Professional Documents
Culture Documents
Arfx7 SM GB
Arfx7 SM GB
CODE: 00ZARFX7EUA1E
DIGITAL MULTIFUNCTIONAL
SYSTEM OPTION
FACSIMILE EXPANSION KIT
(For U.K. / Germany / France)
MODEL AR-FX7
EXPANSION MEMORY
8MB: AR-MM9
CONTENTS
Parts marked with “ ” are important for maintaining the safety of the set. Be sure to replace these parts with
specified ones for maintaining the safety and performance of the set.
RSPF (AR-RP7)
Job separator
(AR-TR3)
AR-M236/M276
Facsimile expansion Kit
(AR-FX7)
8MB
AR-MM9
Finisher Expansion memory
(AR-FN5N)
AR-FX7 OUTLINE 1 - 1
[2] SPECIFICATIONS (3) Print resolution
600dpi (with resolution correction)
1. Communication system
4. Print system
(1) Electronic transmission system
Transmission time Less than 3 sec (Super G3/33600bps) (1) Recording size
Approx. 6 sec (G3 ECM/14400bps) Max. record width 293mm (11.5")
Compression system MH, MR, MMR, JBIG Recording paper size YES (All sizes except paper from multi
Modem speed 33600bps → 2400bps auto fall back detection bypass tray. → Recognition of the set size.
Mutual Super G3/G3 The tray has no function to detect the actual
communication paper size.)
Employed line Public Switched Telephone Network Recording paper size AB series A3/B4/A4/A4R/B5/B5R/A5/
(PSTN), Private Branch Exchange (PBX) 8.5 x 11/8.5 x 11R
Inch series 11 x 17/8.5 x 14/8.5 x 11/
R-key operation when YES (Germany only)
setting PBX 8.5 x 11R/5.5 x 8.5/A4/A4R
Number of employed One line (2) Recording paper
lines Recording paper YES
ECM YES empty detection
Paper feed All installed trays except for multi-bypass
2. Scanning system tray.
Reception paper full YES
(1) Document size detection
Max. document 297mm (11.7")
width 5. Transmission function system
Unscanable area Lead edge 5mm or less, rear edge 5mm or less
left & right edges 6mm or less (1) Simplified dialing function
Auto OC AB series A3/B4/A4/A4R/A5 Rapid key dialing/ 500 numbers (Total volume of rapid key and
detection Inch series 11 x 17/8.5 x 14/8.5 x 11/8.5 x Group dialing group dialing)
size 11R/5.5 x 8.5 registration per
RSPF AB series A3/B4/A4/A4R/A5/A5R Chain dialing YES
Inch series 11 x 17/8.5 x 14/8.5 x 11/ Redialing The preceding number in single address
8.5 x 11R/5.5 x 8.5/5.5 x 8.5R transmission is registered. (except time
Document size AB series A3/B4/A4/A4R/B5/B5R/A5/A5R specification)
specified Not cleared even by clear all key
Inch series 8.5 x 11/8.5 x 11R
Mode recall NO
Duplex document YES
specified (2) F-code communication
Long document Max. 1000mm Sub address YES (Max. 20 digits)
(A3 width 297mm/except when ultra fine) Password YES (Max. 20 digits)
(2) Transmission mode document load quantity scan (3) Time specification
cycle (RSPF capacity)
Time specification: Time is specified in transmission/polling.
RSPF/OC NO (Selection inhibited during scanning of a Transmission/polling
transmission select document) Call time in memory 30sec / 45sec / 60 sec
Continuous auto YES send Default: 45 sec
paper feed
Document load RSPF: 100 sheets (4) Recall mode
capacity Auto recall mode Interval 1min to 15min, default 3min
Document scan cycle 40 pages/min (Normal, A4R memory when other party Number of 1 to 10 times / No resend
transmission) is busy. times Default 2 times
Document scan About 1.5sec/page (Normal, A4R memory Recall mode Interval 1min to 15min / 0: Resend
speed transmission) when in a immediately after disconnection of
Job build (Large YES communication the line
document mode) error Default: 1 min
Slow scan mode YES Number of 1 to 5 times / No resend
times Default: Once
Send page Page with which the error occurred
3. Image process system Number of transmissions Max. 50 items
(1) Half-tone reproduction density adjustment counted in recall mode
simultaneously.
Half-tone Equivalent to 256 gradations (Combination
of fine/super fine/ultra fine is possible.) Subsequent transmission NO
reservation override in recall
Exposure selection Auto/manual in 5 steps
mode
(2) Image selection
(5) Automatic reduction transmission
Standard 8dot/mm x 3.85line/mm
YES (ON/OFF by key operator program)
Fine 8dot/mm x 7.7line/mm
Super fine 8dot/mm x 15.4line/mm
Ultra fine 16dot/mm x 15.4line/mm: ITU-T conforming
AR-FX7 SPECIFICATIONS 2 - 1
(6) Memory transmission/direct transmission (14) Bulletin board (remote transmission, polling
Memory transmission YES transmission functions)
Number of reservation Max. 50 items Bulletin board YES
to be set (remote
Process in memory full Transmission cancel or only transmission)
scanned data transmission Polling protection Check by other party’s number YES
Quick online transmission YES (Enable/Disable setup by key function Check by matching of system number YES
operator program) (user’s own machine), ID number
Direct transmission YES (100 pages from RSPF, only 1
(other party’s machine) (between
page from OC) Sharp machines only)
Default setup Set by key operator program
F code bulletin YES
(7) Broadcast function board
Broadcast Number of 200 destinations (When group F code bulletin Registered up to 10 boxes
transmission destinations dialing is used, the number of board box
other parties registered to group F code bulletin Registered up to 36 letters (18 letters are
dialing is added.) board box name displayed)
Transmission 10-key, rapid key dialing, group
method key, next address key 6. Reception function system
Usable dial 10-key entry, rapid key dialing,
group key dialing. (1) Reception mode
However, an address including Default setup Automatic reception (Reception
sub address of 10-key entry state switchable)
registered cannot be used. Automatic Automatic YES
Group dialing Transmitted by group dialing reception reception setup
registered to rapid key dialing Number of calls 0 to 9 times (Factory default 2
Relay Instructing Only from the machine having times)
broadcast station Sharp relay broadcast Non-call reception Allowed by setting the number of
transmission instructing transmission function calls to 0.
Relay station Only from the machine having Manual reception setup YES
Sharp relay broadcast Setup for switching to automatic 0 to 9 times (Factory setup 0
transmission function reception time) (France only)
Multi-stage relay NO Auto reduction setup in letter NO
Number of relay 10 groups reception
groups Auto reduction setup in A3 NO
F code relay broadcast YES reception (A3 RX REDUCE)
instruction (relay broadcast Answering machine connection NO
instruction function) Reception mode time switch NO
F code relay broadcast (relay YES Reception data print condition Set whether the received data
function) setup are reduced or divided to print,
Confidential transmission (Sharp Only Sharp machine having by the key operator program.
machine mode) (Other party) confidential function
Confidential transmission (F code F code support machine
(2) Zoom reception
communication) (Other party) Auto reduction print on the YES (ON/OFF by key operator
paper size program)
(8) Scan specification
Page division YES (Allowed only from OC)
(3) Memory reception function
Applicable size: A3/B4/A4R Memory delayed receiving Only when output is disabled.
Page linkage NO Forced memory receiving NO
(9) Priority function (4) Received data skip output
Transmission reservation interrupt YES (check by job status key) YES
Broadcast interrupt YES (by direct transmission) (5) Transfer
(10) Multiple message transmission Transfer destination YES (Registered by key operator
Multiple message transmission NO registration program)
Transfer procedure YES (Operated by function menu)
(11) Rotation transmission
Paper size A4 → A4R, A5R → A5,
(6) Specified number reception
8.5 x 11 → 8.5 x 11R Only designated number NO
receiving enabled.
(12) Book document transmission
Reception reject setup YES (ON/OFF by key operator
Transmission method By OC mode (ANTI JUNK FAX) program)
(13) Finish stamp Registration of the 50 items (up to 20 digits each)
numbers to be rejected Registered by key operation program.
NO
AR-FX7 SPECIFICATIONS 2 - 2
(7) Confidential function Program Number of items 8 items
Confidential reception (Sharp Sharp machine having confidential Registerable All items during transmission except
machine mode) (Sender) function only items time specification/original/document
Confidential box Registered up to 10 boxes size/duplex/job build.
Confidential box name Registered up to 36 letters (18 Registered name 36 letters
letters displayed) Call method By pressing program key
Confidential ID code Set per confidential box Change in setup NO (Change in setup is available for
Confidential (F code F code support machine after calling time specification/document size/
communication) (Sender) original/duplex/job build. (Cannot set
F code confidential box Registered up to 10 boxes duplex/job build if select dual page
F code confidential box name Registered up to 36 letters (18 scan when setting.))
letters displayed) Relay Number of items 10 groups
F code confidential box print YES (4 digits) group Registered name 36 letters
pass code Relay station 10-key only
number
(8) Rotation reception registration
Paper is outputted by rotating 90 degrees to the set direction of Reception 10-key dialing
paper in cassette station number (Input the number that registered in
(9) Division reception registration relay station for rapid/group/speed
dial)
Division size When a long original is received, machine
outputs the data according to the condition set (2) Sender registration
through key operator program. Sender’s name 20 items (registration/display: 22 letters)
Registered by key operator program.
(10) Duplex reception
Sender’s number 20 digits, registered with key operator program
YES
(3) Polling (Registration of allow number)
(11) 2 in 1 reception
Registration of 10 items, 20 digits, registered by key operator
NO
polling allow program
(12) Polling number
Send request YES System number 1 items, 4 digits, registered by key operator
Resolution Ultra Fine (Change by the soft SW) registration program
Registration of Up to 10 items in 4 digits. Registered by key
(13) Turn around transmission polling allow ID operator program.
NO number
Relay ID code 10 items, 20 digits, registered by key operator
7. Registration system registration program
AR-FX7 SPECIFICATIONS 2 - 3
Transmission complete sound YES (Set by key operator program Transmission message (U.K.)
tone setup (transmission end) to PATTERN 1/2/3.) (Regular message) CONFIDENTIAL/PLEASE.
Transmission complete sound YES (Set by key operator program DISTRIBUTE/URGENT/PLEASE
tone setup (reception end) to PATTERN 1/2/3.) CALL BACK/IMPORTANT
Transmission complete sound YES (Set by key operator program.
time setup 2.0/2.5/3.0/3.5/4.0 sec.) (France)
Scan end sound YES (Set by soft switch.) COFIDENTIEL/
VEUILLEZ DISTRIBUER
Tone pulse switch Cancel tone/pulse switch set by the
URGENT
key operator program.
VEUILLEZ RAPPELER
Set with the service switch.
IMPORTANT
External telephone YES
connection
(Germany)
Remote YES (Switch number is in 1 digit + VERTRAULICH
reception switch ∗∗) 5∗∗
BITTE VERTEILEN
Telephone/ Sound NO EILIG
Fax response BITTE RÜCKRUF
Answering NO WICHTIG
voice recording Sender print NO
User message NO
9. Memory system
Memory capacity Standard 2MB
11. Additional print function when
Option 8MB receiving
Memory content LCD display YES
Index print YES (Set by key operator program)
(transmission Printout YES
reservation)
confirmation 12. Recording table system
Memory use status YES (% display) (1) Communication record function
Document data memory backup YES (Flash memory)
Communication record A4 (Not output when paper larger than
in power failure
table size A5 is not set.)
Communication record 50 items in total of transmission and
10. Additional information function for memory capacity reception
transmission Communication record Max. 50 items for each of transmission
table and reception (Total of transmission and
Page counter YES reception is up to 50 items.) Record table
Date printing YES (day/month/year/the day of is outputted separately. If registration
week, year is in 4 digits) exceeds 50, the oldest one is deleted.
Date/ display sequential NO Time-specified output YES (1 time per day)
switch Output when YES (Print/not print is set by key
Cover Date YES recording memory full operator)
paper item Receiver’s YES Output of individual YES (Communication time of each
name department department is outputted as department
Receiver’s YES management record table.)
number Time-specified Common with transmission record table
Sender’s YES communication table
name Confidential reception YES
Sender’s YES check table
number
(2) Communication result report function
Display of YES
number of Commu- Single sending YES (Print out all report/Print out
documents nication error report only/No printed report.
transmitted result With key operator program)
Transmission YES table Broadcast YES (Print out all report/Print out
message communication error report only/No printed report.
Print paper A4 report With key operator program)
size Reception YES (Print out all report/When error
occurs/No printed report. With key
operator program)
Confidential YES (Print out notice page/Not print
reception out notice page. With key operator
program)
Image memory print YES (Print out all report/When error
occurs/No printed report. With key
operator program)
AR-FX7 SPECIFICATIONS 2 - 4
(3) Other report list
Rapid # list YES (Rapid key table)
Group list YES (Group number table)
Telephone number list YES (Table of searched
letters in rapid key dialing,
and group dialing in
alphabetical order)
Program list YES
Relay group list YES
Transmission message list NO
Pass code list YES
Mem. polling list YES
Confidential reception list YES
Activity report YES
Timer list YES
Confidential code list YES
FAX key operator program list YES
FAX account usage list YES
F code memory box list YES
Junk FAX number list YES
Soft switch list (Output by SIM) YES
Memory image deletion table NO
Department code table NO
13. Others
CSI transmission YES
Department Limitation on users YES
management in each department
Number of 100 items
departments
registered
Charge NO
management
function for each
department
Automatic booting mode NO
WIN FAST YES
Distinctive ring NO
Summer time setting YES (Start: the last Sunday in
March 1:00 → 2:00
End: the last Sunday in
October 1:00 → 0:00)
(Default: ON)
Address book import/export In Japanese and English
PC-FAX Supplied languages: English,
French, Swedish, Italian,
Spanish, German, Dutch,
Danish, Finish/Norwegian
(TX only to RX. not available)
AR-FX7 SPECIFICATIONS 2 - 5
[3] INSTALLATION PROCEDURE 2) Work the left rear cabinet.
Cut and remove the cut-out portion from the left rear cabinet using
a tool such as nippers.
1. Install of expansion kit Be careful about the direction of the tool so that the cut surface is
A. Parts included flat.
Cut-out portion
Quick reference
Installation manual: Operation manuals:
booklet: 1pc.
1 sheet 1 pc.
(For SEN, SEB)
Spacers
Shielding plate
Screws
Screws
Left rear cabinet
Spacers
TEL/LIU PWB
Screws
Shielding plate
Insert the power plug of the copier to the outlet and turn
6) Reattach the left rear cabinet.
on the main switch. Then, carry out the following
<1> Pass the speaker harness through the hole of the frame of the fax procedure.
expansion PWB and connect it to the connector of the fax PWB.
9) Clear the image memory.
<2> Fit the pawls of the left rear cabinet to the mounting portions of
* If an extended memory (AR-MM9) has been mounted in step 7, be
the main unit. Slide the cabinet toward the front of the main unit to
sure to carry out this step.
attach it.
If no extended memory has been mounted, this step is not neces-
<3> Secure the left rear cabinet using two screws. sary.
<4> Attach the supplied fax connector cover. <1> [P], [*], [C], and [*] to enter the simulation mode.
Speaker harness Screws <2> Use the 10-key pad to enter “66” in the main code entry screen
shown below and press the START key.
<3> Use the 10-key pad to enter “10” in the sub-code entry screen
shown below.
Screw <4> Use the 10-key pad to enter “1” in the submenu screen shown
Pawls below and press the START key.
Line cable
COPY
ON LINE
PRINT
DATA
SCAN DATA
LINE
FAX
DATA
JOB STATUS CUSTOM SETTINGS
ACC.#-C
6 7 8 9 10 11 12
1 2 3 4
READY TO SEND.
SPEAKER REDIAL
14 FAX MEMORY:100% ADDRESS
AUTO AUTO RECEPTION 5
13 EXPOSURE BOOK
10 9
AR-FX7 ADJUSTMENTS 4 - 1
No. Name Function, operation
1 Message display Messages appear here to indicate the current status of the machine. When the machine is ready to send, an
icon appears to the left.
2 Memory and reception This shows the amount of fax memory that is free and the currently selected reception mode.
mode display
3 [SPEAKER] key This key is used for dialing with the speaker.
During dialing it changes into the [PAUSE] key, and after pressing the [SUB ADDRESS] key it changes into the
[SPACE] key.
4 [REDIAL] key Touch this key to redial the most recently dialed number. After dialing, this key changes into the [NEXT
ADDRESS] key.
5 [ADDRESS BOOK] key This displays the Address Directory screen.
Touch this key when you want to use an auto-dial number (one-touch dialing or group dialing).
6 [SUB ADDRESS] key Touch this key to enter a sub-address or passcode.
7 [ADDRESS REVIEW] key When performing a broadcast transmission, touch this key to check your selected destinations. A list of your
selected destinations will appear, and destinations can be deleted from the list.
8 [DIRECT TX MEMORY Touch this key to switch from memory transmission mode to direct transmission mode.
TX] key The selected mode is highlighted.
9 [SPECIAL MODES] key Touch this key to select one of the following special functions:
Timer transmission, Polling, Slow scan mode, Dual page scan, Program, Memory box, Cover sheet,
Adding a message, Special modes
10 Original settings icon When two-sided scanning or job build mode is selected (touch the [ORIGINAL] key to select these functions), an
display icon will appear in this display.
The icon can be touched to open the original settings screen.
11 [ORIGINAL] key Touch this key to manually set the original size or select two-sided scanning.
12 [RESOLUTION] key Touch this key to change the resolution setting when scanning an original. The selected resolution setting will be
highlighted above the key. The initial factory setting is [STANDARD].
13 [EXPOSURE] key Touch this key to change the scanning exposure. The selected exposure is highlighted above the key. The initial
factory setting is [AUTO].
14 Special function icon When a special function such as polling or dual page scan is selected, the special function icon appears here.
display
READY TO SEND.
SPEAKER REDIAL
A B CONDITION
SETTINGS
3
C D
1 SUB ADDRESS
E F
ADDRESS REVIEW
G H
5 4
AR-FX7 ADJUSTMENTS 4 - 2
[5] ADJUSTMENTS
Section Adjustment items Adjustment procedures
1 Density section A FAX mode density adjustment (Overall mode) <FAX mode> SIM 46-12
B FAX mode density adjustment (Individual mode) <FAX mode> SIM 46-13 – 46-16
2 Communication section A Dial test <FAX mode> SIM 66-14, 66-16
Glass holding plate 2) Switch to the FAX mode and execute SIM 46-13 to 46-16 depend-
ing on the adjustment mode.
2) Switch to the FAX mode and execute SIM 46-12. 3) After warming up, shading is performed and the current density
3) After warming up, shading is performed and the current density level is displayed on the lower two digits of the display section.
level is displayed on the lower two digits of the display section in 4) Enter the set value with the 10-key to adjust the FAX image den-
standard and auto density mode. sity.
4) Enter the set value with the 10-key to adjust the FAX image den- 5) Make a copy, and adjust the density with the copy as a reference.
sity.
<Adjustment specifications>
5) Make a copy, and adjust so that the following adjustment specifica-
tion is satisfied. Resolution Density Set
SIM Set value
mode changeover range
∗ When an adjustment is made in this mode, the exposure level for
each communication mode and each density mode are automatically Standard Switched with the FAX The greater the 0 – 99
adjusted accordingly. density select mode 46- set value is, the
key. 13 greater the density
<Adjustment specifications>
Fine Switched with the FAX is, and vice versa.
CCITT #3 density select mode 46-
Density Resolution Set
SIM chart output Set value key. 14
mode mode range
result Super fine Switched with the FAX
Auto Standard FAX “3” is slightly The greater the 0 – 99 density select mode 46-
mode copied. set value is, the key. 15
46-12 greater the density Ultra fine Switched with the FAX
is, and vice versa. density select mode 46-
key. 16
AR-FX7 ADJUSTMENTS 5 - 1
2. Communication section
Note: These items are factory adjusted when shipping according to
FCC standards. Therefore, do not change the setting in the mar-
ket.
3) Enter the set value with the 10-key, and press the [START] key.
Soft Initial
SIM Set value
SW value
DTMF High (FAX SW 64- –6dBm SW set value: 1dBm
trans- group mode) 66- 4 to 8 0 to 21 step
mission 16 Transmission (Binary
level (Test level: 0.0 to input)
only) –21dB
High SW 65- +2.0 SW set value: 0.5dBm
group 5 to 8 dBm 0 to 15 step
– Transmission (Binary
Low level: 2.0 to input)
group 5.5dB
AR-FX7 ADJUSTMENTS 5 - 2
[6] SIMULATION Code
Function
Main Sub
1. Code-type simulation 66 17 Used to check the DTMF signal send operation.
(Signal send level: Max.)
A. Operating procedures and operations 18 Used to check the DTMF signal send operation.
* Entering the simulation mode (Signal send level: Set by soft SW.)
19 Used to write the SRAM data to the Flash ROM.
1) #/P key (program) ON → Asterisk (*) key ON → CLEAR key ON →
Asterisk (*) key ON → Ready for input of a main code of simulation 20 Used to write the Flash ROM data to the SRAM.
21 FAX information print
2) Entering a main code with the 10-key → START key ON
22 Handset sound volume adjustment (Japan only)
3) Entering a sub code with the 10-key → START key ON
24 Used to clear the FAST storage data. (SEC only)
4) Select an item with the scroll key and the item key.
30 Used to set the TEL/LIU.
5) The machine enters the mode corresponding to the selected item. 31 Used to set the TEL/LIU.
Press START key to start the simulation operation. 32 Receive data check
To cancel the current simulation mode or to change the main code 33 Signal detection check
and the sub code, press the CUSTOM SETTINGS key. 34 Communication time measurement display
* Canceling the simulation mode to return to the normal mode 37 Speaker sound volume adjustment
1) Press CLEAR ALL key. 41 CI signal check
52 Ringer check
2. Simulation code list
Code 3. Details
Function
Main Sub
22 5 Used to check the ROM version of each unit
(section). 22
11 Used to display the FAX send/receive counter
(FAX reception and print counter).
22-5
24 10 FAX counter data clear
46 12 FAX exposure level adjustment (1 mode automatic Purpose Adjustment/Setting/Check
adjustment) Function Used to check the ROM version of each unit (section).
13 FAX exposure level adjustment (Normal mode (Purpose)
individual adjustment) Item Software
14 FAX exposure level adjustment (Fine text mode
Operation/procedure
individual adjustment)
15 FAX exposure level adjustment (Super Fine mode Used to display the ROM version of each section.
individual adjustment) [Display example]
16 FAX exposure level adjustment (Ultra Fine mode ROM version 1.250 → [1.25] (up to 2 decimal places)
individual adjustment) The display of the protocol monitor and the soft SW follows this dis-
48 8 FAX magnification adjustment (read) play.
9 FAX magnification adjustment (print) S/N Machine serial number
50 8 FAX lead edge adjustment (read) MCU Main Control Unit
9 FAX lead edge adjustment (print) IMC IMC
66 1 Used to change and check the FAX-related soft OPE Panel + Panel label code
SW. PRINTER PRINTER
2 Used to clear the FAX-related soft SW. (Except for NIC NIC (For the Soft Nic, the Soft Nic version is displayed.
the FAX adjustment values) When the AR-NC5 is installed, the AR-NC5J version is
3 FAX PWB memory check displayed.)
4 Signal send mode (Signal send level: Max.) FINISHER FINISHER
5 Signal send mode (Signal send level soft SW FAX FAX
setting)
If it is not installed, "- - - - - - - - - -" is displayed.
