TITLE Modbus register for THERMOREGULATOR “TH” (CanBus)

Series

DOC. Ner KJA00301G

Revision Date Name Description


0 16/03/09 I.M. Issue
1 08/04/09 I.M. Update sheets 3/6, 6/6
2 04/05/09 I.M. Added sheet 2 and new logo
3 07/05/09 I.M. General revision
4 02/02/10 A.C. Release serial card 1.14
5 26/02/10 A.C. Release serial card 1.15

Code and firmware requirements table


Serial card code FW TH main card code FW HMI card Code FW
966S001 1.15 9686xxxx 1.18

Absolute addressing table


TH (Code 61)
Offset 1 500
Offset 2 549

USER VERSION

INTERNAL USE ONLY


INTERNAL USE ONLY

KJA00301G _TH_CanBus_Series_user version_R5.doc


TH- Firmware (FW) Read Table:
Register Description HMI-Ref. Type Mode Dec. Min Max Eng. Note WF Bios Compliance
N° (dec) Points Units Ready >=FW device
+99 Communication card FW INT R 2
+103 Main card FW INT R 2

Modbus Supported function CODE:


Functione code Description Note
&H03 Read Holding registers
&H04 Read Input registers Same effect as &H03 function code
&H06 Write single register
&H16 Write multiple registers

Card connections:
pin DB9 Female (CNP) DB9 Female (CNT)
1 RS 485 ( LIN +) RS 485 ( LIN +)
2 RS 485 ( LIN -) RS 485 ( LIN -)
3 GND GND
4
5
6 RS 485 ( LIN +) RS 485 ( LIN +)
7 RS 485 ( LIN -) RS 485 ( LIN -)
8
9

Card dip-switches settings:


DIP Description Note
Only dip 12 must be set to ON

KJA00301G _TH_CanBus_Series_user version_R5.doc 2/7


TH Offset 1 table:
Register Description HMI-Ref. Type Mode Dec. Min Max Eng. Note WF Bios Compliance
N° (dec) Points Units Ready >=FW device
+0 On Off device INT W 0 1 2 ALL
1: On
2: Off (cooling stop)
+1 Alarm Ack INT W 0 1 2 ALL
1: Horn reset
2: Alarms acknowledge
+2 Safety max temperature TSO INT R/W 1 0.0/32.0 250.0/482.0 °C/°F ALL

+4 Main set point SP INT R/W 1 0.0/32.0 SPmax °C/°F ALL


+5 Maximum set point SPmax INT R/W 1 0.0/32.0 °C/°F (*1) ALL
+6 High deviation set point d.Hi INT R/W 1 0.0 99.0 ALL
+7 Low deviation set point d.Lo INT R/W 1 0.0 99.0 ALL

+9 Mould discharge phase time Md INT W 0 0 999 s ALL


+10 Flow alarm mode All.Q INT W 0 0 (man) 1 (aut) ALL
+11 Minimum flow for manual alarm Q.min INT W 0 0 999 l/min ALL
+12 Flow reduction Scos.Q INT W 0 0 99 % ALL

Note:
(*1) Max value = offset 2+19 with “normal” pump mode
= offset 2+ 20 with “reverse” pump mod

