HFED 061A XX
HFED 101A XX
HFED 201A XX
HFED 102A XX
HFED 202A XX
FUNCTIONNAL INSTRUCTIONS

INDUSTRELEC Le 29/08/2005
Notice four HFED Anglais.DOC Page 1
CONTENTS

I. Using the control panel Page 4


1.1. Preparing the oven for service Page 4
1.2. Shutting down the oven Page 5
1.3. Cleaning of the oven Page 5
1.4. Display panel and setting Page 6
1.5. Specials functions Page 8

II. Settings : Page 10

III. Particularities of operation : Page 12


3.1. Water injection Page 12
3.2. Regulation of the heating Page 13
3.3. Management of the static contact cooling Page 14
3.4. Scrolling of the numeric displays Page 14
3.5. Connexion of device to the systems of optimization of energy Page 14
3.6. Turbine stops if the door is opened Page 14
3.7. Cleaning’s program Page 15
3.8. Spout control Page 17

IV. Notifying and handling defects : Page 18


4.0 Over-heating components Page 19
4.1. Over-heating cooking cavity Page 19
4.2.
4.3. Temperature probe on cooking cavity Page 19
4.4.
4.5.
4.6.
4.7. Core temperature probe Page 20
4.8. the turbines are controlled on the power supply board Page 20
4.9.
4.A. Power cut of the heating Page 20
4.b. Washing defect Page 20

V. Diagnostics Page 21

VI. Diagrams and technical documentation Page 23

Notice four HFED Anglais.DOC Page 2


PLASTRON A4

Notice four HFED Anglais.DOC Page 3


I. Using the control panel :

1.1. Preparing the oven for service :

For activate a mode, used the rotative switch

- For each mode, the display panel shows the temperature setting made during configuration for five
seconds, then shows the temperature inside the oven.

- The button start stop begins or stops the cooking

If the oven door is closed :

• The light inside cavity is activate

• The choosen mode is ON

Notice four HFED Anglais.DOC Page 4


1.2. Shutting down the oven :

- Positioning the rotative switch on

The displays are desactivated.

The components fans are desactivated.

1.3. Cleaning of the oven :

- Positioning the rotative switch on

- With the keys and , choose :

1 to 8 = the automatic cleaning program which carry the washing cycling from 1 to 8

0= the program of manual cleaning for which after a 7 minutes of pre-wash in steam
mode, the buzzer is activated to indicate to the user that it must spray the cleaning
product in the cooking cavity and close again the door to finish the washing/rinsing
cycle (washing cycles details page 15 and 16)

the time display indicate:


- The duration of the chosen washing procedure
- Press START to start this program (you can stop it when you want with the stop)

Be careful : In case of defect or voluntary stop during washing (mainly lack of water), this defect
indicates that it necessary to manually rinse the cooking cavity before using the oven.

Notice four HFED Anglais.DOC Page 5


1.4. display panel and setting :

The buttons to the right of the display panel are associated


with the pictograms shown in the display panel, and each pictogram
corresponds to an indicator (temperature, time, etc.).

Each indicator displays a setting or a value measured


inside the oven.

In temperature display, the lighting point in right top indicate


the heating request.

To change a setting, press the button located at the right of chosen display,

a lighting point blinking in left bottom of this display to indicate that

you can make changes the set point with the buttons

Before the start :

- the displayed temperature is the temperature of cooking cavity

- the clock indicate the manual mode

or the programmed time

After the start :

- The displayed temperature is the temperature of cooking cavity


- The clock indicate the remaining time to finish the cooking

During the cooking, settings can be recalled and changed

Notice four HFED Anglais.DOC Page 6


If you wish to work in Manual mode, move the cooking time

setting to obtain

To cool the oven, positioonning the rotative switch on cooling mode.

The cooling symbol appears

You can choose a temperature (minimum of 30°C) and press the start

Water injections with the moving turbines will then cool the cooking cavity.