6 Printing the confidential password
[Label code display]
7 Print the screen memory contents
Contents of "XXX" section on the display below
8 Voice Message send (Signal send level: Max.)
(print) (Japan only) Panel Panel software support
Destination Selection code
9 Used to send the voice message. (Signal send display language
level: Set by soft SW.) JPN Japan Japanese, American
10 Image data memory clear English, English
11 Used to send 300bps signals. (Signal send level: EFS SEC AJ/AM American English, English,
Max.) SECL AL/AC French, Spanish
12 Used to send 300bps signals. (Signal send level: SUK BK/BB
Set by soft SW) EEU SEEG/ GG/GD English, German, Polish,
13 Used to register the dial numbers. SEA/East Czech, Hungarian, Greek,
14 Used to perform the dial test. (10 PPS send test) Europe, Turkish, Russian, French,
etc. Italian, Slovak
15 Used to perform the dial test. (20 PPS send test)
16 Used to perform the dial test. (DTMF signal send
test)
AR-FX7 SIMULATION 6 - 1
Panel Panel software support
display
Destination Selection code
language
24
NEU SEF/ BG/DG/ English, German, French,
SEES/ BD/DD Spanish, Dutch, Italian, 24-10
SEIS/SEN, Portuguese, Swedish,
Purpose Data clear
etc. Norwegian, Finnish,
Danish Function (Purpose) FAX counter data clear
SCA/SCNZ BA/BN American English, English, Section FAX
Distributor French, Spanish Item Counter
area Operation/procedure
CHN SOCC BZ UE5 Simplified Chinese, 1. Select the "3: NUMBER OF PRINTS", and press the [START] key.
American English, English The confirmation menu is shown.
TWN Taiwan BE/BT UT1 Traditional Chinese (Local 2. Select "1: YES."
support), American 1: YES (Cleared)
English, English 2: NO (Not cleared) (Default)
EFS *1 Special American English, English, Item Content
countries French, Spanish, Hebrew
1 FAX SEND FAX send page and time
(Local support) (PAGE & TIME)
*1: Display at the current state
2 FAX RECEIVE FAX receive page and time
(PAGE & TIME)
3 FAX OUTPUT FAX output (number of prints)
Note: Executable only when the FAX is installed.
46
22-11 46-12
1
50
AR-FX7 SIMULATION 6 - 2
46-13 Note: Executable only when the FAX is installed.
Purpose Adjustment
Function FAX exposure level adjustment (Normal mode
(Purpose) individual adjustment) 1
Section FAX
Item Image quality
Operation/procedure
1. Select "1: COPY START."
The currently set value is displayed beside the item.
2. Enter the set value of the exposure level with the 10-key, and
press the [#/P] key. 46-15
3. Press the [START] key. Purpose Adjustment
Copying is started and the set value is stored. Function FAX exposure level adjustment (Super Fine mode
Normal display NOW PRINTING (Purpose) individual adjustment)
Error display DOOR OPEN Section FAX
JAM Item Image quality
PAPER EMPTY Operation/procedure
There is no tray selection operation. 1. Select "1: COPY START."
The optimum paper tray for the scanned size is selected. The currently set value is displayed beside the item.
Item Content Setting range Default 2. Enter the set value of the exposure level with the 10-key, and
1 COPY START Copy start – – press the [#/P] key.
2 EXP.LEVEL Exposure level 3. Press the [START] key.
selection Copying is started and the set value is stored.
0-99 50
3 AE Normal text AE Normal display NOW PRINTING
4 MANUAL Normal text MANUAL Error display DOOR OPEN
Note: Executable only when the FAX is installed. JAM
PAPER EMPTY
There is no tray selection operation.
The optimum paper tray for the scanned size is selected.
1 Setting
Item Content Default
range
1 COPY START Copy start – –
2 EXP.LEVEL Exposure level selection
3 AE (PHOTO ON) Super Fine AE (Half
46-14 tone)
Purpose Adjustment 4 AE (PHOTO OFF) Super Fine AE
0 - 99 50
Function FAX exposure level adjustment (Fine text mode 5 MANUAL Super Fine MANUAL
(Purpose) individual adjustment) (PHOTO ON) (Half tone)
Section FAX 6 MANUAL Super Fine MANUAL
(PHOTO OFF)
Item Image quality
Note:Executable only when the FAX is installed.
Operation/procedure
1. Select "1: COPY START."
The currently set value is displayed beside the item.
2. Enter the set value of the exposure level with the 10-key, and
press the [#/P] key. 3
1
3. Press the [START] key. 50
Copying is started and the set value is stored. 50
50
Normal display NOW PRINTING
50
Error display DOOR OPEN
JAM
PAPER EMPTY
46-16
There is no tray selection operation.
Purpose Adjustment
The optimum paper tray for the scanned size is selected.
Function FAX exposure level adjustment (Ultra Fine mode
Setting (Purpose) individual adjustment)
Item Content Default
range
Section FAX
1 COPY START Copy start – –
Item Image quality
2 EXP.LEVEL Exposure level
Operation/procedure
selection
3 AE (PHOTO ON) Fine text AE (Half tone) 1. Select "1: COPY START."
The currently set value is displayed beside the item.
4 AE (PHOTO OFF) Fine text AE
0-99 50 2. Enter the set value of the exposure level with the 10-key, and
5 MANUAL (PHOTO Fine text MANUAL (Half
ON) tone) press the [#/P] key.
6 MANUAL (PHOTO Fine text MANUAL
OFF)
AR-FX7 SIMULATION 6 - 3
3. Press the [START] key. Setting
Copying is started and the set value is stored. Item Content Default
range
Normal display NOW PRINTING 4 OC(SUB) SCAN Sub scanning 1-255* 128
Error display DOOR OPEN magnification ratio
JAM adjustment (OC)
PAPER EMPTY 5 SPF(MAIN) SCAN Main scanning 1-255* 128
magnification ratio
There is no tray selection operation.
adjustment (SPF)
The optimum paper tray for the scanned size is selected.
6 SPF(SUB) SCAN Sub scanning 1-255* 128
Setting magnification ratio
Item Content Default
range adjustment (SPF)
1 COPY START Copy start – – 7 RSPF(MAIN) SCAN Main scanning 1-255* 128
2 EXP.LEVEL Exposure level selection magnification ratio
3 AE (PHOTO ON) Ultra Fine AE (Half adjustment (RSPF)
tone) 8 RSPF(SUB) SCAN Sub scanning 1-255* 128
4 AE (PHOTO OFF) Ultra Fine AE magnification ratio
0 - 99 50 adjustment (RSPF)
5 MANUAL Ultra Fine MANUAL
(PHOTO ON) (Half tone) * The adjustment can be made in the range of -12.7% - +12.7% by the
6 MANUAL Ultra Fine MANUAL increment of 0.1%.
(PHOTO OFF) Note: Executable only when the FAX is installed.
Note: Executable only when the FAX is installed.
1
2
128
1 128
50 128
50 128
128
50
128
50
48-9
48 Purpose Adjustment
Function (Purpose) FAX magnification adjustment (print)
Section FAX
48-8
Operation/procedure
Purpose Adjustment 1. Select "1: COPY START."
Function FAX magnification adjustment (read) The currently set value is displayed beside the item.
(Purpose) 2. Press the [START] key.
Section FAX Copying is started and the set value is stored.
Related soft SW SW112-1 to 8, SW113-1 to 8
Normal display NOW PRINTING
Operation/procedure Error display DOOR OPEN
1. Select "1: COPY START." JAM
The currently set value is highlighted beside the item. PAPER EMPTY
2. Enter the set value of magnification with the 10-key, and press the There is no operation of tray selection.
[#/P] key.
The optimum paper tray for the scanned size is selected.
3. Press the [START] key.
When two pages are scanned, duplex printing is made.
Copying is started and the set value is stored.
Setting
Normal display NOW PRINTING Item Content Default
range
Error display DOOR OPEN
1 COPY START Copy start 1-255 128
JAM
PAPER EMPTY 2 Horizontal Print magnification ratio 1-255 128
adjustment (Horizontal, vertical
There is no operation of tray selection.
to paper passing)
The optimum paper tray for the scanned size is selected. 3 Vertical Print magnification ratio 1-255 128
Even when the SPF/RSPF is selected, if there is no original on the adjustment (Vertical, parallel to
SPF/RSPF, the OC is scanned. paper passing)
Even when the OC is selected, if there is any original on the SPF/ 4 Horizontal Print magnification ratio 1-255 128
RSPF, the SPF/RSPF is scanned. (Setting 2) (DUPLEX) adjustment on the back surface
Setting (Horizontal, vertical to paper
Item Content Default passing)
range
1 COPY START Copy start – – 5 Vertical Print magnification ratio 1-255 128
2 SCAN SELECT Scan selection (OC/ 1-255* 128 (DUPLEX) adjustment on the back surface
(OC/SPF/RSPF) SPF/ RSPF) (Vertical, parallel to paper
3 OC(MAIN) SCAN Main scanning 1-255* 128 passing)
magnification ratio Note: Executable only when the FAX is installed.
adjustment (OC)
AR-FX7 SIMULATION 6 - 4
50-9
Purpose Adjustment
Function (Purpose) FAX lead edge adjustment (print)
128
2 Section FAX
128 Operation/procedure
128
1. Select "1: COPY START."
128
The currently set value is highlighted beside the item.
2. Press the [START] key.
Copying is started.
Normal display NOW PRINTING
Error display DOOR OPEN
50 JAM
PAPER EMPTY
50-8 There is no tray selection operation.
The optimum paper tray for the scanned size is selected.
The adjustments on the machine side must have been normally
completed. When two pages are scanned, duplex print is made,
Purpose Adjustment Setting
Item Content Default
Function (Purpose) FAX lead edge adjustment (read) range
1 COPY START Copy start – –
Section FAX
2 LEAD Print lead edge void 43-57 50
Operation/procedure
adjustment value (Front
1. Select "1: COPY START." surface)
The currently set value is highlighted beside the item. 3 LEFT Print left edge void 43-57 50
2. Enter the correction value with the 10-key, and press the [#/P] key. adjustment value (Front
3. Press the [START] key. surface)
Copying is started. 4 REAR Print rear edge void 43-57 50
Normal display NOW PRINTING adjustment value (Front
Error display DOOR OPEN surface)
JAM 5 LEAD Print lead edge void 43-57 50
(DUPLEX) adjustment value (Back
PAPER EMPTY
surface)
There is no tray selection operation.
6 LEFT (DUPLEX) Print left edge void 43-57 50
The optimum paper tray for the scanned size is selected.
adjustment value (Back
4. Select the scanning method. surface)
Even when the SPF/RSPF is selected, if there is no original on the 7 REAR Print rear edge void 43-57 50
SPF/RSPF, the OC is scanned. (DUPLEX) adjustment value (Back
Even when the OC is selected, if there is any original on the SPF/ surface)
RSPF, the SPF/RSPF is scanned. (Setting 2) Note: Executable only when the FAX is installed.
Setting
Item Content Default
range
1 COPY START Copy start – –
2 SCAN Scan selection (1: OC, 2:
SELECT (OC/ SPF, 3: RSPF back) 1-3 1 1
SPF/RSPF)
3 LEAD Scan lead edge position
adjustment value of the 43-57 50
selected method in 2.
4 LEFT Scan left edge position
adjustment value of the 43-57 50
selected method in 2.
5 REAR Scan rear edge position
adjustment value of the 43-57 50 66
selected method in 2.
6 RIGHT Scan right edge position 66-1
adjustment value of the 43-57 50
selected method in 2. Purpose Setting
Function Used to change and check the FAX-related soft SW.
Note: Executable only when the FAX is installed.
(Purpose)
Section FAX
Operation/procedure
2 1. Enter the soft SW number to be selected with the 10-key.
50 2. Check and change the setting content of the selected soft SW.
50 3. Press the [START] key to save the set content.
50
The FAX-related soft SW is displayed on the LCD, and changing can
be made by monitoring it.
Note: Executable only when the FAX is installed.
AR-FX7 SIMULATION 6 - 5
2. Detailed procedure
1 "55H" is written to all the addresses of each memory, and the
address data are read in sequence to check that they were
properly written.
1 2 "AAH" is written to all the addresses of each memory, and the
address data are read in sequence to check that they were
properly written.
3 "00H" is written to all the addresses of each memory, and the
66-2 address data are read in sequence to check that they were
Purpose Adjustment properly written.
Function Used to clear the FAX-related soft SW. (Except for the 4 Perform checks 1 - 3 sequentially. If there is no abnormality, it is
(Purpose) FAX adjustment values) "OK." If there is any abnormality, "NG" is notified to the error
Section FAX address.
5 After completion of check, the memory is returned to the initial
Operation/procedure
state.
1. Enter the country code with the 10-key, and press the [START] (CPU is not reset)
key.
Interruption cannot be made during operation.
2. When "1: (YES)" is selected, the soft SW corresponding to the
Note: Executable only when the FAX is installed.
country code is cleared. When "2: (NO)" is selected, the simulation
is canceled.
Country code
Japan : 00000000 India : 01010011 1
U.S.A./Canada : 10110101 Hong Kong : 01010000
Australia : 00001001 Spain : 10100000
U.K. : 10110100 Portugal : 10001011
France : 00111101 Italy : 01011001
Germany : 00000100 Switzerland : 10100110
Sweden : 10100101 Finland : 00111100 66-4
New Zealand : 01111110 Denmark : 00110001
Purpose Operation test/check
China : 00100110 Norway : 10000010
Function Signal send mode (Signal send level: Max.)
Singapore : 10011100 Netherlands : 01111011
(Purpose)
Taiwan : 11111110 Luxembourg : 01101001
Section FAX
Middle East : 11111101 Belgium : 00001111
Item Operation
Malaysia : 01101100
Operation/procedure
The codes other than the above are accepted as Japan.
Select the signal number with the 10-key, and press the [START] key.
Note: Executable only when the FAX is installed.
The signal is sent to the line and the machine speaker. (Sending the
signal is continued until the [CUSTOM SETTINGS] key is pressed.)
By entering the signal number and pressing the [START] key during
execution, the signal kind can be changed.
1 2 3 4 5 6 7 8
Send level
0000100 1 Item Send signal Selection
menu
1 NO SIGNAL Signal not sent None
2 33.6 V34 – –
3 31.2 V34 – –
66-3 4 28.8 V34 – –
Purpose Operation test/check 5 26.4 V34 – –
Function (Purpose) FAX PWB memory check 6 24.0 V34 – –
Section FAX 7 16.0 V34 – –
Item Operation 8 19.2 V34 – –
Operation/procedure 9 16.8 V34 – –
Press the [START] key. 10 14.4 V34 – –
Read/write can be checked for FAX PWB memory. 11 12.0 V34 – –
The check result is displayed separately for each memory. 12 9.6 V34 – –
13 7.2 V34 – –
1. Memory to be checked
14 4.8 V34 – –
DRAM
15 2.4 V34 – –
SRAM
16 14.4 V33 – –
Flash ROM Program area SUM check only
17 12.0 V33 – –
Memory area
18 14.4 V17 – –
Option memory The memory size follows the
19 12.0 V17 – –
automatically detected value.
20 9.6 V17 – –
PAGE
21 7.2 V17 – –
22 9.6 V29 – –
23 7.2 V29 – –
24 4.8 V27t – –
AR-FX7 SIMULATION 6 - 6
Send level Send level
Item Send signal Selection Signal number Send signal Selection
menu menu
25 2.4 V27t – – 12 9.6 V34 9.6 V34 –
26 0.3 FLG 7EH Flag signal Yes 13 7.2 V34 7.2 V34 –
27 CED2100 Tone signal Yes 14 4.8 V34 4.8 V34 –
28 CNG1100 15 2.4 V34 2.4 V34 –
29 0.3 V21 16 14.4 V33 14.4 V33 –
30 ANSam 17 12.0 V33 12.0 V33 –
31 RINGER Pseudo-ringer sound None 18 14.4 V17 14.4 V17 –
([ON HOOK] key ON) 19 12.0 V17 12.0 V17 –
32 No MSG Voice message (no sound) None 20 9.6 V17 9.6 V17 –
Under the state where the ring back 21 7.2 V17 7.2 V17 –
tone can be sent to the line, keep the 22 9.6 V29 9.6 V29 –
sound composition IC volume to 0. 23 7.2 V29 7.2 V29 –
33 No RBT Ring back tone (no sound) None 24 4.8 V27t 4.8 V27t –
Under the state where the ring back 25 2.4 V27t 2.4 V27t –
tone can be sent to the line, keep the
26 0.3 FLG 7EH Flag signal Yes
G/A volume to 0.
27 CED2100 Tone signal Yes
34 DP MAKE Dial pulse (make) 1: 0dB
28 CNG1100
Maintain the make state with keeping 2: Soft SW
29 0.3 V21
the condition to be able to send to the
30 ANSam
dial pulse line.
31 RINGER Pseudo-ringer sound None
35 DP BRK Dial pulse (break) 1: 0dB
([ON HOOK] key ON)
Maintain the break state with keeping 2: Soft SW
32 No MSG Voice message (no sound) None
the condition to be able to send to the
dial pulse line. Under the state where the ring back
Note: Executable only when the FAX is installed. tone can be sent to the line, keep the
sound composition IC volume to 0.
33 No RBT Ring back tone (no sound) None
Under the state where the ring back
tone can be sent to the line, keep the
1 G/A volume to 0.
34 DP MAKE Dial pulse (make) 1: 0dB
Maintain the make state with keeping 2: Soft SW
the condition to be able to send to the
dial pulse line.
35 DP BRK Dial pulse (break) 1: 0dB
Maintain the break state with keeping 2: Soft SW
the condition to be able to send to the
dial pulse line.
66-5
Note: Executable only when the FAX is installed.
Purpose Operation test/check
Function Signal send mode (Signal send level soft SW setting)
(Purpose)
Section FAX 1
Item Operation
Operation/procedure
Select the signal number with the 10-key, and press the [START] key.
By setting the signal number, signals are sent to the line and the
machine speaker. (Sending signals is continued until interruption com-
mand is made (by pressing [CUSTOM SETTINGS] key.)
By entering the signal number and pressing the [START] key during
execution, the signal kind can be changed. 66-6
Send level Purpose Data output, check
Signal number Send signal Selection Function (Purpose) Printing the confidential password
menu Section FAX
1 NO SIGNAL Signal not sent None Item Data Confidential/Pass code
2 33.6 V34 33.6 V34 –
Operation/procedure
3 31.2 V34 31.2 V34 –
Press the [START] key.
4 28.8 V34 28.8 V34 –
The confidential ID table (confidential BOX numbers, confidential BOX
5 26.4 V34 26.4 V34 –
names, and confidential password) is printed.
6 24.0 V34 24.0 V34 –
The confidential data of My company mode is printed separately.
7 16.0 V34 16.0 V34 –
8 19.2 V34 19.2 V34 – Note: Executable only when the FAX is installed.
9 16.8 V34 16.8 V34 –
10 14.4 V34 14.4 V34 –
11 12.0 V34 12.0 V34 –
AR-FX7 SIMULATION 6 - 7
66-9
Purpose Operation test/check
Function Used to send the voice message. (Signal send level:
(Purpose) Set by soft SW.) (Japan only)
Section FAX
Item Operation
Operation/procedure
66-7 Select the message number with the 10-key, and press the [START]
key.
Purpose Data output, check
Function (Purpose) Print the screen memory contents By setting the message No., the sound message is sent to the line and
the speaker of the body. (The message is repeated until the interrup-
Section FAX
tion command is provided by pressing the [CUSTOM SETTINGS] key.)
Item Data Image data
By pressing the [START] key during execution, the signal kind can be
Operation/procedure
changed.
Press the [START] key.
Item Voice message
Used to input all image data (including confidential reception data,
1 NONE Silent
remote send image, not-sent image) stored in image memory of the
2 FAX/TEL MSG1 "Hold the line a minute, please send fax."
FAX section.
(TEL/FAX voice response)
The output image is remained even after outputting.
3 FAX/TEL MSG2 "Hold the line a minute."
Note: Executable only when the FAX is installed. (TEL/FAX voice response)
4 FAX/TEL MSG3 "Not around here, please send fax."
(TEL/FAX voice response)
5 CHANGED RX MSG "Ding Dong"
1 (Sound delivered when switching to remote
reception)
6 RINGER Call sound
7 EXT.TEL RINGER External telephone call
66-8 Message No. 5 can be heard by an external telephone speaker.
Purpose Operation test/check Note: Executable only when the FAX is installed.
Function (Purpose) Voice Message send (Signal send level:
Max.) (Japan only)
Section FAX
Item Operation 2
Operation/procedure
Select the message number with the 10-key, and press the [START]
key.
By setting the message No., the sound message is sent to the line and
the speaker of the body. (The message is repeated until the interrup-
tion command is provided by pressing the [CUSTOM SETTINGS] key.) 66-10
By pressing the [START] key during execution, the signal kind can be
changed. Purpose Adjustment/Setting/Check
Function (Purpose) Image data memory clear
Item Voice message Section FAX
1 NONE Silent Item Data Image data
2 FAX/TEL MSG1 "Hold the line a minute, please send fax." Operation/procedure
(TEL/FAX voice response) Select "1: YES" with the 10-key and press the [START] key. (When "2:
3 FAX/TEL MSG2 "Hold the line a minute." NO" is selected, the simulation is canceled.)
(TEL/FAX voice response) Used to clear all image data (including confidential reception data)
4 FAX/TEL MSG3 "Not around here, please send fax." stored in image memory of the FAX section.
(TEL/FAX voice response)
The management table is also cleared (initialized) at the same time.
5 CHANGED RX MSG "Ding Dong"
* lIf there is any print data, the power must be turned off after clearing.
(Sound delivered when switching to remote
reception) Note: Executable only when the FAX is installed.
6 RINGER Call sound
7 EXT.TEL RINGER External telephone call
Message No. 5 can be heard by an external telephone speaker. 1
Note: Executable only when the FAX is installed.
AR-FX7 SIMULATION 6 - 8
66-11
Purpose Operation test/check
Function Used to send 300bps signals. (Signal send level: 1
(Purpose) Max.)
Section FAX
Item Operation
Operation/procedure
Select the signal number with the 10-key, and press the [START] key.
By setting the signal number, the specified signal is delivered to the 66-13
line at the speed of 300bps. (The signal is continuously sent until the
Purpose Setting
interruption command is provided by pressing the [CUSTOM SET-
Function (Purpose) Used to register the dial numbers.
TINGS] key.)
Section FAX
The signal send level can be selected from 0dB or the soft SW set
Item Operation
value.
Operation/procedure
The signal send level is returned to the soft SW set value before exe-
cution of the mode after completion of the mode. Enter the number with the 10-key, [*] key, and [#] key.
By entering the number and pressing the [START] key during execu- Press the [CLEAR] key to return to the initial state.
tion, the signal kind can be changed. Press the [START] key to register the entered number.
Item Note: Executable only when the FAX is installed.
1 NO SIGNAL
2 11111
3 11110
4 00000
5 010101
6 00001
Note: Executable only when the FAX is installed.
66-14
Purpose Operation check/test
1 Function Used to perform the dial test. (10 PPS send test)
(Purpose)
Section FAX
Item Operation
Operation/Procedure
66-12 1. Select the item with the 10-key, and press the [START] key.
Purpose Operation test/check 2. Set the make time with the 10-key.
Function Used to send 300bps signals. (Signal send level: Set The dial is sent with the set value + 26ms.
(Purpose) by soft SW) The sending dial cannot be interrupted.
Section FAX
Item Content Setting range
Item Operation
0 EXECUTE Execution –
Operation/procedure
1 MAKE TIME Dial pulse make time setting 0-15
Select the signal number with the 10-key, and press the [START] key.
Note: Executable only when the FAX is installed.
By setting the signal number, the specified signal is delivered to the
line at the speed of 300bps. (The signal is continuously sent until the
interruption command is provided by pressing the [CUSTOM SET-
TINGS] key.) 1
The signal send level can be selected from 0dB or the soft SW set
value.
The signal send level is returned to the soft SW set value before exe-
cution of the mode after completion of the mode. 66-15
By entering the number and pressing the [START] key during execu- Purpose Operation check/test
tion, the signal kind can be changed. Function Used to perform the dial test. (20 PPS send test)
Item (Purpose)
1 NO SIGNAL Section FAX
2 11111 Item Operation
3 11110 Operation/Procedure
4 00000 1. Select the item with the 10-key, and press the [START] key.
5 010101 2. Set the make time with the 10-key.
6 00001
The dial is sent with the set value + 26ms.
Note: Executable only when the FAX is installed.
The sending dial cannot be interrupted.
