Designation: E1961 − 16

Standard Practice for


Mechanized Ultrasonic Testing of Girth Welds Using Zonal
Discrimination with Focused Search Units1
This standard is issued under the fixed designation E1961; the number immediately following the designation indicates the year of
original adoption or, in the case of revision, the year of last revision. A number in parentheses indicates the year of l ast reapproval. A
superscript epsilon (´ ) indicates an editorial change since the last revision or reapproval.

1. Scope* 2.3 ASNT Standard:3


1.1 This practice covers the requirements for mechanized ASNT Practice SNT-TC-1A Personnel Qualification and
Cert ification in Nondestructive Testing
ultrasonic examination of girth welds. Evaluation is based
upon the results of mechanized u ltrasonic examination. Accep- ANSI/ASNT-CP-189 Standard for Qualification and Certifi-
tance criteria are based upon flaw limits defined by an cation of Nondestructive Testing Personnel
Engineering Crit ical Assessment (ECA) or other accept/reject 2.4 AIA Standard:
criteria defined by the Contracting Agency. NAS-410 Nondestructive Testing Personnel Qualification
and Certification 4
1.2 This practice shall be applicab le to the development of
an examination procedure agreed upon between the users of 2.5 API Standard:
this practice. API STD–1104 Welding of Pipeline and Related Facilit ies 5
1.3 The values stated in SI units are to be regarded as the 2.6 CSA Standard:
CSA Z-662 Oil and Gas Pipelines Systems 6
standard. The inch-pound units given in parentheses are for
informat ion only. 2.7 ISO Standards7
ISO 9712 Nondestructive Testing—Qualification and Certi-
1.4 This standard does not purport to address all of the
fication of NDT Personnel
safety concerns, if any, associated with its use. It is the
responsibility of the user of this standard to establish appro- 3. Terminology
priate safety and health practices and determine the applica-
bility of regulatory limitations prior to use. 3.1 Definitions:
3.1 .1 Definitions relat ing to ultrasonic examination, that
2. Referenced Documents appear in Terminology E1316 shall apply to the terms used in
this practice.
2.1 The following documents form a part of this practice to
the extent specified herein: 3.2 Definitions of Terms Specific to This Standard:
3.2 .1 acceptance criteria—defin it ion of acceptab le/
2.2 ASTM Standards:2 rejectable flaws as defined by an Engineering Critical Assess-
E164 Pract ice for Contact Ultrasonic Testing of Weld ments ment (ECA ), such as defined in CSA-Z662 or API 1104, or
E317 Pract ice for Evaluating Performance Characteristics of workmanship criteria as defined by the contracting agency.
Ultrasonic Pulse-Echo Testing Instruments and Systems
3.2 .2 contract document—any document specified in the
without the Use of Electronic Measurement Instruments
contract between the contracting agency and contractor, includ-
E543 Specificat ion for Agencies Performing Nondestructive ing the purchase order, specification, drawings or other written
Testing
material.
E1316 Terminology for Nondestructive Examinations

3 Available from American Society for Nondestructive Testing (ASNT), P.O. Box

1 This practice is under the jurisdiction of ASTM Committee E07 on Nonde- 28518, 1711 Arlingate Ln., Columbus, OH 43228-0518, http://www.asnt.org.
4 Available from Aerospace Industries Association of America, Inc. (AIA), 1000
structive Testing and is the direct responsibility of Subcommittee E07.06 on
Ultrasonic Method. Wilson Blvd., Suite 1700, Arlington, VA 22209-3928, http://www.aia-aerospace.org.
5 Available from American Petroleum Institute (API), 1220 L. St.,
Current edition approved June 1, 2016. Published June 2016. Originally NW,
approved in 1998. Last previous edition approved in 2011 as E1961 - 11. DOI: Washington, DC 20005-4070, http://www.api.org.
6 Available from Canadian Standards Association (CSA), 5060 Spectrum Way,
10.1520/E1961-16.
2 For referenced ASTM standards, visit the ASTM website, www.astm.org, or Mississauga, ON L4W 5N6, Canada, http://www.csa.ca.
7 Available from International Organization for Standardi zation (ISO), ISO
contact ASTM Customer Service at service@astm.org. For Annual Book of ASTM
Standards volume information, refer to the standard’s Document Summary page on Central Secret ariat, BIBC II, Chemin de Blandonnet 8, CP 401, 1214 Vernier,
the ASTM website. Geneva, Switzerland, http://www.iso.org.

