Download as pdf or txt
Download as pdf or txt
You are on page 1of 1

REMATE FINAL O GOTERO

0.10 TABIQUE COLOCADO DE SOGA COLUMNA C-A


DE 10X20X40 CM
0.
20 ZANJÓN PASA A 1.40 MTS DE LA COLUMNA EN ESQUINA.

02
2.82

0.
BLOCK "U" DE 15X20X40 CM 35 kg/cm2 EL CAUSE MARCADO ESTA A - 0.30 M.DEL NIVEL DE
0.20

2 FE No.3 + ESL. No.2 @ 0.15 m 3. REFERENCIA +-0.00 QUE ES LA SUFERFICIE NATURAL DEL

C - - T1
00

A
3.64

Z
0. TERRENO. VER DETALLE DE PASO DE AGUA DEL ZANJÓN

3. 0
24
2
2
3. 0

0.
00 0

20
nivel suelo nivel suelo 0. .20

0.
20

20
3.

01

C-
0.
00

3.

A
C- -T1
A
0.

pend.
block de 35 kg/cm2 2
3. 0

C- -T1
3. 0
01
2
0.15x0.20x0.40 m. 00

C-
A
0.20

0.

Z
N

A
1.06

0.

A
2

C-
0.42 0.42
Z
C- -T1 3. 0

3. 0
00 0

01
2
A Z
CI 0. .20

0.
0.20 MI C- -T1 20 54 nivel suelo
E A

A
0. 20
NT 3. .6

C-
00

C-
8

0.
0.20 O ml

3. 0

A
01
CO 0.

2
2 . co
1.40 0.50

C- -T1
RR 3. 0

O
ns

pend.
ID

ID

C-
O 00 tr

A
RR
0. uc

C- -T1
3. 0
SOLERA INTERMEDIA 4 FE No.3 ció

01
2

CO
A
3. 0

Z
Z

0.
2.82

+ ESTRIBOS No. 2 @ 15 CM PASO DE AGUA TUBO DE CONCRETO 12" TR C- -T1 n


ZAPATA T-1 00 de

TO
0.20

A
A Z
FUNDIDO CON ESPESOR DE 0.10 M.
AM 0. .20

0.20
C-
mu

EN
C- -T1 20 ro

3. 0
SOLO CORRE AGUA EN INVIERNO.

MI
O A

01
2
UNA SECCIÓN DEL TRAMO 2: PASO DE AGUA DEL ZANJÓN 3. pe

0.

CI
00
2

C-
rim

20

A
VE 0. et

A
C-
0.
ESC: 1/50 20 ra
R 3. l

20
01
00
EL

C-
0.
3.
0.50

A
0.

C- -T1
EV 2

A
3. 0

A Z
Z block de 35 KG/CM2
AC C- -T1 0

3. 0
0.

C- -T1
block de 35 kg/cm2 0

01
2
A Z
0. 20 0.15x0.20x0.40 m.

0.

Z
IÓ C- -T1

0.20
0.15x0.20x0.40 m. solera humedad 20
N

A
A 3.

C-

0.42
00
HO

C-
3. 0
0.10

01
2

A
0.
1.26

0.
0.10 JA 3. 0
2

pend.
0.42

A
0. 0.2
ZANJÓN SE SECA EN No 00

C-

C-
0.10
0.

A
.4

3. 0
VERANO UNICAMENTE EN 2

01
CI

2
SOLERA HIDROFUGA INVIERNO QUE CORRE AGUA M Z
C- -T1 3. 0
.

C- -T1
IE 00

O
NT
0. 0.20

A
A Z

ID
Z
4 FE No.3 + ESTRIBOS No. 2 @ 15 CM

l
0.20
O C- -T1

RR
ra
cimiento corrido 2

3. 0
3. 0

C- -T1
CO

01
2
A

CO
et

A
0.
RR

Z
00

rim

C-
3 FE Ø No. 4 +

TO
nivel suelo ID

A
0.

A
pe
O

C-

EN
2 EST. FE No.2 @ 0.15

0.20
3. 0

ro

20
PASO DE AGUA TUBO DE CONCRETO 12"

MI
01
00

mu

0.

C-
3.

CI
FUNDIDO CON ESPESOR DE 0.10 M.

A
0

20
ión
2. .20

A
SOLO CORRE AGUA EN INVIERNO.

0.

C-
Z
0.20

cc
C- -T1 03

20
ru
0.

01
A Z 2

st

0.
0

3.
C- -T1

C- 1
on

T
detalle vista frontal paso de agua del zanjón A

Z-
A
.c

C-
ml

20

C- T1

A
01
ESC: 1/25

0.

Z-
A
3.
0
0.42

0.40

.2
CIMIENTO CORRIDO:

C-

20
92

A
C-

A
3 FE No.4 + ESL No.2 @ 15CM
1.02

0.
A
3. 0

C-
01
2

00
0.

3.
.4
20

20
DO
A
C-
BASE PIEDRA BOLA FUNDIDA

0.

0.
0.20

detalle cimiento corrido

RI

A
No
3. 0

C-
CON CONCRETO PARA

OR
01

00
2
ZAPATA T-1

0.