Item Content Setting range
0 EXECUTE Execution –
1 MAKE TIME Dial pulse make time setting 0-15
Note: Executable only when the FAX is installed.
AR-FX7 SIMULATION 6 - 9
Note: Executable only when the FAX is installed.
66-16
66-19
Purpose Operation check/test
Function Used to perform the dial test. (DTMF signal send test) Purpose Back up
(Purpose) Function Used to write the SRAM data to the Flash ROM.
Section FAX (Purpose)
Item Operation Section FAX
Operation/Procedure Item Data
1. Select the item with the 10-key, and press the [START] key. Operation/Procedure
2. Enter the set value with the 10-key. Select "1: YES" with the 10-key, and press the [START] key. The data
The sending dial cannot be interrupted. are backed up. (When "2: NO" is selected, the simulation is canceled.)
* The AR-FX5 data cannot be written into the AR-FX7. If it is exe-
Setting cuted, data are initialized and deleted. In addition, the AR-FX7 data
Item Content
range cannot be used in the AR-FX5.
0 EXECUTE Execution – Note: Executable only when the FAX is installed.
1 HIGH (SW) High group 0-15
2 HIGH-LOW (SW) High group, Low group 0-15
3. Select the soft SW reflection.
Item Content
1 NO STORE TO SW Not reflected.
2 STORE TO SW Reflected. (Shift SW value changed.)
Note: Executable only when the FAX is installed.
66-20
Purpose Back up
Function Used to write the Flash ROM data to the SRAM.
1 (Purpose)
Section FAX
Item Data
Operation/Procedure
66-17
Select "1: YES" with the 10-key, and press the [START] key. The Flash
Purpose Operation check/test ROM data are read out and written into the SRAM. (When "2: NO" is
Function Used to check the DTMF signal send operation. selected, the simulation is canceled.)
(Purpose) (Signal send level: Max.) * The AR-FX5 data cannot be written into the AR-FX7. If it is exe-
Section FAX cuted, data are initialized and deleted. In addition, the AR-FX7 data
Item Operation cannot be used in the AR-FX5.
Operation/procedure Note: Executable only when the FAX is installed.
Enter the DTMF signal (1 digit (1 to 9, 0, *, #)) and press the [START]
key.
When the [CUSTOM SETTINGS] key is pressed during execution, the
simulation is terminated.
Note: Executable only when the FAX is installed.
66-21
Purpose Check
Function (Purpose) FAX information print
Section FAX
Item Data
Operation/procedure
66-18
1. Select the item to be printed.
Purpose Operation check/test 2. Press the [START] key.
Function Used to check the DTMF signal send operation.
The information of the selected item is printed.
(Purpose) (Signal send level: Set by soft SW.)
Item Content
Section FAX
1 USER SW.LIST User setting list
Item Operation
2 SOFT SW.LIST Soft SW list
Operation/Procedure
3 SYSTEM ERROR System error list
Enter the DTMF signal (1 digit (1 to 9, 0, *, #)) and press the [START]
Used to print the system error log (error
key.
number and time).
When the [CUSTOM SETTINGS] key is pressed during execution, the
simulation is terminated.
AR-FX7 SIMULATION 6 - 10
Item Content 66-30
4 PROTOCOL Protocol error list
Purpose Operation test/check
Regardless of soft SW38-1 status, the
Function (Purpose) Used to set the TEL/LIU.
protocol monitor of the preceding
Section FAX
communication is printed. (Printing is
allowed at any time before starting the Item Operation
next communication.) For this operation, Operation/procedure
the protocol monitor of one When the relay state of the polarity reverse relay, the handset hook
communication is always buffered. switch, or the external telephone hook switch is changed, the content
Note: Executable only when the FAX is installed. of change is displayed regardless of the soft SW setup (real time). The
display of change is kept until an interruption command is supplied by
pressing the [CUSTOM SETTINGS] key.
Notification contents
Item
Signal low Signal high
HS2 ON OFF
HS1 ON OFF
RHS ON OFF
EXHS ON OFF
66-22 Note: Executable only when the FAX is installed.
Purpose Setting
Function Handset sound volume adjustment (Japan only)
(Purpose)
Section FAX
Item Operation
Operation/procedure
1. Select the set volume. (Max., Middle, Min.)
66-31
2. Press the [START] key.
Switch of 1, 2, and 3 can be made during execution of the simulation. Purpose Setting
During execution of the simulation, sounds are generated. Function (Purpose) Used to set the TEL/LIU.
Section FAX
Note: Executable only when the FAX is installed.
Item Operation
Operation/Procedure
1. Enter the set value. (Valid only 0 to 8)
2. The entered bit is alternatively switched between "0" and 1" and
the target signal name is highlighted.
3. Press the [START] key to send the signal.
When the [CUSTUM SETTINGS] key is pressed, the output is termi-
66-24 nated.
Note: Executable only when the FAX is installed.
Purpose Data clear
Function Used to clear the FAST storage data. (SEC only)
(Purpose)
1 2 3 4 5
Section FAX
00001
Item Data Initializing
Operation/procedure
Select "1: YES" with the 10-key and press the [START] key. The FAST
storage data are cleared. (When "2: NO" is selected, the simulation is
canceled.) 66-32
Note: Executable only when the FAX is installed.
Purpose Operation test/check
Function (Purpose) Receive data check
Section FAX
Item Operation
Operation/procedure
The fixed data received from the line are checked and the result is dis-
played.
When data are coincident, "OK" is displayed. When not, "NG" is dis-
played.
Note: Executable only when the FAX is installed.
AR-FX7 SIMULATION 6 - 11
66-33 1. Sound kinds pattern
Sound kinds (Test sound) Sound volume set value
Purpose Operation test/check
RINGER Call sound DEF. LAR. MED. SMA.
Function (Purpose) Signal detection check
LINE MONITO Line monitor sound (Test DEF. LAR. MED. SMA.
Section FAX
sound: communication
Item Operation
signal sound)
Operation/Procedure
ON HOOK On-hook (Test sound, DEF. LAR. MED. SMA.
Signal detection is checked and the result is displayed. communication signal
Note: Executable only when the FAX is installed. sound)
SCAN FINISH Scan finish sound DEF. LAR. MED. SMA.
TX/RX FINISH Communication finish DEF. LAR. MED. SMA.
sound
DTMF DTMF send sound DEF. LAR. MED. SMA.
LAR: (MED. Value + 1)
MED: (SMA value +1) - (LAR value - 1)
SMA: 1 - (MED. Value + 1)
2. Sound volume pattern
Note: Executable only when the FAX is installed.
66-34
Purpose Operation test/check
Function (Purpose) Communication time measurement display 1
Section FAX
Item Operation
Operation/procedure
The send/receive test is performed, and the time required for send/
receive of the image data in the test is measured and displayed. 66-41
Setup on the user Communication : Memory send
Purpose Adjustment/Setting/Check
side when executing means : Normal Character
communication Picture quality : Lighter Function CI signal check
Density : ON (Purpose)
ECM : OFF Operation/procedure
Sender information When the [START] key is pressed, the call signal from CI pin is
Measuring Send From flag reception before sending of detected to deliver the call sound to the line and the speaker. The vol-
range image data until sending of RCP frame ume of call sound follows the soft SW.
Receive From flag reception before reception of Signal detection and delivery of pseudo-call sound at detection are
image data until reception of RCP frame executed until the interruption command is provided by pressing the
Mode when measuring Used to make communication not in a [CUSTOM SETTINGS] key.
simulation process but in the normal screen Note: Executable only when the FAX is installed.
and measure the time.
How to check the time Enter the simulation for communication time
check and check the time.
Measuring unit msec
When there are two or more send/receive operations of image data in
one communication, only the time of the last send/receive data near
the end is measured.
Note: Executable only when the FAX is installed. 66-52
Purpose Operation test/check
Function Ringer check
(Purpose)
Operation/procedure
When the [START] key is pressed, the machine ringer and the pseudo-
ringer would ring.
By pressing [CUSTOM SETTINGS] key, the operation can be can-
66-37 celed.
Purpose Adjustment/Setting/Check
Function (Purpose) Speaker sound volume adjustment
Section FAX
Operation/procedure
The following test sound is delivered to the line and the speaker to
adjust the sound kind and volume.
The send level to the line is the set value of soft SW.
The set values of the selected sound kind and volume are written to
each soft SW.
AR-FX7 SIMULATION 6 - 12
[7] SOFT SWITCH
1. FAX soft switch setting change quick reference table
Large item Middle item Switch content Key operator Soft SW No. Usage
Dialing Remote machine Pause time Default setting SW 28-1 – 4 When dialing disable/when error dialing
call disable Dial call signal Default setting SW 22-5, 6 When dialing disable
DTMF-related item None SW 64-4 – 8 When dialing disable in PBX (private branch
exchange/Fax service, etc.)
None SW 65-5 – 8 When dialing disable in PBX (private branch
exchange/Fax service, etc.)
None SW 26-1 – 5 When dialing disable in PBX (private branch
exchange/Fax service, etc.)
Pulse (10PPS) None SW 25-1 – 4 When pulse dialing disable
Signal detection Busy tone detection None SW 21-2 When busy tone detection disable
Busy tone detection cycle None SW 51-1 – 2 When busy tone error is detected
Dial tone detection None SW 21-1
Redial In case of an error Resend interval Transmitter SW 14-5 – 8 When send errors occur frequently
function setting
In case of an error Number of times of resend Transmitter SW 14-1 – 4
function setting
When busy Resend interval Transmitter SW 13-5 – 8 Whey busy occurs frequently
function setting
When busy Number of times of resend Transmitter SW 13-1 – 4
function setting
Arrival (Call-in) When CI detection CI detection None SW 86-2, 3 No call-in
disable CI signal OFF detection time None SW 87-1 – 7 No call-in
External Setting of an Yes/No Default setting SW 41-1 When an external telephone is connected
telephone external telephone
connected
Remote switch Entry of a 2-digit number Default setting SW 7-1 – 8 When remote switch is erroneously detected
number
Remote switch Yes/No None SW 6-8 When remote switch is erroneously detected
setting
Communication General Send level None SW 15-4 – 8 When the remote machine cannot receive
signals in a proper level.
JBIG mode None SW 17-4, 8 When an error occurs in the JBIG mode
SG3 V34 mode function setup None SW 43-1 When SG3 communication error occurs
frequently
V34 symbol rate None SW43-4 – 6 When SG3 communication error occurs
frequently
Transmission G3/SG3 DIS reception check One-touch/ SW 69-8 When an error occurs in phase B
Reduction, etc.
Line equalizer None Setting is made referring to the distance from
the station when a communication trouble
occurs.
SG3 V34 send speed One-touch/ When an error occurs in the SG3
Reduction, etc. communication.
Manual send V34 None SW 42-8 When an error occurs in the SG3
communication in FAX service, etc.
G3 V29 no modulation carrier None When an error occurs in the V29
communication
Modem send speed One-touch/ SW 16-1 – 4 To specified/unspecified destination
Reduction, etc.
RTN reception error None SW 73-1 When judged as “OK” though RTN is received
Reception G3/SG3 CSI transmission None
Maximum reception length None When a document of 1m or longer is received
Proxy reception None
EQM dispersion inhibit None When a lot of errors occur due to the poor
conditions of the line.
SG3 V34 reception speed None When fall-down occurs frequently in the SG3
communication
G3 Countermeasure against None When an error occurs in phase B in reception
echo in reception
Modem speed in reception None SW 16-5, 6 When the line quality is poor and a fall-back
or an error occurs
EYE-Q check only None SW 72-7 Change in the detection method of training
error
2. Soft SW list
∗ When a value outside the set range is inputted, the default is automatically set.
∗ Never change the switch whose item is specified as inhibition.
∗: UK = U.K., G = Germany, F = France
SW Data ∗
Items SW selection and functions Default value Remarks
No. No. UK G F
1 Country information Binary
input Bit No. 1 2 3 4 5 6 7 8 1 0 0
Japan (00000000)
2 U.S.A. / Canada (10110101)
Australia (00001001) 0 0 0
U.K. (10110100)
3 France (00111101)
Germany (00000100) 1 0 1
Sweden (10100101)
4 New Zealand (01111110)
China (00100110) 1 0 1
Singapore (10011100)
The initial value
S Taiwan (11111110)
5 differs
W Middle East (11111101)
depending on 0 0 1
1 Malaysia (01101100)
the destination.
India (01010011)
6
Hong Kong (01010000)
1 1 1
Spain (10100000)
Portugal (10001011)
7
Italy (01011001)
0 0 0
Switzerland (10100110)
Finland (00111100)
8 Denmark (00110001)
Norway (10000010)
Netherlands (01111011) 0 0 1
Luxembourg (01101001)
Belgium (00001111)
1 SIM language Bit No. 1 2
0 0 0
information Japanese 0 0 English
2 English 0 1 0 0 0
3 Language information Binary 0 0 0 For English, the
4 input Bit No. 3 4 5 6 7 8 0 0 0 proper character
S 5 1: English is determined by
3: French 0 0 0 destination
W The initial value
2 6 4: German information.
differs 0 1 0
5: Italian
depending on
6: Dutch
7 the destination.
7: Swedish 1 0 1
8: Spanish
8
9: Portuguese 0 0 1
16: Finnish
3. Soft switch descriptions SW5 No. 3 Flash memory check measuring range
Operation check usually can be done by 256-byte check. Setting to 1
SW1 No.1–No.8 Country information will check all areas of the flash memory. Note that it takes about 20
Destination setup min.
SW2 No.1, No.2 SIM language information Default: 0 (256 bytes)
SIM language selection SW5 No. 4 ICU UART1 output
SW2 No.3–No.8 Language information Used to set whether ICU UART 1 output is made or not.
Language selection Default: 1 (Output is not made)
SW3 No. 1 Sharp machine mode SW5 No.5–No.8 24V reset wait time
Sharp machine mode setup Used to set the 24V reset wait time.
Default: 1 (ON) The set range is 0 to 750 by binary input.
Default: 500ms
SW3 No. 2 Sharp machine mode (F code)
Sharp machine mode (F code) setup SW6 No. 1 Auto/Manual default setup
Default: 0 (OFF) Used to select Auto/Manual reception mode when turning on the
power. (When no external telephone is connected, do not select Man-
SW3 No. 3 FAST mode ual. However, setup is possible and reception can be made by on-
Used to set Enable/Disable of FAST operation. (SEC only) hook.)
This SW must be set to enable FAST operation by the serviceman. When set to 1, manual reception.
Default: 0 (NO) When set to 0, auto reception.
SW3 No. 4 Center number in FAST Default: 0 (Auto reception)
Center number setup in FAST SW6 No. 2 Inhibited to use.
Default: 0 (Service-No.) SW6 No.3, No.4 Size specification
SW3 No.5–No.7 Maintenance cycle Used to set inch series or AB series for recording paper when printing
Setup for judgment of consumable parts notification when using the received documents.
F.A.S.T. function. Normally there is no need to change from “Follow the machine infor-
This setup should be the same as SIM21-1 setup. mation.”
Default: 0 0 1 (75K) Default: 0 1 (follows the machine information)
SW3 No. 8 Maintenance system SW6 No. 5 Inhibited to use.
Setting of the machine model for judgment of consumable parts sys- SW6 No. 6 Memory transmission/direction transmission
tem in the FAST function default setup
Default: 0 (AR) Used to select Memory/Direction transmission when the power is
SW4 No.1–No.8 Inhibited to use. turned on and the time out is cleared.
When set to 1, direct transmission is selected when the power is turned
SW5 No. 1 Initialization control inside program
on and the time out is cleared.
Used to set whether the all soft switches are initialized or not.
When set to 0, memory transmission is selected when the power is
When set to 1, the initialization is made. turned on and the time out is cleared.
When set to 0, No initialization is made. Default: 0 (Memory transmission)
Default: 0 (nothing is made)
SW6 No. 7 Quick memory transmission
SW5 No. 2 For FAX debug Used to set whether quick memory transmission (transmission of ring-
Used to set ON/OFF of FAX debug mode. ing before completion of scanning) is performed or not. Linked with the
When set to 1, debug mode is ON. key operator program menu.
When set to 0, debug mode is OFF. Default: 1 (Allowed)
Default: 0 (Debug mode OFF)
SW9 No. 2 Transfer function SW10 No. 4 Yes/No of SEP capacity in reception
Used to set whether transfer function is allowed or not. Used to set notification of YES/NO of DIS signal Bit 47 SEP capacity.
Default: 1 (allowed) "1": Inhibited
"0": Allowed
SW9 No. 3 Relay broadcast function
Default: 0 (allowed)
Used to set whether the interface broadcasting command is received
from the other party to perform interface broadcasting or the interface When set to 1 (NO), F code polling is inhibited.
broadcasting command is not received from the other party. SW10 No. 5 Yes/No of reception PWD capacity
When set to 1, the relay broadcast instruction from the allowed party is Used to set whether password function is judged or not for F code bul-
received. letin board polling.
When set to 0, the relay broadcast instruction even from the allowed "1": Password is not judged. Password is disregarded and communi-
party is not received. cation is allowed.
Default: 1 (The relay broadcast instruction is received.) "0": Password is judged. If password is not acceptable, communica-
Though this function is set to disable, the interface broadcasting com- tion is cut off.
mand can be sent. Default: 0 (Password is judged.)
SW9 No. 4 – No.5 Inhibited to use. SW10 No. 6 Yes/No of SID capacity in reception
SW9 No. 6 Cover function default setup Used to set whether password is judged or nor in F code reception.
Used to set whether the cover is added or not in transmission. "1": Password is not judged. Password is disregarded and communi-
When set to 1, the cover is added. cation is allowed.
When set to 0, the cover is not added. "0": Password is judged. If password is not acceptable, communica-
tion is cut off.
Default: 0 (The cover is not added.)
Default: 0 (Password is judged.)
SW9 No. 7 Specified number reception
SW10 No. 7 Judgment of the system number of bulletin
Used to set ON//OFF the function to reject the fax reception from the
specified numbers.
board transmission
Used to set whether the condition of coincidence between the system
Default: 0 (Ignore specified number reception)
number of this machine and that of the other party machine is
SW9 No. 8 Specified number reception in manual employed as a criterion to judge whether to allow bulletin transmission
reception by receiving polling transmission from the other party machine made
Used to set whether reception from manual reception is rejected or not by our company.
when reception function by specifying the number is ON. "1": When the system number of the other party machine made by our
Default: 1 (Reject specified number reception) company coincide with the system number of this machine, poll-
ing is allowed.
"0": Though the system number of the other party machine made by
our company coincide with the system number of this machine,
polling is inhibited.
Default: 0 (Inhibited)
SW17 No. 7 ECM MMR mode (SG3) SW21 No. 3 Dial tone monitoring time
Used to set whether MMR encoding system is allowed or not in SG3 Used to set dial tone monitoring time when detecting dial tone.
communication. "1": 10sec
When set to 1, MMR encoding system is allowed. "0": 5sec
When set to 0, MMR encoding system is inhibited. Default: 0 (5sec)
Default: 1 (MMR encoding system is allowed) SW21 No. 4 CED detection time
SW17 No. 8 ECM JBIG mode (SG3) Used to set CED/ANSam signal detection time. When the CED/
Used to set whether JBIG encoding system is allowed or not in SG3 ANSam signal is detected for duration of the set time, it is recognized.
communication. When set to 1, if a signal is detected for 500ms or more, it is recog-
When set to 1, JBIG encoding system is allowed. nized.
When set to 0, JBIG encoding system is inhibited. When set to 0, if a signal is detected for 1000ms or more, it is recog-
nized.
Default: 1 (JBIG encoding system is allowed)
Default: 0 (1000ms or more)
SW18 No.1–No.4 Setup of number of times of call rings
SW21 No.5–No.8 Inhibited to use.
Used to set the number of call rings until reception is started in auto
reception mode. SW22 No.1, No.2 Waiting time for dial start
Setup is in the range of 0 – 9 (times) by binary input. Used to set wait time from connection of the line to start of dial ringing.
When set to 0, no ring is made. When ringing is made without detecting dial tone, ringing is made after
Default: 2 times setting this time.
When set to 0 0, ringing is made after 3.5sec.
SW18 No.5–No.8 Inhibited to use.
When set to 0 1, ringing is made after 4sec.
SW19 No.1–No.4 Minimum pause time (10PPS) setup When set to 1 0, ringing is made after 5sec.
Used to set the minimum pause time (10PPS).
When set to 1 1, ringing is made after 6sec.
Setup is made in the range of 0 (525ms) – 15 (900ms) by binary input
Default: 3.5sec.
of N in "X (ms) = (N × 25) + 525".
Default: 825ms SW22 No.3, No.4 CNG send start time
Used to set the CNG send start time.
SW19 No. 5–No.8 Inhibited to use.
Default: 0 0 (0.5 sec)
SW20 No. 1 Inhibited to use.
SW22 No.5, No.6 Tone/pulse default setup
SW20 No. 2–No.4 PBX setup (Inhibited except for Use line setting (Dial setting)
Germany and France.) Selection of 10PPS, 20PPS, and TONE is available.
Used to select send signal of register recall.
The setup items are as follows:
In concrete, ID (pulse signal up to 3 digits) and Flash (1-pulse signal)
bit 5 6
are selected.
0 0 : 10PPS
Default: 0 0 0 (Setup OFF) 0 1 : 20PPS
SW20 No. 5 SIM DTMF sound speaker selection window 1 0 : TONE
Used to set YES/NO of SIM DTMF sound speaker selection screen. Default: 1 0 (Tone)
Default: 0 (NO) SW22 No. 7 DPMUTE control
SW20 No.6, No.7 Flash send wait time Used to set whether DPMUTE control is used or not.
Used to set wait time from off-hook status to Flash signal transmission 1: ON
in the register recall function. 0: OFF
Default: 0 0 (0sec) (U.K, France) 1 0 (1sec) (Germany) Default: 0 (OFF)
(Fixed to 0 except for Germany.)
Used to set the report output on less than A4 (LTR). SW34 No. 5 Communication report output (in confidential
Default: 0 (Reduction by the record volume) reception)
Used to set whether the communication report table is outputted or not
SW33 No. 3 Own FAX No. mark of TX image
when a confidential reception is made.
Used to set own number’s mark in TX image header. (English only)
When set to 1, the communication report table is printed.
When set to 1, mark is TEL icon ( ).
When set to 0, the communication report table is not printed.
When set to 0, mark is “FAX:”.
Default: 1 (Print)
Default: 0 (FAX:)
SW34 No.6, No.7 Report output (In broadcast, sequential
SW33 No.4, No.5 Contents of send document are printed send request, and relay broadcast)
in memory send
Used to set whether the communication report table is outputted or not
Used to set Print/Not print part of the sent document in the transmis- after the transmission (in broadcast, sequential send request, and
sion result table in case of a memory transmission error. relay broadcast).
When set to 0 0, the transmitted document is not printed on the trans- Setup is selected from "print inhibition," "all output," and "only the
mission result table. address to which transmission is failed" as follows:
When set to 0 1, all the transmitted document are printed on the trans- bit 6 7
mission result table.
0 0 : Print is inhibited.
When set to 1 0, the transmitted document is printed on the transmis- 0 1 : Print all
sion result table only when the transmission is failed.
1 0 : Only the address to which transmission is failed
Default: 1 0 (when the transmission is failed)
Default: 0 1 (All print)
SW33 No. 6 Transmission document content print in F
SW34 No. 8 Report output when canceling
code transmission
Used to set whether the communication report table is outputted or not
Used to set whether the sent document content is print or not in F code
when canceling transmission during document transmission.
transmission.
When set to 1, the communication report table is printed.
SW33-4 – 5 must be set to output.
When set to 0, the communication report table is not printed.
Default: 1 (Not print)
Default: 0 (No print)
SW36 No.1–No.4 Waiting time for PC-FAX job end SW38 No. 3 Protocol monitor save
Used to set the waiting time for PC-FAX job end. Used to set whether the protocol monitor of the final communication is
saved or not.
The set range is 0 (32 min) to 15 (2 min) in the increment of 2 min by
binary input. When set to "Saved," the preceding protocol monitor can be printed
with SIM 66-21.
