument
issued a long ring, the instrument displays "2.00" (the display content
due to the rated load)
(4) Go to option “5” according to the following formula
“5” item setting = rated load / learning weight * 5 “item display value is
50,
into the formula: “5” item set value= 20000/1000*50, set value of “5”
= 100
(5) Set the “5” option to 100, exit the setting state and power on again
(6) At this time the instrument is displayed as "2.00" and the rated load is
set to 2t

Note: The weight of the learning weight should not be less than 40% of the rated load. Due
to the difference between the site installation and the rated load, There may be a large error,
when this happens, in order to ensure the measurement accuracy is recommended to use
the weight of the rated load weight for debugging.

F) User Note:
1. Do not sprinkle water in the controller terminal blocks and circuits board.
2, Do not use the organic solvent to wipe the controller
3, Do not open the controller, if the controller can not be used normally, please
contact with my company.
Note: Damage caused by man-made control device, or unauthorized control
Instrument open, our company will not be responsible for product repair and
replacement

Backcover
Manufacturer: Qinhuangdao Development Zone Prospect Photoelectric Technology Co., Ltd.
Carrier: Qingdao Tongle Electronic Technology Co., Ltd. Address: Qingdao City, Qingdao,
China, 16 South China Building, 1119 # Sales Service Tel: 0532-87311706 / 87317087
13697653069 Technical Support Tel: 13697653069 13933589838

You might also like