KJA00301G _TH_CanBus_Series_user version_R5.doc 3/7


TH Offset 1 table (cont’):
Register Description HMI-Ref. Type Mode Dec. Min Max Eng. Note WF Bios Compliance
N° (dec) Points Units Ready >=FW device
+19 Clock 1 enable CLK.1.en INT R/W 0 0(off) 1(on) Y ALL
+20 Clock 1 hour set for on CLK.1.H.on INT R/W 0 00:00 23:59 (*1) Y ALL
+21 Clock 1 day set for on CLK.1.D.on INT R/W 0 1 10 (*3) Y ALL
+22 Clock 1 hour set for off CLK.1.H.off INT R/W 0 00:00 23:59 (*1) Y ALL
+23 Clock 1 day set for off CLK.1.D.off INT R/W 0 1 10 (*3) Y ALL
+24 Clock 2 enable CLK.2.en INT R/W 0 0(off) 1(on) Y ALL
+25 Clock 2 hour set for on CLK.2.H.on INT R/W 0 00:00 23:59 (*1) Y ALL
+26 Clock 2 day set for on CLK.2.D.on INT R/W 0 1 10 (*3) Y ALL
+27 Clock 2 hour set for off CLK.2.H.off INT R/W 0 00:00 23:59 (*1) Y ALL
+28 Clock 2 day set for off CLK.2.D.off INT R/W 0 1 10 (*3) Y ALL
+29 Clock 3 enable CLK.3.en INT R/W 0 0(off) 1(on) Y ALL
+30 Clock 3 hour set for on CLK.3.H.on INT R/W 0 00:00 23:59 (*1) Y ALL
+31 Clock 3 day set for on CLK.3.D.on INT R/W 0 1 10 (*3) Y ALL
+32 Clock 3 hour set for off CLK.3.H.off INT R/W 0 00:00 23:59 (*1) Y ALL
+33 Clock 3 day set for off CLK.3.D.off INT R/W 0 1 10 (*3) Y ALL
+34 Clock 4 enable CLK.4.en INT R/W 0 0(off) 1(on) Y ALL
+35 Clock 4 hour set for on CLK.4.H.on INT R/W 0 00:00 23:59 (*1) Y ALL
+36 Clock 4 day set for on CLK.4.D.on INT R/W 0 1 31 Y ALL
+37 Clock 4 month set for on CLK.4.M.on INT R/W 0 1 12 Y ALL
+38 Clock 4 hour set for off CLK.4.H.off INT R/W 0 00:00 23:59 (*1) Y ALL
+39 Clock 4 day set for off CLK.4.D.off INT R/W 0 1 31 Y ALL
+40 Clock 4 month set for off CLK.4.M.off INT R/W 0 1 12 Y ALL
+41 Clock set year Clk.Set.Y INT R/W 0 0 99 Y ALL
+42 Clock set month Clk.Set.M INT R/W 0 1 12 Y ALL
+43 Clock set day Clk.Set.D INT R/W 0 1 31 Y ALL
+44 Clock set hour Clk.Set.H INT R/W 0 00 23 Y ALL
+45 Clock set minute Clk.Set.m INT R/W 0 00 59 Y ALL
+46 Clock set day of week Clk.Set.W INT R/W 0 1 7 (*2) Y ALL
+47 Clock set holiday day INT R/W 0 1 7 (*2) Y ALL
+48 Clock set before holiday day INT R/W 0 1 7 (*2) Y ALL

Notes:
(*1) MSByte = hour, LSByte= minutes
(*2) 1= Sunday
(*3) 1= Sunday, 7=Saturday, 8=all days except holidays, 9=all days except holidays and half holidays, 10=all days

KJA00301G _TH_CanBus_Series_user version_R5.doc 4/7


TH Offset 2 table :
Register Description HMI-Ref. Type Mode Dec. Min Max Eng. Note WF Bios Compliance
N° (dec) Points Units Ready >=FW device
+0 Device ID ID INT R 0 1 999 ALL
+1 Device configuration 1 &Hex R 0
b0: clock enabled 0(off) 1(on) ALL
b1: return temp. probe enabled P_02 0(off) 1(on) ALL
b2: pump mode 0 (direct) 1 (reverse)
b3: flow meter card ready 0(off) 1(on) ALL
b4: mould temp. probe enabled AI_03 0(off) 1(on) ALL
b5: pressure probe enabled AI_04 0(off) 1(on) ALL
b6:DO_01 mode (*1)
b7
b8: actual process probe (*2)
b9:
b10:
b11:
b12:
b13:
b14:
b15:
+2 Device configuration 2 &Hex R 0

Note:
(*1): b6 b7=&H00 -> off , b6 b7=&H10 -> mould discharge , b6 b7=&H01 -> auxiliary pressurization