Default: 2 min.
Default: 1 (Save)
SW36 No.5, No.6 Inhibited to use.
SW38 No.4, No.5 Line sound monitor range
SW36 No.7, No.8 Waiting time for lift-up Used to set the line sound monitor range when the line monitor func-
Used to set the wait time before starting printing when the cassette is tion is used.
being lift up in print ready state.
Used to set to monitor NSF signal send/receive until NSF signal is
Default: 0 0 (30 sec) sent/received.
SW37 No. 1 Thin paper setup When set to ALL, all procedures up to line disconnection are moni-
Used to set whether the thin paper use is allowed or not. tored.
Default: 0 (Inhibited) The setup items are as follows:
bit 4 5
SW37 No. 2 Specification of 1m scan when there is no line
0 0 : OFF
send setting
0 1 : Until NSF signal is sent/received
Used to set “Reception specification of 1m” when SW37-3 – 6 (Rota-
1 0 : All
tion transmission selection) is set to NO.
1 1
Default: 0 (Normal operation)
Default: 0 1 (Up to NSF signal send/receive)
SW37 No. 3 Rotation send selection (A4 → A4R)
SW38 No. 6 Line monitor display
Used to set whether A4 document is transmitted as A4 or the scanned
Used to set whether the communication speed and the reception level
image is rotated and transmitted as A4R.
are displayed on the LCD or not.
When set to 1, the document is transmitted as A4 width.
Displayed on the communication status screen by pressing the job sta-
When set to 0, the document is transmitted as A3 width. tus key.
Default: 1 (Transmitted as A4 width) When set to 1, displayed on LCD.
SW37 No. 4 Rotation transmission selection (B5R → B5) When set to 0, not displayed on LCD.
Used to set whether B5R document is transmitted as B5R or the Default: 0 (not displayed)
scanned image is rotated and transmitted as B5.
SW38 No. 7–No. 8 Inhibited to use.
When set to 1, the document is transmitted as B4 width (B5).
When set to 0, the document is transmitted as A4 width (B5R).
Default: 1 (Transmitted as B4 width)
Pattern of scan end sound volume (Large/Medium/Small) SW51 No. 5 Busy tone detection time (Lower limit 2)
Default: 21 Busy tone detection time lower limit 2
1: 150ms 0: Follows SW51-4.
Default: 0 (Follows SW51-4)
SW52 No.1, No.2 DT/BT detection frequency range SW64 No.1–No.3 Inhibited to use.
Used to set the DT/BT detection frequency range. SW64 No.4–No.8 DTMF send level (high level)
Default: 0 1 (420Hz to 680Hz) Used to set the DTMF signal send level (high group).
SW52 No. 3 Busy tone detection level table 0 (0.0dBm) to 21 (–21.0dBm) in the increment of 1dBm
Used to set the busy tone detection level table. Default: –6dBm
Used to set the lowest detection level when detecting busy tone. Setup is made in the range of 0 (0.0dBm) to 15 (–15.0dBm) by binary
input.
When set to 0 0, busy tone of –43dB is detected.
The setup is made in the increment of 1dB.
When set to 0 1, busy tone of –35dB is detected.
Default: 0dBm
When set to 1 0, busy tone of –33dB is detected.
When set to 1 1, busy tone of –30dB is detected. SW65 No.5–No.8 DTMF send level (difference between
This setting is made when busy tone is erroneously detected.
high and low level)
Used to set the DTMF signal send level (low group).
Default: 0 0 (–43dB)
0 (–2.0dBm) to 15 (+5.5dBm) in the increment of 0.5dBm
SW52 No.6–No.8 Inhibited to use.
Default: +2.0dBm
SW53 No.1–No.8 Inhibited to use.
SW66 No. 1 Default date, sender print
SW54 No.1–No.8 Inhibited to use. Used to set whether the registered sender information and date and
SW55 No.1–No.8 Inhibited to use. time of transmission are printed at the top of the transmission docu-
ment when a document is transmitted through the second line.
SW56 No.1–No.8 Inhibited to use. When set to 1, date and sender are printed.
SW57 No.1–No.8 Inhibited to use. When set to 0, date and sender are not printed.
SW58 No.1, No.2 Inhibited to use. Default: 1 (Date and sender are printed)
SW58 No.3–No.8 External connection sound volume SW66 No. 2 Department number notification
Used to set External connection sound volume. Used to set whether the department number is transmitted as sender
information when the department management function is enabled.
The set range is 0 (0.0dBm) to 48 (–24.0dBm) in the increment of
0.5dBm by binary input. Default: 0 (OFF)
When set to 49 or greater, the setup value comes as below. SW66 No. 3 Date and sender print position setup
49=–28.0dBm 50=–32.0dBm 51=–36.0dBm 52=–40.0dBm Used to set the print position of date and transmitter information on the
53=–48.0dBm 54=–56.0dBm 55=–63.0dBm 56 = – ∞ infinite (mute) transmitted documents.
Default: –10.0dBm When set to 1, added upper inside the document.
SW59 No.1–No.4 Signal send level Max. When set to 0, added outside the document.
Used to set Signal send level Max. Default: 0 (Added outside the document)
The set range is 0 (0dBm) to 15 (–15dBm) in the increment of 1dBm by SW66 No. 4, No. 5 Inhibited to use.
binary input. SW66 No.6–No.8 Polarity reversion settlement time
Default: –6dBm Used to set Polarity reversion settlement time.
SW59 No.5, No.6 Transmission cable amplitude equalizer Setup is made in the range of 200ms – 1600ms by binary input.
Used to set Transmission cable amplitude equalizer. Default: 200ms
Default: 0 0 (0dB) SW67 No.1–No.4 After sending CFR, double wait is
SW59 No.7, No.8 Reception cable amplitude equalizer inhibited for 1.6sec.
Used to set Reception cable amplitude equalizer. Used to set that the double wait is inhibited for 1.6sec. after sending
Default: 0 0 (0dB) CFR.
Setup is made in the range of 0ms – 3000ms by binary input.
SW60 No.1, No.2 Reception SED ON level
Default: 1600ms
Used to set Reception SED ON level.
Default: 1 1 (–48dB) SW67 No. 5 Measurement of communication time (image)
Used to set YES/NO of measurement.
SW60 No. 3 Inhibited to use.
Used to measure the communication time in phase C. However, it is
the communication time in the latest phase C. (Unit: msec)
Default: 1 (YES)
SW72 No.1, No.2 RCP send times SW75 No.1, No.2 Waiting time for CED send start
Used to set RCP send times. Used to set the waiting time for CED send start.
Default: 0 0 (3 times) Default: 0 0 (2.25 sec)
SW72 No.3–No.6 The number of the flag detection bytes SW75 No.3, No.4 CED signal send time
Used to set the number of the flag detection bytes. Used to set CED signal send time.
Setup is made in the range of 0 – 15 by binary input. Default: 0 0 (3 sec)
Default: 4 SW75 No.5, No.6 Waiting time for ANSam send start
Used to set the waiting time for ANSam send start.
Default: 0 0 (2.25 sec)
SW75 No.7, No.8 ANSam signal send time
Used to set ANSam signal send time.
Default: 0 1 (4 sec)
SW82 No. 1 CI signal ON time in V.8 mode SW88 No.1–No.8 Inhibited to use.
Used to set the CI signal ON time in V.8 mode. SW89 No. 1–No.8 Inhibited to use.
Default: 0 (9 bytes) SW90 No. 1–No.8 Inhibited to use.
SW82 No. 2 CI signal OFF time in V.8 mode SW91 No. 1–No.8 Inhibited to use.
Used to set the CI signal OFf time in V.8 mode.
SW92 No.1–No.8 Inhibited to use.
Default: 0 (1sec)
SW93 No.1–No.8 Inhibited to use.
SW82 No. 3 Inhibited to use.
SW94 No.1–No.8 Inhibited to use.
SW82 No.4, No.5 CI receive number to shift to non-V.34
communication SW95 No.1–No.4 Inhibited to use.
Used to set CI receive number to shift to non-V.34 communication. SW95 No.5–No.8 T1 timer setup
Default: 1 0 (2 times) Used to set time-out time from phase B to detection of signal.
SW82 No.6–No.8 CI send number to shift to Non-V.34 T1 time-out time is set in the range of 15 – 90sec (in the increment of
communication 5sec).
Default: 40sec
Used to set CI send number to shift to non-V.34 communication.
Setup is made in the range of 0 – 7 by binary input. SW96 No.1, No.8 Inhibited to use.
When set to 0, retrain is not made. SW97 No.1–No.8 Inhibited to use.
Default: 2
SW98 No.1–No.8 Inhibited to use.
SW83 No.1–No.8 Inhibited to use.
SW99 No.1–No.8 Inhibited to use.
SW84 No.1–No.8 Inhibited to use.
SW100 No.1–No.8 Inhibited to use.
SW85 No.1–No.8 Inhibited to use.
SW101 No.1–No.8 Inhibited to use.
SW86 No.1 Inhibited to use.
SW102 No.1–No.8 Inhibited to use.
SW86 No.2, No.3 CI detection
SW103 No.1–No.8 Inhibited to use.
Used to set the frequency to detect CI signal which is the calling signal
as follows: SW104 No.1–No.8 Inhibited to use.
bit 2 3 SW105 No.1–No.8 Inhibited to use.
0 0 : 4 sine wave SW106 No.1–No.8 Inhibited to use.
1 0 : 3 sine wave
0 1 : 2 sine wave SW107 No.1–No.8 Inhibited to use.
Default: 0 0 (4 sine wave) SW108 No.1–No.8 Inhibited to use.
SW86 No.4, No.5 CI delete max. OFF time SW109 No.1–No.4 Print lead edge adjustment (Left edge
Used to set the max. wait time from detection of CI signal pulse (num- adjustment)
ber of times) to the next CI signal pulse detection. If next CI signal Setup of print image area void
pulse is not detected within this time, the number of calls up to now is The quantity of void at the left edge in main scan direction can be
cleared. adjusted. When the set value is increased, the image void is increased.
The setup items are as follows: Setup of SIM 50-9 is reflected.
bit 4 5 0 to ±112 dots in the interval of 16 dots
0 0 : 5sec Default: 48 dots
0 1 : 10sec
1 0 : 15sec
SW109 No.5–No.8 Print lead edge adjustment (Lead edge
1 1 : 20sec
adjustment)
Setup of print image area void
Default: 0 1 (10 sec)
The quantity of void at the lead edge in sub scan direction can be
SW86 No.6–No.8 CI signal ON detection enable time adjusted. When the set value is increased, the image void is increased.
Used to set the time to judge that CI signal is ON. Setup of SIM 50-9 is reflected.
The CI signal of less than this setup time is not regarded as ON. 0 to ±112 dots in the interval of 16 dots
The set range is 0 (155ms) – 7 (225ms) in the increment of 10ms. Default: 48 dots
Default: 155ms
SW121 No.1–No.4 Scan effective image area (SPF) rear SW132 No.1–No.8 Inhibited to use.
horizontal left edge image loss SW133 No.1–No.8 Inhibited to use.
Used to set the left edge image loss of main scan in SPF scan of FAX.
Setup of SIM 50-8 is reflected.
0 to ±56 dots in the interval of 8 dots
Default: +0 dots
SW121 No.5–No.8 Scan effective image area (SPF) rear
horizontal right edge image loss
Used to set the right edge image loss of main scan in SPF scan of
FAX.
Setup of SIM 50-8 is reflected.
0 to ±56 dots in the interval of 8 dots
Default: +0 dots
SW122 No.1–No.8 Scan magnification ratio adjustment
SPF (horizontal)
SPF main scan magnification ratio adjustment
Setup of SIM 48-8 is reflected.
0 to ±12.7% by increment of 0.1%
Default: 0%
SW123 No.1–No.8 Scan magnification ratio adjustment
SPF (vertical)
SPF sub scan magnification ratio adjustment
Setup of SIM 48-8 is reflected.
0 to ±12.7% by increment of 0.1%
Default: 0%
SW124 No.1–No.8 Print magnification ratio adjustment
rear (horizontal)
Used to adjust the print magnification radio in main scan direction.
Setup of SIM 48-9 is reflected.
0 to ±12.7% by increment of 0.1%
Default: 0%
SCANNER
COPY SETTINGS PRINT SETTINGS FAX SETTINGS
SETTINGS
S
RECEIVE MODE
Far edge
Faxed Receiving
document machine’s Reduced size Ratio
5. Quick On-line
width paper width When the RSPF is used for memory transmission and there are no
11" x 17" 8-1/2" x 14" 8-1/2" x 14" 1 : 0.70 previously stored jobs waiting or in progress (and the line is not being
(Area ratio) used), the machine dials the destination and begins transmitting
scanned pages while the remaining pages are scanned. This transmis-
11" x 17" 8-1/2" x 11" 8-1/2" x 11"R 1 : 0.5
sion method is called Quick On-line. The messages "SCANNING
(Area ratio)
ORIGINAL." and "CONNECTING." both appear until scanning of the
8-1/2" x 14" 8-1/2" x 11" 8-1/2" x 11"R 1 : 0.64 final page is completed.
(Area ratio)
If the receiving party is busy when a Quick On-line transmission is
A document can also be faxed without reducing its size. In this case, attempted, the transmission will be automatically reattempted at a later
the left and right edges will not be transmitted. time.
NOTE:
4. Own number sending • The machine is initially set (factory setting) to perform Quick On-line
transmission. If desired, you can turn off this function in the key
This function prints the date, time, your programmed senderís name,
operator programs.
your programmed sender’s fax number, and the page number at the
• When an original is transmitted using the following methods, the job
top center of each page that you fax.
will be stored in memory (Quick On-line transmission will not be per-
Example of fax page printed out by the receiving machine formed):
MAY-11-200X-FRI 03:00 PM SHARP PLANNING DIV. FAX No.0666211221 P.001/001 1) Sending from the document glass
↑ ↑ ↑ ↑
1) 2) 3) 4) 2) Broadcast transmission
3) Timer transmission
1) Date and time: programmed in the custom settings.
4) F-code transmission
2) Sender’s name: programmed in the key operator programs.
3) Sender’s fax number: programmed in the key operator programs.
4) Page number: 3-digit number appearing in the format, "page num-
ber/total pages" (only the page number appears if you use manual
transmission or Quick On-Line transmission). If desired, you can
use a key operator program to have the page number omitted.
Direction of transmission
transmitted data
scanned data
Length of
Length of
Direction of transmission
transmitted data
scanned data
Length of
Length of
Outline of Version-up Procedure 4) Turn on the copier. The machine starts up in the download mode.
5) Additional tree will be visible when downloading maintenance pro-
(PC)
gram on PC.
C ∗ Make sure to start up maintenance program before turn on the
A
Download machine.
data
RS232C connector
(9pin or 25pin) Centro connector
B
RS232C cross cable
(D-sub 9pin to D-sub 9pin)
or Ready to start download process
(D-sub 25pin to D-sub 9pin) when these trees appear.
FAX-PWB
6) When downloading copier program, expand "Special(Copier)",
2 and double-click on "All Data areas Download".
(AR-M236/M276)
2. Others (Troubleshooting)
Followings are the error possibly occur during the download process and troubleshooting method.
No Warning/error message Detail
1 Incorrect destination. Continue with the Destination of download file and copier doesn't match.
download process? Possible to select either continue or cancel the job.
[TROUBLESHOOTING]
To change destination, select "Yes". If not, select "No" and cancel download process.
2 Incorrect download file. Invalid download file for the machine is selected, or the file format is not correct.
[TROUBLESHOOTING]
Confirm the download file. Possibly the improper download file is selected.
3 No downloadable data included. Unable to find appropriate data in selected download file.
[TROUBLESHOOTING]
Confirm the download file. Possibly the improper download file is selected.
4 This option not available. Download procedure is executed on uninstalled optional kit.
[TROUBLESHOOTING]
Confirm installed optional kit.
Confirm the download file. Possibly the improper download file is selected.
5 The data size exceeds the Flash ROM size. Panel flash ROM size is not enough to execute download procedure.
Try again with the appropriate size of data. [TROUBLESHOOTING]
Confirm the download file. Possibly the improper download file is selected.
Exchange the flash ROM to the one which has more capacity.
6 Time out error. Transmission error
Unable to receive data from the machine among the certain period of time.
[TROUBLESHOOTING]
Restart maintenance program after confirming communication port or communication cable.
7 Communication (incoming) error. Incorrect download procedure.
The machine did not proceed download procedure correctly.
[TROUBLESHOOTING]
Restart maintenance program after confirming communication port or communication cable.
Make sure the communication device of PC(either COM or parallel) is under right condition.
8 Checksum error. Transmission error
The check sum value of the transmission data is mismatch.
[TROUBLESHOOTING]
Restart maintenance program after confirming communication device of PC (either COM or
parallel) is under right condition.
9 Error during the download process. Error Download data file operation error.
code: 0xXXXXXXXX [TROUBLESHOOTING]
Restart maintenance program after confirming the selected download file is not abnormal and
not using other application.
10 An error. [0xXXXXXXXX] The error occurred except the above errors.
[TROUBLESHOOTING]
Restart maintenance program after confirming communication device of PC(either COM or
parallel) is under right condition.
