Professional Documents
Culture Documents
8400 Catalogue en
8400 Catalogue en
8400 Catalogue en
We can offer you automation solutions in- Cut your process costs and increase your
cluding control, visualisation and drive ability to compete. Let us analyse your drive
technology from a single source. Our drive technology tasks and support you with
systems will improve the performance of made-to-measure solutions. We can take
your machines. From project planning to an integrated approach to projects thanks
commissioning, we have the know-how, to the scalability of our products and the
whilst our international sales and service scope of the overall portfolio. We can get
network can provide you with expert help the best from your machines and systems.
and advice at any time.
L-force Your future is our drive
In order to offer you more options and (ad- L-force means system
ded) value, we are constantly working to With L-force, everything is perfectly
improve our solution still further. matched.
4
System overview 8400 Inverter Drives
Other catalogues
Frequency inverters and accessories for the ƒ 9300 servo inverter and ECS servo sys-
L-force Inverter Drives 8400 series in the tem up to 75 kW are shown in the cata-
power range from 0.25 to 45 kW can be logue Servo Inverters
found in this catalogue. Additional compon- ƒ Controllers, industrial PCs, I/O systems
ents and system solutions can be found in and monitor panels are shown in the
the following catalogues: catalogues Controller-based Automation
ƒ smd, 8200 vector, 8200 motec and 9300 and PC based Automation.
vector frequency inverters up to 90 kW ƒ Standard motors are shown in the cata-
can be found in the inverters catalogue logue Three-phase Motors.
ƒ Servo Drives 9400 up to 400 kW can be ƒ Standard geared motors are shown in
found in the Servo Drives 9400 cata- the catalogue G-motion const.
logue.
5
Contents 8400 Inverter Drives
Product information
Product key 8
List of abbreviations 10
About this catalogue 11
The Rightsizing principle 12
Functions and features 14
Control connections 16
Standards and operating conditions 18
Inverter
Rated data 230 V 19
Rated data 400 V 22
Dimensions 28
Weights 30
Safety system (STO) 31
Memory module 31
Memory module copier 31
Accessories
Brake resistors 32
Mains chokes 34
Interference suppression 35
24 V power supply unit 37
Brake switch 37
USB diagnostic adapter 38
Connecting cables for USB diagnostic adapter 38
X400 keypad 39
Diagnosis terminal X400 39
PC system bus adapter 40
Shield connection 40
Setpoint potentiometer 41
Other accessories 41
Modules
Communication module PROFIBUS 42
Communication module EtherCAT 44
Communication module PROFINET 46
L-force Engineer
General information 48
Functions and features 49
Data access/communication 50
Selection and order data 51
Lenze world-wide
Lenze world-wide 54
Product key
Equipment
Pluggable
relay connection*
Communication
module*
optional
Safety engineering
(STO)*
optional
Memory module
L-force
˘ pluggable
diagnostics
˘ contains all
interface
drive data
for USB adapter with
PC connection or
keypad
Pluggable
control terminals*
with spring contacts CANopen on board
˘ DS301-compliant
˘ T plug
Integrated
shield connection*
for the motor cable
Integrated Pluggable
shield connection motor connection*
for control cables
List of abbreviations
We call it Rightsizing: The Inverter Drives 8400 have been Rightsized for quick start-up
designed for consistent process optimisation – throughout The inverters are supplied complete with integrated shield
all phases of the value-added chain. They reduce your outlay connections. This reduces the time required to prepare for
from selection onwards, via project planning, production and and carry out assembly work. Simply select predefined applic-
commissioning and beyond to service. ations to tailor the frequency inverter to meet the require-
ments of your application. In the simplest case scenario, all
Rightsized for a diverse range of applications you need to do is set two parameters: "Application" and
Do you want to control or regulate motors, or achieve posi- "Setpoint source".
tioning with or without feedback? Then select the inverter
that precisely meets your requirements from the Inverter Rightsized for optimum operation
Drives 8400 scaled range. What's more, that is all from a power When developing human machine interfaces we never lose
range of 0.25 kW to 45 kW. sight of the importance of the human element. Whether you
are working with a keypad or on a PC, you can rely on the
Rightsized for increased productivity support of intuitive user menus.
The functionality and drive behaviour of the 8400 series–
BaseLine, StateLine, HighLine and TopLine – develop consist- Rightsized for rapid service
ently from one to the next which makes your selection process Diagnostics and parameter setting by means of remote
simple. The diagnostics connections and tools, operation and maintenance mean that service can be provided quickly and
parameter settings are all identical across each design. The cost-effectively, wherever you are in the world. Thanks to the
strengths of the 8400 series really prove their superiority when memory module, integrated shield connections and pluggable
you use different models in your application. terminals, drives can be replaced quickly, thereby reducing
machine downtimes.
Rightsized for the future
Upgrades at a later date are no problem. If the features of a
StateLine no longer suffice, you can easily replace it with a
HighLine – without having to redesign your control cabinet.
Combined with environmentally-friendly production, compli-
ant with ISO 14001 and RoHS – this makes the series future-
proof.
