Cerberus ECO
enjoy protecting
Product Brouchure

siemens.com/buildingtechnologies
Cerberus ECO
enjoy protecting
Lives and businesses deserve reliable protection from the risk of fire, and in
Siemens’ Cerberus ECO you can benefit from such protection by the system’s
exceptionally smart and powerful fire detection product series. Cerberus ECO
has specifically been designed with small to medium premises in mind -
including commercial buildings, hotels, shopping arcades, residential and a
host of similar enterprises.

With more than 160 years of Siemens fire safety expertise to draw upon,
Cerberus ECO incorporates key state-of-the-art global technologies that are
second to none. The products and system adopt simple maintenance and
operation design concepts in order to keep installation and commissioning as
straightforward as possible. Cerberus ECO delivers dependable fire detection
and alarm signalling, while maximising the protection of individuals, buildings
and assets.

2
ECO product range
Smart and designed for simple
installation and maintenance
Designed for simple installation, Putting you first Highlights
maintenance and operation - Service is part of the package
(SIMO design concept) Siemens recognises that pre-sales and ■■  eliable product –
R
Tailored for the needs of users in small after-sales services are essential for reli- incorporates key state-of-the-
art global technologies and
to medium sized businesses for simple, able fire detection products, which is why
Siemens’ high quality
cost-efficient protection, Cerberus ECO Cerberus ECO comes with a series of valu- standards
has adopted simple installation, main- able service offerings for both installers
tenance and operation design concepts and users. To support users to effortlessly ■■  igh cost-effectiveness –
H
affordable by small to medium
for the products and system that take install and operate the system, Siemens
sized businesses
into account the complete working cycle offers a customer hotline, e-training, and
of installers and users. quick and reliable logistics. ■■  mart design –
S
for simple installation, mainte-
International quality product Powerful networking nance and operation
Cerberus ECO has been specially Cerberus ECO installation grows with you. ■■  ser-friendly operation –
U
developed by a dedicated SMART R&D So should you want to extend or convert expandable and compatible
team based in China, a strong centre of your building, Cerberus ECO installation with future developments
competency for SMART products (Simple, can be easily expanded.
Maintenance-friendly, Affordable, Reli-
Free wiring topology
able, Timely-to-market). This ECO product
Cerberus ECO enables you to achieve
series incorporates key state-of-the-art
higher cost-effectiveness by optimising
global technologies and system architec-
installation and maintenance costs via
ture, while complying with Siemens’ high
free wiring topology.
quality standards.
Smart devices
Complete product range
- Innovative features
- A wide range of applications
Devices in the Cerberus ECO product
Cerberus ECO’s compact and com-
series are equipped with numerous
plete range of cost-efficient fire safety
powerful features for easy installa-
products - tailor-made to protect your
tion and commissioning. The dust and
staff, buildings and assets - comprises fire
dirt compensation feature and ‘Sticker
detectors as well as control panels and
method’ installation for detectors,
peripheral equipment such as manual call
360-degree viewable alarm indicator, PC-
points, and input and output modules.
free commissioning on panel with large
Cerberus ECO is the reliable choice for a
easy-to-read LCD monitor, and easy-to-
wide range of applications whether they
use menu button on panel, are just some
are for commercial buildings, hotels,
of the innovative features of this system.
shopping arcades, commercial, residen-
tial or similar enterprises.