Reso-
PRINT lution IMAGE
3x3 ROTA-
I/F con-
TING CPU FAX GA
version I/F I/F
PAGE
MEMORY
SDRAM SRAM
128Mbit 1Mbit
CPU
(SH7709A)
FAX Control
FG CPU Circuit
Relay CI Ditector
Circuit Copier
24Vdc
Moduler
Connector 5Vdc Power
to the External Supply Printer
3.3Vdc I/F
Telephone
Unit
230Vac
R1 R2 I C1 HD6417709A F100
CN1 4.7K 4.7K
5
6
7
8
5
6
7
8
8
7
6
5
R5 R6 TP89 164
3.3K 4.7K TP91 TxD0/SCPT(0)
171
CN2 RxD0/SCPT(0)
169
SCK2/SCPT(5)
4
3
2
1
4
3
2
1
1
2
3
4
2 1 ASMD0- 127
2 1 AUDA TA0 ASMD0/PTG(6)
4 3 135
4 3 AUDA TA1 AUDATA(0)/PTG(0)
6 5 133
6 5 AUDA TA2 AUDATA(1)/PTG(1)
8 7 131
8 7 AUDA TA3 AUDATA(2)/PTG(2)
10 9 130
10 9 AU DSYN C- AUDATA(3)/PTG(3)
12 11 94
12 11 AUDSYNC/PTE(7)
14 13
14 13
16 15
16 15 CPU_TCK
18 17 139
18 17 CPU_TMS TCK/PTF(4)/PINT(12)
20 19 137
20 19 TRST- TMS/PTF(6)/PINT(14)
22 21 136
22 21 CP U_TDI TRST/PTF(7)/PINT(15)
24 23 138
24 23 CPU_TDO R9 0 VO L[A] TDI/PTF(5)/PINT(13)
26 25 VO L[A]
26 25 ASEBR KRK-
28 27 128
28 27 ASEBRKAK/PTG(5)
30 29
30 29
32 31
32 31 R1 0 6.8K TP731
34 33 151
34 33 AU DCK AUDCK/PTH(6)
36 35
R505 36 35 R398 0(3216)(NM) R11 10K
0 +3.3V
L_BT- 206
+3.3V NCS036- 014-DS(NM) TP1129 Q1 KRC105S AN(6)/DA(1)/PTL(6)
SRAMCLR- LE D
R1 3 820 C B TP730 112
+5V R1 4 820 TP1130 JP2 SD00415- 52(NM) R15 10K CASHL/PTJ(4)
+3.3V LED1 LT1P67A 1 2 R561 100 TP1127 204
E
GN D TP1128 AN(5)/PTL(5)
FB 20 K
R1 7 820 +3.3V TP92
MEM2012(NM) 1 2 CPURE S- 193
RESETP
R5 01 R(NM)
R(NM)
10K
GN D A TP1065 7
PW OFF- NMI
C
R500
R504 R2 1 R(NM)
R(NM) X1 TP132 IC3 D18 DA204K R23 10K TP679 194
TP742 GN D R22 R(NM) CA
1 3 1 8 CP U_ CKIO
OE OUT TP1505 XIN VDD R24 10K TP73
2 7 155
XOUT FS0 TP427 TP74 XTAL
4 2 3 6 156
VDD GND R558 330F 4 FS1 MODOUT FB 4 TP96 EXTAL
5 4
LF VSS XTAL2
R(NM)
C242 F0.1u/16 F0.1u/16 R32 10K R33 R(NM) R34 10K TP687 196
+3.3V MD4
R5 02
B F0.1u/16 B470/50 F0.1u/16 F0.1u/16 F0.1u/16 F0.1u/16 F0.1u/16 F0.1u/16 F0.1u/16 F0.1u/16 F0.1u/16
B470/50 F0.1u/16 F0.1u/16 F0.1u/16 F0.1u/16 F0.1u/16 F0.1u/16 F0.1u/16 F0.1u/16 F0.1u/16 208
AVss
198
AVss
148
Vss-PLL2
147
Vss-PLL1
173
Vss
153
Vss
152
Vss
132
Vss
79
Vss
27
Vss
181
VssQ
161
VssQ
109
VssQ
95
VssQ
83
VssQ
69
VssQ
57
VssQ
45
VssQ
33
VssQ
19
VssQ
6
Vss(RTC)
184
TP76 RESETOUT/PTD(2)
143
TP78 IRLS(0)/PTF(0)/PINT(8)
142
TP77 IRLS(1)/PTF(1)/PINT(9)
S_EN 141
R273 R274 +3.3V TP79 IRLS(2)/PTF(2)/PINT(10)
GDMA 140
TP83 IRLS(3)/PTF(3)/PINT(11)
126
GN D GN D GN D GN D TP81 IOIS16/PTG(7)
129
10K 10K R407 100 R4 9 R5 0 TP93 PTG(4)
RGDT- 11
TP82 IRQ3/IRL3/PTH(3)
CI 125
TP85 ADTRG/PTH(5)
GDMAE 110
GN D GN D 10K 10K TP86 CASLH/CASU/PTJ(3)
GC CH 107
C324 TP704 R5 1 33 TP705 RAS2L/PTJ(1)
DQ MUU 92
B1000/50 TP716 R5 2 33 TP703 WE3/DQMUL/ICIOWR/PTK(7)
DQMUL 91
WE2/DQMUL/ICIORD/PTK(6)
R273: Program FLASH
NM(Intel)/10K(Fujituu) GN D
A R274: Standard FLASH
NM(Intel)/10K(Fujituu) R312 R313
10K 10K
GN D
8 7 6 5
1/10
D[0:15]
D[16:31]
A[1:25]
A F100
BR 1 BR 2
13 TP685 4 5 D3 1 TP1067 4 5
D31/PTB(7) +3.3V
14 TP634 3 6 D3 0 TP1074 3 6
D30/PTB(6)
D29/PTB(5)
15 TP638 2 7 D2 9 TP424 2 7 D
16 TP639 1 8 BR 3 D2 8 TP1070 1 8 BR 4
D28/PTB(4) TP632 D2 7 TP1076
17 4 5 4 5
D27/PTB(3) TP633 MNR04 33 D2 6 TP425 MNR04 ( NM)
18 3 6 3 6
D26/PTB(2) TP649 D2 5 TP1072
20 2 7 2 7
D25/PTB(1) TP648 BR 5 D2 4 TP1078 BR 6
22 1 8 1 8
D24/PTB(0) TP650 D2 3 TP423
23 4 5 4 5
D23/PTA(7) TP647 MNR04 33 D2 2 TP1068 MNR04 ( NM)
24 3 6 3 6
D22/PTA(6) TP626 D2 1 TP1075
25 2 7 2 7
D21/PTA(5) TP627 BR 10 D2 0 TP1069 BR11
26 1 8 1 8
D20/PTA(4) TP651 D1 9 TP1071
28 4 5 4 5
D19/PTA(3) TP624 MNR04 33 D1 8 TP1077 MNR04 ( NM)
30 3 6 3 6
D18/PTA(2) TP652 D1 7 TP426
31 2 7 2 7
D17/PTA(1) TP623 BR12 D1 6 TP1073 BR13
32 1 8 1 8
D16/PTA(0) TP653 D1 5 TP1094
34 4 5 4 5
D15 TP625 MNR04 33 D1 4 TP1093 MNR04 ( NM) R7 33
36 3 6 3 6
D14 TP654 D1 3 TP1092
37 2 7 2 7
D13 TP636 BR 14 D1 2 TP1085 BR15 TP415
38 1 8 1 8 CK IO_GA1
D12 TP628 D1 1 TP1088
39 4 5 4 5
D11 TP629 MNR04 33 D1 0 TP1091 MNR04 ( NM) TP737
40 3 6 3 6 FB 1
D10 TP637 D9 TP1084
41 2 7 2 7 MEM2012(NM)
D9 TP630 BR16 D8 TP1087 BR17
42 1 8 1 8 IC2
D8 TP631 D7 TP1090 GN D
43 4 5 4 5 1
D7 TP646 MNR04 33 D6 TP1079 MNR04 ( NM) 1G R8 33
44 3 6 3 6
D6 TP720 D5 TP1083 TP128
46 2 7 2 7 8 12
D5 TP641 BR 18 D4 TP1086 BR19 1A4 1Y4 TP127 TP216
48 1 8 1 8 6 14 CK IO_GA2
D4 TP645 D3 TP1089 1A3 1Y3 TP126
49 4 5 4 5 4 16
D3 TP642 MNR04 33 D2 TP1080 MNR04 ( NM) 1A2 1Y2
50 3 6 3 6 2 18 FB 2
D2 TP643 D1 TP1081 1A1 1Y1
51 2 7 2 7 MEM2012(NM)
D1 TP644 D0 TP1082
52 1 8 1 8 19
D0 BR20 BR21 2G GN D
53 TP107 4 5 MNR04 33 A0 TP125 4 5 MNR04 ( NM) 11 9 TP911 R1 2 33 TP1066
A0 A1 +3.3V 2A1 2Y1
54 TP108 3 6 TP662 3 6 13 7 TP912
A1 TP640 A2 TP661 2A2 2Y2 TP913
55 2 7 2 7 15 5 CK IO_SDRAM
A2 TP721 BR 22 A3 TP660 BR23 R1 6 0 TP686 2A3 2Y3
56 1 8 1 8 CP U_ CKIO 17 3
A3 TP109 A4 TP666 2A4 2Y4
58 4 5 4 5 FB 3
A4 TP111 MNR04 33 A5 TP665 MNR04 ( NM)
60 3 6 3 6 20 +3.3V MEM2012(NM)
A5 TP110 A6 TP664 VCC
61 2 7 2 7
A6 TP112 BR24 A7 TP663 BR25 C1 GN D
62 1 8 1 8
A7 TP706 A8 TP659 F0.1u/16
63 4 5 4 5 10
A8 TP709 MNR04 33 A9 TP658 MNR04 ( NM) GND
64 3 6 3 6
A9 TP708 A10 TP657 GN D TC74LCX244FT C
65 2 7 2 7
A10 TP707 BR 26 A11 TP656 BR27 GN D
66 1 8 1 8
A11 TP113 A12 TP667 R219 47
67 4 5 4 5
A12 TP114 MNR04 33 A13 TP668 MNR04 ( NM)
68 3 6 3 6
A13 TP115 A14 TP669 TP129
70 2 7 2 7
A14 TP116 BR28 A15 TP670 BR29
72 1 8 1 8
A15 TP711 A16 TP655
73 4 5 4 5 FB 13
A16 TP710 MNR04 33 A17 TP722 MNR04 ( NM)
74 3 6 3 6 MEM2012(NM)
A17 TP713 A18 TP736
75 2 7 2 7
A18 TP712 BR 30 A19 TP701 BR31 GN D
76 1 8 1 8
A19 TP120 A20 TP735 BR 32 BR 33 BR 34 BR 35 BR 36
77 4 5 4 5
A20 TP119 MNR04 33 A21 TP733 MNR04 ( NM) +3.3V MNR04 10K MNR04 10K MNR04 10K MNR04 10K MNR04 10K
78 3 6 3 6
A21 TP118 A22 TP734
80 2 7 2 7
8
7
6
5
8
7
6
5
8
7
6
5
6
5
8
7
8
7
6
5
A22 TP117 A23 TP732 R4 0
82 1 8 1 8
A23 TP692 R3 8 33 A24 TP1044
84
A24 TP121 R4 1 33 MNR04 33 A25 TP723 MNR04 ( NM)
86
A25 R42 R(NM) 10K
1
2
3
4
1
2
3
4
1
2
3
4
3
4
1
2
1
2
3
4
162 TP97 TUIKA1
CKIO TP677 WAIT-
123 WA IT-
WAIT TP678 R43 10K R39 R(NM)
122 +3.3V
BREQ TP84 BR37
121
BACK TP102 TP693 RD -
88 4 5 RD -
RD TP101 TP700 WE0-
89 3 6 WE0-
WE0/DQMLL TP100 TP694 WE1-
90 2 7 WE1-
WE1/DQMLU/WE TP99 TP699 RD /WR-
93 1 8 RD/ WR-
RD/WR TP702 R4 4 33 TP695 BS-
87 BS-
BS/PTK(4) MNR04 33 BR 38
96 TP103 4 5 TP698 CS0-
CS0/MCS(0) CS2- CS0-
98 TP104 3 6 TP696
CS2/PTK(0) CS3- CS2-
99 TP105 2 7 TP697
CS3/PTK(1) CS3-
100 TP106 1 8 TP719 CS4-
CS4/PTK(2) CS4-
101 TP714 R4 5 33 TP718 CS5-
CS5/CE1A/PTK(3) CS5-
102 TP715 R4 6 33 MNR04 33 TP717 CS6-
CS6/CE1B CS6-
191 DR EQ[0]-
DREQ0/PTD(4) DRE Q[0]-
192 TP417 DR EQ[1]-
DREQ1/PTD(6) DRA K[0] DRE Q[1]-
189 TP689 R4 7 33
DRAK0/PTD(1) DRA K[0]
190 TP688 R4 8 33 DRA K[1]
DRAK1/PTD(0) DRA K[1]
160 TP87
IRQOUT TP683 IR Q2-
10
IRQ2/IRL2/PTH(2)
9 IR Q1-
IR Q2-
IR Q1-
B
IRQ1/IRL1/PTH(1) TP95 IR Q0-
8 IR Q0-
IRQ0/IRL0/PTH(0)
177 TP409
MCS(7)/PTC(7)/PINT(7) SPMUTE
178 TP1502
MCS(6)/PTC(6)/PINT(6) HNDM UTE-
179 TP1503
MCS(5)/PTC(5)/PINT(5) TP1504
180 MPXA
MCS(4)/PTC4)/PINT(4)
185 EC
MCS(3)/PTC(3)/PINT(3) TP135
186 CML
MCS(2)/PTC(2)/PINT(2) TP137
187
MCS(1)/PTC(1)/PINT(1) TP136
188 S
MCS(0)/PTC(0)/PINT(0)
115 TP727
DACK1/PTD(7) CI ON
114 TP729
DACK0/PTD(5) 150VON-
182
WAKEUP/PTD(3)
116 TP528
CAS2L/PTE(6) TP527
104 TXSEL[A]
CE2B/PTE(5) TP7
103 VOLCNT [B]
CE2A/PTE(4) TP8
117 VOLCNT [A]
CAS2H/PTE(3) TP15
118 VO L[C]
RAS3U/PTE(2) TP14
119 VOL[B]
RAS2U/PTE(1) TP98
120 VOL[A]
TDO/PTE(0)
159 TP739
TCLK/PTH(7) C_BT
12 TP635 100 R408
IRQ4/PTH(4) HS2-
158 TP740
STATUS1/PTJ(7) VRSEL[3]-
157 TP738
STATUS0/PTJ(6) VRSEL[2]-
113 TP728 C325
CASHH/PTJ(5) VRSEL[1]-
B1000/50
207 +3.3V BR 39
AN(7)/DA(0)/PTL(7) MNR04 10K GN D
203 LI UID
AN(4)/PTL(4)
202 HS 1
AN(3)/PTL(3)
8
7
6
5
201 RHS
AN(2)/PTL(2)
200
AN(1)/PTL(1) TP1260
199 EXHS-
AN(0)/PTL(0)
1
2
3
4
4 3 2 1
D[16:31]
D[0:15]
A[1:25]
IC 70
A20 9
A19 A19 DQ15
16
A18 A18 DQ14
17
A17 A17 DQ13
48
A16 A16 DQ12
1
A15 A15 DQ11
2
A14 A14 DQ10
3
A13 A13 DQ9
4
A12 A12 DQ8
5
A11 A11 DQ7
6
A10 A10 DQ6
IC5 IC6 7
A9 A9 DQ5
8
A21 D1 5 A21 D3 1 A8 A8 DQ4
9 45 9 45 18
A20 A19 DQ15 D1 4 A20 A19 DQ15 D3 0 A7 A7 DQ3
16 43 16 43 19
A19 A18 DQ14 D1 3 A19 A18 DQ14 D2 9 A6 A6 DQ2
17 41 17 41 20
A18 A17 DQ13 D1 2 A18 A17 DQ13 D2 8 A5 A5 DQ1
48 39 48 39 21
A17 A16 DQ12 D1 1 A17 A16 DQ12 D2 7 A4 A4 DQ0
1 36 1 36 22
A16 A15 DQ11 D1 0 A16 A15 DQ11 D2 6 A3 A3
2 34 2 34 23
A15 A14 DQ10 D9 A15 A14 DQ10 D2 5 A2 A2 RY/BY
3 32 3 32 24
A14 A13 DQ9 D8 A14 A13 DQ9 D2 4 A1 A1 BYTE
4 30 4 30 25
A13 A12 DQ8 D7 A13 A12 DQ8 D2 3 A0
5 44 5 44
A12 A11 DQ7 D6 A12 A11 DQ7 D2 2 VPP
6 42 6 42 26
A11 A10 DQ6 D5 A11 A10 DQ6 D2 1 ROMNCE- CE VCC
7 40 7 40 12
A10 A9 DQ5 D4 +3.3V A10 A9 DQ5 D2 0 RP
8 38 8 38 28
A9 A8 DQ4 D3 A9 A8 DQ4 D1 9 ROMNOE- OE
18 35 18 35 11
A8 A7 DQ3 D2 A8 A7 DQ3 D1 8 ROMNWE- WE GND
19 33 19 33 14
+3.3V A7 A6 DQ2 D1 R5 6 A7 A6 DQ2 D1 7 ROMNWP- TP272 WP GND
20 31 20 31 10
A6 A5 DQ1 D0 1K A6 A5 DQ1 D1 6 NC
21 29 21 29
A5 A4 DQ0 A5 A4 DQ0
22 22
A4 A3 A4 A3 MBM29LV 160BE90PFTN
23 15 RO MPRY 23 15 RO MPRY
R550 A3 A2 RY/BY TP895 R5 7 A3 A2 RY/BY TP894 R5 8
24 47 +3.3V 24 47 +3.3V
10K A2 A1 BYTE 10K A2 A1 BYTE 10K
25 25
A0 A0
13 13
R549 0 VPP VPP
26 37 26 37
ROMPCE- CE VCC CE VCC C2 8
12 12
C RP RP A33u/10
28 28
ROMPOE- OE C2 7 ROMPOE- OE
11 27 11 27
ROMPWE- WE GND A33u/10 ROMPWE- WE GND
14 46 14 46
ROMPWP- TP892 10 WP GND C2 9 ROMPWP- TP893 10 WP GND C3 1
NC F0.1u/16 C3 0 NC F0.1u/16 C3 2
ROMBANK0
F0.1u/16 F0.1u/16
MBM29LV 160BE90PFTN(NM) GN D MBM29LV 160BE90PFTN(NM) GN D
IC5 IC6
QS51 MBM29LV160 QS51 MBM29LV160
QS52~ MBM29LV800 QS52~ MBM29LV800
ROMBANK1
ROMRP-
ROMOCE-
R553 R(NM)
RES- ROMRP-
R554 33
RAMCE2 +3.3V
+3.3V
+3.3V C3 6
F0.1u/16
+3.3V R6 2
14
4 2
GND RES
PST591IMT
GN D
B GN D
+3.3V +3.
10K
+3.3V
R6 3
10K TP422 TP397 R292 +3.3V
14
R600
9 8 1 2 0 TP1236
MANRES-
C4 2 1SS355
7
UDZ2.0B
TP1238 TP1239 B Q14
GN D TP396 KTA1504
C
IC 11B GN D R6 6 R294
C
KTC3875
E
GN D
GN D
SW2
SW2
TP392
A IC 11D
SW2
R253 0 9 8 TP389
TC74LCX05FT
TP391
IC 11E
R254 0 11 10 TP388
TC74LCX05FT
TP390
IC 11F
R255 0 13 12 TP387
TC74LCX05FT
GN D
4 3
2/10
45 D1 5
DQ15 D1 4
43
DQ14 D1 3
41
DQ13 D1 2
39
DQ12 D1 1
36
DQ11 D1 0
34
DQ10 D9
32
DQ9 D8
30
DQ8 D7
44
DQ7 D6
42
DQ6 D5
40
DQ5 D4
38
DQ4 D3
35
DQ3 D2
33
DQ2 D1
31 RO MNRY
DQ1 D0
29
DQ0 TP268
15 R6 0
RY/BY 1K
47 CN1 0 CN 11
BYTE R59 10K A1 A2
13 13
A2 A0 A3 A0
13 +3.3V 14 14
VPP A3 A1 A4 A1
37 15 15
VCC A4 A2 A5 A2
16 16
C3 3 A5 A3 A6 A3
17 17
A33u/10 A6 A4 A7 A4
27 18 18
GND A7 A5 A8 A5
46 28 28
GND A8 A6 A9 A6
31 31
C3 4 C3 5 A9 A7 A10 A7
32 32
F0.1u/16 F0.1u/16 A10 A8 A11 A8
29 29
V 160BE90PFTN A11 A9 A12 A9
33 33
GN D A12 A10 A13 A10
34 34
A13 A11 A14 A11
36 36
A14 A12 A15 A12
65 65
A15 A13 A16 A13
66 66
A16 A14 A17 A14
67 67
A17 A15 A18 A15 C
68 68
A18 A16 A19 A16
69 69
A19 A17 A20 A17
70 70
A20 A18 A21 A18
71 71
BR130 A19 BR147 A22 MNR04 33 A19
MBANK0 41 41
D0 A20 D0 A20
4 5 2 4 5 2
D1 D0 D1 D0
3 6 3 3 6 3
D2 D1 D2 D1
2 7 4 2 7 4
D3 BR131 D2 D3 BR148 D2
1 8 5 1 8 5
D4 D3 D4 D3
4 5 6 4 5 6
D5 MNR04 33 3 D4 D5 D4
6 7 3 6 7
R1020 D6 D5 D6 D5
BR132 2 7 8
D6
2 7 8
D6
IC9 C 33 D7 1 8 9 D7 BR149 1 8 9
D8 D7 D8 D7
MBANK1 5 6 1 8 21 4 5 21
D9 D8 D9 D8
7 MNR04 33 6 MNR04 33
14
2 22 3 22
IC 72C R613 D1 0 D9 D1 0 D9
3 6 BR133 23 2 7 23
TC74LCX14FT 33 D1 1 D10 D1 1 BR150 D10
9 4 5 24 1 8 24
D1 2 D11 D1 2 D11
8 1 8 25 4 5 25
D1 3 MNR04 33 2 D12 D1 3 MNR04 33 3 D12
OMOCE- 10 7 26 6 26
D1 4 D13 D1 4 D13
D1 5 BR134 3 6 27
D14 D1 5
2 7 27
D14
TC74LCX32FT 4 5 35 BR151 1 8 35
14 7
D0 D15/A-1 D1 6 D15/A-1
1 8 37 4 5 37
IC 72D R614 D1 D16 D1 7 D16
+3.3V 2 7 MNR04 33 38 3 6 MNR04 33 38
33 D2 D17 D1 8 D17
12 3 6 BR135 49 2 7 49
D18 D18
1K
11 D3 4 5 50 D1 9 1 8 BR152 50
D4 D19 D2 0 D19
13 1 8 51 4 5 51
D5 MNR04 33 2 D20 D2 1 MNR04 33 3 D20
7 52 6 52
TC74LCX32FT D6 D21 D2 2 D21
BR136 3 6 53 2 7 53
7
D8 1 8 56 D2 4 4 5 56
D9 D24 D2 5 D24
2 7 MNR04 33 57 3 6 MNR04 33 57
D1 0 D25 D2 6 D25
3 6 BR137 58 2 7 58
O MORY D1 1 D26 D2 7 BR154 D26
4 5 60 1 8 60
D1 2 D27 D2 8 D27
1 8 59 4 5 59
D1 3 MNR04 33 2 D28 D2 9 MNR04 33 3 D28
+3.3V 7 62 6 62
D1 4 D29 D3 0 D29
RES- 3 6 63 2 7 63
D30 D30
10K
10K
10K
10K
D1 5 4 5 64 D3 1 1 8 64
D31 D31
19 ROMRP- 19
8
7
6
5
R227
R228
R229
40 R551 33 40
1
2
3
4
ROMOWP- 46 46
WP ROMPWP- WP
ROMOWE- 47 47
WE ROMPWE- WE
ROMOCD0 11 11
NC NC
ROMOCD1 10 10
VCC VCC
30 30
GND GND
R600
+3.3V 61 +3.3V 61
VCC VCC
ROMOCID0 1 1
GND GND
IC11C 20 20
C3 8 GND C406 GND
OMOCID1 6 5 39 39
A33u/10 GND A33u/10 GND
72 72
TC74LCX05FT NC NC
C3 9 C4 0 C407 C408
F0.1u/16 F0.1u/16 F0.1u/16 F0.1u/16
RAMCE2
3
2
1
GN D GN D
SW2
RF-H062T D-1130
4
5
6
GN D
2 1
D[16:31]
D[0:15]
A[1:25]
IC 13
A13 19 49 D1 5 A13
A12 A11 I/O15 D1 4 A12
20 48
A11 A10 I/O14 D1 3 A11
32 46
A10 A9 I/O13 D1 2 A10
31 45
B A9 30
A8 I/O12
43 D1 1 A9
A8 A7 I/O11 D1 0 A8
29 42
A7 A6 I/O10 D9 A7
28 40
A6 A5 I/O9 D8 A6
27 39
A5 A4 I/O8 D7 A5
24 12
A4 A3 I/O7 D6 A4
23 11
A3 A2 I/O6 D5 A3
22 9
A2 A1 I/O5 D4 A2
21 8
A0 I/O4 D3
6
I/O3 D2
5
I/O2 D1
3
I/O1 D0
CKIO_SDRA M 35 2 CKIO_SDRA M
CLK I/O0
CK E 34 CKE
CKE
CS3- 18 1 CS3-
CS VCC +3.3V
RAS3L- 17 7 RAS3L-
RAS VCC
CASL- 16 13 CASL-
CAS VCC
RD /WR- 15 25 RD/ WR-
WE VCC
WE0- 14 38 DQMUL
LDQM VCC
RAMCE- WE1- 36 44 DQ MUU
UDQM VCC C4 6
RAMOE- A10u/16
IC 71 TP891 33 TP889
RAMWE- NC
A18 9 TP890 37 4 TP888
RAMUB- NC/A17 NC GND
A17 10 29 D1 5 10 C4 4
RAMLB- A16 I/O7 GND
A16 7 28 D1 4 26 F0.1u/16 C4 5
A15 A15 I/O6 D1 3 GND F0.1u/16
11 27 41
A14 A14 I/O5 D1 2 GND GN D
RAMCE2 4 26 47
A13 A13 I/O4 D1 1 GND
12 25 50
A12 A12 I/O3 D1 0 GND
1 23
R287 A11 A11 I/O2 D9
31 22
R(NM) A10 A10 I/O1 D8 W981616BH