8400 BaseLine, StateLine (here, with Cold Plate technology), HighLine and TopLine
8400 BaseLine - for constant motion 8400 HighLine - for positioning tasks
The BaseLine version is the entry-level model in terms of In addition to the possibilities of the 8400 StateLine, the 8400
functionality and drive behaviour. Featuring an integrated HighLine has an integrated point-to-point positioning system.
keypad and everything you would expect from a modern fre- This makes it possible to store, among other things, 15 select-
quency inverter suitable for universal use, the 8400 BaseLine able position destinations, including the associated travel
is the ideal solution for applications such as conveyor drives, profile, e.g. acceleration, in the inverter. The higher-level
pumps, fans or ventilators. control systems selects these position sets and stipulates the
sequence of events. The incremental encoder signal is evalu-
8400 StateLine - for controlled motion ated via two digital inputs, although, in many applications,
The 8400 StateLine has been designed specifically for drives feedback can be dispensed with.
with or without speed feedback and is used wherever network- The 8400 HighLine is recommended for applications such as
ing via bus systems is required. Furthermore, integrated brake rotary indexing tables, sliding doors, or positioning tasks in
handling contributes to a significant reduction in wear on warehouse systems.
service brakes. Even very frequent mains switching is unable
to ruffle the feathers of the StateLine, as the input circuit is 8400 TopLine - for servo applications
protected against overload. 8400 TopLine – the inverter with servo qualities within the
The 8400 StateLine takes over applications whose complex 8400 series. Equipped with everything needed for a high dy-
requirements go beyond the capabilities of the BaseLine. It is namic response and precision in complex applications. In ad-
also ideal for applications such as palletizers, extruders, filling dition to a resolver input, for example, there is also a multiple
systems or travelling/variable speed drives. encoder input that is a very useful addition to the spectrum
of usable feedback systems. In addition, not only asynchronous
motors but also the more dynamic synchronous motors are
supported.
Profit from the precisely tailored, cost-optimised Lenze drive
packages consisting of prepared system cables, motors and
gearboxes, feedback units, brakes and fans, as well, of course,
the 8400 TopLine.
The 8400 TopLine is particularly recommended for pick -and-
place applications.
Mode
8400 BaseLine 8400 StateLine
Control types, motor control
V/f control without encoder V/f control without encoder
(linear or square-law) (linear or square-law)
Sensorless vector control Sensorless vector control
(torque/speed) (torque/speed)
V/f control with encoder
Basic functions
Application-oriented commissioning Application-oriented commissioning
(predefined application) (predefined application)
Freely assignable user menu Freely assignable user menu
Data logger Data logger
DC brake function DC brake function
Flying restart circuit Flying restart circuit
S-shaped ramps for smooth acceleration S-shaped ramps for smooth acceleration
Max. output frequency 300 Hz Max. output frequency 1000Hz
PID controller PID controller
3 fixed frequencies 15 fixed frequencies
180 % overload current (3 s) 200% overload current (3 s)
"VFC eco" energy-saving function 1)
Parameter change-over
Masking frequencies
Switch-off positioning (without encoder)
Braking operation without brake resistor
Brake management for brake control with
low rate of wear
Inversion of motor phase sequence
Logical functions, comparator, counter,
arithmetic function
Function block interconnection for input
and output signals
Mode
8400 HighLine 8400 TopLine
Control types, motor control
V/f control without encoder V/f control without encoder
(linear or square-law) (linear or square-law)
Sensorless vector control Sensorless vector control
(torque/speed) (torque/speed)
V/f control with encoder V/f control with encoder
Servo control (asynchronous motor) Servo control (asynchronous motor)
Servo control (synchronous motor)
Basic functions
Application-oriented commissioning Application-oriented commissioning
(predefined application) (predefined application)
Freely assignable user menu Freely assignable user menu
Data logger Data logger
DC brake function DC brake function
Flying restart circuit Flying restart circuit
S-shaped ramps for smooth acceleration S-shaped ramps for smooth acceleration
Max. output frequency 1000Hz Max. output frequency 1000Hz
PID controller PID controller
15 fixed frequencies 15 fixed frequencies
200% overload current (3 s) 200% overload current (3 s)
"VFC eco" energy-saving function "VFC eco" energy-saving function
Parameter change-over Parameter change-over
Masking frequencies Masking frequencies