3
FC18 Control Panel Range
Highlights Highly user-friendly panel range Flexibility - File handling
A new range of control panels (FC18) Cerberus ECO incorporates a series of fea-
■■  ighly user-friendly panel
H with three panel options - FC1820 (≤ tures to support flexible file handling to
range with three panel 252 points), FC1840 (≤ 504 points) and reduce commissioning costs:
options.
FC186x (504 - 1,512 points) - are offered
• Configuration file can be exported to
■■  uick and accurate program-
Q in the highly user-friendly Cerberus ECO
ming via PC or on panel with and imported from Excel file.
product series, which makes installation,
large 320 x 240 pixels LCD • No re-configuration / re-download of
operation, integration and maintenance
monitor. configuration file necessary following
easier than ever.
■■  asy-to-use menu button to
E
firmware version updates.
call out pull-down menu for Cerberus ECO provides the flexibility you • ‘Download & Upload priority’ enables
swift testing, commissioning, need for system expansion, modernisa- uninterrupted download and upload
configuration, event manage- tion and backward-compatibility innova- process.
ment, monitoring and report tion, and enables you to achieve higher • History record can be uploaded from
handling. cost-effectiveness by optimising installa- panel to PC to accommodate ‘Expand-
■■ 
Flexible file handling simpli- tion and maintenance costs with flexible able archiving’.
fies commissioning and wiring technology. This new panel stubs • ‘Customer report’ file with information
reduces costs. on loop as well as star style field bus on all devices mounted on site can be
topology and free polarity wire connec- exported.
■■ 
Easy programming and com-
tion. Each panel can monitor and operate
missioning enabled by innova-
tive tools and functions. from 252 to 1,512 devices and enables Easy programming and commissioning
networking with up to 32 panels. Innovative tools and functions to simplify
and reduce the time for programming
Programming - PC or Panel
work, such as:
The Cerberus ECO FC18 control panel
range supports programming via PC or • ‘Unique ID code’ for each peripheral
panel. Equipped with a large 320 x 240 enables easy localization and lifecycle
pixels LCD monitor, programming work is identity.
rapid and accurate. • ‘Logical expression name’ to enhance
readability.
Easy-to-use - Menu button on panel
• ‘Group programming’ function to
An easy-to-use menu button is available
simplify logic relations.
on the FC18 control panel range. Test-
• ‘Multi-device-select’ function enables
ing, commissioning, configuration, event
assignment of multiple devices in one
management, monitoring and report
group.
handling are all easily accomplished by
• ‘System copy & paste’ function for easy
simply pushing the menu button to call
merging of configurations by different
out the user-friendly pull-down menu.
technicians.
4
FD181 device range
Complete range of devices Protective caps and Highlights
A complete range of devices (FD181) are dust/dirt compensation
offered in the Cerberus ECO fire detection Eye-catching protective cap in red is avail- ■■  dvanced communication pro-
A
product series, including smoke and heat able for the protection of smoke detector tocol assures fast & accurate
fire detection
detectors. Dual-channel input module during the installation period. Together
and dual-channel input/output module with a dust/dirt compensation feature, ■■  omplete range of devices
C
with open/short circuit monitoring, floor greatly facilitate smoother installation with smart designs
repeat terminal for easy access of alarm work and reduce costs. ■■ L ogical ‘Sticker method’ instal-
information, re-settable manual call lation via unique device ID
Strict enforcement of sticker
point, collective input module, and an
environmental standard
isolator module are also provided as part ■■  etector protective caps and
D
In deference to the environment, all
of the comprehensive package. dust compensation feature
detectors are RoHS compliance.
facilitate smoother installation
Fast & Accurate fire detection and reduce costs
Benefit from Siemens advanced com-
munication protocol from global R&D
team, which assures quick identify-
ing of fire dangers and reliable signal
transmission.
Logical ‘Sticker method’ installation
The detectors are designed for easy com-
missioning by logical ‘Sticker method’
installation. Each detector has a unique
device ID sticker attached at the back
that can be positioned on project draw-
ings for quick and accurate testing and
commissioning.

5
Cerberus ECO System overview
Powerful control panels, smart detectors and complete peripheral
devices. Cerberus ECO fire detection product series supports FDO181C
powerful networking and provides a smart choice for reliable Collective Smoke Detector

protection.
FDT181C
FXS1800
Graphic Display Equipment Collective Heat Detector
programming tool

FDO181 FDCI183 FDM181


FDCL181
Smoke Collective Manual
line separator
detector Input Module Call Point

Horn / Strobe Horn / Strobe


NAC circuit FDO181 FDT181 FDM181
FDCL181
Smoke Heat Manual
line separator
detector detector Call Point
FC18-FC1820
FT1810 Fire alarm controller
Floor Repeater Display (252 points)

FTM1811
Mimic Display Board
FC18R-FC186x
FC18-FC1840 Fire alarm controller
Fire alarm controller FC 18-BUS Controller Network (504-1,512 points,with
(504 points, with BDS line card) BDS line card))

FT1810
FR18-BUS Floor Repeater Display
Floor Repeater FR18-BUS
Horn / Strobe Horn / Strobe
Display Network Floor Repeater
Display Network
Horn / Strobe Horn / Strobe
NAC circuit
FDCIO181-1
NAC circuit
I/O module
FDO181 BDS221A
Smoke detector Output Module