Notice four HFED Anglais.DOC Page 7


1.5. Special functions :

Humidity quantity in cavity :

Activate the key to choose a + or – important proportioning


(3 leds lighted = maxi proportioning)

10 % Led EAA = Electromagnetic valve activated 1 sec by 20


20 % Led DAA = Electromagnetic valve activated 1 sec by 10
40 % Led DEA = Electromagnetic valve activated 1 sec by 5
50 % Led DDA = Electromagnetic valve activated 1 sec by 4
70 % Led DDE = Electromagnetic valve activated 1 sec by 3
100 % Led DDD = Electromagnetic valve activated 1 sec by 2

water injection :

Only in convection mode, if oven is on, press this button to inject


water into the cooking cavity.

Spout :

In convection mode, activate this key for choose the open or close
position of spout (a lighted led indicate this position)

Notice four HFED Anglais.DOC Page 8


Core probe

To run this function , press the button to the right of time displays for 5 seconds. The temperature setting
(from 20°C to 99°C) is displayed for 5 seconds.

You can change this setting with the button and

When the setting disappears, the temperature measured by the core


is displayed in its place.

(if the probe is not connected, the defect 7 appears at the right of
temperature display)

When you have pressed START, the cooking stops when the
temperature setting of the core probe has been reached.

Notice four HFED Anglais.DOC Page 9


II. Settings :

Settings are adjusted by technical services

This menu can be accessed when the oven is off

Press the following three buttons for 5 seconds :

The version program appears : 2004 12 23

year Month day

The setting menu (1 to 14) scroll through using the key

the settings parameters are numbered from 1 to 14 in time displays.

The proposal values are indicated in temperature display.

The modifications are obtained with the keys

Each modified value will be confirm by the key

To exit the menu, press the key

Notice four HFED Anglais.DOC Page 10


1 Temperature in degrees C (Celsius) or F (fahrenheit ) C or F (F)

2 Maximum Temperature 250°C to 270°C 250 to 270 (250)

3 Default set point of the convection 150 to 180 150 to 180 (180)

4 Core probe setting + or – 9°C -9 +9 (0)

5 Frequency buzzer 1 to 100 1 to 100 (25)

6 Low speed / high speed cooker hood 0 or 1 to 160 sec 0 or 1 (2)

7 Flashing light for end of cooking 0 or 1 0 or 1 (0)

8 Cooling of the condensats 1 to 20L/H 1 to 20 (5)

9 Change of rotating direction turbine 1 to 4 minutes 1 to 4 (2)

10 Slowing strength 1 to 5 1 to 5 (3)

11 Working time of the oven and counter reset 0 to 9999 0 to 9999 (0)

12 System of optimization of energy 0 or 1 (0)

13 Configuration of pump 1 to 20 (washing product) 1 to 20 (4)

14 Tests (validate with start)

Notice four HFED Anglais.DOC Page 11


III. Particularities of operation :

3.1. Water injection :

- Automatic (cooling) :

If cooling mode or steam mode is selected and cavity temperature :

- > 150 °C
Injection during 1 second every 3 seconds

- From 150° to 105°C


Continuous injection of water

- the injection of water stops when the temperature is 105°C for steam mode

- the spout is open

Notice four HFED Anglais.DOC Page 12


3.2. Regulation of the heating :

3.2.1. Convection and combination with water injection :


After the start, if the temperature of the oven is lower than 13°C (convection/combination) or 8°C (steam)
compared to the set point, the full power is activated as far as the set point.

• If the temperature falls

§ Convection mode:
25 % of power activated to the set point
50 % of power activated to the set point – 0,5°C
100 % of power activated to the set point – 2°C

§ Steam and combination mode :


50 % of power activated to the set point
100 % of power activated to the set point – 1°C

• If the temperature rises :

§ convection mode
the heating is stopped to the set point –2°C

§ Steam and combination mode :


The heating is stopped to the set point –2°C

In combination mode to the set point + 3°C when the water injection is activated, the heating is maintained
to 100 %.

If the rise of temperature in oven is more than 1°C for 2 seconds, the heating is stopped.

