Pipe From Distribution chamber for PSTS To PST

Q Average 18000 m3/day


Q Average for each pst tank 6000 m3/day
Peak factor 2.5
15000 m3/day
Q Peak
0.17 m3/s
Assume D 500 mm
Aera of Pipe 0.196 m2
V 0.88 m/s

Pipe From 1 PST To Complete Mix Tanks

Q Average 6000 m3/day


Peak factor 2.5
15000 m3/day
Q Peak
0.17 m3/s
Assume D 500 mm
Aera of Pipe 0.196 m2
V 0.88 m/s

Pipe From Complete Mix Tanks To 1 FST

Q Average /3 6000 m3/day


Peak factor 2.5
15000 m3/day
Q Peak
0.17 m3/s
6000 m3/day
Qr/3
0.07 m3/s
Q Peak +Qr 0.24 m3/s
Assume D 600 mm
Aera of Pipe 0.283 m2
V 0.86 m/s
Pipe from one FST to Chlorine Contact Tank
Q Average 6000 m3/day
Peak factor 2.5
15000 m3/day
Q Peak
0.17 m3/s
Assume D 500 mm
Aera of Pipe 0.196 m2
V 0.88 m/s
Collecting Pipe from two FSTs to Chlorine Contact Tank

Q Average 12000 m3/day


Peak factor 2.5
30000 m3/day
Q Peak
0.35 m3/s
Assume D 600 mm
Aera of Pipe 0.283 m2
V 1.23 m/s
Collecting Pipe from three FST to Chlorine Contact Tank
Q Average 18000 m3/day
Peak factor 2.5
45000 m3/day
Q Peak
0.52 m3/s
Assume D 700 mm
Aera of Pipe 0.385 m2
V 1.35 m/s
Pipe From Chlorine Contact Tank to Drainge
Q Average 18000 m3/day
Peak factor 1.5
27000 m3/day
Q Peak
0.31 m3/s
Assume D 600 mm
Aera of Pipe 0.283 m2
V 1.11 m/s
Pipe for Energency
Q Average 18000 m3/day
Peak factor 1.5
27000 m3/day
Q Peak
0.31 m3/s
Assume D 600 mm
Aera of Pipe 0.283 m2
V 1.11 m/s