2 21
A9 A9 I/O0
3
A8 A8 +3.3V
13
A7 A7
14
GN D A6 A6
15
A5 A5
16
A4 A4
17
A3 A3 VBT3.3
18
+3.3V A2 A2 D2 5
19
A1 A1 1SS355(NM)
20
A0
8
VCC C5 0
14
30
IC 72A R530 TP1114 CE1 C5 2
6
33 CE2 F0.1u/16 A10u/16
1 32
C241 OE
3 5 24
F0.1u/16 WE VSS D2 4 ZD 3
2
1SS355(NM) UDZ2.0B
TC74LCX32FT IS62W V2568B LL-70
7
GN D TP1234
C252 R290
C150/50 1K
GN D
R288
GN D TP1233 360
C
IC 73 B Q11
A18 9 KTC3875
A17 NC/A17 D7
10 29
E
A16 A16 I/O7 D6 C417 R289
7 28
A15 A15 I/O6 D5 F1u/10(1608)(NM) 560
11 27
A14 A14 I/O5 D4
4 26
A13 A13 I/O4 D3
12 25
A12 A12 I/O3 D2
1 23
A11 A11 I/O2 D1
31 22
A10 A10 I/O1 D0
2 21
A9 A9 I/O0
3
A8 A8 GN D
13
A7 A7
14
A6 A6
15
A5 A5
16
A4 A4
17
A3 A3
18
A2 A2
19
A1 A1
20
A0
8
VCC C5 1
14
30
IC 72B R531 TP1115 CE1
6
33 CE2 F0.1u/16
4 32
OE
6 5 24
WE VSS
5
A C150/50
GN D
3/10
IC 14
A13 19 49 D3 1
A12 A11 I/O15 D3 0
20 48
A11 A10 I/O14 D2 9
32 46
A10 A9 I/O13 D2 8
31 45
A9 30
A8 I/O12
43 D2 7 B
A8 A7 I/O11 D2 6
29 42
A7 A6 I/O10 D2 5
28 40
A6 A5 I/O9 D2 4
27 39
A5 A4 I/O8 D2 3
24 12
A4 A3 I/O7 D2 2
23 11
A3 A2 I/O6 D2 1
22 9
A2 A1 I/O5 D2 0
21 8
A0 I/O4 D1 9
6
I/O3 D1 8
5
I/O2 D1 7
3
I/O1 D1 6
AM 35 2
CLK I/O0
KE 34
CKE
S3- 18 1
CS VCC +3.3V
3L- 17 7
RAS VCC
L- 16 13
CAS VCC
WR- 15 25
WE VCC
MUL 14 38
LDQM VCC
MUU 36 44
UDQM VCC C4 9
TP889 33 A10u/16
TP888 NC
37 4
NC GND C4 7
10
GND F0.1u/16 C4 8
26
GND F0.1u/16
41
GND GN D
47
GND
50
GND
W981616BH
+3.3V +5V
R555 R556
0 IC 93 0
C5 3 C5 5 2 1
A10u/16 A10u/16 VCC OUT
2.0B TP1137
R1061 +3.3V 4 3
1234 0 TP1235 GND NC
R290 GN D GN D PST3426
1K
Q12 VBT3.3 GN D
MMBTA56
D1 0 L_BT-
D2 6
1SS355(NM)
Q11 +3.3V
KTC3875 RB751V-40(NM) +5V +5V
JP 4
D1 4 D3 SD00415- 52(NM)
R1058 RLS-73(NM) 1SS355
20K 1 2 R7 0
D23 1SS355(NM) TP1135 R(NM) R507
8
82K R7 6 R(NM)
TP1007 1.6K R(NM) C5 8
R1057 C(NM)
0 R7 8
TP1008 1.6K
GN D
1
BT1 GN D
CR2477- H01
2
TP1009
TP1136 6
- A
7 TP378
R8 0 5
+
IC 16B
0 KIA393F (NM)
GN D
GN D
Q2
DTC363EKA T146
C_BT B C
C_BT
E
GN D
R387 0(3216)
+5VS
C321 C322
F0.1u/16 A33u/10
CN4
D
TX24-60R-12ST-H1
GN D
1 R388 0(3216)
+24V +24V
31
+24V R389 0(3216) C243 C6 3 C6 4
2
+24V F0.01u/50 F0.01u/50 A10u/35
32
+24V
3 R390 0(3216)
+5V +5V
33
+5V R391 0(3216) C6 5 C6 6
4
+5V F0.1u/16 A33u/10
34
+5V / +5VS
+3.3V
5 GN D TP897
+3.3V +3.3V
35
+3.3V
10K
10K
10K
10K
10K
10K
6 C7 0 C7 1
+3.3V F0.1u/16 A33u/10
36
+3.3V
R233
R234
R235
R236
R237
R238
IC
7 FRESET- GN D TP1231 11
RESET- R284 100
37 EXTRS
NC / EXTRS C7 2 TC
8
PWOFF- B1000/50
38 FAXWU-
NC / FAXWU-
9
PRLINE- GN D
39
SCLINE- IC
10
HSYNC- TP1230
40 13
READY- R285 100
K K C7 3 TC
+5VS +5VS
11 B1000/50
SG
41 AK AK +3.3V
SG GN D
12
SG
42 A A
SG
10K
10K
10K
10K
10K
D21 DA204K D22 DA204K IC 22
13 GN D GN D 2 18
FAXPAGE- 1A1 1Y1
C
R241
R242
R243
R244
R245
43 R1059 100 TP748 4 16
FAXDET- R8 3 0 R8 4 R(NM) 1A2 1Y2
14 6 14
FAXCMD 1A3 1Y3
44 8 12
FAXSTS R1060 100 1A4 1Y4
15 11 9
FAXCRDY- BR47 BR48 BR49 BR50 2A1 2Y1
45 13 7
FAXSRDY- MNR04 10K MNR04 10K MNR04 10K MNR04 10K 2A2 2Y2
15 5
2A3 2Y3
+3.3V 17 3
2A4 2Y4
5
6
7
8
5
6
7
8
5
6
7
8
5
6
7
8
16 C418 C419
SG B1000/50 B1000/50
46 1 20
SG R8 5 1G VCC
19
10K 2G
4
3
2
1
4
3
2
1
4
3
2
1
4
3
2
1
25 IC 26
SG GDATA[0:15]
55 18 2
SG 1Y1 1A1
16 4
1Y2 1A2
14 6
1Y3 1A3
26 12 8
FAXPRD- 1Y4 1A4
56 9 11
FAXREQ1P- 2Y1 2A1
27 7 13
FAXACK1P- 2Y2 2A2
57 5 15
FAXCS1P- TP160 2Y3 2A3
3 17
2Y4 2A4
28 +3.3V 20 1
SG VCC 1G
19
B C8 5 2G
58 F0.1u/16 10
FAXREQ0P- GND
29
FAXACK0P- TC74LCX244FT
59
FAXCS0P- GN D GN
30
SG
60
SG
TP1055
GN D
HOLE
HOLE
HOLE
HOLE
HOLE
HOLE
HOLE
GN D
H1
H2
H3
H4
H5
H6
H7
CN1 2
B3B-PH-K-S
1
A 1
2
2
3
3
8 7 6 5
4/10
D5 1SS355(NM) D
IC19 KIA78M12P(NM)
+24V R8 1 0 IN OUT +12V
IN OUT
GND
R260 0
C6 7
C6 8 C6 9 A47u/16(NM)
GND
F0.01u/50 C244 F0.1u/16
F0.01u/50
GN D
IC 9E
11 10 TP395
FRESET
R615 33
TC74LCX14FT
IC9 F IC 20A14
13 12 TP386 1 2 PWOFF-
7 R616 33
TC74LCX14FT TC74LCX04FT
R240 0
2 +3.3V
18 PR LINE-
1Y1
1Y2
16 SC LINE-
MEM2012(NM) C
14 FB 15
1Y3 READ Y-
12 FAXSTS
1Y4
9 FAXCRDY -
2Y1 TP745
7 FAXACK1P- GN D
2Y2 TP746 D7 1SS355(NM)
5 FAXCS1P-
2Y3 TP1131
3 FAXREQ0P-
2Y4
20 TP1103 TP1049
VCC +3.3V
IC23 LM1117MPX-3.3(NM)
C7 7 +5V R8 6 0 3 2 R246 R(NM) MDM3.3V
F0.1u/16 IN OUT1
10
GND
GND R262 0 4
LCX244FT OUT2 C8 0 C7 8
GN D C7 9 F0.1u/16 A33u/10
1
F0.1u/16
IC 9B IC 20B14 GN D
4 TP384 3 4 HS YNC-
7 R617 33
+3.3V TC74LCX04FT
TC74LCX14FT
+3.3V
10K
10K
R8 7
10K
R247
R248
2 FAXPAGE-
1A1
4 FAXCMD
1A2
6 FAXSR DY-
1A3
8 FAXPRD-
1A4 TP161
11 FAXREQ1P-
2A1
13 FAXACK0P-
2A2
15 FAXCS0P-
2A3
17
2A4
1
1G
19
2G B
LCX244FT
GN D
D8 1SS355
TP1124
IC25 LM1117MPX-1.8
+3.3V R8 8 0 3 2 TP410 +1.8V
IN OUT1
GND
R263 0 4
OUT2 C8 2
C8 3 C8 4 A33u/10
1
F0.1u/16 F0.1u/16
GN D
4 3 2 1
R301 0 C8 6 C8 7 C8 8 C8 9 C9 0 C9 1
F0.1u/16 F0.1u/16 F0.1u/16 F0.1u/16 F0.1u/16 F0.1u/1
R271 0
R9 1 0 GN D GN D GN D GN D GN D GN
CD1A[0:3]
CD1 RE QD0
CD1 RE QC0
TP1057 R1028 33(1608) CD1AC KD0-
TP1058 R1027 33(1608) CD1AC KC0-
TP1098
+3.3V 3.3VGA1 CD1 D[ 0:15]
33(1608) CD 1WR-
33(1608) CD1 CS -
CD1 UBE-
33(1608) C D1RD-
CD1 D1 5
CD1 D1 4
CD1 D1 3
CD1 D1 2
CD1 D1 1
CD1 D1 0
CD 1D5
CD 1D4
CD 1D3
CD 1D2
CD 1D1
CD 1D9
CD 1D8
CD 1D7
CD 1D6
CD 1D0
4 FB 7
MEM2012(NM)
C328
BR156 MNR04 33
BR157 MNR04 33
BR158 MNR04 33
BR159 MNR04 33
A33u/10
GN D
8
7
6
5
8
7
6
5
8
7
6
5
8
7
6
5
TP374 R1005 33
TP1059 R1026
TP1060 R1025
TP364 R1024
GN D
1
2
3
4
1
2
3
4
1
2
3
4
1
2
3
4
TP962
TP961
TP960
TP959
TP956
TP957
TP958
TP955
TP954
TP953
TP948
TP951
TP952
TP947
TP950
TP949
TP363
TP375
304
303
302
301
300
299
298
297
296
295
294
293
292
291
290
289
288
287
286
285
284
283
282
281
280
279
278
277
276
275
274
273
272
271
270
269
268
VDD- 304
VDD- 303
GND- 298
VDD- 297
GND- 292
VDD- 291
GND- 286
GND- 285
GND- 280
VDD- 279
GND- 274
VDD- 273
GND 268
CDD[1 5]
CDD[1 4]
CDD[1 3]
CDD[1 2]
CDD[1 1]
CDD[1 0]
CDD[9 ]
CDD[8 ]
CDD[7 ]
CDD[6 ]
CDD[5 ]
CDD[4 ]
CDD[3 ]
CDD[2 ]
CDD[1 ]
CDD[0 ]
CDA CKD_N
CDA CKC_N
CDRE QD
CDRE QC
CDUB E_N
CDWR_ N
CDRD_ N
CDCS _N
1
GND-1
2
TP613 GND-2
3
BR 51 TP616 VORES_N
4
MNR04 4.7K TP617 VOSD
5
GN D TP614 VOSI
6
5
6
7
8
3.3VGA1 TP615 VOST_N
7
TP612 VOCH_N
8
TP611 VOBUSY_N
9
TP297 VONAR
10
4
3
2
1
TP300 NC
11
TP299 TCK
12
TP298 TDI
13
TP301 TRST
14
RTCDT TP1099 TDO IC 27
15
RTCCK TP305 RTCDT
16 uPD65948G L-114NMU
RTCCE TP306 RTCCK
17
RT CIO TP307 RTCCE
18
3 3.3VGA1 RTCIO
19
C100 VDD-19
20
F0.1u/16 TP303 GND-20
21
TP304 RTC245DIR
22
BZ TP513 RTC245OE_N
23
GN D BT TP1 BZ
24
MDMRES- TP596 BT
25
TP580 MDMRES_N
26
TP581 MDMCS_N
27
TP582 MDMRD_N
28
MDMIRQ TP51 MDMWR_N
29
R9 3 4.7K TP302 MDMIRQ
30
3.3VGA1 TMS
31
TP586 GND-31
32
TP587 MDMA[0]
33
TP585 MDMA[1]
34
GN D TP584 MDMA[2]
35
TP583 MDMA[3]
36
MDMA[4]
37
3.3VGA1 VDD-37
38
C104 VDD-38
39
F0.1u/16 GND-39
40
TP594 GND-40
41
TP595 MDMD[0]
42
GN D TP593 MDMD[1]
43
TP592 MDMD[2]
44
3.3VGA1 MDMD[3]
45
C106 VDD-45
46
F0.1u/16 TP589 GND-46
47
TP588 MDMD[4]
48
TP590 MDMD[5]
49
GN D TP591 MDMD[6]
50
3.3VGA1 MDMD[7]
51
C107 VDD-51
52
F0.1u/16 G1REQ- R1022 33(1608) TP878 GND-52
53
G1ACK- TP872 G1REQ_N
54
G2REQ- TP870 G1ACK_N
55
GN D G2ACK- R1023 33(1608) TP869 G2REQ_N
56
3.3VGA1 BR169 G2ACK_N
57
C108 MNR04 33 VDD-57
58
F0.1u/16 G1 D0 TP874 GND-58
1 8 59
2 G1D[0:7] G1 D1 2 7 TP871 60
G1D[0]
G1 D2 G1D[1]
3 6 BR170 TP877 61
GN D G1 D3 G1D[2]
4 5MNR04 33 TP875 62
G1 D4 TP873 G1D[3]
1 8 63
G1 D5 TP876 G1D[4]
2 7 64
G1 D6 TP868 G1D[5]
3 6 65
G1 D7 TP867 G1D[6]
4 5 66
G2 D0 TP862 G1D[7]
67
G2 D1 TP861 G2D[0]
68
G2 D2 TP863 G2D[1]
69
G2 D3 TP860 G2D[2]
70
G2 D4 TP864 G2D[3]
71
G2 D5 TP865 G2D[4]
72
G2 D6 TP859 G2D[5]
73
G2 D7 TP866 G2D[6]
G2D[0:7] 74
G2D[7]
75
GND-75
76
RW (RD/WR-)
GND-76
DRE Q[0]_N
DRE Q[1]_N
DRA K[0]_N
DRA K[1]_N
VDD 113
WAIT_N
GND-95
GND-96
GN D
VDD- 77
VDD- 78
WE0_N
WE1_N
CS0_N
CS4_N
CS6_N
RD_ N
BS_N
A[10]
A[11]
A[12]
A[13]
A[14]
A[15]
A[16]
A[20]
A[21]
A[22]
A[1]
A[2]
A[3]
A[4]
A[5]
A[6]
A[7]
A[8]
A[9]
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
R2 12 TP916 112
113
A10
A11
A12
A13
A14
A15
A16
A1
A2
A3
A4
A5
A6
A7
A8
A9
33 TP416
TP691
TP690
A20
A21
A22
33
33
A[1:25]
RD/ WR-
CS 0-
CS 4-
CS 6-
WE0 -
WE1 -
WAIT-
DRAK[ 0]
DRAK[ 1]
BS-
RD-
R1006
R1007
3.3VGA1
1 C110
F0.1u/16
DRE Q[0]-
DRE Q[1]-
GN D GN D
3.3VGA1
C115
F0.1u/16
GN D
A B C
5/10
VGA1 3.3VGA1 3.3VGA1 3.3VGA1 3.3VGA1 3.3VGA1 3.3VGA1 3.3VGA1
C9 1 C9 2 C9 3 C9 4 C9 5 C9 6 C9 7
6 F0.1u/16 F0.1u/16 B0.1u/25(1608)B0.1u/25( 1608)B0.1u/25(1608)B0.1u/25(1608)B0.1u/25(1608)
ND GN D GN D GN D GN D GN D GN D GN D
M1D[0:15]
33(1608) CD 1WR-
33(1608) CD1 CS -
CD1 UBE-
33(1608) C D1RD-
CD1 A3
CD1 A2
CD1 A1
CD1 A0
M1D15
M1D14
M1D13
M1D11
4
M1 D9
M1 D8
M1D12
M1D10
M1 D7
M1 D6
M1 D5
M1 D4
M1 D3
M1 D2
M1 D1
M1 D0
BR168 MNR04 33
BR163 MNR04 33
BR162 MNR04 33
BR161 MNR04 33
BR160 MNR04 33
CD 1IRQ-
CD1 RES-
CD1 CLK
8
7
6
5
4
3
2
1
4
3
2
1
4
3
2
1
4
3
2
1
TP374 R1005 33
TP1059 R1026
TP1060 R1025
TP364 R1024
1
2
3
4
5
6
7
8
5
6
7
8
5
6
7
8
5
6
7
8
TP361
TP360
TP359
TP372
TP1062
TP428
TP1061
TP371
TP1006
TP1005
TP1004
TP1003
TP996
TP1000
TP1001
TP1002
TP999
TP998
TP997
TP994
TP995
TP970
TP971
TP993
274
273
272
271
270
269
268
267
266
265
264
263
262
261
260
259
258
257
256
255
254
253
252
251
250
249
248
247
246
245
244
243
242
241
240
239
238
237
236
235
234
233
232
231
230
229
GND- 274
VDD- 273
GND- 268
GND- 267
VDD- 266
VDD- 265
GND- 260
VDD- 259
GND- 254
VDD- 253
GND- 248
GND- 247
GND- 242
VDD- 241
GND- 236
VDD- 235
VDD- 230
VDD- 229
CDCL K
CDA [3]
CDA [2]
CDA [1]
CDA [0]
MD[9 ]
MD[8 ]
MD[7 ]
MD[6 ]
MD[5 ]
MD[4 ]
MD[3 ]
MD[2 ]
MD[1 ]
MD[0 ]
CDRE QC
CDUB E_N
CDWR_ N
CDRD_ N
CDCS _N
CDRE S_N
MD[15]
MD[14]
MD[13]
MD[12]
MD[11]
MD[10]
TRES_N
CDIRQ
228 BR175
GND-228 MNR04 33
227
GND-227
226 TP981 1 8 M1A15 M1A[0:15]
MA[15]
225 TP984 2 7 M1A14
MA[14]
224 TP982 3 6 M1A13
MA[13]
223 TP985 4 5 M1A12
MA[12] BR174 B0.1u/25( 1608)
222
GND-222 MNR04 33 C9 8
221
VDD-221
220 TP983 1 8 M1A11 3.3VGA1
GN D
MA[11]
219 TP978 2 7 M1A10
MA[10]
218 TP979 3 6 M1A9
MA[9]
217 TP977 4 5 M1A8
MA[8] BR173 B0.1u/25( 1608)
216
GND-216 MNR04 33 C9 9
215
VDD-215
214 TP980 1 8 M1A7 3.3VGA1
GN D
MA[7]
8G L-114NMU 213 TP974 2 7 M1A6
MA[6]
212 TP976 3 6 M1A5
MA[5]
211 TP973 4 5 M1A4
MA[4] BR172 B0.1u/25( 1608) 3
210
GND-210 MNR04 33 C101
209
VDD-209
208 TP975 1 8 M1A3 3.3VGA1
GN D
MA[3]
207 TP988 2 7 M1A2
MA[2]
206 TP987 3 6 M1A1
MA[1]
205 TP986 4 5 M1A0
MA[0] B0.1u/25( 1608)
204
GND-204 C102
203
VDD-203 TP992 R1052 33(1608) M1UB- GN D
202 3.3VGA1
MUB_N TP989 R1053 33(1608) M1LB-
201
MLB_N TP972 R1054 33(1608) M1WE-
200
MWE_N TP991 R1055 33(1608) M1OE-
199
MOE_N TP990 R1056 33(1608) M1CE- B0.1u/25(1608)
198
MCE_N C103
197
GND-197 GN D
196 3.3VGA1
VDD-196 R509 100 RES-
195
RES_N R1011 33 CPURES-
194
CPURES_N TP940 R1013 33 MANRES-
193
MANRES_N C401
192
GND-192 F0.1u/16 C100/50
191
GND-191 BR138 C105
190
VDD-190 MNR04 62 GN D
189 3.3VGA1
VDD-189 TP917 RAMUB- GN D
188 1 8
RAMUB_N TP918 RAMLB-
187 2 7
RAMLB_N TP919 RAMWE-
186 3 6
RAMWE_N TP921 R529 RAMOE-
185 4 5
RAMOE_N TP920 33 RAMCE-
184
RAMCE_N
183
GND-183 TP932
182
BFDIR TP930
181
BFOE_N
180
GND-180 TP931 RO MOCID1
179
ROMOCID[1] TP933 RO MOCID0
178
ROMOCID[0] TP929 ROMOCD1
177
ROMOCD[1] TP928 ROMOCD0
176
ROMOCD[0] TP934
175
ROMBNK[2] R1012 33 ROMBANK1
174
ROMBNK[1] R1001 33 ROMBANK0 F0.1u/16
173
ROMBNK[0] BR139 C109
172
GND-172 MNR04 33 GN D
171 3.3VGA1
VDD-171 TP925 RO MORY
170 1 8
ROMRY
169 TP924 2 7 ROMOWP- 2
ROMOWP_N TP923 ROMOWE-
168 3 6
ROMOWE_N TP922 BR140 ROMOOE-
167 4 5
ROMOOE_N TP935 MNR04 33 ROMOCE-
166
ROMOCE_N
165 1 8
GND-165 TP938 RO MNRY
164 2 7
ROMNRY TP937 BR141 3 ROMNWP-
163 6
ROMNWP_N TP942 MNR04 33 4 ROMNWE-
162 5
ROMNWE_N TP936 ROMNOE-
161 1 8
ROMNOE_N TP941 ROMNCE -
160 2 7
ROMNCE_N TP945 BR142 RO MPRY
159 3 6
ROMPRY TP939
158 4 5 MNR04 33 ROMPWP-
ROMWP_N TP944 ROMPWE-
157 1 8
ROMPWE_N TP946 ROMPOE-
156 2 7
ROMPOE_N TP943 ROMPCE-
155 3 6
ROMPCE_N
154 4 5
GND-154
153
GND-153
DRE Q[0]_N
DRE Q[1]_N
DRA K[0]_N
DRA K[1]_N
BSSEL[ 0]
BSSEL[ 1]
IRQ [0]_N
IRQ [1]_N
GND-115
GND-116
GND-123
GND-127
GND-130
GND-133
GND-134
GND-138
GND-141
GND-145
GND-148
VDD- 113
VDD- 114
VDD- 126
VDD- 137
VDD- 144
VDD- 151
VDD- 152
WAIT_N
MODE3
WE0_N
WE1_N
GN D
D[10]
D[11]
D[12]
D[13]
D[14]
D[15]
CLK
D[0]
D[1]
D[2]
D[3]
D[4]
D[5]
D[6]
D[7]
D[8]
D[9]
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
151
152
R2 12 TP916
D1 0
D1 1
D1 2
D1 3
D1 4
D1 5
33 TP416
TP691
TP690
TP915
33 TP684
D0
D1
D2
D3
D4
D5
D6
D7
D8
D9
33
33
33
33
D[0:15]
WE1 -
WAIT-
CK IO_GA1
DRAK[ 0]
DRAK[ 1]
R1006
R1007
R1008
R1009
R1010
MD3
R94 R(NM)
3.3VGA1
GN D GN D GN D GN D
R95 R(NM)
3VGA1
C115 R9 6 0
F0.1u/16
R9 7 0
GN D
GN D
C D E
BR 57 BR 58 BR59 BR 60
MNR04 ( NM) MNR04 ( NM) MNR04 ( NM) MNR04 ( NM)
D +3.3V
8
7
6
5
8
7
6
5
8
7
6
5
8
7
6
5
CD1A[0:3] IC 28
1
2
3
4
1
2
3
4
1
2
3
4
1
2
3
4
CD 1A3 42 75 TP310 IA 15
CD 1A2 A3 IA15 TP318 IA 14
43 76
CD 1A1 A2 IA14 TP313 IA 13
CD1 D[ 0:15] 44 77
CD 1A0 A1 IA13 TP314 IA 12
CD2D[0:15] 45 78
BR114 MNR04 0 A0 IA12 TP317 IA 11
79
CD 2D15 CD 1D15 IA11 TP312 IA 10
4 5 12 82
CD 2D14 CD 1D14 D15 IA10 TP315 IA9
3 6 13 83
CD 2D13 CD 1D13 D14 IA9 TP316 IA8
2 7 14 84
CD 2D12 BR115 MNR04 0 CD 1D12 D13 IA8 TP323 IA7
1 8 15 85
CD 2D11 CD 1D11 D12 IA7 TP322 IA6
4 5 16 86
CD 2D10 CD 1D10 D11 IA6 TP321 IA5
3 6 17 87
CD 2D9 CD 1D9 D10 IA5 TP326 IA4
2 7 18 88
CD 2D8 BR116 MNR04 0 1 CD 1D8 D9 IA4 TP325 IA3
8 19 89
CD 2D7 CD 1D7 D8 IA3 TP324 IA2
4 5 20 90
CD 2D6 CD 1D6 D7 IA2 TP328 IA1
3 6 21 93
CD 2D5 CD 1D5 D6 IA1 TP329 IA0
2 7 22 94
CD 2D4 BR117 MNR04 0 CD 1D4 D5 IA0
1 8 23
CD 2D3 CD 1D3 D4 TP331 ID 15
4 5 26 95
CD 2D2 CD 1D2 D3 ID15 TP330 ID 14
3 6 27 96
CD 2D1 CD 1D1 D2 ID14 TP332 ID 13
