Output Ratings
Generating Set Model P230H P250HE
Prime* Standby*
380-415V, 50 Hz 230 kVA 250 kVA
184 kW 200 kW
196 kW 215.2 kW
Technical Data
Engine Make & Model Perkins 1306-E87TA300
abcde
FG Wilson (Engineering) Ltd
Old Glenarm Road, Larne, County Antrim BT40 1EJ
Northern Ireland, United Kingdom
Tel: 44 (0) 28 2826 1000 Fax: 44 (0) 28 2826 1111
www.FGWilson.com
P230H/P250HE
50 Hz n/a 53.3 (14.1) 40.0 (10.6) 26.7 (7.0) -Standby: 40.3 (1421) 51.3 (1809)
60 Hz n/a 62.1 (16.4) 46.6 (12.3) 31.1 (8.2) -Prime: 40.3 (1421) 51.3 (1809)
Exhaust Gas Temperature:°C (°F)
- Standby: 526 (979) 477 (891)
(based on diesel fuel with a specific gravity of 0.85 and
conforming to BS2869, class 2) - Prime: 526 (979) 477 (891)
2
P230H/P250HE
Motor Starting
500 470 420 560 540 345 410 380 460
Capability* kVA
Short Circuit
300 300 300 300 300 300 300 300 300
Capacity** %
Reactances:
Per Unit
Xd 2.85 3.07 3.40 2.34 2.73 4.31 3.63 3.91 3.25
X’d 0.13 0.14 0.15 0.11 0.12 0.20 0.16 0.18 0.15
X”d 0.077 0.083 0.092 0.063 0.074 0.117 0.098 0.106 0.088
3
P230H/P250HE
Technical Data
3 Phase Ratings and Performance at 50 Hz, 1500 RPM 3 Phase Ratings and Performance at 60 Hz, 1800 RPM
Model: P230H Model: P250HE Model: P230H Model: P250HE
Voltage Voltage
Prime Standby Prime Standby
kVA kW kVA kW kVA kW kVA kW
415/240 230.0 184.0 250.0 200.0 480/277 245.0 196.0 269.0 215.2
400/230 230.0 184.0 250.0 200.0 440/254 245.0 196.0 268.0 214.4
380/220 230.0 184.0 250.0 200.0 380/220 243.0 194.4 264.0 211.2
230/115 230.0 184.0 250.0 200.0 240/139 245.0 196.0 269.0 215.2
220/127 215.0 172.0 240.0 192.0 240/120 245.0 196.0 267.0 213.6
220/110 230.0 184.0 250.0 200.0 230/115 245.0 196.0 265.0 212.0
200/115 230.0 184.0 250.0 200.0 220/127 245.0 196.0 268.0 214.4
220/110 243.0 194.4 264.0 211.2
208/120 245.0 196.0 267.0 213.6
Definitions
Standby Rating Prime Rating Standard Reference Conditions
These ratings are applicable for supplying These ratings are applicable for supplying Note: Standard reference conditions 27˚C
continuous electrical power (at variable load) continuous electrical power (at variable load) (80˚F) Air Inlet Temp, 152.4m (500ft) A.S.L.
in the event of a utility power failure. No in lieu of commercially purchased power. 60% relative humidity. All engine
overload is permitted on these ratings. The There is no limitation to the annual hours of performance data based on the above
alternator on this model is peak continuous operation and this model can supply 10% mentioned maximum continuous ratings. Fuel
rated (as defined in ISO8528-3). overload power for 1 hour in 12 hours. consumption data at full load with diesel fuel
with specific gravity of 0.85 and conforming to
BS2869: 1998, Class A2.
L W
General Data
Documents Generating Set Standards Warranty
A full set of operation and maintenance The equipment meets the following standards: All equipment is guaranteed for a period of 12
manuals, circuit wiring diagrams, and BS5000, ISO 8528, months from date of commissioning or 18
commissioning/fault finding instruction ISO 3406, IEC 60034, VDE 0530, NEMA months from shipping, whichever occurs first.
leaflets. MG-1.22. Extended warranty terms are available.
275-329 In line with our policy of continuous product development, we reserve the right to change specification without notice. P230H-P250HE/TECHDATA/FGW/0401