Download as pdf or txt
Download as pdf or txt
You are on page 1of 1

PRODUCED BY AN AUTODESK STUDENT VERSION

PRODUCED BY AN AUTODESK STUDENT VERSION


PRODUCED BY AN AUTODESK STUDENT VERSION

Sock away
Septic Tank SC 1:25

A A

600

700
Ø100 vint pipe

in let pipe
600
700

500 500
4000

5000

2997.3329
SOCK AWAY SC 1:25

A
B
A SOCK AWAY SC 1:25

B 4000 Ø100 vint pipe


500 500
A D A

100
50 600 50

TOP PLAN

A' A B C C' NOTICE


PARKING IS NOT ALLOWED
400

USE CONCRETE QUALITY C-20

Stone masonery

1 489

D1
D1 SECTION A-A SC 1:50

Septic Tank SC 1:25


D1 D1 Septic Tank SC 1:25

BOTTOM PLAN
W2
D1 Gentile's toilet Ladies toilet D1 2000
W2 Area =22.35m² Area =22.35m² A
A
Dia 8mm c/c 250mm

D1 D1 TOP Reinforcement

TOP PLAN 4000

NOTICE
LEGEND
D1 PARKING IS NOT ALLOWED
USE CONCRETE QUALITY C-20

D1 COLD WATER SUPPLY


GATE VALVE
WASTE WATER PIPE
D2
D2 HWB--- HAND WASH BASINE
2 WC --- WATER CLOSET

140
UR----- URINAL 100 600 100
D3 D2 S1 , S2 = Ø110 UPVC STACK
D Ø8c/c200 variable

W1''' W1''' - D - = SUBSURFACE DRAINAGE PIPE 400-700

120
unisex Baby changing
Lobby A Ø8c/c200 variable

Area =3.14m² Area =3.1m² 1000

700
B Ø8c/c200 variable
Area =13.8m² SH--- SHOWER HCB Wall

50
700

R.C COVER SC 1:5

FD--- FLOOR DRAIN

D2 D2 DP--- DOWN PIPE


CP--- CATCH PIT
500 488.7902 500

488.2456
W1'' W1''
Store Janitor or shop
D4 Reception Area and D4 Area=3.6m²
Area =3.6m²
shop,Area =2.6m²
3
D2 NOTE:-
W1' W1' 1. PROVIDE 2% SLOPE FOR WASTE PIPES OF SIZE 110 MM DIA. AND 2.5% WATER DEVELOPMENT COMMISSION
SANITATION INFRASTRUCTURE STUDY,DESIGN AND
CONSTRUCTION SUPERVISION DIRECTORATE
FOR PIPES LESS THAN DIA .110MM ON THE GROUND INSTALLATIONS
2. PLACE THE WASTE OUTLET CONTRUCTOR: :DAGIMAWI MISGANAW G.C

3. FOR HAND WASH BASIN AND URINALS AT 410 - 450 MM FFL (PIPE CENTER )
4. FOR WATER CLOSET AT 220MM (PIPE CENTER LINE) Project:
STUDY AND DESIGN OF JIGJIGA MODEREN PUBLIC TOILET

5. PLACE THE BRANCH COLD WATER LINE 300 MM FFL


Title:
6. PLACE THE WATER SUPPLY INLET TO THE HWB AT 600MM FFL SANITARY ASBUILT DRAWING

7. PLACE THE RIM (TOP) OF HWB AT 800MM FFL DRAWN


DAGIMAWI MISGANAW
DATE December 2022
8. PROVIDE 1.5% SLOPE FOR ALL SUSPENDED PIPES (IN THE CEILINGS) DESIGNED SCALE
Mawlid A. 1:75
CHECKED REVISION No.

APPROVED DRAWING No. ST-MPT- GR - 01/14

PRODUCED BY AN AUTODESK STUDENT VERSION