No Check List Items REMARK
Y N
A) PLANNING
1 Are personnel involved in confined space/ inert entry trained and competent?
Are physical (PIC), electrical isolation certificates (EIC) and spading/blinding list attached with
3
the permit?
4 Are there any other incompatible works nearby? i.e. Radiation, exhaust fume etc.
5 Are the workers certified medically fit for confined space and inert entry work?
6 Are the JSA and ERP attached with the confined space certificate?
For the inert entry, are the following personnel available at site?
1. Work Supervisor/Leader
7
2. Stand-By Person/Rescue for Inert Confined Space
3. Life Support equipment operator
8 Has an initial gas test been done and as per the frequency prescribed in PTW?
11 Have JSA and emergency response plan been briefed to the workers?
2 Is the life support operator in continuous communication with inert entry workers?
NOTE
For entry condition of respirable atmosphere:
1. O2 content shall be at a minimum of 20% and maximum of 21% by volume.
2. LEL less than 1% by volume AND;
3. Toxic vapours : not greater than 50% of the PEL
Prepared By : Reviewed By :
HSE TIER 1 CHECKLIST
SAFETY: CONTROL OF IGNITION SOURCES
NO WORK IS SO URGENT THAT WE CANNOT TAKE TIME TO DO IT SAFELY
Date:
Lead Auditor:
Auditor
Members:
Projects:
Compliance
No Check List Items REMARK
Y N
A) IDENTIFICATION & CONTROL OF IGNITION SOURCES
1 Are all relevant personnel trained on control of ignition source procedure?
Has intentional release of flammable been controlled in the vicinity of known ignition source?
3
e.g. line breaking, draining, sampling, line flushing etc
B) OPEN FLAMES
1 Is nitrogen/ CO2 snuffing available at local vent for extinguishing of fire?
E) HOT WORK
1 Are all hot works in the area have approved hot work permits?
2 Is the negative point placed nearest possible to the welding point? (to prevent arcing)
Is static discharge point available at the staircases of highly flammable products tank?
3 e.g. toluene, Jet A1, gasoline
Is the practice of spray loading prohibited/controlled? (for top loading of products, initial fill-up
4
of empty tank)
5 Is the flow rate of products controlled? (to prevent statics build up or two-phase flow)
3 Is inspection tag available and valid for hand tools and equipments?
Prepared By : Reviewed By :
SAFETY TIER-1 CHECKLIST: CHEMICAL HANDLING
NO WORK IS SO URGENT THAT WE CANNOT TAKE TIME TO DO IT SAFELY
Date:
Lead Auditor:
Auditor
Members:
Projects:
Compliance
No Check List Items REMARK
Y N
A) PLANNING
1 Are employees and contractors trained on chemical handling?
2 Are employees and contractors trained on proper use and maintenance of PPE issued?
9 Are the eye wash and safety shower in the work area are in good condition / functioning?
Do workers know the location of the eye wash and safety shower in vicinity of their work
10 location?
Prepared By : Reviewed By :
HSE TIER 1 CHECKLIST
SAFETY: ENERGY ISOLATION
NO WORK IS SO URGENT THAT WE CANNOT TAKE TIME TO DO IT SAFELY
Date:
Lead Auditor:
Auditor
Members:
Projects:
Compliance
No Check List Items REMARK
Y N
A) PLANNING
1 Are all relevant personnel trained on energy isolation procedures?
Has all energy sources been identified for the job? e.g. electrical, chemical, hydraulic,
2
pneumatic, radioactive, etc
4 Has PTW been issued for all certificates? e.g EIC, PIC
5 For confined space entry, has ‘positive isolation’ as per PTS been applied?
B) ELECTRICAL ISOLATION
1 Is operation lock & tag applied at substation?
3 Is motor control centre (MCC) racked out and locked? (for work inside substation)
C) PHYSICAL ISOLATION
1 Is equipment under maintenance has been isolated as per PIC?
4 Has the lock number and tag number been recorded in PIC?
1 Are electrical trade key and Operation group lock key placed inside the lockout box?
E) APPROVAL
1 Has EIC been completed, signed and approved?
2
Has PIC been completed, signed and approved?
F) WORK EXECUTION
1 Check validity of PTW, EIC and PIC
Check locks and tags at site and electrical substation as per PTW, EIC, PIC and isolation and
2
spading list.
H) HAND BACK
1 Has Operation verified completion of work?
Prepared By : Reviewed By :
HSE TIER 1 CHECKLIST
SAFETY: EXCAVATION
NO WORK IS SO URGENT THAT WE CANNOT TAKE TIME TO DO IT SAFELY
Date:
Lead Auditor:
Auditor
Members:
Projects:
Compliance
No Check List Items REMARK
Y N
A) PLANNING
1 Are valid excavation certificate and PTW available and displayed at site?
2 Is this work declared as confined space entry (if more than 1.5 meter)?
4 Is the person in-charge of the excavation work well trained and competent?
Is daily inspection of excavation site conducted by the AAR, RAR and WL to ensure no change in
5 conditions before the start of work
7 Are high visibility clothing provided and worn by all workers exposed to high traffic flow
Has a warning system been established and utilised when mobile equipment is operating near
8 the edge of the excavation.
