Model PT2000-H Series

Multi-channel Gas Monitor


& Data Logger

Gas Detection Systems

APPLICATIONS:
● Drilling Rigs
● Offshore Platforms
● Petrochemical Industry
● Chemical Storage
● Water & Wastewater Treatment
KEY FEATURES: ● LPG Storage
• Interface up to 64 detector trasnmitter. ● Refineries
Expandable to 96 channels
• 8” Color Touch screen
DESCRIPT ION
• 4 GB of data storage for historical data log and
event log Model PT2000/H Series is a PLC based gas monitor & controller to inter-
face with a wide range of Pem-Tech gas detectors and transmitters. The
• Fully programmble alarm relays for Audio and gas monitor is fully programmable using the color touch screen. Up to 64
visual alarms and peripherlas.
detectors (expandable to 96) can be interfaced to the monitor.
• USB Port for easy data download into an
MS-Excel File. Up to 4 Gigabytes of Flash memory for Historical Data Logs. Log files
downloaded via USB port to a flash stick into Excel file format.
• Optional Cell modem for alarm call out and text Monitor comes in standard with communication port for multiple mimic
messaging.
panels (remote data readout) and an ethernet port for LAN network.
• TCP/IP or RS-485 MODBUS RTU An optional Quad Band GPRS Cell Module is also available to transmit
Alarm Text Messages over mobile phone. An RS485 Comm Port is also
available for user PLC communication.
Model PT2000 Multichannel Monitor
SPECIFICATIONS

Detector Interface 64 Channel Capacity. Expandable to 96 chanels.


Main Data Display Screen
All Pem-Techs transmitters (4-20mA) and serial
addressable detectors. Optional wireless gateway
to interface with wirelesss detctors.

Alarm Relays Up to 32 Alarm relays, fully programmable for 3


distinct levels of alarms.
Relays can be organized into zones for designated
area alarms.
Din-Mount SPDT Form “C” type Relay contacts
6 Amps @ 250 VAC or 30 VDC
** Addtional Relay modules - optional

Power Input 120/220 VAC to 24 VDC


10Amps for 32 Channel Configuration
20 Amps (Redundant) for 64 Channels

Power Consumption Nominal 0.7A @ 24 VDC


2.2 Amps maximum with relays actiave
(does not include detector power consumption)

Display 8” Color Touch Screen

Historical Upto 4 GB for data storage


Data Storage 2 Historical logs are mainainted
* Interval Log: Maximum and average readings
of each detector recored every interval.
Log interval user programmble
(15 minutes to 1 hour)
* Event Log: Records all alarms and fault
conditions, Bypass and calibrate mode for
each detectors. Also low battery indication and
other system failure conditions

All historical data downloaded to a flash drive via


USB port on the front panel. All data in MS-Excel
file format

Peripherals & Interface * USB Port: For Data Download to flash drive Data display block for each detector
* RS-485 for Mimic / Repeater Panel
* MODBUS TCP/IP
Drill Floor Location of detector
Options • Quad Band Cell Modem for transmitting text
messages over cellular network
H2S = 00 ppm Current gas reading
• Repeater / Mimic panel
Drill Floor
Operating Temperature 32 °F to +122 °F (0 °C to +50 °C)
** Calib Mode ** Detector in Calib Mode
Approved Enclosure * Nema 4X, Fiberglass, IP 66 Wallmount
Options * Nema 4X, Stainless Steel, IP66 Wallmount
Drill Floor
** FAULT ** Sensor Fault

PemTech Worldwide
www.pem-tech.com

Sugar Land, Texas U.A.E. Saudi Arabia Singapore


12144 Dairy Ashford, Bldg 2 Dubai Insurance Bldg Al Sharq Tower, 6th Floor Blk 3026 Ubi Road
Sugar Land, Texas 77478 City Center, Dubai AL-Khobar Singapore 408719
Tel: +1-281-494-2079 United Arab Emirates Tel: +966 13 897 7577 Tel: +65 6848 9570
Fax: +1-281-494-2167 Tel: +971 4 258 5343 Fax: +966 12 881 1937 Fax: +65 6848 9356
sales@pem-tech.com info.ME@pem-tech.com info.ME@pem-tech.com sales@pemtech-asia.com

You might also like