3.2.2. Steam with water injection :

The heating is regulated in the same conditions of combination mode with maximum set point 100°C.
The turbine is activated.
The water is injected continuously in the turbine (EV PA2).

After the steam mode choice or after door closing, the spout closes.

Notice four HFED Anglais.DOC Page 13


3.3. Management of the static contacts cooling :
As soon as a mode is selected, the cooling electromagnetic valve is activated to filling up the heater.
If the start is activated (heating on), the electromagnetic valve is activated with the following configuration
(settings from 1 to 20).

1
Config = 1 à EV = 0 5 19 sec
5

1
Config = 2 à EV = 0 5 18 sec 5

1
Config = 20 à EV = 0

A temperature probe situated on the CPU board controls the ambient temperature. If this temperature is
upper than 65°C, the heating is stopped , the defect 0 over heating components is indicated (paragraph
IV)

3.4. Scrolling of the numeric displays :


The scrolling of the numeric displays progresses to 10 units and then by 10 units at a
time, if the buttons stay pressed.

3.5. Connexion of device to the systems of optimization of energy :


- Connect the control coming from the system on the J4 connectors of CPU (free contact of
potential)
- Position the configuration 12 = 1 in order to the regulation of the oven takes into account the
control of system of optimization (if this control is to zero, the oven heating is desactivated)

Option : (for connexion to the SICOTRONIC system)

It’s possible to take an information “lit consumer” “terminal A” by connecting this information to the static
contactor L1 convection, on the one hand, and the neutral at exit of the D1 circuit breaker, on the other
hand.

3.6. Turbine stops if the door is opened :


The stop and braking system of the turbine engines is activated immediately on door opening.

Notice four HFED Anglais.DOC Page 14


3.7. Cleaning’s program :

Washing procedure

Notice four HFED Anglais.DOC Page 15


Washing procedure

Notice four HFED Anglais.DOC Page 16


3.8. Spout control :

- The spout is open : if the door is opened


- The spout is closed : in steaming and combination modes
- Spout closed = Electromagnetic valve desactivated

In each spout closing, the electrovalve of cooling water is activated during 30 seconds.

Notice four HFED Anglais.DOC Page 17


IV. Notifying and handling defects :

Some defects of operation are controlled by the electronics and visualised on the temperature screen (at
space of C or F)

These defects are numbered and if one of them appears during the operation of the oven, the
corresponding number will be displayed and blinked.

0 Over-heating electronic components and contactors


1 Over-heating of the cooking cavity
2
3 temperature probe of the cooking cavity : out of service
4
5
6
7 Core probe : out of service
8 Turbines defects
9
a Power cut of the heating

8 Washing defect

It is necessary to correct the defects if not the display of the defect will appear for each cooking
mode concerned.

If a defect appears, a message is indicated in the screen.

The message stay displayed if the concerned mode is not available : choose an other cooking
mode.

Notice four HFED Anglais.DOC Page 18


4.0. Over-heating components (defect 0) :
A probe of temperature located on the CPU board checks the temperature of the components
if it reaches 65°C, the heating of all cooking modes is stopped.
A probe of temperature measurement located near the statics contactors controls the temperature of
radiator. If this temperature reaches 55°C, the electrovalve of cooling is then activated at 100 %.
If this temperature reaches 65°C, the heating is stopped.
The defect 0 is indicated (check the water arrival).

4.1. Over-heating cooking cavity (defect 1) :


The thermostat of security positioned on the cooking cavity will open if the temperature goes over 350°C.
If it is opened, the convection heating is stopped.

If the turbine is working when the defect appears, it keeps rotating. This defect is visualised by a red led
on the convection relay-board (lighted led = OK).

4.2.

4.3. Temperature probe on cooking cavity (defect 3) :


If the probe is failing, the corresponding temperature is not anymore displayed on the screen.

The convection heating is stopped.

4.4.

4.5.

4.6.

Notice four HFED Anglais.DOC Page 19


4.7. Core temperature probe (defect 7) :
If this probe is failing, the corresponding temperature is not anymore displayed on the screen, the core
probe mode is not usable.