2 7 28 97
CD 2D0 CD 1D0 D1 ID13 TP333 ID 12
1 8 29 98
D0 ID12 TP334 ID 11
99
R602 62 ID11 TP336 ID 10
CD1 RD- 1 CD1 UBE- 31 100
UBE- ID10 TP335 ID 9
3 7 101
RD- ID9 TP337 ID 8
CD2 RD- 2 8 104
IC 82A WR- ID8 TP338 ID 7
CD1 CS- 30 105
TC74LCX08FT CS- ID7 TP340 ID 6
2 106
HEX- ID6 TP339 ID 5
107
ID5 TP341 ID 4
CD1 RES- 1 108
R604 62 R306 R(NM) R103 1K RESET- ID4 TP342 ID 3
CD 1WR- 4 109
CD2 IRQ0 ID3 TP344 ID 2
6 3 110
CD1 IRQ- R307 0 TP968 INTR0 ID2 TP343 ID 1
CD 2WR- 5 4 111
IC 82B CD2 IRQ1 TP969 INTR1 ID1 TP345 ID 0
5 112
TC74LCX08FT R308 1K INTR2 ID0
32 46 TP358
CD1 REQC0 REQC0 IHREQ
C +3.3V
R109 C D2ACKC-
CD2 REQC
TP373 33
REQC1 IHACK
47 TP963 R302 10K
10K 34
CD1 REQD0 REQD0
R112 C D2ACKD- TP362 35 56 TP1056
10K CD2 REQD REQD1 IREADY R303 10K
38 59 TP349
R527 CD1ACKC0- C D2ACKC- ACKC0- IMUE- TP351
CD2ACKC- 39 60
0 TP966 40 ACKC1- IMLE- TP365 R1029 33(16
50
R528 CD1ACKD0- R111 0 C D2ACKD- ACKD0- IMR- TP357 R1030 33(16
CD2ACKD- 41 51
R(NM) X3 R113 R(NM) R114 R(NM) TP967 ACKD1- IMW-
CD1 CLK +3.3V
1 3 R115 0 TP376 6 62 TP352
+3.3V OE OUT TP418 FB 8 TP377 TP366 CLKIN EXA0 TP353
10 61
MEM2012(NM) CLKOUT EXA1
FB 23 4 2 CLK16M
VDD GND TP964 R304 10K
MEM2012(NM) 125 49
OSC515101J IS-16.0000M Hz-3.3TR TEST3 DREQ0 TP965 R305 10K
126 48
GN D GN D TEST2 DREQ1
127
TEST1 TP354
128 64
C245 F0.1u/16 +3.3V GN D TEST0 DACK0- TP355
63
GN D DACK1-
9
VDD1 TP350
24 58
VDD2 DCMP0- TP356
36 57
VDD3 DCMP1-
54
VDD4 TP370
65 52
VDD5 IOR- TP348
80 53
VDD6 IOW-
91
VDD7
102 122
VDD8 PLLOFF
113
VDD9 TP308
123 67
VDD10 NC67 TP320
68
C129 C130 C131 C132 C133 C134 C135 C136 C137 C138 NC68 TP327
69
NC69 TP309
70
F0.1u/16 F0.1u/16 F0.1u/16 F0.1u/16 F0.1u/16 F0.1u/16 F0.1u/16 F0.1u/16 F0.1u/16 F0.1u/16 NC70 TP319
71
NC71 TP311
124 72
VSS10 NC72
114
VSS9
103 117
VSS8 SCANEN
92 116
VSS7 MINTEST
81 74
VSS6 MINTIN
66 73
VSS5 MINTC
55
VSS4 R122 2K
37 120
VSS3 PCO TP347
25
VSS2 GN D
11
B +3.3V VSS1
115
VREF5 TP346 R123 10
119
GN D VCOI
118
AVDD C139
C329 C141
A33u/10 B2200/50
F0.1u/16 121
AVSS
GN D
GN D MN86065
4 3
6/10
ID [0: 15]
D
IC 77
IA 15 IA[0:15] IA 15 1 38 ID 15
IA 14 IA 14 A15 I/O15 ID 14
2 37
IA 13 IA 13 A14 I/O14 ID 13
3 36
IA 12 IA 12 A13 I/O13 ID 12
4 35
IA 11 IA 11 A12 I/O12 ID 11
5 32
IA 10 IA 10 A11 I/O11 ID 10
18 31
IA9 IA9 A10 I/O10 ID 9
19 30
IA8 IA8 A9 I/O9 ID 8
20 29
IA7 IA7 A8 I/O8 ID 7
21 16
IA6 IA6 A7 I/O7 ID 6
24 15
IA5 IA5 A6 I/O6 ID 5
25 14
IA4 IA4 A5 I/O5 ID 4
26 13
IA3 IA3 A4 I/O4 ID 3
27 10
IA2 IA2 A3 I/O3 ID 2
42 9
IA1 IA1 A2 I/O2 ID 1
43 8
IA0 BR 61 +3.3V IA0 A1 I/O1 ID 0
44 7
MNR04 10K A0 I/O0
ID 15 4 5 6 22
ID 14 CE NC
3 6 17 23
ID 13 WE NC +3.3V
2 7 41 28
ID 12 OE NC
1 8 BR62 MNR04 10K 39 C260
ID 11 LB F0.1u/16
4 5 40 11
ID 10 UB VCC
3 6 33
ID 9 BR 63 VCC C258
2 7
ID 8 MNR04 10K1 8 12 A33u/10
ID 7 VSS
4 5 34
ID 6 VSS C259
3 6
ID 5 2 7 F0.1u/16
ID 4 1 8 BR64 MNR04 10K GN D
ID 3 4 5 IS61LV6416-12T
ID 2 3 6 GN D
ID 1 2 7
ID 0 1 8 +3.3V
R302 10K
+3.3V
C
R1062 R1063 R1064 R1065
10K 10K 10K 10K
R303 10K
+3.3V
1029 33(1608)
1030 33(1608)
R304 10K
R305 10K
M1D[0:15]
GN D
M1A[0:15]
IC 32 BR179
MNR04 33
M1A15 1 38 1 8 M1D15
M1A14 A15 I/O15 M1D14
2 37 2 7
M1A13 A14 I/O14 BR178 3 M1D13
3 36 6
M1A12 A13 I/O13 MNR04 33 4 M1D12
4 35 5
M1A11 A12 I/O12 M1D11
5 32 1 8
M1A10 A11 I/O11 M1D10
18 31 2 7
M1A9 A10 I/O10 BR177 M1D9
19 30 3 6
M1A8 A9 I/O9 M1D8
20 29 4 5 MNR04 33
M1A7 A8 I/O8 M1D7
21 16 1 8
M1A6 A7 I/O7 M1D6
24 15 2 7
M1A5 A6 I/O6 BR176 3 M1D5
25 14 6
M1A4 A5 I/O5 MNR04 33 4 M1D4
26 13 5
M1A3 A4 I/O4 M1D3
27 10 1 8
K M1A2 A3 I/O3 M1D2
42 9 2 7
M1A1 A2 I/O2 M1D1
43 8 3 6
GN D M1A0 A1 I/O1 M1D0
44 7 4 5
A0 I/O0 B
6 22 TP368
R123 100 TP1011 M1CE- CE NC TP369
17 23
M1WE- WE NC TP367 +3.3V
41 28
C139 C140 M1OE- OE NC
39
M1LB- LB
40 11
B2200/50 F0.01u/50 M1UB- UB VCC
33
VCC C142
12 A33u/10
VSS
34
GN D GN D VSS C143
F0.1u/16 C144
F0.1u/16
IS61LV6416-12T
GN D
2 1
MDM3.3V MDM1.8V
C282 C283
A33u/10 A33u/10 MDM3.3V
+3.3V TP1241
C284 C294
F0.1u/16 F0.1u/16
C285 C295
F0.1u/16 F0.1u/16 R296 0
C320 C286 C296
D F0.1u/16 F0.1u/16 F0.1u/16 R297 0
C287 C297
R167 4.7K F0.1u/16 F0.1u/16 C255
GN D MDM3.3V C288 C298 F0.1u/16
14
R1031 33 12 13 TP1258 R170 33 TP601 F0.1u/16 F0.1u/16
MDMIRQ C289 C299
7
IC 89F F0.1u/16 F0.1u/16
TC74LCX04FT C290 C300
F0.1u/16 F0.1u/16
GN D R380 R(NM) C291
R532 F0.1u/16
IC 24D 14 IC 24C IC 24B IC 24A
14 14 14 33 C292
TP750
R249 2K 9 8 TP749 5 6 3 4 1 2 TP751 F0.1u/16
CS5-
7 7 7 7 C293 C301
TC74LCX04FT TC74LCX04FT TC74LCX04FT TC74LCX04FT F0.1u/16 F0.1u/16 MDM3.3V
OSC5155
GN D GN D
34
92
78
68
44
30
15
55
54
97
86
62
42
21
53
52
IC 36
9
TP
IC 75A R533
VDDRE G
VDDRE G
REGOU T
REGOU T
AVDD
VDD3
VDD3
VDD3
VDD3
VDD3
VDD3
VDD3
VDD2
VDD2
VDD2
VDD2
VDD2
VDD2
1 62 1 26
T3IRQ NDBGREQ
3 27
DBGMOD GN
2 75 36
NDPCS PLLON R607 4.7K
RD - 74 33
TC74LCX08FT NDPRD TMS R608 4.7K
73 31
NDPWR TCK R609 4.7K
WE1- 71 29
NUB TDI R368 47K
WE0- 72 28
NLB TDO
R510 100 41
MDMRES- NRESET
39 TP1247
C402 MNR04 100 CXIN TP1248
38
C100/50 A11 CXOUT
4 5 100 43 MDMCLK
A10 DPA11 CLKOUT
3 6 98 37
A9 DPA10 CNT
2 7 96 51
A8 MNR04 100 DPA09 LON
1 8 95 1 2 JP 15
GN D A7 DPA08 SD00415- 52
4 5 94 45
A6 BR111 DPA07 SCANNT
3 6 93 46 1 2 JP 16
A5 DPA06 MINTEST SD00415- 52
2 7 91 48
A4 MNR04 100 DPA05 INTEST
1 8 90 49
A3 DPA04 MODE0
4 5 88 50
A2 BR112 DPA03 MODE1 GN D
3 6 87
A1 DPA02 MN195006E
A[1:25] 2 7 85 57
C TP29 DPA01 EYECLK R315 R316
1 8 84 58
DPA00 EYEDAT 47K 47K
MNR04 100 BR113
GN D D1 5 4 5 25 59
D1 4 DPD15 ABITCLK
3 6 24 60
D1 3 DPD14 ASPCLK
2 7 22 63
D1 2 MNR04 100 DPD13 ATXD
1 8 20 61
D1 1 DPD12 ARXD
4 5 19
D1 0 BR118 DPD11
3 6 18
D9 DPD10
2 7 16 65
D8 MNR04 100 DPD09 BBITCLK
1 8 14 66
D7 DPD08 BSPCLK
4 5 13 69
D6 BR119 DPD07 BTXD
3 6 12 67
D5 DPD06 BRXD
2 7 10
D4 MNR04 100 DPD05
1 8 8
D3 DPD04
4 5 7 76
D2 BR120 DPD03 GPIO0
3 6 6 77
D1 DPD02 GPIO1
2 7 4 79
D0 DPD01 GPIO2
D[0:15] 1 8 2 81
DPD00 GPIO3
82
BR121 GPIO4
83
GPIO5
AVSS
VSS
VSS
VSS
VSS
VSS
VSS
VSS
VSS
VSS
VSS
VSS
VSS
VSS
R320 R321
47K 47K
5
35
99
89
80
70
64
56
47
40
32
23
17
11
GN D GN D GN D
GN D
14 IC89D 14 IC 89E
R566 33 8 9 10
7 7
TC74LCX04FT TC74L
B
GN D GN D
8 7 6 5
7/10
OUT2
4 D
C257
C255 C256 A33u/10 (NM)
1
1u/16 F0.1u/16
C315
F0.1u/16
SI3OUT
C416
GN D B0.027u/10
R377 0
R378 0 MDM3.3V CN7
R512 1
0 R370 20K TX+
2
MDM3.3V RX+
3
X8 R511 RX-
4
OSC515500J IS-24.576MH z-3.3TR R(NM) C317 C316 Vhnd TX-
3 1 F0.1u/16 A10u/16 (NM) B4B-PH-K-S(NM)
TP1249 OUT OE
FB 21
2 4 MEM2012(NM) GN D
GND VDD C311
GN D IC 87 F1u/10( 1608) IC 88
6
GN D GN D
1 16 R372 15K 4
C304 F0.1u/16 SPKRR SPKRL
2 15 2 5
MBIAS LINEO
3 14 3
HDST GND C308 NJM2135M(NM)
4 13
SDI VA A10u/16 (NM)
5 12
1
7
8
SDO VD
6 11
MDMCLK FSYNC LINEI C312 C310
7 10
MCLK MIC F10u/10( 3216)(NM) F1u/10( 1608)
8 9
SCLK RESET
MDMCLK
MDM_ASPCLK
MDM_ATXD
MDM_ARXD
MDM3.3V
AFERES-
GN D GN D GN D GN D
MDM3.3V
R314
47K
14 IC 89E
10 11 MDM_ABITCLK
7
4FT TC74LCX04FT
+3.3V +3.3V
C414 C415
F0.1u/16 F0.1u/16 TP147
IC24F 14
13 12 TP148
GN D GN D 7
TC74LCX04FT
GN D
R622
R620 0
0
MDM3.3V
R621 Vhnd
R(NM)
+5V FB 24
MEM2012(NM)
GN D GN D
GN D A
4 3 2 1
FAXREQ1P-
R298 0 R182 R(NM) R183 0
3.3VGA2 3.3VGA2 3.3VGA2 3.3VGA2 GN D
R299 0
FAXACK1P-
FAXCS1P-
R272 0 C179 C180 C181 C182 C18
CK IO_GA2
WAI T-
F0.1u/16 F0.1u/16 F0.1u/16 F0.1u/16 F0.1u
IRQ 2-
CS2-
R184 0 TP1063
WE1-
WE0-
BS-
RD-
GN D GN D GN D GN D
+3.3V 3.3VGA2 D[0:15]
R2 17
4
33
FB10
D1 5
D1 4
D1 3
D1 2
D1 1
D1 0
TP212
TP213
TP211
TP214
TP210
A25
A24
A23
A22
D9
D8
D7
D6
D5
D4
D3
D2
D1
D0
MEM2012(NM)
C340
264 TP215
A33u/10
GN D
304
303
302
301
300
299
298
297
296
295
294
293
292
291
290
289
288
287
286
285
284
283
282
281
280
279
278
277
276
275
274
273
272
271
270
269
268
267
266
265
263
262
261
260
259
258
257
256
255
GN D
VDD- 304
VDD- 303
GND- 300
GND- 297
VDD- 296
GND- 293
GND- 290
VDD- 289
GND- 286
GND- 285
GND- 282
GND- 279
VDD- 278
GND- 275
GND- 268
GND- 267
VDD- 266
VDD- 265
D[9]
D[8]
D[7]
D[6]
D[5]
D[4]
D[3]
D[2]
D[1]
D[0]
NC[3 ]
NC[2 ]
BSSEL[ 1]
BSSEL[ 0]
NC[1 ]
WAIT_N
RD_ N
IRQ[2]_N
D[15]
D[14]
D[13]
D[12]
D[11]
D[10]
A[25]
A[24]
A[23]
WE1_N
WE0_N
CS5_N
BS_N
CLK_SYS
BR180 1
MNR04 33 GND-1
2
G2 D7 1 GND-2
G2D[0:7] 8 3
G2 D6 2 G2D[7]
7 4
GN D G2 D5 3 G2D[6]
6 5
G2 D4 4 G2D[5]
5 6
5
6
7
8
3.3VGA2 G2 D3 G2D[4]
1 8 7
BR75 G2 D2 G2D[3]
2 7 8
MNR04 4.7K G2 D1 G2D[2]
3 6 9
TP257 G2D[1]
10
4
3
2
1
TP858 NC[0]
11
TP855 TCK
12
TP856 TDI
13
TP857 TRST
14
G2 D0 TDO IC 38
4 5
15
G1 D7 BR181 G2D[0]
G1D[0:7] 16 uPD65954G L-061NMU
3.3VGA2 G1 D6 MNR04 33 G1D[7]
17
G1 D5 G1D[6]
18
G1D[5]
19
C184 VDD-19
20
F0.1u/16 G1 D4 GND-20
21
G1 D3 G1D[4]
22
G1 D2 G1D[3]
23
GN D G1 D1 G1D[2]
24
G1 D0 G1D[1]
25
G2ACK- G1D[0]
26
G2REQ- R1032 33(1608)27 G2ACK_N
3 G1ACK- R1033 33(1608)28 G2REQ_N
G1REQ- G1ACK_N
29
R188 4.7K TP258 G1REQ_N
30
3.3VGA2 TMS
31
CD2CLK TP1046 GND-31
32
CD2 RES- TP880 CDCLK
33
CD2 IRQ0 TP896 CDRES_N
34
CD2 IRQ1 TP879 CDIRQ0
35
3.3VGA2 GN D CD2 UBE- TP881 CDIRQ1
36
CDUBE_N
37
VDD-37
38
C187 VDD-38
39
F0.1u/16 GND-39
40
CD 2CS- TP883 GND-40
41
CD2RD- TP882 R1034 33(1608)42 CDCS_N
GN D CD2 WR- TP884 R1035 33(1608)43 CDRD_N
CD2A[0:3] CDWR_N
CD 2A0 TP287 44
3.3VGA2 CD 2A1 TP288 CDA[0]
45
CD 2A2 TP289 CDA[1]
46
CD 2A3 TP290 CDA[2]
47
C189 CDA[3]
48
F0.1u/16 VDD-48
49
TP293 GND-49
CD2 REQC0 50
TP1104 CDREQC0
CD2 REQC1 51
GN D TP901 CDREQC1
52
CD2ACKC0- TP902 CDACKC0_N
53
CD2ACKC1- TP292 CDACKC1_N
CD2 REQD0 54
3.3VGA2 TP887 CDREQD0
CD2 REQD1 55
TP885 CDREQD1
CD2ACKD0- 56
CDACKD0_N
57
C191 VDD-57
58
F0.1u/16 CD2ACKD1- R1014 33 TP886 GND-58
59
CD 2D0 TP806 CDACKD1_N
60
GN D CD 2D1 TP807 CDD[0]
61
3.3VGA2 CD 2D2 TP804 CDD[1]
62
CD 2D3 TP809 CDD[2]
63
CDD[3]
64
C193 VDD-64
65
F0.1u/16 CD 2D4 TP808 GND-65
66
CD 2D5 TP805 CDD[4]
67
GN D CD 2D6 TP810 CDD[5]
68
2 3.3VGA2 CD 2D7 TP811 69
CDD[6]
CD 2D8 TP812 CDD[7]
70
CDD[8]
71
C195 VDD-71
72
F0.1u/16 CD 2D9 TP815 GND-72
73
CD 2D10 TP814 CDD[9]
74
CDD[10]
75
GND-75
76
GND-76
GND- 105
GND- 115
GND- 116
GND- 125
VDD- 104
VDD- 113
VDD- 114
VDD- 124
CDD[1 1]
CDD[1 2]
CDD[1 3]
CDD[1 4]
CDD[1 5]
TRES_N
MWE _N
GND- 87
GND- 95
GND- 96
VDD- 77
VDD- 78
VDD- 86
MOE_N
GN D
MCE _N
MD[1 0]
MA[10]
MA[11]
MA[12]
MA[13]
MA[14]
MA[15]
MD[0 ]
MD[1 ]
MD[2 ]
MD[3 ]
MD[4 ]
MD[5 ]
MD[6 ]
MD[7 ]
MD[8 ]
MD[9 ]
MA[0]
MA[1]
MA[2]
MA[3]
MA[4]
MA[5]
MA[6]
MA[7]
MA[8]
MA[9]
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
CD2 D1 1 TP813
CD2 D1 2 TP816
CD2 D1 3 TP817
CD2 D1 4 TP818
CD2 D1 5 TP819
TP295
33 TP843
33 TP842
33 TP841
8 TP853
7 TP850
6 TP849
5 TP827
TP824
TP826
TP825
TP820
8 TP822
7 TP821
6 TP823
5 TP831
8 TP828
7 TP830
6 TP829
5 TP832
TP840
33 TP838
TP839
TP837
8 TP836
7 TP835
6 TP834
5 TP833
TP851
33 TP852
TP845
TP844
MNR04 33
MNR04 33
BR182
BR184
BR185
8BR187
MNR04
MNR04
R1004
R1002
R1003
CD2 D[ 0:15]
1
2
3
4
M2A8 BR183 1
M2A9 MNR04 332
3
4
1
2
3
4
1
2
3
4
8
7
6
5
8
7
6
5
7
6
5
MNR04 33
MNR04 33
BR186
BR188
M2A[0:15]
IC 41
M2A4 1
M2A5 2
M2A6 3
M2A7 4
M2 D0 1
M2 D1 2
M2 D2 3
M2 D3 4
1
2
3
4
M2CE-
M2OE-
M2WE-
M2A10
M2A11
M2A12
M2A13
M2A14
M2A15
M2A0
M2A1
M2A2
M2A3
M2D10
M2D11
M2A15 M2D15
M2 D4
M2 D5
M2 D6
M2 D7
M2 D8
M2 D9
1 38 1 8
M2A14 A15 I/O15 M2D14
2 37 2 7
M2A13 A14 I/O14 M2D13
3 36 3 6
M2A12 A13 I/O13 M2D12 M2D[0:15]
4 35 4 5
M2A11 A12 I/O12 M2D11
5 32 1 8
M2A10 A11 I/O11 BR190 M2D10 3.3VGA2 3.3VGA2 3.3VGA2 3.3VGA2 3.3VGA2
18 31 2 7
M2A9 A10 I/O10 MNR04 33 3 M2D9
19 30 6
M2A8 A9 I/O9 M2D8
20 29 4 5
M2A7 A8 I/O8 M2D7 C197 C198 C199 C200 C201
21 16 1 8
M2A6 A7 I/O7 M2D6
24 15 2 7 BR191 F0.1u/16 B0.1u/25(1608) B0.1u/25( 1608) B0.1u/25( 1608) B0.1u/25( 1608)
1 M2A5 25
A6 I/O6
14 3 6 MNR04 33 M2D5
M2A4 A5 I/O5 M2D4
26 13 4 5
M2A3 A4 I/O4 M2D3 GN D GN D GN D GN D GN D
27 10 1 8
M2A2 A3 I/O3 BR192 M2D2 3.3VGA2
42 9 2 7
M2A1 A2 I/O2 MNR04 33 3 M2D1
43 8 6
M2A0 A1 I/O1 M2D0
44 7 4 5
A0 I/O0 C202
6 22 TP261 BR193 F0.1u/16
M2CE- CE NC TP260 MNR04 33
17 23
M2WE- WE NC TP259 +3.3V
41 28
M2OE- OE NC C205 GN D
39
LB B0.1u/25(1608)
40 11
UB VCC
33
VCC C203
12 A33u/10
VSS
34
VSS C204
GN D F0.1u/16
IS61LV6416-12T GN D
A B C
8/10
3.3VGA2
FAXREQ1P-
GN D 3.3VGA2
C178
F0.1u/16
C183
F0.1u/16
CS2-
GN D GN D
WE0-
BS-
RD-
WE1
GN D
A[1:25]
4
TP210
A25
A24
A23
A22
A21
A20
A19
A18
A17
A16
A15
A14
A13
A12
A11
A10
A9
A8
A7
A6
A5
A4
A3
A2
A1
263
262
261
260
259
258
257
256
255
254
253
252
251
250
249
248
247
246
245
244
243
242
241
240
239
238
237
236
235
234
233
232
231
230
229
GND- 248
GND- 247
VDD- 230
VDD- 229
NC[1 ]
RD_ N
A[9]
A[8]
A[7]
A[6]
A[5]
A[4]
A[3]
A[2]
A[1]
A[25]
A[24]
A[23]
A[22]
A[21]
A[20]
A[19]
A[18]
A[17]
A[16]
A[15]
A[14]
A[13]
A[12]
A[11]
A[10]
WE1_N
WE0_N
CS5_N
BS_N
228
GND-228
227
GND-227 TP169
226
TOUT5 TP170 GN D
225
TOUT4 TP168
224
TOUT3 TP167
223
TOUT2 TP174
222
TOUT1 TP166 R185 4.7K
221 3.3VGA2
TIN TP176 R186 4.7K
220
TEB_N TP175 R187 4.7K
219
TMOD1_N TP163
218 READ Y-
READY_N TP159 R1039 33(1608)
217 FAXPAGE-
FAXPAGE_N TP165
216 PR LINE-
PRLINE_N TP164
215 SC LINE-
SCLINE_N TP155
214 HS YNC-
HSYNC_N GDATA15 R513
213 GDATA[0:15]
GDATA[15] GDATA14 0
212
GDATA[14] GDATA13 +5V
211
GDATA[13]
210
GND-210 C185 GN D
209
VDD-209 GDATA12
208 3.3VGA2
GDATA[12] GDATA11 F0.1u/16
207 FB 22
GDATA[11] GDATA10
206 MEM2012(NM)
GDATA[10] GDATA9
205
GDATA[9] GDATA8 GN D
204
GDATA[8] GDATA7 R515 100 RES-
203
GDATA[7] GDATA6 IC 39
202
GDATA[6] GDATA5 TR 3
201 13 11
GDATA[5] GDATA4 C403 TR CKO TP908
200 10
GDATA[4] GDATA3 C100/50 /CKO TP903
199 12 7
GDATA[3] GDATA2 VCC CKO/2 TP904
198 16 6
GDATA[2] GDATA1 R514 TP173 VCC /CKO/2 TP909
197 9
GDATA[1] GDATA0 GN D R(NM) X7 CNTCK TP906
196 4
GDATA[0] TP171 R1000 33 PULSE
195 1 3 1
