Salient Features of DPK Gensets

You might also like

Download as pdf
Download as pdf
You are on page 1of 1
Lo?) DPK SALIENT FEATURES OF DPK DG SETS WITH VOLVO EICHER ENGINES 1) Remarkable Fuel Economy with Unmatched En: more units/Itrs of diesel for each rating. Protections: generating 2) Service Interval of 500 Hours or 1 Year for 30-82.5kVA & 700 Hours or 1 Year for 100kVA to 160kVA (Lube Oil Filter / Fuel Filter / Lube Oil); Longer Service Interval of 500 Hours as against Competitors’ 50-100 Hours for first time. Major competition Service interval is 6 Months vis-a-vis 12 Months for VECV. 3) High Block Load Capacity: Excellent response to high capacity Load. 4) Deration of Power On Account Of Temperature: EICHER engines can operate at high ambient temperature i.e 50°C and higher altitude of 1000 MASL. 5) Air Filter Change & Coolant Change Period: FOR EICHER engines Air Filter Change Period is 2000 Hours/2 Years Vis-a-vis major competition recommends change period of 1000 Hours/1 Year and Coolant Change period is 4000/ 4900 running hours Vis-a-vis major competition recommends change period of 2000 Hours. However change of air filter also depends on dusty condition of site. 6) First Major Overhaul Of EICHER Engines: Is at 12000-14000 hours which is more than twice of its contemporary makes available in India, because of better metallurgy. 7) In-Built Oil Cooler: Ideal for Continuous Operation and Lower Lubricating Oil Consumption. Our Engines does not require regular interim oil top up. 8) In Line Fuel Pump: Eicher Branded Engines are having In Line Fuel pump across the Tange, having low maintenance cost and maximum uptime over rotary fuel pump. 9) Piston Cooling Jet: Increase Reliability; Lower Break Down & Maximum Up-Time. 10) Lubricating Oil Bye Pass Filter: Ideal for continuous operation. Increase Reliability, Bye Pass filter gets active once primary filter get chocked. 11) Starter Motor with Thermal Cut off arrangement: It helps to avoid the breakdown of Starter Motor which occurs due to over cranking. 12) Air Filter Choke Switch: This Feature is very vital as regards operation of Genset. In Case, Air Filter gets choked due to high dust. It gives visual indication on Air Filter. 13) Compact Size: Less Floor Area required for installation and ideal for installation where space is constraint 14)Commonality Of Spares Part: Our Radiator Cooled Gensets with Four & Six Inline Cylinders from 30 to 62.5KVA and 82.5KVA to 160kVA with commonality of major Spare parts 15) Extremely Low Vibration: Less Than 20 Microns whereas industry practice is less than 40 Microns below AVM. IDEAL FOR ROOF TOP INSTALLATION. 16) LOW NOISE LEVEL: Less than 72dba. SUPER SILENT.

You might also like