Download as pdf or txt
Download as pdf or txt
You are on page 1of 1

Friction loss calculation

Pumped fluid Static head Layout


Water, pure 12 Suction lift installation

Flow Number of pumps Calculation model


33.3 l/s 1 Colebrook-White

Viscosity Nature of system


1.569 mm²/s Single head pump

Type Ø ? or L Qty. v k ΔH
(mm) (m/s) (mm) (m)
Ø = Diameter v = Velocity k = Pipe roughness ΔH = Head loss
Common discharge side pipe - Metal / Stainless steel
PN 40 / DN 100 (104x2,0 mm) / K factor for Wastewater acc. DWA-A110
Pipe length 100 6m 1 4.24 0.25 1.398
Elbows 100 0.3 1 4.24 0.2749
Intake, conical 100 0.2 1 4.24 0.1832
Total friction head 1.856

Friction loss head 1.856 m


Total static head 12 m
Total head 13.86 m

Project Created by Manuel Lineiro Last update 4/26/2023