TR OE OUT CLKIN
194
RES_N TP172 TP907
193 4 2 2
CLK_VID VDD GND C186 TEST1 TP905
192 5 3
GND-192 OSC515101J IS-28.16301M Hz-5.0TR F0.1u/16 GND TEST2 TP910
191 8 15
GND-191 C188 GN D GND TEST3
190 14
VDD-190 F0.1u/16 C254 GND
189 3.3VGA2
VDD-189 TP156 R1038 33(1608) FAXPRD- F0.1u/16
188 3.3VGA2 K
FAXPRD_N TP755 FAXREQ0P- GN D M66235FP
187
FAXREQOP_N TP151 R1037 33(1608) FAXACK0P- R1015 1K
186 AK
FAXACKOP_N TP152 R1036 33(1608) FAXCS0P-
185
FAXCSOP_N TP191 SDRA M_D15 TP779 D2 0 R1016
184 1 8 SDRAM_D[0:15] A
SDRAM_D[15] TP763 SDRA M_D14 TP764 DA204K 2K
183 2 7
SDRAM_D[14] TP190 SDRA M_D13 TP778
182 3 6
SDRAM_D[13] SDRA M_D12 TP765 3.3VGA2
181 4 5
GND-181 GN D
180
VDD-180 TP762 BR 77 MNR04 33
179
SDRAM_D[12] TP189 BR 76 SDRA M_D11 TP777 C190 GN D
178 1 8
SDRAM_D[11] TP761 SDRA M_D10 TP766 F0.1u/16
177 2 7
SDRAM_D[10] TP188 SDRA M_D9 TP776
176 3 6
SDRAM_D[9] TP760 SDRA M_D8 TP767 GN D
175 4 5
SDRAM_D[8] TP187
174
SDRAM_D[7] TP759 MNR04 33 BR 78 3.3VGA2
173
SDRAM_D[6] SDRA M_D7 TP775
172 1 8
GND-172 SDRA M_D6 TP768
171 2 7
VDD-171 TP186 SDRA M_D5 TP774 C192
170 3 6
SDRAM_D[5] TP758 BR 79 SDRA M_D4 TP769 F0.1u/16
169 4 5
SDRAM_D[4] TP185 SDRA M_D3 TP773
168 1 8
SDRAM_D[3] TP757 SDRA M_D2
167 2 7 MNR04 33 TP770 GN D
SDRAM_D[2] TP177 SDRA M_D1 TP772
166 3 6
SDRAM_D[1] TP756 SDRA M_D0 TP771
165 4 5
SDRAM_D[0] TP208 3.3VGA2
164
SDRAM_A[12] MNR04 33 BR 80
163
GND-163 SDRA M_A12 TP795
162 1 8
VDD-162 TP184 SDRA M_A11 TP796 C194
161 2 7
SDRAM_A[11]
160 TP178 3 6 SDRA M_A10 TP797 F0.1u/16 2
SDRAM_A[10] TP180 BR 81 SDRA M_A9 TP798
159 4 5
SDRAM_A[9] TP179 SDRA M_A8 TP799
158 1 8
SDRAM_A[8] TP181 SDRA M_A7
157 2 7 MNR04 33 TP800 GN D
SDRAM_A[7] TP182 SDRA M_A6 TP801
156 3 6
SDRAM_A[6] TP183 SDRA M_A5 TP802
155 4 5
SDRAM_A[5]
154
SDRA M_RAS_N
SDRA M_CAS_N
GND-154
SDRA M_WR_ N
SDRA M_DQM0
SDRA M_DQM1
SDRA M_CS_N
153 MNR04 33
SDRAM_BA[0]
SDRAM_BA[1]
SDRA M_CKE
GND-153
SDRA M_CLK
SDRA M_A[0]
SDRA M_A[1]
SDRA M_A[2]
SDRA M_A[3]
SDRA M_A[4]
GND- 125
GND- 133
GND- 134
GND- 143
VDD- 124
VDD- 142
VDD- 151
VDD- 152
MD[1 0]
MD[1 1]
MD[1 2]
MD[1 3]
MD[1 4]
MD[1 5]
MD[4 ]
MD[5 ]
MD[6 ]
MD[7 ]
MD[8 ]
MD[9 ]
GN D
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
151
152
7 TP835
6 TP834
5 TP833
TP851
33 TP852
TP845
TP844
8 TP846
7 TP847
6 TP848
5 TP854
TP202
TP200
TP201
TP199
TP198
TP197
TP196
TP195
TP194
TP193
TP192
TP203
TP204
TP205
TP206
TP207
8
MNR04 33
BR 82
8BR187
BR189
MNR04
8
7
6
5
8
7
6
5
7 MNR04 33
7 MNR04 33
1
2
3
4
1
2
3
4
7
6
5
MNR04 33 BR 83
MNR04 33
BR188
1
2
3
4
1
2
3
4
8
6
5
6
5
MNR04 33
1
2
3
4
M2D10
M2D11
M2D12
M2D13
M2D14
M2D15
BR 84
BR 85
M2 D5
M2 D6
M2 D7
M2 D8
M2 D9
1
2
3
4
1
2
3
4
TP784
TP786
TP785
TP787
TP788
TP789
TP790
TP791
TP792
TP793
TP794
TP783
TP782
TP781
TP780
TP209
3.3VGA2 3.3VGA2
S DRAM_A0
S DRAM_A1
S DRAM_A2
S DRAM_A3
S DRAM_A4
C201 C196
SD RAM_CS-
SDRAM_RAS-
SDRAM_CAS-
SDRA M_WR-
SDRAM_DQM0
SDRAM_DQM1
SDRAM_BA0
SDRAM_BA1
SDRAM_CLK
SDRAM_CKE
C202
0.1u/16
GN D
C D E
C D2ACKD0- 9
C D2ACKD0-
8 R611 33 C D2ACKD-
C D 2ACKD-
C D2ACKD1- 10
C D2ACKD1-
D IC 82C
TC74LCX08FT
+3.3V C306
F 0.1u/16
14
GND
C D2ACKC0- 12
C D2ACKC0- C D2ACKC- C D 2REQD
11 R612 33
C D 2ACKC-
C D2ACKC1- 13
C D2ACKC1-
IC 82D
TC74LCX08FT
7
GND IC 80A
C D2ACKD- 1
C D2ACKD-
3
2
TC74LCX08FT
SD RAM_D[0:15]
BR99 BR100 BR101 BR102
SDRAM_A[0:12]
+3.3V MNR04 (NM) MNR04 (NM) MNR04 (NM) MNR04 (NM)
4
3
2
1
4
3
2
1
4
3
2
1
4
3
2
1
BR143
IC 42 MNR04 33
C D 2REQC
5
6
7
8
5
6
7
8
5
6
7
8
5
6
7
8
SDRAM_A0 23 2 1 8 SDRAM_D0
C SDRAM_A1 A0 I/O0 SDRAM_D1
24 4 2 7
SDRAM_A2 A1 I/O1 SDRAM_D2
25 5 3 6 BR144
SDRAM_A3 A2 I/O2 SDRAM_D3
26 7 4 5 MNR04 33
SDRAM_A4 A3 I/O3 SDRAM_D4 +3.3V
29 8 1 8
SDRAM_A5 A4 I/O4 SDRAM_D5 C 263
30 10 2 7
SDRAM_A6 A5 I/O5 BR145 SDRAM_D6 F 0.1u/16
31 11 3 6
SDRAM_A7 A6 I/O6 MNR04 33 4 SDRAM_D7
32 13 5
SDRAM_A8 A7 I/O7 SDRAM_D8
14
33 42 1 8
SDRAM_A9 A8 I/O8 SDRAM_D9 GND
34 44 2 7
SDRAM_A10 A9 I/O9 SDRAM_D10 C D2ACKC-
22 45 3 6 BR146 C D2ACKC- 12
SDRAM_A11 A10 I/O10 SDRAM_D11
35 47 4 5 MNR04 33 11
SDRAM_A12 A11 I/O11 SDRAM_D12
36 48 1 8 13
A12 I/O12 SDRAM_D13
50 2 7
I/O13 SDRAM_D14 IC 80D
20 51 3 6
7
SDRAM_BA0 BA0 I/O14 SDRAM_D15 TC74LCX08FT
21 53 4 5
SDRAM_BA1 BA1 I/O15
GND
19 1
SDRAM_CS- CS VCC
16 3
SDRAM_WR- WE VCC
17 9
SDRAM_CAS- CAS VCC +3.3V
18 14
SDRAM_RAS- RAS VCC
15 27
SDRAM_DQM0 DQML VCC
39 43 GDMAE
SDRAM_DQM1 DQMU VCC
38 49
SDRAM_CLK CLK VCC C 219
37
SDRAM_CKE CKE A33u/10
6
TP1095 40 GND
12
5
6
7
8
GND GND
54 CD2RES-
R218 BR103 GND
4.7K MNR04 4.7K
GND
W 981216BH-75
R 565 R(NM)
C305
+3.3V
F 0.1u/16
B
14 GND
CLK16M 12
11 R 564 33
13
IC 79D
7
TC74LCX32FT
GND G ND
C 307
+3.3V
F 0.1u/16
GND
10
14
12 9 TP1245
PR
VCC
D Q
11
CLK
GND
TP1246
CL
8
Q
IC 86B
13
TC74LCX74FT
G ND
A
5 4 3
9/10
IC 79C R 1048 D
9 33(1608)
8 GDMA
10
+3.3V TC74LCX32FT
C261 +3.3V
F 0.1u/16
IC 78A
IC 78B GND R1045 IC 79A R1046 TC74LCX74FT R1044
10
14
4
TC74LCX74FT 33(1608) IC 80B R1049 1 33(1608) 33(1608) IC 75B R1041
12 9 4 33(1608) 3 2 5 4 33(1608)
PR
VCC
PR
C D 2REQD D Q D Q
6 2 6 C D 2REQD0
11 5 3 5
CLK CLK
TC74LCX32FT
GND
TC74LCX08FT
CL
CL
8 TC74LCX08FT 6
Q Q
13
1
C 161
+3.3V
F 0.1u/16
IC 80A
GND
14
3
R1043
12 G ND 33(1608)
TC74LCX08FT 11 C D 2REQD1
13
IC 75D
7
TC74LCX08FT
14
IC 79B 9
4
TC74LCX74FT IC 80C R1050 4 33(1608) 8 C D 2REQC0
12 9 9 33(1608) 6 2 5 10
PR
VCC
PR
C D 2REQC D Q D Q
8 5
11
CLK
10 3
CLK
TC74LCX08FT C
TC74LCX32FT
GND
CL
CL
8 TC74LCX08FT 6
.3V Q Q
C 263
13
1
F 0.1u/16
IC 74
1 3 TP1111
GND GND A QA TP1110
2 4
B QB TP1109
5
QC TP1108
11 6
QD TP1107
10
QE TP1106
8 11
IC 80D CLK QF TP1105
12
TC74LCX08FT QG
9 13 C D 2REQC1
CLR QH
14 +3.3V
ND +3.3V VCC
C 240
7 F 0.1u/16
GND
IC 86A TC74VHC164FT
4
G ND
2 5
PR
D Q
3
CLK
CL
6
Q
TC74LCX74FT
1
IC 20F14
R 565 R(NM) 13 12 R1040 33(1608)
G C CH
7
TC74LCX04FT
B
R 564 33 TP1244
3 2 1
VR EF
R125 56K
D
C146
VR EF
F0.1u/16
R126 10K TP521 TP514 R127 3.3K TP520 R128 56K
BZ
R129
C147 1K R516
B4700/25 1M
VR EF
C148
GN D GN D F0.1u/16
IC 33 IC 34
R130 R(NM) 12 13 TP12 TP523 13 3
X0 X R132 5.1K TP16 X0 X
C281 14 14
SPOUT TP1243 R133 10K TP517 X1 TP11 R134 10K TP13 X1
SPOUT 15 3 15
VSEL R135 56K TP518 X2 Y R136 18K TP17 X2
F0.1u/16 11 12
C127 X3 R137 33K TP512 X3
1
B2200/50 VSEL R138 62K TP509 X4
1 5
Y0 R139 200K TP511 X5
5 2 16
R140 R141 Y1 R142 360K TP510 X6 VDD
2 16 4
Q3 10K 10K Y2 VDD X7
4
GN D DTC363EKA T146 Y3 C149
6 6
TP10 INH F0.1u/16 INH
VOLCNT [A] B C 10 7 11 7
A VEE A VEE
9 8 10 8
Q4 B VSS B VSS
9
E
GN D
VSEL
C
R145 R146 R147
Q5 10K 10K 10K
DTC363EKA T146
B C TP21
VO L[A]
Q6
DTC363EKA T146
E
B C TP20
VO L[B]
Q7
DTC363EKA T146
E
B C TP19
VO L[C]
E
C404 A
A47u/16
ZD 1 D19 DA20
UDZ2.0B CN8 GN D
+5VS 1
RHS
2
DG
B2B-PH-K-S(NM)
GN D C319 GN D
F0.1u/16
GN D MDM_A
14 IC 89C
14
IC 90A RG
6 5 AFE
CI
S 1 7
TC74LCX04FT MDM_AB
3
B 2 R1018 33 SP
SI3O
R406 12
10K TC74VHCT00FT 11
13
GN D
14 IC20D
TP153 8 9
+5VS EXHS-
7
TC74LCX04FT
Q16
DTC114EKA T146 C323
14 IC 92A F0.1u/16 GN D
C B 2 1
IC 92D 14 7
9 8 +5VS TC74VHC04FT
E
R522 0 7
TC74VHC04FT
GN D
R385 Q17 GN D
IC 92E 14 R(NM) DTC114EKA T146
11 10 14 IC 92B
R524 0 7 C B 4 3
A TC74VHC04FT FAXWU-
7
CI D2-
R386 TC74VHC04FT
E
IC 92F 14 0
13 12
R525 0 7 GN D
TC74VHC04FT Q18
DTC114EKA T146
14 IC92C
GN D C B 6 5
7
TC74VHC04FT
E
GN D GN D GN D
4 3
10/10
+5V
D
C228
VR EF +5V
B1000/50
C2 27
TP535 TP536 A4.7u/50
R399 R198
SP OUT
1M R(NM) TP27 R199 100K R200 430K GN D
C229
F0.1u/16 C230
6
R201 R202 CN9
A10u/16V (NP)(NM)
3 TP522 R131 6.2K TP533 TP531 0 TP532 3.3K 4 B3B-PH-K-S
X SP+ TP1096
2 5 1
TP28 1
3 2
IC 43 2
3
VSEL NJM2113M 3
1
7
8
R203 0
16
VDD TP534 TP537 SP-
C150
7 F0.1u/16
VEE C231 C232
8
VSS A4.7u/50 A4.7u/50
GN D
CF
TX25-30P-6ST-H1
TP1229
TP1228
5
6
7
8
5
6
7
8
C405 C234
C(NM) A33u/10
C235 C236
A47u/16 A47u/16
4
3
2
1
4
3
2
1
4
3
2
1
GN D GN D
2 1
A B C
LIU PWB
R182
(E) 1.78KF 2W
R179
(U) 5.36KF 1/4W
R180
(U) 5.36KF 1/4W
4 R181
Q118 Q117 (U) 5.36KF 1/4W
2SC4548 (SC-62) 2SD1733 (SC-63)
C E C E
R184
100KF
B0.22u/16V
B
B
C E
B1u/16V
C43
C42
Q113
(NM) 2SD1266A (TO-220)
B
R185
150
IC4
Q119 C45 16
2SA1759 (SC-62) B0.1u/50V FILT2
15 FILT
E C 14 RX
13 REXT
R186 12
2.2K 1/10W REXT2
11 REF
B
10 VREG2
9 VREG
Si3015-KS
B1800p/50V
R190
78.7F
R189
120K
RD43FM
(U) 5.36KF 1/4W (3225)
R191
402F
C50
ZD18
(E) 1.78KF 2W
R177
R194
R193
R192
C48
RLZ5.6B
B0.01u/50V
B0.1u/16V
B0.1u/16V
R195
9.31KF
ZD19
B0.68u/16V
C52
C51
C53
R196
215F
(U) DSS-401M (E) DSS-301L
3 Q120 B
2SC4548 (SC-62)
(NM) DSSA-P3100SB
R203 C96
680 1/10W C86 (NM) B4
33p/50V
H1 (NM) B0.027u/50V
C66
C87
VA5
SA6
10M
L1 L13 0 1/4W
1000p/AC250V
R200
C57
L25 D8
6
C58
SBT-0260 2 1
L16
SA7
MJ-64J-RD315 L21
ST-110AV
(NM) 1000p/AC250V
3 4
R201
10M
C62
1000p/AC250V S1ZB60
(NM) B0.01u/250V
DSS-401M
C61
C65
L23
(NM) EL0607RA-331J
SA5
L12
33p/50V
BLM31A601S C63
C67
R204 B470p/2
680 1/10W
C97
(NM) B4
0 1/10W
0 1/10W
2 C90 C91
(E) A4.7u/50V(N.P.) (E) A4.7u/50V(N.P.)
R251 R252
(U) EL0607RA-331J (E) 10 1/4W (U) EL0607RA-331J (E) 10 1/4W
R243
R246
L6
(E) LHL08TB102J
S4A
1
3 2
(NM) OUAZ-SH-105D
C25
6
L9 R205
4 8 0.22u 2
SBT-0260
(U) 91 1/4W (E) 0 1/4W S3A
RSB-5
1 MJ2
1
2 11
T1 L10
3 T2
4 13 9
5 SBT-0260
S3B
6 RSB-5
MJ-62J-RD315
JP5
(NM) 0 1/4W
A B C
1/2
R179
(U) 5.36KF 1/4W (3225)
R180
(U) 5.36KF 1/4W (3225)
R181 4
(U) 5.36KF 1/4W (3225) R255 0
RGDT-
DAA3.3V
DAA3.3V DAA3.3V
B0.22u/16V
DAA3.3V R183
0
C94
C68 IC3 B1000p/50V (1005)
16 OFHK MCLK 1 MDMCLK
IC4 15 2
RGDT/FSD FSYNC MDM_ASPCLK
16 1 10p/50V (1608) 14 3
FILT2 QE2 M0 SCLK MDM_ABITCLK
15 FILT DCT 2 13 VA VD 4
14 3 R188 C46 R187 12 5
RX IGND GND SDO MDM_ARXD
13 REXT C1B 4 11 C1A SDI 6 MDM_ATXD
12 REXT2 RNG1 5 10 M1 FC/RGDT 7
11 6 10 1/10W 150p/AC250V 10 1/10W 9 8
REF RNG2 AOUT RESET AFERES-
10 VREG2 QB 7
9 8 Si3021-KS
VREG QE
Si3015-KS C47
B0.1u/16V
B0.22u/16V
DAAGND R264
DAAGND 10K (1608)
DAN217
RLZ5.6B
AK
D6
C49
DAN217
RLZ5.6B
D7
B0.1u/16V
AOUT
ZD17
DAAGND
ZD19
C51
AK
(NM) B0.022u/250V (3216)
R198
B0.022u/250V (2125)
0
A
R197
0 +3.3V DAA3.3V
3
DAAGND DG 1 3
C98
C59
FB2
C64 150p/AC250V (NM) MEM2012
2
DAAGND
C96
(NM) B470p/250V (3216)
C55
B470p/250V (1608)
(U) DSS-401M (E) DSS-301L
B3300p/50V
(NM) B0.01u/250V
C56
SA7
C69
B3300p/50V
VA4
(NM) DSSA-P3100SB
C60
C63 +5VS
B470p/250V (1608)
C97
(NM) B470p/250V (3216)
IC9
2
5
2 R262
C92 4 HS1-
(E) F0.1u/16V (1005) 1
0
(E) NC7ST08M5X
3
1 7
6
5
4
2 3
IC6
(E) THS-56F
Q133
(E) DTC114EKA R263
AG B C HS2-
0
E
(U) HZS2C1
(U) 30 1/4W
ZD24
R206
AG
(U) HZS2C1
4
ZD25
PC11 C95
(U) TLP620 (U) B1000p/50V (1005)
1
ZD12 AG
C25 R168 MTZJ30B +5VS
R209
0
0.22u 250V 39K 1W
CID2-
1
D2
1SS355 PC6 Q130
TLP621 DTC114EKA R266
B C
1
CID-
2
A0.33u/50V
B1000p/50V (1005)
0
+
E
C72
R253
10K (1608)
C73
C D E
AG
TP3
+5VS
0 1/4W (JP)
+5VS
+ C35
F0.1u/16V (1005)
C39
(NM) A47u/25V
AG AG
TP5
+5V
0 1/4W (JP)
TP4
+3.3V
0 1/4W (JP)
+5VS
D5
+ +
1SS355
C38
C41
C37
C40
Q116
A47u/25V
A47u/25V
DTD113ZK S3C
SON B C 16 1
2 - + 2
F0.1u/16V (1005)
F0.1u/16V (1005)
DG RSB-5
E
(NM) 0 1/4W (JP) 0 1/4W (JP) (NM) 0 1/4W (JP) (NM) OUAZ-SH-105D
R178
(NM) 0 1/4W
AG DG
1 1
A B C D
CAUTION FOR BATTERY REPLACEMENT
(Danish) ADVARSEL !
Lithiumbatteri – Eksplosionsfare ved fejlagtig håndtering.
Udskiftning må kun ske med batteri
af samme fabrikat og type.
Levér det brugte batteri tilbage til leverandoren.
(English) Caution !
Danger of explosion if battery is incorrectly replaced.
Replace only with the same or equivalent type
recommended by the manufacturer.
Dispose of used batteries according to manufacturer’s instructions.
(Finnish) VAROITUS
Paristo voi räjähtää, jos se on virheellisesti asennettu.
Vaihda paristo ainoastaan laitevalmistajan suosittelemaan
tyyppiin. Hävitä käytetty paristo valmistajan ohjeiden
mukaisesti.
(French) ATTENTION
Il y a danger d’explosion s’ il y a remplacement incorrect
de la batterie. Remplacer uniquement avec une batterie du
même type ou d’un type équivalent recommandé par
le constructeur.
Mettre au rebut les batteries usagées conformément aux
instructions du fabricant.
(Swedish) VARNING
Explosionsfara vid felaktigt batteribyte.
Använd samma batterityp eller en ekvivalent
typ som rekommenderas av apparattillverkaren.
Kassera använt batteri enligt fabrikantens
instruktion.
(German) Achtung
Explosionsgefahr bei Verwendung inkorrekter Batterien.
Als Ersatzbatterien dürfen nur Batterien vom gleichen Typ oder
vom Hersteller empfohlene Batterien verwendet werden.
Entsorgung der gebrauchten Batterien nur nach den vom
Hersteller angegebenen Anweisungen.
"BATTERY DISPOSAL"
THIS PRODUCT CONTAINS A LITHIUM PRIMARY
(MANGANESS DIOXIDE) MEMORY BACK-UP BATTERY
THAT MUST BE DISPOSED OF PROPERLY. REMOVE THE
BATTERY FROM THE PRODUCT AND CONTACT YOUR
LOCAL ENVIRONMENTAL AGENCIES FOR INFORMATION
ON RECYCLING AND DISPOSAL OPTIONS.
Trademark acknowledgements
• Microsoft® Windows® operating system is a trademark or copyright of Microsoft
Corporation in the U.S.A. and other countries.
• Windows® 95, Windows® 98, Windows® Me, Windows NT® 4.0, Windows® 2000,
and Windows® XP are trademarks or copyrights of Microsoft Corporation in the
U.S.A. and other countries.
• IBM and PC/AT are trademarks of International Business Machines Corporation.
• Acrobat® Reader Copyright® 1987- 2002 Adobe Systems Incorporated. All rights
reserved. Adobe, the Adobe logo, Acrobat, and the Acrobat logo are trademarks of
Adobe Systems Incorporated.
• All other trademarks and copyrights are the property of their respective owners.
SHARP CORPORATION
Digital Document System Group
Products Quality Assurance Department
Yamatokoriyama, Nara 639-1186, Japan
2003 October Printed in Japan