Switch-off positioning (without encoder) Switch-off positioning (without encoder)
Braking operation without brake resistor Braking operation without brake resistor
Brake management for brake control with Brake management for brake control with
low rate of wear low rate of wear
Inversion of motor phase sequence Inversion of motor phase sequence
Logical functions, comparator, counter, Logical functions, comparator, counter,
arithmetic function arithmetic function
Function block interconnection for input Function block interconnection for input
and output signals and output signals
Free function block interconnection Free function block interconnection
Point-to-point positioning Point-to-point positioning
Monitoring and protective measures
Short circuit Short circuit
Earth fault Earth fault
Overvoltage Overvoltage
Motor stalling Motor stalling
I² x t monitoring I² x t monitoring
Motor phase failure Motor phase failure
Mains phase failure Mains phase failure
Protection against restart for cyclic mains Protection against restart for cyclic mains
switching switching
Motor overtemperature Motor overtemperature
(input for PTC or thermal contact) (input for PTC or thermal contact, KTY
evaluation)
Diagnostics
Diagnostic interface Integrated Integrated
For USB diagnostic adapter with PC con- For USB diagnostic adapter with PC con-
nection or X400 keypad nection or X400 keypad
Status display 4 LEDs 6 LEDs
Braking operation
Brake chopper Integrated Integrated
Brake resistor External External
Control connections
Mode
8400 BaseLine 8400 StateLine
Analog inputs
Number 1 1
Switchable: voltage or current input Optional: voltage or current input
Resolution 10 bits 10 bits
Value range 0 ... 10V, 0/4 ... 20mA 0 ... +/- 10V, 0/4 ... 20 mA
Analog outputs
Number 1
Resolution 10 bits
Value range 0 ... 10V
Digital inputs
Number 5 5
Switching level PLC (IEC 61131-2) PLC (IEC 61131-2)
Max. input current 11mA 11mA
Function
Digital outputs
Number 1 1
Switching level PLC (IEC 61131-2) PLC (IEC 61131-2)
Max. output current 50mA 50mA
Relay
Number 1 1
Contact NO contact Changeover contact
AC connection 250V, 3A 250V, 3A
DC connection 24V, 2A ... 240V, 0.16A 24V, 2A ... 240V, 0.16A
External DC supply 1)
Rated voltage 24 V
Interfaces
CANopen Integrated (BaseLine C) Integrated
Functional insulation Functional insulation
Max. baud rate 500 kbps Max. baud rate 500 kbps
Extensions Optional
Communication module
Safety engineering Optional
"Safe Torque Off (STO)"
Drive interface
Encoder input Via 2 digital inputs,
HTL, 2-track
10 kHz
Can also be used as a frequency input
Resolver input
1) For mains-independent control electronics supply
Circuit diagrams
DS_SP_8400_0001
Available for download at www.lenze.de/dsc
Control connections
Mode
8400 HighLine 8400 TopLine
Analog inputs
Number 2 2
Optional: voltage or current input Optional: voltage or current input
Resolution 10 bits 10 bits + sign
Value range 0 ... +/- 10V, 0/4 ... 20 mA 0 ... +/- 10V, 0/4 ... 20 mA
Analog outputs
Number 2 2
Optional: voltage or current output Optional: voltage or current output
Resolution 10 bits 10 bits
Value range 0 ... 10V, 0/4 ... 20mA 0 ... 10V, 0/4 ... 20mA
Digital inputs
Number 8 8
Switching level PLC (IEC 61131-2) PLC (IEC 61131-2)
Max. input current 11mA 11mA
Function 2 inputs, can optionally be used as a frequency 2 inputs, can optionally be used as a frequency
input (10 kHz, 2-track) input (10 kHz, 2-track)
Digital outputs
Number 4 4
Switching level PLC (IEC 61131-2) PLC (IEC 61131-2)
Max. output current 1 x 2.5A, (basic insulation, with spark suppress- 1 x 2.5A, (basic insulation, with spark suppress-
or, e.g. for 24 V service brake) or, e.g. for 24 V service brake)
3 x 50mA 3 x 50mA
Relay
Number 1 1
Contact Changeover contact Changeover contact
AC connection 250V, 3A 250V, 3A
DC connection 24V, 2A ... 240V, 0.16A 24V, 2A ... 240V, 0.16A
External DC supply
Rated voltage 24 V 24 V
Interfaces
CANopen Integrated Integrated
Functional insulation Functional insulation
Max. baud rate 1000 kbps Max. baud rate 1000 kbps
Extensions Optional Optional
Communication module Communication module
Safety engineering Optional Optional
"Safe Torque Off (STO)" "Safe Torque Off (STO)"
Drive interface
Encoder input Via 2 digital inputs, Via 2 digital inputs,
HTL, 2-track HTL, 2-track
100 kHz, 100 kHz,
Can also be used as a frequency input Can also be used as a frequency input
Sub-D, 15-pin
Multiple encoder input for: TTL incremental
encoder, SSI absolute value encoder (single-
turn/multi-turn)
Resolver input Sub-D, 9-pin
1) For mains-independent control electronics supply
Circuit diagrams
DS_SP_8400_0001
Available for download at www.lenze.de/dsc
Mode
Product 8400 BaseLine 8400 StateLine 8400 HighLine 8400 TopLine
Conformity
Type CE: Low-Voltage Directive
2006/95/EC
Approval
UL 508C 1) Power Conver- Power Conversion Equipment (file no. E132659)
sion Equip-
ment (File-No.