4.8. the turbines are controlled on the power-supply board (defect 8) :

if the intensity measure is = 0, 20 seconds after the switching on of the engine, the defect is indicated.

This defect is visualised by a led on the power-supply board (lighted led = 0K).

The convection heating is stopped.

4.9.

4.A. Power cut of the heating (defect a) :

If the oven is linked to the power controlling system and if it’s shut down by this system, the defect
appears. If the power cut disappears, the heating restart (the defect remains displayed until the reset with
the key OFF).

In all modes, the heating is stopped.

4.b. Washing defect (defect 8 ) ):

In case of defect or voluntary stop during washing (mainly lack of water), this defect
indicates that it necessary to manually rinse the cooking cavity before using the oven.

Notice four HFED Anglais.DOC Page 20


V. Diagnostics :
In case of fault of operation, the technician has disposal of the TESTS’ menu in which he can force all the
activators and visualises their actions to guide the diagnostic.

Some tests (example : command of the boiler heating) do not take into account the securities of the
functional program.
This menu of tests has to be used with care.
In order to use these tests, you need to verify if the configured parameters are conformed to the user’s.

This menu can be found at the end of the setting’s menu position 14/test by pressing the key

- The first procedure carries out a test of displays, of leds, of buzzer to visualize those.

The key activated, sends to you towards the following procedure

- The second procedure permit to test the keyboard keys and the switch. A number appears in time
screen for indicate the good functioning.

00 Position zero of switch

01 Position of switch

02 Position of switch

03 Position of switch

04 Position of switch

05 Position of switch

06
to the keys of keyboard
14

the key activated during 3 seconds sends to you towards the following
procedure.

Notice four HFED Anglais.DOC Page 21


The third procedure permit to test the inputs/outputs, this procedure is visualized

in screen

output state
input state test number
the state of input or output is indicated in screen

to activate the outputs, use the key

to change the test number, use the keys

To escape to the test procedure, activate and


0 Cooking cavity temperature
1
2 Core probe temperature
CPU 3 Components temperature
4 CPU temperature
5 Input X4.7.3 Contact door = 0 or 1 activated
6 Input P.7.4 Power cut = 0 or 1 activated
7 Input P7.5 (ANA)
Power 8 Input X573 Turbine OK = 0 or 1 activated
Supply 9 Output P4.4 Turbine (L1) = 0 or 1 activated
board 10 Output P2.5 Turbine = 0 or 1 activated
11 Output P2.3 Lighting = 0 or 1 activated
12 Input X073 Thermostat of security = 0 or 1 activated
13 Input X173
14 Output PA.3 Components fan = 0 or 1 activated
15 Output PA.0 Spout = 0 or 1 (open)
16 Output P4.5 Heating (L3) = 0 or 1 activated
17 Output P4.6 Heating (L2) = 0 or 1 activated
18 Output P4.7 Heating (L1) = 0 or 1 activated
19 Output PA.1 Cooling components = 0 or 1 activated
20 Output PA.2 Water injection = 0 or 1 activated
21 Input X273
22 Input X373
23 Output P6.6
24 Output P6.3
25 Output P6.0
26 Output P6.1
27 Output P6.2
28 Output P6.4 Arm of washing = 0 or 1 activated
29 Output P6.5 Washing product = 0 or 1 activated
Notice four HFED Anglais.DOC Page 22
VI. diagrams and technical documentation :

Notice four HFED Anglais.DOC Page 23


DISPLAY BOARD

Notice four HFED Anglais.DOC Page 24


CPU BOARD

Power cut

+ 24V Presence 5V -24V +12V


Notice four HFED Anglais.DOC Page 25
POWER SUPPLY BOARD

Oven lighting + 24V -24V

12V Oven light turbine control P4.4


P2.3

PH
speed
variation

Turbine
Information

Rotation
inversion
turbine
P2.5

-6V

lighting
fuse

11,5V~ 24V~ 24V~ 6V~ 230V~ N PH PH N N


PHT
primary
230V~