TRANSCO B.O.Q.

ITEMS FOR THE PROJECT CONTRACT N-18564/A


FINAL JOINT MEASUREMENT FOR HAND OVER (WR# PUMPING STATION) DATE: 29/03/2023
MAXIMO ID : NW-LIWA-02 NO. 008/2023
REF. JOINT JOINT
BOQ
LINE DESCRIPTION UNIT QTY UNIT PRICE TOTAL 5% VAT REMARK/LOCATION MEASUREMENT MEASUREMENT
REF. NO.
NO. DONE BY- JEMC DONE BY-TRANSCO
LOT -2B ADF - Region Locations - Pumping Stations:Maintenance of
631 2B
Lightning and Small Power Works

Replace the defected discharge METAL HALIDE 250/150W lamps. (Location:


636 2B.5 NO 9 192.5000 1,732.5000 86.6250 OUTDOOR LIGHT(03) , PUMP HALL WEST(06).
Street light, Elevation, Transformer yard). (Ref Long Description)

Replace Magnetic ballast for METAL HALIDE 250/150W lamp.(Ref Long


637 2B.6 NO 9 242.0000 2,178.0000 108.9000 OUTDOOR LIGHT(03) , PUMP HALL WEST(06).
Description)
Replace Igniter/ HPF capacitor for METAL HALIDE 250/150W lamp. (Ref
638 2B.7 NO 18 104.5000 1,881.0000 94.0500 OUTDOOR LIGHT(06) , PUMP HALL WEST(12).
Long Description)

CONTROL ROOM (16) , KITCHEN(04) , DOSING


652 2B.21 Replace the defected Fluorescent lamps 58 w. (Ref Long Description) NO 98 44.0000 4,312.0000 215.6000 PUMP ROOM (10) , DOSING PUMP HALL (08) ,
PUMP HALL EAST (36) , PUMP HALL WEST (24) .

CONTROL ROOM (07) , DOSING PUMP HALL


653 2B.22 Replace Magnetic Ballast for Fluorescent lamps 58 w. (Ref Long Description) NO 13 55.0000 715.0000 35.7500
(02) , PUMP HALL EAST (04).

CONTROL ROOM (28) , KITCHEN(04) , DOSING


PUMP ROOM (10) , DOSING PUMP HALL (08) ,
Replace Starter/ HPF capacitor for Fluorescent lamps 58 w. (Ref Long
654 2B.23 NO 122 11.0000 1,342.0000 67.1000 PUMP HALL EAST (36) , PUMP HALL WEST (25) ,
Description)
CARVAN-1(02) , CARVAN-2(02) , CARVAN-3(02) ,
SECURITY ROOM(03) , OPERATOR ROOM (02).

CONTROL ROOM (12) , STORE (02) , PUMP HALL


WEST(01) , GARGING ROOM(01) , BATTERY
ROOM (01) , OFFICE ROOM (06) , CARVAN-1(02)
659 2B.28 Replace the defected Fluorescent lamps 36 w. (Ref Long Description) NO 38 33.0000 1,254.0000 62.7000
, CARVAN-2(02) , CARVAN-3(02) , SECURITY
ROOM(03) , OPERATOR ROOM (02),
CHILORATION ROOM (04) .
CONTROL ROOM (01) , CARVAN -01 (02) ,
660 2B.29 Replace Magnetic Ballast for Fluorescent lamps 36 w. (Ref Long Description) NO 5 55.0000 275.0000 13.7500
CARVAN -02(02).
Replace Electronic Ballast for Fluorescent lamps 36 w. (Ref Long
662 2B.31 NO 1 165.0000 165.0000 8.2500 CONTROL ROOM (01) .
Description)
663 2B.32 Replace the defected Fluorescent lamps 18 w. (Ref Long Description) NO 2 22.0000 44.0000 2.2000 TOILET (02).
Replace the defected Fluorescent-FLC lamps 18/26 w. (Ref Long
667 2B.36 NO 1 44.0000 44.0000 2.2000 SECURITY ROOM(01).
Description)
668 2B.37 Replace Ballast for Fluorescent-FLC lamps 18/26 w. (Ref Long Description) NO 1 44.0000 44.0000 2.2000 SECURITY ROOM(01).

Replace the defected/broken existing light fitting, for the industrial light CONTROL ROOM (02) , PUMP HALL WEST (02) ,
682 2B.51 fittings 2x58w, FL IP 65 including with electronic ballast. (Ref Long NO 8 385.0000 3,080.0000 154.0000 DOSING PUMP ROOM (02) , DOSING PUMP
Description) HALL (02).
Replace the defected/broken existing light fittings for the industrial light
CARVAN-02(01) , CARVAN -3(01) , SECURITY
684 2B.53 fittings 2x36w, FL IP 65 including with electronic ballast. (Ref Long NO 6 330.0000 1,980.0000 99.0000
ROOM (02) , OPERATOR ROOM (02) .
Description)
Replace the defected/broken existing light fittings for the industrial light CONTROL ROOM OUT DOOR LIGTHING (10),
693 2B.62 NO 22 462.0000 10,164.0000 508.2000
fittings 70w, FL IP 65. (Ref Long Description) CARAVANS OUT (12).
Supply and Installation of LED Flood Light 100 Watt, IP 65 (Ref Long CONTROL ROOM OUT DOOR LIGTHING (02),
699 2B.68 NO 21 1,980.0000 41,580.0000 2,079.0000
Description) STREET LIGTH(19).

Supply and installation 7" round panel Ceiling LED 15W Light, IP65 (Ref Long CARVAN-01(02) , CARVAN -02(02), CARAVAN-
707 2B.76 NO 7 594.0000 4,158.0000 207.9000
Description) 03(02), CARAVAN-04(01).
Supply and installation of 5 feet Batten 45W LED Light fitting, IP65 (Ref Long CONTROL ROOM OUT DOOR (02), SECURITY
708 2B.77 NO 4 594.0000 2,376.0000 118.8000
Description) ROOM (01) , OPERATOR ROOM (01).

717 2B.86 Supply IP55/IP-56 Switch (1-Way 1-Gang ) Type. (Ref Long Description) NO 1 132.0000 132.0000 6.6000 PUMP HALL WEST (01).

Supply & installation of exit emergency light fitting with battery


725 2B.94 NO 8 302.5000 2,420.0000 121.0000 PUMP HALL WEST (02) , DOSING ROOM (06) .
operated.(Ref Long Description)
735 2B.104 Replace the defected MCB 10-40 A circuit breaker. (Ref Long Description) NO 3 440.0000 1,320.0000 66.0000 STREET LIGTH(03).

750 2B.119 Replace the defected wires 1.5 - 10 mm2. (Ref Long Description) METER 60 11.0000 660.0000 33.0000 STREET LIGTH(60).

TOTAL AMOUNT FOR BOQ ITEMS AED 81,856.50 4,092.8250

TOTAL AMOUNT FOR BOQ ITEMS WITH VAT IN AED 85,949.3250

JUPITER ELECTRO MECHANICAL CONTRACTING LLC ABU DHABI TRANSMISSION & DESPATCH COMPANY (TRANSCO)

PROJECT ENGINEER NAME : TRANSCO ENGINEER NAME : ENGR.FAHIM AHMED ABDUL LATIF / ENGR.MOHSIN ALAM

SIGNATURE : SIGNATURE :

DATE : 29/03/2023 DATE :