E170350)
Certification
GOST-R
Enclosure
EN 60529 2) IP20
NEMA 250 Type 1
Climatic conditions
Storage (EN 60721-3-1) 1K3 (temperature: -25 °C ... +60 °C)
Transport (EN 60721-3-2) 2K3 (temperature: -25 °C ... +70 °C)
Operation (EN 60721-3-3) 3K3 (temperature: -10°C ... +55°C)
Power reduction above 45 °C 2.5% / K
Site altitude
Amsl Hmax [m] 4000
power reduction above 1000 m [%/1000 m] 5.00
Vibration resistance
Transport (EN 60721-3-2) 2M2
Operation (EN 61800-5-1) 10 Hz 싨 f 싨 57 Hz: ± 0.075 mm amplitude,
57 Hz 싨 f 싨 150 Hz: 1.0 g
Operation (Germanischer Lloyd) 5 Hz 싨 f 싨13.2 Hz ± 1 mm amplitude,
13.2 Hz 싨 f 싨 100 Hz: 0.7 g
1) In preparation for 30, 37 and 45 kW
2) Mounted and ready-to-use
Mode
Product 8400 BaseLine 8400 StateLine 8400 HighLine 8400 TopLine
Supply form
Systems with Systems with earthed star point (TN and TT sys-
earthed star tems)
point (TN and Systems with high-resistance or isolated star
TT systems) point (IT systems)
Noise emission
EN 61800-3 Integrated RFI suppression: cable-guided, category C2 up to 25 m
shielded motor cable 3)
Insulation resistance
EN 61800-5-1 Overvoltage category III
Above 2000 m amsl overvoltage category II
Degree of pollution
EN 61800-5-1 2
Protective insulation of control circuits
EN 61800-5-1 Safe mains isolation: double/reinforced insulation
3) Depending on the drive, shielded motor cable up to 50 m is possible
Rated data
ƒ The data is valid for operation at 230 V AC. Rated data and dimension sheets
ƒ Unless otherwise specified, the data refers to the default DS_GD_8400_0001
setting. Available for download at www.lenze.de/dsc
2) Overload: 150% * IN, out for 60 s, 200% (BaseLine 180%) * IN, out for 3 s
3) Technically possible cable lengths, irrespective of EMC requirements
Dimensions
Dimensions - BaseLine
Dimensions
Height h [mm] 165 165
Width b [mm] 70 70
Depth 4) t [mm] 144 144
4) Depth of 8400 BaseLine with CANopen (BaseLine C), additional 8 mm
Dimensions - built-in unit StateLine, HighLine
Dimensions
Height h [mm] 165 165
Width b [mm] 70 70
Depth 5) t [mm] 199 199
5) 8400 StateLine, HighLine and TopLine depth increases by 20 mm with safety
engineering
Rated data
ƒ The data is valid for operation at 230 V AC. Rated data and dimension sheets
ƒ Unless otherwise specified, the data refers to the default DS_GD_8400_0001
setting. Available for download at www.lenze.de/dsc
2) Overload: 150% * IN, out for 60 s, 200% (BaseLine 180%) * IN, out for 3 s
3) Technically possible cable lengths, irrespective of EMC requirements
Dimensions
Dimensions - BaseLine
Dimensions
Height h [mm] 165 165
Width b [mm] 70 70
Depth 4) t [mm] 162 162
4) Depth of 8400 BaseLine with CANopen (BaseLine C), additional 8 mm
Dimensions - built-in unit StateLine, HighLine
Dimensions
Height h [mm] 215 215
Width b [mm] 70 70
Depth 5) t [mm] 199 199
5) 8400 StateLine, HighLine and TopLine depth increases by 20 mm with safety
engineering
Dimensions, TopLine built-in unit
Dimensions
Height h [mm] 215 215
Width b [mm] 70 70
Depth 5) t [mm] 214 214
Rated data
ƒ The data is valid for operation at 230 V AC. Rated data and dimension sheets
ƒ Unless otherwise specified, the data refers to the default DS_GD_8400_0001
setting. Available for download at www.lenze.de/dsc
2) Overload: 150% * IN, out for 60 s, 200% (BaseLine 180%) * IN, out for 3 s
3) Technically possible cable lengths, irrespective of EMC requirements
Dimensions
Dimensions - BaseLine
Dimensions
Height h [mm] 165 215 215
Width b [mm] 70 70 70
Depth 4) t [mm] 162 162 162
4) Depth of 8400 BaseLine with CANopen (BaseLine C), additional 8 mm
Dimensions - built-in unit StateLine, HighLine
Dimensions
Height h [mm] 270 270 270