BDS132A
Input Module FDCL181 FDO181
FDCI181-1 FDCL181 Line Separator Smoke detector
Input module
FD18-BUS FDT181
BDS031
Line
Separator
Detection Heat detector
Heat
Detector FDO181C FDCI183 FDCI181-2
Network BDS051
Collective Collective Input Input module

FDCI181-2 Smoke
Smoke
detector
Module FD18-BUS
Input module FDM181
Manual Call Point
Detector
FDO181 Detection FDO181
BDS121A
Manual
Smoke detector
Network Smoke
detector
Call Point FDT181C FDM181
FDCL181 Collective Manual Call Point
FDO181
Line Heat detector FDT181
Smoke
Separator FDCL181 FDCL181
detector FDCAI181 Heat detector
Line Separator Line Separator
alarm indicator FDCIO181-2
I/O module

■ FC18-BUS Controller Network ■ FR18-BUS Floor Repeator Display FDO181 FDO181


Cerberus ECO FC18 panel range enables Network Smoke Smoke
detector detector
interlocking with up to 32 FC18 panels via A floor repeater display can be connected
FC18-BUS. via FR18-BUS for remote monitoring to
FDT181 FDT181
further reduce costs.
■ FD18-BUS Detection Network Heat detector Heat detector

Each FC18 panel - FC1820, 1840 or 186X - ■ NAC circuit


enables monitoring and operating from ECO control panels have built-in NAC (No- FDCAI181 FDCAI181
252 to over 1,512 devices via FD18-BUS. tification Alarm Control) alarm output. It alarm indicator alarm indicator
This new panel range supports from one can be directly connected to notification
loop to eight loops configuration, stub on alarm devices such as horn or strobe.
loop as well as star style field bus topolo-
gy and free polarity wire connection.
6
Cerberus ECO at a glance
Control panels

Type FC1861 / FC1862 / FC1863 FC1840 FC1820

Description Fire alarm controller Fire alarm controller (504 points) Fire alarm controller (252 points)

Loop, stub on loop or star style field bus topology, free polarity wire connection, interlocking up to 8 panels, easy-
to-use menu button, programmable from PC or Panel
Features 2 loops / 4 loops / 6 loops
504 devices / 1,008 devices / 1,512 2 loops, 504 devices 1 loop, 252 devices
devices
Detectors

Type FDO181 FDT181 FDO181C FDT181C

Addressable Smoke detector Addressable heat


Description Collective smoke detector Collective heat detector
(with protective red cap) detector

Easy commissioning by Easy commissioning by Collective detector, no Collective detector, no


Features ‘Sticker method’ installation, ‘Sticker method’ address setting, polarity address setting, polarity
with dust compensation installation free connection free connection

Addressable modules

Type FDCI183 FDCI181-2 FDCIO181-2 FDCL181 FDCI181-1 FDCIO181-1

Collective Input
Description Input module I/O module Line Separator Input module I/O module
Module

1 monitored inputs
Dual-channel Dual-channel
Features as collective detec- -
Input Input/Output
tor connection

Resettable manual Floor repeater


Mimic Display Board Alarm indicator
call point display

Type FDM181 FTM1811 FT1810 FDCAI181

Description Manual Call Point Mimic Display Board Floor Repeater Display Alarm indicator

60 outputs for LED Connected via FR18-BUS Indicate quickly the source
Features With reset function
activation for remote monitoring of an alarm signal

7
Siemens Switzerland Ltd
Infrastructure & Cities Sector
Building Technologies Division
International Headquarters
Gubelstrasse 22
6301 Zug
Switzerland
Tel +41 41 724 24 24

The information in this document contains general descriptions of technical options available,
which do not always have to be present in individual cases. The required features should therefore
be specified in each individual case at the time of closing the contract.
© Siemens Switzerland Ltd

Answers for infrastructure.


Our world is undergoing changes that force us to think growing. For our customers, success is defined by how
in new ways: demographic change, urbanization, global well they manage these challenges. Siemens has the
warming and resource shortages. Maximum efficiency answers.
has top priority – and not only where energy is concerned.
In addition, we need to increase comfort for the well-being “We are the preferred partner for energy-efficient,
of users. Also, our need for safety and security is constantly safe and secure buildings and infrastructure.”