FOR C1 FOR C2

0.3m

6-Ø16mm Ø10mm TIES 0.2m


VERT. @ .20m O.C.
Ø10mm TIES
BARS 6-Ø16mm
@ .20m O.C.
VERT.
1.0m
FFL BARS FFL
0.9m

0.3m
100mm SLAB ON GRADE

0.3m
100mm SLAB ON GRADE
100mm GRAVEL BEDDING
0.3m NGL EARTHFILL EARTHFILL 0.2m 100mm GRAVEL BEDDING NGL EARTHFILL

1.2m

1.2m

2.0m
2.0m

1.0m
Ø10mm TIES
0.3m
1.0m

10mmØ TIES Ø16mm @ .20m O.C. Ø16mm


@ .20m O.C.

0.3m
BARS BARS
BOTHWAYS

0.3m
BOTHWAYS

0.4m

0.35m
6-16mmØ 100mm GRAVEL BEDDING
6-Ø16mm
VERT. 100mm GRAVEL BEDDING
VERT. 0.9m
BARS 1.0m BARS

0.1m
PLAN SECTION PLAN SECTION

SCHEDULE OF COLUMN
DIMENSIONS (mm) REINFORCEMENT(mm)
COLUMN
DESIGN W L TOTAL
TIE BARS
VERT. REMARKS S PLANS DETAILS AND SCHEDULE
WIDTH LENGTH HEIGHT BARS S C A L E : 1 : 1 0 0
F1 300 300 7900 10mmØ 6-16mmØ ISOLATED
6
F2 200 300 7900 10mmØ 6-16mmØ ISOLATED

DESIGNED BY: INSTRUCTOR: PROJECT TITLE: PAGE CONTENT: PAGE NO.

A TWO-STOREY COMMERCIAL BUILDING S


ALINGIG, RENZ A. ENGR. MELANIE ROSE P. PASCUA PLANS DETAILS AND SCHEDULES
6
CATABLAN URDANETA CITY, PANGASINAN