Width b [mm] 70 70 70
Depth 5) t [mm] 199 199 199
5) 8400 StateLine, HighLine and TopLine depth increases by 20 mm with safety
engineering
Dimensions, TopLine built-in unit
Dimensions
Height h [mm] 270 270 270
Width b [mm] 70 70 70
Depth 5) t [mm] 214 214 214
Rated data
ƒ The data is valid for operation at 400 V AC. Rated data and dimension sheets
ƒ Unless otherwise specified, the data refers to the default DS_GD_8400_0002
setting. Available for download at www.lenze.de/dsc
2) Overload: 150% * IN, out for 60 s, 200% (BaseLine 180%) * IN, out for 3 s
3) 8400 BaseLine only with connector (order designation: EWS0074/M)
4) Technically possible cable lengths, irrespective of EMC requirements
Dimensions
Dimensions - BaseLine
Dimensions
Height h [mm] 165 165 165
Width b [mm] 70 70 70
Depth 5) t [mm] 165 165 165
5) Depth of 8400 BaseLine with CANopen (BaseLine C), additional 8 mm
Dimensions - built-in unit StateLine, HighLine
Dimensions
Height h [mm] 215 215 215
Width b [mm] 70 70 70
Depth 6) t [mm] 199 199 199
6) 8400 StateLine, HighLine and TopLine depth increases by 20 mm with safety
engineering
Dimensions, TopLine built-in unit
Dimensions
Height h [mm] 215 215 215
Width b [mm] 70 70 70
Depth 6) t [mm] 214 214 214
Rated data
ƒ The data is valid for operation at 400 V AC. Rated data and dimension sheets
ƒ Unless otherwise specified, the data refers to the default DS_GD_8400_0002
setting. Available for download at www.lenze.de/dsc
2) Overload: 150% * IN, out for 60 s, 200% (BaseLine 180%) * IN, out for 3 s
3) 8400 BaseLine only with connector (order designation: EWS0074/M)
4) Technically possible cable lengths, irrespective of EMC requirements
Dimensions
Dimensions - BaseLine
Dimensions
Height h [mm] 165 165 215 215
Width b [mm] 70 70 70 70
Depth 5) t [mm] 162 162 162 162
5) Depth of 8400 BaseLine with CANopen (BaseLine C), additional 8 mm
Dimensions - built-in unit StateLine, HighLine
Dimensions
Height h [mm] 270 270 270 270
Width b [mm] 70 70 70 70
Depth 6) t [mm] 199 199 199 199
6) 8400 StateLine, HighLine and TopLine depth increases by 20 mm with safety
engineering
Dimensions, TopLine built-in unit
Dimensions
Height h [mm] 270 270 270 270
Width b [mm] 70 70 70 70
Depth 6) t [mm] 214 214 214 214
Rated data
ƒ The data is valid for operation at 400 V AC. Rated data and dimension sheets
ƒ Unless otherwise specified, the data refers to the default DS_GD_8400_0002
setting. Available for download at www.lenze.de/dsc
2) Overload: 150% * IN, out for 60 s, 200% (BaseLine 180%) * IN, out for 3 s
3) Technically possible cable lengths, irrespective of EMC requirements
Dimensions
Rated data
ƒ The data is valid for operation at 400 V AC. Rated data and dimension sheets
ƒ Unless otherwise specified, the data refers to the default DS_GD_8400_0002
setting. Available for download at www.lenze.de/dsc
Dimensions
Rated data
ƒ The data is valid for operation at 400 V AC. Rated data and dimension sheets
ƒ Unless otherwise specified, the data refers to the default DS_GD_8400_0002
setting. Available for download at www.lenze.de/dsc
Dimensions
Rated data
ƒ The data is valid for operation at 400 V AC. Rated data and dimension sheets
ƒ Unless otherwise specified, the data refers to the default DS_GD_8400_0002
setting. Available for download at www.lenze.de/dsc
Dimensions
Dimensions
Dimensions - Cold Plate technology StateLine, HighLine Dimensions, TopLine cold plate technology
4-pole asynchron-
Inverter Inverter
Height, including
Height, including
Width, including
Width, including
ous motor
ous motor
fastening
fastening
fastening
fastening
Depth
Depth
P h b t P h b t