(*2): b8 b9=&H00 -> delivery, b8 b9=&H10 -> return , b8 b9=&H01 -> mould

KJA00301G _TH_CanBus_Series_user version_R5.doc 5/7


TH Offset 2 table (cont’):
Register Description HMI- Type Mode Dec. Min Max Eng. Note WF Bios Compliance
N° (dec) Ref. Points Units Ready >=FW device
+3 Shut down alarms &Hex R 0 ALL
b0: pump overload A_04 0(off) 1(on) ALL
b1: high fluid leakage A_06 0(off) 1(on) ALL
b2: frequent fluid leakage A_07 0(off) 1(on) ALL
b3: delivery probe failure A_20 0(off) 1(on) ALL
b4: return probe failure A_21 0(off) 1(on) ALL
b5: analogic input 3 failure A_22 0(off) 1(on) ALL
b6: cooling not reach A_32 0(off) 1(on) ALL
b7:
b8:
b9:
b10:
b11:
b12:
b13:
b14:
b15:
+4 warning alarms &Hex R 0 ALL
b0: high deviation A_02 0(off) 1(on) ALL
b1: low deviation A_03 0(off) 1(on) ALL
b2: process overtemperature A_05 0(off) 1(on) ALL
b3: delivery probe failure A_20 0(off) 1(on) ALL
b4: return probe failure A_21 0(off) 1(on) ALL
b5: analogic input 3 failure A_22 0(off) 1(on) ALL
b6: process heaters fault A_31 0(off) 1(on) ALL
b7: low flow rate A_33 0(off) 1(on) ALL
b8: flow probe fault A_34 0(off) 1(on) ALL
b9:
b10:
b11:
b12:
b13:
b14:
b15:

KJA00301G _TH_CanBus_Series_user version_R5.doc 6/7


TH Offset 2 table (cont’):
Register Description HMI-Ref. Type Mode Dec. Min Max Eng. Note WF Bios Compliance
N° (dec) Points Units Ready >=FW device
+5 Shut down alarms &Hex R 0
+6 warning alarms &Hex R 0
+7 Device status &Hex R 0 ALL
b0: cumulative OR shutdown alarms 0(off) 1(on) ALL
b1: cumulative OR warning alarms 0(off) 1(on) ALL
b2: device on (running) 0(off) 1(on) ALL
b3: mould discharge/ pressurization DO-01 0(off) 1(on) ALL
b4: fluid load valve DO-05 0(off) 1(on) ALL
b5: vent air valve DO-06 0(off) 1(on) ALL
b6: pump on (direct) DO-02 0(off) 1(on) ALL
b7: pump on (reverse) DO-03 0(off) 1(on) ALL
b8:pressur. Cycle (*1) ALL
b9:
b10:device in cooling stop 0(off) 1(on) ALL
b11: mould discharge 0(off) 1(on) ALL
b12:
b13:
b14:
b15:
+8
+9 Eng Units UM INT R 0 0(°C) 1(°F) ALL
+10 delivery temperature AI_01 INT R 1 0.0/32.0 250.0/482.0 °C/°F ALL
+11 Return temperature AI_02 INT R 1 0.0/32.0 250.0/482.0 °C/°F ALL
+12 Mould temperature AI_03/04 INT R 1 0.0/32.0 250.0/482.0 °C/°F ALL
+13 Mould pressure AI_04 INT R 0 -9999 +9999 kPa ALL
+14 Running hours INT R 0 0 9999 H ALL
+15 Heating power rH/A INT R 0 -100 100 % ALL
+16 Delivery pressure AI_11 INT R 0 -9999 +9999 kPa ALL
+17 Return pressure AI_12 INT R 0 -9999 +9999 kPa ALL
+18 Flow rate INT R 1 0.0 999.9 l/min ALL
+19 Max set point (normal pump mode) INT R 1 0.0/32.0 250.0/482.0 °C/°F ALL
+20 Max set point (reverse pump mode) INT R 1 0.0/32.0 250.0/482.0 °C/°F ALL

Note:
(*1): b8 b9=&H00 -> disable , b8 b9=&H10 -> on , b8 b9=&H01 -> off

KJA00301G _TH_CanBus_Series_user version_R5.doc 7/7