*A Summary of Changes section appears at the end of this standard

1
本资料由领翼NDT网校/领翼NDT商城整理,仅供个人学习交流使用,请勿用于商业目的!
E1961 − 16
3.2 .3 contracting agency—a government agency, prime diameters if the techniques can be proven to provide the
contractor or subcontractor procuring ultrasonic examination required zonal discrimination.
services. 4.4 Examination zones are typically 2 to 3 mm (0.08 to 0.12
3.2 .4 contractor—the nondestructive examination contrac- in.) in height. For most applications this will require the use of
tor engaged by the contracting agency in work covered by this contact focused search units to avoid interfering signals origi-
practice. nating fro m off-axis geo metric reflectors and to avoid exces-
3.2 .5 mapping type presentations—an ultrasonic image pre- sive overlap with ad jacent zones.
sentation whereby the digitized A-scan signal is represented as
colors or grayscale for amplitude variation along one axis 5. Basis of Application
representing time of flight and the other axis is the samp ling 5.1 The following items are subject to contractual agree-
position, or the distance along the weld. ment between the parties using or referencing this standard.
3.2 .6 operator(s)—the term “operator(s)” as used in this
5.2 Personnel Qualification:
practice shall mean the operator(s) of ultrasonic equipment
5.2 .1 If specified in the contractual agreement, personnel
who is (are) certified according to the requirements in 5.2 and
performing examinations to this standard shall be qualified in
at a level deemed acceptable to the contracting agency.
accordance with a nationally or internationally recognized
4. Significance and Use NDT personnel qualification pract ice or standard such as
ANSI/ASNT-CP-189, SNT-TC-1A, NAS-410, ISO 9712, or a
4.1 This practice is intended primarily for the mechanized
similar document and certified by the employer or certify ing
ultrasonic examination of pipe girth welds used in the con-
agency, as applicable. The pract ice or standard used and its
struction of gas and oil p ipelines. This practice, with appropri- applicable revision shall be identified in the contractual agree-
ate modifications due to changes in weld profile, may also be
ment between the using parties.
used to examine repaired welds. Manual techniques such as
described in Practice E164 may also be used to examine 5.3 Qualification of Nondestructive Agencies—If specified
production or repaired welds. This practice, with appropriate in the contractual agreement, NDT agencies shall be qualified
modifications, may also be used to examine other forms of butt and evaluated as described in Practice E543. The applicable
welds includ ing long seams. edition of Practice E543 shall be specified in the contractual
agreement.
4.2 Techniques used are to be based on zonal discrimination
whereby the weld is divided into approximately equal vertical 5.4 Procedures and Techniques—The procedures and tech-
examination sections (zones) each being assessed by a pair of niques to be used shall be as specified in the contractual
ultrasonic search units. See Fig. 1 fo r typical zones. agreement.
4.3 Thicknesses of material examined are normally 7 to 25 5.5 Surface Preparation—The pre-examination surface
mm (0.28 to 1.00 in.) and pipe d iameters 15 cm (6.0 in.) and preparation criteria shall be in accordance with 10.2, unless
greater but this standard may apply to other thicknesses and otherwise specified.