[kW] [mm] [mm] [mm] [kW] [mm] [mm] [mm]
E84AV၂၂၂2512၂၂0 0.25 E84AV၂၂၂5512၂၂0 0.55
186 185 236 102
E84AV၂၂၂3712၂၂0 0.37 E84AV၂၂၂7512၂၂0 0.75
102
E84AV၂၂၂5512၂၂0 0.55 E84AV၂၂၂1122၂၂0 1.10
236
E84AV၂၂၂7512၂၂0 0.75 E84AV၂၂၂1522၂၂0 1.50 295 173
E84AV၂၂၂1122၂၂0 1.10 E84AV၂၂၂2222၂၂0 2.20
E84AV၂၂၂1522၂၂0 1.50 295 173 E84AV၂၂၂3714၂၂0 0.37
178
E84AV၂၂၂2222၂၂0 2.20 E84AV၂၂၂5514၂၂0 0.55 236 102
E84AV၂၂၂3714၂၂0 0.37 E84AV၂၂၂7514၂၂0 0.75
163
E84AV၂၂၂5514၂၂0 0.55 236 102 E84AV၂၂၂1124၂၂0 1.10
E84AV၂၂၂7514၂၂0 0.75 E84AV၂၂၂1524၂၂0 1.50
295 137
E84AV၂၂၂1124၂၂0 1.10 E84AV၂၂၂2224၂၂0 2.20
E84AV၂၂၂1524၂၂0 1.50 E84AV၂၂၂3024၂၂S 3.00
295 137
E84AV၂၂၂2224၂၂0 2.20 E84AV၂၂၂4024၂၂0 4.00
321
E84AV၂၂၂3024၂၂S 3.00 E84AV၂၂၂5524၂၂0 5.50
E84AV၂၂၂4024၂၂0 4.00 E84AV၂၂၂7524၂၂0 7.50 174 156
321
E84AV၂၂၂5524၂၂0 5.50 E84AV၂၂၂1134၂၂0 11.0 360
E84AV၂၂၂7524၂၂0 7.50 174 141 E84AV၂၂၂1534၂၂0 15.0
E84AV၂၂၂1134၂၂0 11.0 360 E84AV၂၂၂1834၂၂0 18.5
390 231 179
E84AV၂၂၂1534၂၂0 15.0 E84AV၂၂၂2234၂၂0 22.0
E84AV၂၂၂1834၂၂0 18.5
390 231 164
E84AV၂၂၂2234၂၂0 22.0
Dimensions
Dimensions of push-through technique for StateLine, HighLine Dimensions, TopLine push-through technique
4-pole asynchron-
Inverter Inverter
Height, including
Width, including
Width, including
cabinet side)
cabinet side)
ous motor
ous motor
fastening
fastening
fastening
fastening
P h b t P h b t
[kW] [mm] [mm] [mm] [kW] [mm] [mm] [mm]
E84AV၂၂၂2512၂၂0 0.25 E84AV၂၂၂5512၂၂0 0.55
186 185 236 102
E84AV၂၂၂3712၂၂0 0.37 E84AV၂၂၂7512၂၂0 0.75
102
E84AV၂၂၂5512၂၂0 0.55 E84AV၂၂၂1122၂၂0 1.10
236
E84AV၂၂၂7512၂၂0 0.75 E84AV၂၂၂1522၂၂0 1.50 295 137
E84AV၂၂၂1122၂၂0 1.10 E84AV၂၂၂2222၂၂0 2.20
E84AV၂၂၂1522၂၂0 1.50 295 137 E84AV၂၂၂3714၂၂0 0.37 178
E84AV၂၂၂2222၂၂0 2.20 E84AV၂၂၂5514၂၂0 0.55 236 102
E84AV၂၂၂3714၂၂0 0.37 163 E84AV၂၂၂7514၂၂0 0.75
E84AV၂၂၂5514၂၂0 0.55 236 102 E84AV၂၂၂1124၂၂0 1.10
E84AV၂၂၂7514၂၂0 0.75 E84AV၂၂၂1524၂၂0 1.50 295 137
E84AV၂၂၂1124၂၂0 1.10 E84AV၂၂၂2224၂၂0 2.20
E84AV၂၂၂1524၂၂0 1.50 295 137 E84AV၂၂၂3024၂၂0 3.00
E84AV၂၂၂2224၂၂0 2.20 E84AV၂၂၂4024၂၂0 4.00 321
E84AV၂၂၂3024၂၂0 3.00 E84AV၂၂၂5524၂၂0 5.50
174 156
E84AV၂၂၂4024၂၂0 4.00 321 E84AV၂၂၂7524၂၂0 7.50
E84AV၂၂၂5524၂၂0 5.50 E84AV၂၂၂1134၂၂0 11.0 360
174 141
E84AV၂၂၂7524၂၂0 7.50 E84AV၂၂၂1534၂၂0 15.0
E84AV၂၂၂1134၂၂0 11.0 360
E84AV၂၂၂1534၂၂0 15.0
Weights
The tables below show the weights of frequency inverters Different product versions result in the following additional
without a communication module for built-in units. masses:
push-through technique version: 0.100 kg.
safety engineering version: 0.100 kg
Mode Product key Mass
m
[kg]
E84AV၂၂၂2512၂၂0
E84AV၂၂၂3712၂၂0
1.2
E84AV၂၂၂5512၂၂0
E84AV၂၂၂7512၂၂0
E84AV၂၂၂1122၂၂0 1.4
E84AV၂၂၂1522၂၂0
1.9
E84AV၂၂၂2222၂၂0
8400 BaseLine
E84AV၂၂၂3714၂၂0
E84AV၂၂၂5514၂၂0 1.2
E84AV၂၂၂7514၂၂0
E84AV၂၂၂1124၂၂0
1.4
E84AV၂၂၂1524၂၂0
E84AV၂၂၂2224၂၂0 1.9
E84AVB၂၂3024၂၂0 2.1
Memory module
All drive settings for the 8400 are stored on the memory
module, which is a pluggable memory chip. You can copy the
settings to other memory modules. The advantage for you:
much faster commissioning, particularly in series production.
Furthermore, the memory module ensures that drives can be
replaced quickly and without errors being made.
Brake resistors
Typical Mains Product key Rated res- Rated Thermal Dimensions Mass
motor voltage istance power capacity
power
4-pole Inverter Brake resistor
asynchron-
ous motor
P UAC RN PN Cth hxbxt m
[kW] [V] [˖] [W] [KWs] [mm] [kg]
0.25 E84AV၂၂၂2512၂၂0
ERBM180R050W 180.0 50.0 8 175 x 21 x 40 0.3
0.37 E84AV၂၂၂3712၂၂0
0.55 E84AV၂၂၂5512၂၂0
1 AC 180 ERBM100R100W 100.0 100.0 15 240 x 80 x 95 0.5
0.75 E84AV၂၂၂7512၂၂0
... 264
1.10 E84AV၂၂၂1122၂၂0
ERBP033R200W 200.0 30 240 x 41 x 122 1.0
1.50 E84AV၂၂၂1522၂၂0 33.0
