Professional Documents
Culture Documents
SIE PERFOMACE Sub To Mahmoud
SIE PERFOMACE Sub To Mahmoud
IP,BP,FP v T
4
3.5
3
POWER (KW)
2.5
2
1.5
1
0.5
0
0 0.5 1 1.5
T READING (KP)
IP BP FP
2-
IP,BP,FP v N
4
3.5
3
POWER (KW)
2.5
2
1.5
1
0.5
0
1000 1170 1410 1885
N (RPM)
IP BP FP
3-
Isfc, bsfc v T
4000
3500
SFC (GM/KW.HR)
3000
2500
2000
1500
1000
500
0
0 0.5 1 1.5
T READING (KP)
Isfc bsfc
SIE Performance Test: Required Curves by applying the Runs by
equations on Excel Sheet:
4-
Isfc, bsfc v N
4000
3500
SFC (GM/KW.HR)
3000
2500
2000
1500
1000
500
0
1000 1170 1410 1885
N (RPM)
Isfc bsfc
5-
Imep, bmep v T
250
200
MEP (KPA)
150
100
50
0
0 0.5 1 1.5
T READING (KP)
Imep bmep
6-
Imep, bmep v N
250
200
MEP (KPA)
150
100
50
0
1000 1170 1410 1885
N (RPM)
Imep bmep
SIE Performance Test: Required Curves by applying the Runs by
equations on Excel Sheet:
7-
ηm, ηth-I,ηth-B,η-v v T
70
60
50
40
Η%
30
20
10
0
0 0.5 1 1.5
ηm ηth-B ηth-I ηv
T READING (KP)
8-
ηm, ηth-I,ηth-B,η-v v N
70
60
50
40
Η%
30
20
10
0
1000 1170 1410 1885
ηm ηth-B ηth-I ηv
N (RPM)
SIE Performance Test: Required Curves by applying the Runs by
equations on Excel Sheet:
Reciprocating Multistage Compressor: Required Curve, Data based on
equations on an Excel sheet
P vs M'
0.03
0.025
0.02
m' (kg/s)
0.015
0.01
0.005
0
P (bar) 0 1 1.5 2 2.5 3 3.5 4 4.5
p(bar)