FIG. 1 Schem atic Representation of Weld Zones and Discontinuities

2
本资料由领翼NDT网校/领翼NDT商城整理,仅供个人学习交流使用,请勿用于商业目的!
E1961 − 16
5.6 Timing of Examination—The timing of examination 7.2 Recording System:
shall be in accordance with 10.3, unless otherwise specified. 7.2 .1 A distance measuring circuit or device suitable for
5.7 Extent of Examination—The extent of examination shall connection to the recorder or acquisition system shall provide
be in accordance with Sect ion 8, unless otherwise specified. a means of electronically determin ing circu mferential weld
distance to an accuracy of typically 61 cm (0.4 in.) or better,
5.8 Reporting Criteria/Acceptance Criteria—Reporting cri- as required by the contracting agency, over the circumference
teria fo r the examination results shall be in accordance with of the weld (an optical encoder is typically used for such
Section 11, unless otherwise specified. Since acceptance crite- distance measurement). Programmed scan lengths shall be
ria are not specified in this standard, they shall be specified in sufficient to ensure all p robes will travel the maximu m circu m-
the contractual agreement. ferential d istance required for a pipe having a diameter with the
5.9 Reexa mination o f Repai red/Reworked Items— maximu m to lerance allowed by the contracting agency’s speci-
Reexamination of repaired/reworked items is not addressed in fication. For equip ment with encoders traveling on a t rack or
this standard and if required shall be specified in the contrac- weld ing guide-band a correct ion factor will be incorporated to
tual agreement. ensure the circumferential d istance recorded on the chart
corresponds to the search unit position on the pipe outer
6. Examination Methods
surface. The recording or marking system shall clearly indicate
6.1 Visual Examination—All welds shall be visually exam- the location of discontinuities relative to the marked starting
ined after co mp letion and assessed in accordance with the position of the scan, with a 61 cm (0.4 in.) accuracy. There
requirements of surface conditions for ultrasonic examination. shall be record ings from each search unit for weld discontinui-
6.2 All bevels shall be examined immed iately after mach in- ties and confirmation of the acoustic coupling arranged on the
ing to ensure compliance with the applicable welding proce- chart or display in a manner acceptable to the contracting
dure. This examination should be combined with scribing the agency.
reference line as described in 10.4. 7.2 .2 B-scan or other form o f “mapping” displays will be
used for volumetric flaw detection and characterizations and
6.3 Any items of non-compliance shall be referred to the
Time of Flight Diffraction (TOFD) techniques may be added to
contracting agency representative for corrective action. improve characterization and sizing. TOFD techniques may
6.4 Ultrasonic Examination—All girth welds identified for augment pulse-echo techniques but shall not replace pulse-
mechanized ult rasonic examinat ion shall be examined for echo techniques.
100 % of their circu mference and assessed in accordance with 7.2 .3 Where TOFD techniques are employed the recording
the contracting agency’s acceptance criteria. Examination system shall be capable of a 256-level grayscale display and be
should be conducted in accordance with procedures approved capable of recording full R-F wave forms for the TOFD search
by the contracting agency. unit pairs.
7. Ul trasonic Equi pment 7.3 Coupling—The coupling shall be obtained by using a
med iu m suitable for the purpose. An environmentally safe
7.1 Ultrasonic System—The system shall provide an ad-
wetting agent may be required to enhance acoustic coupling.
equate number of examination channels to ensure the complete
No residue should remain on the pipe surface after the liquid
volumetric examination of the weld through thickness in one
has evaporated. For examination where amb ient temperatures
circu mferential scan. The instrument shall provide a linear “A”
are belo w 0°C (32°F) a methyl alcohol washer flu id or a similar
scan presentation for each channel selected. The examination
med iu m may be used. This liquid mediu m may be recovered
channels will allo w the volu me of the weld scanned to be
and filtered for re -use. For examination where p ipe cool-down
assessed in accordance with the examination zones as typically
may be required after weld ing, water spray or other agents may
defined in Fig. 1. Instrument linearity shall be determined
be used with contracting agency approval.
according to the procedures detailed in Practice E317, within
six months of the intended end use date. The contractor shall 7.4 Search Units:
retain a copy of the calibration certificate. Instrument linearity 7.4 .1 Each search unit shall be marked with a method to
shall be such that the accuracy of any indicated amplitude is identify the manufacturer’s name, search unit type, exit point,
within 5 % of the actual full scale amplitude. This shall apply incident beam angle o r refracted beam angle for a specific
to both linear and logarith mic amp lifiers. Each examination wedge/steel velocity ratio, frequency, and crystal size.8
channel shall be selective for: pulse-echo or th rough- 7.4 .2 The search unit array design shall be specific to the
transmission mode, gate position and length for a min imu m of project where the examinat ion is to be performed.
two gates, and gain. Recording thresholds shall be selectable to 7.4 .3 All search units shall be contoured to match the
display signals between 0 and 100 % of fu ll screen height for curvature of the pipe surface.
simp le amplitude and transit time record ing and shall be from 7.5 Reference Standards—Reference standards shall be used
0 to 100 % for B-scan or “mapping” type recording of data. to establish sensitivity and qualify the examination system for
Two recordable signal outputs per gate shall be available, being field examination and to monitor the system’s performance on
either analog or dig ital and rep resentative of signal height and
time of flight. These will be suitable for recording on a
mu lti-channel recorder or co mputer data acquisition software 8 For phased array and EMAT probes, not all of the listed items may be

display. applicable.