2.20 E84AV၂၂၂2222၂၂0 ERBP033R300W 300.0 45 320 x 41 x 122 1.4
0.37 E84AV၂၂၂3714၂၂0
0.55 E84AV၂၂၂5514၂၂0 ERBM390R100W 390.0 100.0 15 235 x 21 x 40 0.4
0.75 3 AC 320 E84AV၂၂၂7514၂၂0
1.10 ... 550 E84AV၂၂၂1124၂၂0
ERBP180R200W 200.0 30 240 x 41 x 122 1.0
1.50 E84AV၂၂၂1524၂၂0 180.0
2.20 E84AV၂၂၂2224၂၂0 ERBP180R300W 300.0 45 320 x 41 x 122 1.4
Data sheet on ERBM brake resistors Data sheet on ERBP brake resistors
DS_ZB_ERBM_0001 DS_ZB_ERBP_0001
Available for download at www.lenze.de/dsc Available for download at lenze.de/dsc
Data sheet on ERBP brake resistors Data sheet on ERBS brake resistors
DS_ZB_ERBP_0001 DS_ZB_ERBS_0001
Available for download at lenze.de/dsc Available for download at www.lenze.com/dsc
Brake resistors
Mains chokes
Interference suppression
Typical motor Mains voltage Product key Rated current Dimensions Mass
power
4-pole asyn- Inverter 1) RFI filter
chronous mo-
tor
P UAC IN hxbxt m
[kW] [V] [A] [mm] [kg]
E84AZESR3712LL
0.25 E84AV၂၂၂2512၂၂0 E84AZESR3712SD
E84AZESR3712LD
5.00 212 x 70 x 60 0.8
E84AZESR3712LL
0.37 E84AV၂၂၂3712၂၂0 E84AZESR3712SD
E84AZESR3712LD
1 AC 180 ... 264
E84AZESR5512LL 6.00
0.55 E84AV၂၂၂5512၂၂0 E84AZESR7512SD
E84AZESR7512LD
262 x 70 x 60 1.0
E84AZESR7512LL 9.00
0.75 E84AV၂၂၂7512၂၂0 E84AZESR7512SD
E84AZESR7512LD
1) 8400 StateLine, HighLine and TopLine
Interference suppression
Typical motor Mains voltage Product key Rated current Dimensions Mass
power
4-pole asyn- Inverter 1) RFI filter
chronous mo-
tor
P UAC IN hxbxt m
[kW] [V] [A] [mm] [kg]
E84AZESR2222LL 1.4
1.10 E84AV၂၂၂1122၂၂0 E84AZESR2222SD 1.7
E84AZESR2222LD 1.5
E84AZESR2222LL 1.4
1.50 1 AC 180 ... 264 E84AV၂၂၂1522၂၂0 E84AZESR2222SD 22.0 317 x 70 x 60 1.7
E84AZESR2222LD 1.5
E84AZESR2222LL 1.4
2.20 E84AV၂၂၂2222၂၂0 E84AZESR2222SD 1.7
E84AZESR2222LD 1.5
E84AZESR7514SD
0.37 E84AV၂၂၂3714၂၂0
E84AZESR7514LD
E84AZESR7514SD
0.55 E84AV၂၂၂5514၂၂0 3.30 262 x 70 x 60 1.1
E84AZESR7514LD
E84AZESR7514SD
0.75 E84AV၂၂၂7514၂၂0
E84AZESR7514LD
E84AZESR2224SD 1.5
1.10 E84AV၂၂၂1124၂၂0
E84AZESR2224LD 1.4
E84AZESR2224SD 1.5
1.50 E84AV၂၂၂1524၂၂0 7.30 317 x 70 x 60
E84AZESR2224LD 1.4
3 AC 320 ... 550
E84AZESR2224SD 1.5
2.20 E84AV၂၂၂2224၂၂0
E84AZESR2224LD 1.4
E84AZESR5524SD 3.1
4.00 E84AV၂၂၂4024၂၂0
E84AZESR5524LD 2.2
18.0 306 x 140 x 60
E84AZESR5524SD 3.1
5.50 E84AV၂၂၂5524၂၂0
E84AZESR5524LD 2.2
7.50 E84AV၂၂၂7524၂၂0
11.0 E84AV၂၂၂1134၂၂0 E84AZESR1534LD 29.0 361 x 140 x 60 3.3
15.0 E84AV၂၂၂1534၂၂0
18.5 E84AV၂၂၂1834၂၂0 E84AZESR1834LD 50.4 365 x 205 x 90 7.5
Typical motor Mains voltage Product key Rated current Dimensions Mass
power
4-pole asyn- Inverter 1) Mains filter
chronous mo-
tor
P UAC IN hxbxt m
[kW] [V] [A] [mm] [kg]
22.0 3 AC 320 ... 550 E84AV၂၂၂2234၂၂0 E84AZESM2234LD 42.0 365 x 205 x 90 14.0
1) 8400 StateLine, HighLine and TopLine
Rated data
Product key
EZV1200- EZV2400- EZV4800- EZV1200- EZV2400- EZV4800-001
000 000 000 001 001
Rated voltage
AC UN, AC [V] 230 400
Rated mains current
IN, AC [A] 0.84 1.20 2.30 0.34 0.57 1.00
Output voltage
Uout [V] DC 22.5 ...28.5
Rated current
IN [A] 5.00 10.0 20.0 5.00 10.0 20.0
Dimensions
Height h [mm] 130
Width b [mm] 55 85 157 73 85 160
Depth t [mm] 125
Mass
m [kg] 0.8 1.2 2.5 1.0 1.1 1.9
Brake switch
Brake switch
Data sheet on E82ZWBRE brake switch Data sheet on E82ZWBRB brake switch
DS_Brake_8400_0001 DS_Brake_8400_0002
Available for download at www.lenze.de/dsc Available for download at www.lenze.de/dsc
X400 keypad
X400 keypad
Advantage:
ƒ Operation, parameterisation and diagnostics in parallel EMF2173IBV003 adapter
to the keypad
ƒ In networked systems, multiple inverters can be addressed
in parallel from a single station (remote parameterisation).