9 Has the local utility agency/companies contacted as part of the work plan (if necessary)
Has atmosphere within the excavation tested for oxygen deficiency, combustible or other
2 harmful contaminant
3 Are ladders used in excavations secured and extended 1.0 meter above the edge of the trench?
4 Are spoils, materials, and equipment set back at least 0.5 meter from the edge of the
excavation?
5 Are hard barriers and hazard lights (at night) provided for excavation sites in public areas to
prevent fall.
6 Have precautions been taken to protect workers from the accumulation of water.
10 Are rescue equipment, such as breathing apparatus, safety harness and lifeline, and/or basket
stretcher readily available where hazardous atmospheres could or do exist.
Prepared By : Reviewed By :
HSE TIER 1 CHECKLIST
SAFETY: HYDROJETTING
NO WORK IS SO URGENT THAT WE CANNOT TAKE TIME TO DO IT SAFELY
Date:
Lead Auditor:
Auditor
Members:
Projects:
Compliance
No Check List Items REMARK
Y N
A) PLANNING
1 Are Hydro-jet operators trained and competent for the job?
Is the operator equipped with mandatory PPE for hydro jetting i.e. face shield, rubber safety
3
boots, water proof protective suit, ear muff/plug, long rubber gloves, safety helmet etc.?
Is the site selected for equipment setup/location out of major personnel traffic area and is a
9
safe distance from operating equipment.
Is barricade tape extended around the hydro-jetting equipment as required for personnel and
10
operation safety?
14 Are all hoses properly protected and barricaded and do not cause tripping hazard.
17 Is the working platform properly erected ( suitable for hydro jetting activities)
Are the arrangements in place to ensure that the material being blasted is contained and
19 disposed properly?
20 Is proper containment available to prevent diesel or engine oil spillage during top up and
maintenance activities?
22 Are all hoses and fittings of the correct pressure rating and in good condition
24 Are all hoses and fitting inspected as per recognised international and manufacturer’s standards
25 Are hoses fitted with safety bridges (restraining devices i.e. whipped check) across couplings
and hoses.
Is the equipment equipped with safety devices i.e. "dead man" switch, safety relief valve,
27
rupture disc
Prepared By : Reviewed By :
SAFETY TIER-1 CHECKLIST: LIFTING
NO WORK IS SO URGENT THAT WE CANNOT TAKE TIME TO DO IT SAFELY
Date:
Lead Auditor:
Auditor
Members:
Projects:
Compliance
No Check List Items REMARKS
Y N
A) PLANNING
Are all persons involved in planning, inspection and performing lifting (Crane inspector,
1 Signalman, rigger, lifting coordinator, crane operator, AA) and maintaining lifting equipment
trained and competent for their roles?
3 Are valid crane lifting certificate, JSA and risk assessment attached with Permit to Work (PTW)
Has the critical lift been identified i.e. more than 85% of Safe Working Load (SWL) of the crane
4
chart capacity and multiple crane lift
Critical Lifting: Is the lifting plan, load calculations, shackle capacity, sling capacity, spreader
5 beam capacity are incorporated with the lifting certificate and verified by competent
personnel?
2 Is the crane on solid footing and level ground before making a lift (out rigger fully extended)
3 Have the lifting area being barricaded and cleared from unauthorised personnel
4 Is night lifting authorised with additional control measures in place i.e. JSA, sufficient lighting.
Are the lifting activities allowed during bad weather condition (i.e. heavy rain, strong wind,
5 lightning, snowing)
Have the crane operator and rigger ensure that no personnel walks under the load and boom
8 during lifting
9 Is there any sharp edges that can damage the slings during lift
10 Has the crane operator ensure that the load not being suspended when leaving the crane
unattended
Does the crane operator or person in-charge (PIC) ensure that there is no personnel riding on
11
the load
Prepared By : Reviewed By :
SAFETY TIER-1 CHECKLIST: PTW
NO WORK IS SO URGENT THAT WE CANNOT TAKE TIME TO DO IT SAFELY
Date:
Lead Auditor:
Auditor
Members:
Projects:
Compliance
No Check List Items REMARK
Y N
A) ADMINISTRATION & ORGANIZATION
1 Is the form properly filled-up and signed?
2 Is the list of PTW authorized signatories updated and displayed at the PTW Office/Station?
Copies of PTW available : Original (Worksite), Copy 1 (Control Room/PTW Office/Station), Copy
3 2 (RA)
2 Have all hazards associated with the work been identified and necessary precautions specified ?
Are the supporting certificates, JHA/JSA and relevant drawings for the work attached with the
4 PTW?
Has revalidation been carried out during shift change or if there is any change to the conditions
7 of the permit?