C- -T1
C

3.
PROTECCIÓN DEL CIMIENTO

JA
ID
C- -T1

20
9 FE No.4 @ 0.10 M. ESC: 1/10

TO

A Z
RR
A
Z

0.
0.20

C- -T1
HO
0.30

EN
EN AMBOS SENTIVOS

CO
3. 0

C- -T1
01

Z
2

00
MI
0.

TO
Z

3.
N

CI

20
EN


A
C-

0.
MI

AC

A
0.90

3. 0

C-
CI
01
0.20

2
0.30

00
.
0.

pend
EV

3.
.
PEND.

20

.4

20
A

20
EL
0.

C-

0.
A

0.
PEND.

0.55

No
20

C-
01

00
0.

ER
3.
corte de muro tipio

C- -T1

3.
C- -T1

JA

20
0.90

A Z
A

1V
Z

0.
C- -T1
0.05

HO
3. 0

C- -T1
ESC: 1/20

01

00
2

O
0.
0.20 0.65

Z
0.33

3.
AM

EN

20
A

0.
C-

TR

A
3. 0
TUBO 12" FUNDIDO EN CONCRETO

l
N
01
2

C-

ra
00
0.
CON ESPESOR 0.10 M.

et
3.

0.20
VER DETALLE VISTA FRONTAL

rim
20
20

AC
DO

O
C-

ID

0.
0.

mu 0
pe
A
I
BASE PIEDRA BOLA FUNDIDA CON CONCRETO

RR

2
RR

C-
3. 0

EV

0.
01

00
2

ro
CO
0.

CO
PARA PROTECCIÓN DEL CIMIENTO

C- -T1

3.
EL
C- -T1
NACIMIENTO DE AGUA, FLUIDO SE

20
A Z
O
A

TO
ZAPATA DE 90X90 CM CON

de
NT

0.
MANTIENE LOS 365 DIAS DEL AÑO

C- -T1
EN
R
3. 0

E
9 FE No.4 EN AMBOS SENTIDOS

n
C- -T1
01

0
2

Z
MI

ció
VE

MI

0
0.

0.90
Z

3.
CI

uc
CI

20
A

0.65
tr
3
C-
DETALLE VISTA EN PERFIL PASO DE AGUA DEL ZANJÓN

0.

ns
A
3. 0

C-
.
01
2

co
00
pend
0.

AM
ESC: 1/25

3.

de
20

20
DE ESTE PUNTO HACIA EL SUROESTE
A

TR

.
0
C-

ml
0.

0.

2
A

0.
CORRE AGUA DURANTE TODO EL AÑO
3. 0

C-

.13
01

00
2
0.

C- -T1

3.

49
C- -T1

A
Z

20
A

O
Z

ID

0.
C- -T1

0.05
RR
C- -T1
3. 0

A
01

00
2

Z
JUNTA DE DILATACIÓN
A
0.

CO

3.

0
O
A

2
NT
C-

0.
A
C-
E
01

00
MI
3.

DETALLE ZAPATA T-1

3.
CI

COLUMNA C-A COLUMNA C-A

DO

20
A
C-

20
I

0.
0.20X0.20 M. 0.20X0.20 M.

RR

A
ESC: 1/20

0.
20

C-

00
CO
0.

3.
C- -T1

20
A
A

NT
Z

C-

0.
IE

9
M

0
CI

3.
SOLERA BLOCK "U"

20

0.20
.
REFORZADA CON 2 FE No.3 +

pend

0.
ESLABONES No.2 @ 15CM

0.15

ZANJÓN

.
pend
0.15

detalle solera final


ESC: 1/10 4 ø 3/8" + est.

0.20
de ø 1/4" @ 0.15 mts.

0.20
.
pend

detalle solera hidrofuga y intemedias


3.44

CA

REFUERZO ESTRUCTURAL ESC: 1/10


LL

0.20
4 FE DE Ø No. 4"
E

EST. 1/4"@ 0.15 M.

detalle COLUMNA C-A


HA

.
nd
CI

pe

ESC: 1/10
A

U.
CA

ULE
ALH
RR

ET
NR
ET

IA
AST
ER

SEB
SAN
A

LUIS FECHA INICIO:


SAN
7.
50

L D EA AGOSTO 2,018
A
M.

NOMBRE PROYECTO:
PLANTA ACOTADA Y DE CIMENTACIÓN MURO PERIMETRAL DIBUJO Y DISEÑO: CONSTRUCCION MURO PERIMETRAL
ESCUELA PRIMARIA, CASERIO RECINOS,
RL&GM ALDEA SAN LUIS, SAN SEBASTIAN RETALHULEU.
0.20 0.20 ESC: 1/250
CONTENIDO
0.20

CIMIENTO CORRIDO CIMIENTO CORRIDO


PLANTA ACOTADA Y DE CIMENTACIÓN MURO PERIMETRAL
DETALLES DE CIMENTACIÓN
CORTE DE MURO TIPICO
0.20

0.20

0.90 0.90 ESCALA: HOJA No.


ZAPATA T-1 ZAPATA T-1
INDICADA 3
4
junta de dilatación
JUNTA DE DILATACIÓN

DETALLE JUNTA DE DILATACIÓN EN COLUMNA C-A DOBLES


DETALLE DE JUNTA DE DILATACIÓN COLUMNAS Y ZAPATAS DOBLES. ESC: 1/10

ESC: 1/20 FIRMA

You might also like