Shield connection
Setpoint potentiometer
Other accessories
Product key
E84AYCPMV/S
Mode
Communication module PROFIBUS
Enclosure
EN 60529 IP20
Climatic conditions
Storage (EN 60721-3-1) 1K3 (temperature: -25 °C ... +60 °C)
Transport (EN 60721-3-2) 2K3 (temperature: -25 °C ... +70 °C)
Operation (EN 60721-3-3) 3K3 (temperature: -10°C … +55°C)
Insulation voltage to reference
earth/PE
EN 61800-5-1 UAC [V] 50.0
Product key
E84AYCPMV/S
Communication
Medium RS 485
Communication profile PROFIBUS-DP-V0
PROFIBUS-DP-V1
Device profile PROFIDrive, version 3
Baud rate
[kBit / s] 9.6 ... 12 000 (automatic detection)
Node
Slave
Network topology
with repeater:
Line or tree
without repeater:
Line
Process data words (PCD)
16 Bit 1 ... 16
DP user data length
Optional parameter channel (4 words) + process data words
Number of bus nodes
31 slaves + 1 master per bus segment
With repeaters: 125
Max. cable length
per bus segment lmax [m] 1200 (depending on the baud rate and the cable type used)
Product key
E84AYCETV/S
Mode
Communication module EtherCAT
Enclosure
EN 60529 IP20
Climatic conditions
Storage (EN 60721-3-1) 1K3 (temperature: -25 °C ... +60 °C)
Transport (EN 60721-3-2) 2K3 (temperature: -25 °C ... +70 °C)
Operation (EN 60721-3-3) 3K3 (temperature: -10°C … +55°C)
Insulation voltage to reference
earth/PE
EN 61800-5-1 UAC [V] 50.0
Product key
E84AYCETV/S
Communication
Medium CAT5e S/FTP according to ISO/ICE11801 (2002)
Communication profile CoE (CANopen over EtherCAT)
Baud rate
[MBit / s] 100
Node
Slave
Network topology
Line
Number of logical process data channels
1
Process data words (PCD)
16 Bit 1 ... 16
Number of bus nodes
max. 65535
Max. cable length
between two nodes lmax [m] 100
Product key
E84AYCERV/S
Mode
Communication module PROFINET
Enclosure
EN 60529 IP20
Climatic conditions
Storage (EN 60721-3-1) 1K3 (temperature: -25 °C ... +60 °C)
Transport (EN 60721-3-2) 2K3 (temperature: -25 °C ... +70 °C)
Operation (EN 60721-3-3) 3K3 (temperature: -10°C … +55°C)
Insulation voltage to reference
earth/PE
EN 61800-5-1 UAC [V] 50.0
Product key
E84AYCERV/S
Communication
Medium CAT5e S/FTP according to ISO/ICE11801 (2002)
Communication profile PROFINET RT Conf. Class B
Baud rate
[MBit / s] 100
Node
Slave (Device)
Network topology
Line
Number of logical process data channels
1
Process data words (PCD)
16 Bit 1 ... 16
Max. cable length
between two nodes lmax [m] 100
General information
The L-force Engineer is the engineering tool for the configur- The following options are available:
ation, commissioning and diagnostics of all L-force products. ƒ Engineer StateLevel
With its intuitive user interface and transparent dialog boxes, Featuring all the necessary diagnostic functions, this
the L-force Engineer has been tailored to meet the needs of product is ideal for service engineers and commissioners.
the user. Smaller projects involving up to five target systems can
be implemented using this free version of the software.
ƒ Engineer HighLevel
The main navigation structure sorts essential functions into Engineer HighLevel is the full version of the software.
various transparent views. Graphical interfaces simplify the Single user, multiple user, corporate or buyout licences
configuration and parameterisation processes for the devices. are available.
Multi-device engineering comes naturally with the L-force In addition to the functional scope supported by the En-
Engineer StateLevel and HighLevel. gineer StateLevel, this version includes functions for large-
scale projects. You can set up networks, interconnect
communication and use the function block editor, to name
but a few of the available features. The Engineer project
even supports machine documentation. In short, you have
access to a central source where you can find everything
you need, whenever you need it – in next to no time.
The following table describes functions and features of L-force Since not all functions can be accessed by every drive, the
Engineer: engineering software appears differently, depending on the
selected drive.
Mode
L-force Engineer StateLevel, L-force Engineer HighLevel
freeware
Drives and components
8400 Inverter Drives 8400 Inverter Drives
Servo Drives 9400 Servo Drives 9400
I/O system 1000, I/O system IP20 I/O system 1000, I/O system IP20
Lenze motors Lenze motors
User motors User motors
Project creation
Limitation to 5 target systems Unlimited
Project documentation
Stored in project
Parameter setting
Graphics-based Graphics-based
Parameter list Parameter list
Networks and communication
CAN network configuration
Network configuration for ETHERNET
Powerlink
Communication interconnection
Port editor (communication interface)
Creation of machine application
Configuration
Function block editor
Diagnostics
Status display Terminal display/diagnostics overview Terminal display/diagnostics overview
Monitor window Monitor window
Logbook of all error messages Logbook of all error messages
Online values in graphics-based paramet- Online values in graphics-based paramet-
erisation erisation
Online/offline comparison Online values in function block editor
Oscilloscope: 2-channel Network diagnostics
Online/offline comparison
Oscilloscope: 8-channel
Data access/communication
Communication
CAN USB connection via USB system bus adapter EMF2177IB
Parallel interface with system bus adapter EMF2173IB
L-force diagnostic interface USB connection with diagnostic adapter E94AZCUS
System requirements
Overview of licences
54 †
Lenze world-wide
† 55
13350871
Lenze Drives GmbH * Breslauer Strasse 3 * D-32699 Extertal, Germany * Subject to technical alterations * Printed in Germany 12.2010 Version 1.0 en