8 Has the work been hand back and PTW signed off by RA and AA upon completion of the job?
C) HOT WORK
Are incompatible activities e.g. atmospheric venting, draining, line breaking, sampling been
1
prohibited at adjacent areas?
2 Are firefighting equipment e.g. fire extinguisher, fire blanket available and working?
D) GAS TESTING
1 Are the AGTs certified?
Is the gas testing frequency specified on the PTW and carried out i.e. Continuous or at specified
2 intervals?
NOTE: AA (Approving Authority), AAR (Approving Authority Representative), RA (Receiving, authority) , RAR (Receiving Authority Representative), WS (Work Supervisor), WL (Work Leader)
Prepared By : Reviewed By :
HSE TIER 1 CHECKLIST
SAFETY: SAFETY SYSTEM BYPASS / OVERRIDE (SSB/O)
NO WORK IS SO URGENT THAT WE CANNOT TAKE TIME TO DO IT SAFELY
Date:
Lead Auditor:
Auditor
Members:
Projects:
Compliance
No Check List Items REMARK
Y N
A) REQUEST FOR SAFETY SYSTEM BYPASS AND OVERRIDE
1 Are detailed procedures available for specific SSB/O execution?
B) RISK ASSESSMENT
1 Has risk assessment been carried out by relevant involved party?
E) APPROVAL
1 Is SSB/O approved by appropriate AA?
F) WORK EXECUTION
1 Is the SSB/O certificate still valid?
Are the SSB/O Certificates revalidated every 7 days and renewed after 3 months when required
2
for an extended period?
3 Is SSB/O status closely tracked, closed and updated in the log book or SSB/O Status Board?
4 Has all SSB/O status communicated to all shift personnel and status reported during shift
handover?
H) HAND BACK
1 Has the safety system returned to its original state?
2 Has the SSB/O been hand back and signed off by RA and AA?
NOTE: Safety Integrity Level (SIL) 4 ESD loops shall not be bypassed under any operational conditions
Prepared By : Reviewed By :
SAFETY TIER-1 CHECKLIST: SCAFFOLDING
NO WORK IS SO URGENT THAT WE CANNOT TAKE TIME TO DO IT SAFELY
Date:
Lead Auditor:
Auditor
Members:
Projects:
Compliance
No Check List Items REMARK
Y N
A) ADMINISTRATION & ORGANIZATION
For specialised scaffoldings (e.g Hung/Suspended, load bearing, tubular above 40 meter),
1
Designed and approved by competent person or Professional Engineer and drawing available
2 Levels of competency of workers meet DOSH requirements. (eg. Level 2 or advanced scaffolder)
3 Are inspection tags available and periodically revalidated (weekly or other specified interval)?
5 Are the scaffolding re-inspected after been subjected to severe weather conditions e.g. storm?
3 Are proper sole plates used for uneven surfaces? e.g. soft soil, grating
Are barricade and warning signs installed to protect against vehicle movement and crane
5 operations?
Are the tubes, fitting and floorboards free from signs of damage or deterioration e.g. rusting,
6 sufficient thickness, not split, rotten?
7 Are the working platforms free from obstruction, loose objects, debris and tripping hazards?
D) SUPPORTING STRUCTURES & ANCHORING POINTS (ie: plant structures where scaffoldings are secured or anchored to)
2 Plant equipment e.g. pipings, cable trays etc are not used as supporting structure
Prepared By : Reviewed By :
HSE TIER 1 CHECKLIST
SAFETY: WORKING AT HEIGHT
NO WORK IS SO URGENT THAT WE CANNOT TAKE TIME TO DO IT SAFELY
Date:
Lead Auditor:
Auditor
Members:
Projects:
Compliance
No Check List Items REMARK
Y N
A) GENERAL
1 Are hazards associated with working at height are specified in the PTW and JHA/JSA?
2 Are tools and equipment safely stored and secured to prevent fall from height or trip hazard?
3 Has working at height equipment (e.g. ladder, mobile platform) been inspected before use?
4 Is ground area is properly barricaded and warning signs displayed to protect personnel from
falling objects
Does personnel use 100% tie-off with full body harness when working at height with risk of fall
5
e.g. working edge of platform, during installation/dismantling of scaffolding?
2 Have users of safety harness attended training on safe use of safety harness?
C) LADDER
1 Is ladder rested on level and stable ground?
D) WORKING ON ROOF
1 Is scaffold used for all roof access and egress (use of ladder is prohibited)?
2 Are rescue plan and equipment e.g. safety line, ladder, lifebuoy available?
F) ROPE ACCESS/ABSEILING
1 Is the Team Leader certified to IRATA (International Rope Access Training Association) Level 3
Technician or equivalent
Prepared By : Reviewed By :