3
本资料由领翼NDT网校/领翼NDT商城整理,仅供个人学习交流使用,请勿用于商业目的!
E1961 − 16
an ongoing basis. Reference standards shall be manufactured adjusted to 80 % full-screen height (FSH) for each channel.
fro m a section of unflawed project-specific line p ipe supplied The gain level determined for each search unit shall be the
by the contracting agency. The contracting agency will provide primary reference.
the contractor with details of project-specific weld geo metries 8.2 Gate Settings:
and the reference reflectors required in specific areas. The 8.2 .1 Fusion-Zone Search Units—Using the reference
contractor shall then provide a reference standard design that standard, each detection gate shall be set to cover a sound path
must be submitted to the contracting agency for approval distance that starts at least 3 mm (0.12 in.) before the weld
before manufacturing. No design changes to the reference preparation and ends at least 1 mm (0.04 in.) past the weld
standard shall be made without prior approval of the contract- centerline. The gate start position with respect to the weld
ing agency. Annex A 3 provides an examp le of a typical preparation and gate length for each channel shall be recorded
reference standard. in the procedure.
7.6 Ultrasonic Examination Procedure—The contractor 8.2 .2 Porosity Detection Search Units (Fill Region)—
shall provide a procedure that will provide examination criteria Porosity provides a weak and characteristically different re-
for the ultrasonic examinat ion of the weld in a single pass. It flected signal compared to specular reflection fro m nonfusion
must allo w for characteristic Hi/ Lo fit-ups (edge discontinuities. Dedicated channels using B-scan or mapping
misalignment), weld shrinkage and be pipe-size specific. Pro- type presentations are recommended for detecting and charac-
cedures submitted will allow zonal flaw characterization that terizing porosity and other volumetric flaws. One of the
permits use of the contracting agency’s engineering critical fusion-zone search units can be used for porosity detection or
assessment acceptance criteria. It shall include but not be (an) extra search unit(s) may be added to the array. Using the
limited to describing the following requirements: reference standard, each mapping gate should be set to cover a
7.6 .1 The mechanized variable speed scanner mountable on sound path distance which starts at least 1 mm (0.04 in.) before
mechanical weld ing bands or other tracking mechanis m, the weld preparation and long enough to encompass the weld
7.6 .2 The encoder capable of accurately indicat ing any flaw bevel on the opposite side of the weld centerline. For test piece
location about the girth weld, thickness greater than about 12 mm (0.5 in.), beam character-
7.6 .3 Independently loaded ultrasonic search units mounted istics may require the use of more than one search unit for
in an array that provides independent examination of the weld porosity detection in the fill regions. Scanning sensitivity
fro m both sides, should be typically 8 to 14 d B over that required to achieve an
7.6 .4 Provisions for adjusting and maintain ing the align- 80 % FSH signal fro m a flat-bottom hole (FBH) typically 1.5
to 2.0 mm (0.060 to 0.080 in.) diameter, but should not be so
ment of these search units,
great as to cause interfering electrical or geo metric noise that
7.6 .5 Prov isions for record ing the cont inuity of the
could be misinterpreted.
coupling,
8.2 .3 Porosity Detection Search Units (Root Region)—
7.6 .6 Provisions for ensuring the mechanical reliability of Using the reference standard each detection gate shall be set to
the equipment,
cover a sound path distance which starts at least 1 mm (0.04
7.6 .7 A technique summary stating beam angles, wave in.) before the weld preparat ion and long enough to ensure
types, search unit frequencies, beam sizes and profiles with coverage of the weld root area. Fusion-zone search units in the
sketches for each geometry to be examined, lowest examination zone(s) can be used for porosity detection
7.6 .8 Record analog or dig ital signals fro m the mu lti- in the root region or (an) extra search unit(s) may be added to
channels to a common distance of rotation, the array. Scanning sensitivity requirements for porosity detec-
7.6 .9 Provide permanent copy of the scans in an easily tion in the root region shall be adequate to ensure detection of
interpretable format to meet archival and audit needs, porosity in this region. Scanning sensitivity should be typically
7.6 .1 0 Provide construction and accuracy details of the 4 to 14d B over that required to ach ieve an 80 % FSH signal
reference standard, fro m a FBH typically 1.5 to 2.0 mm (0.060 to 0.080 in.)
7.6 .1 1 Provide the standardization procedures to be used in diameter but should not be so great as to cause interfering
the field, and electrical or geometric noise that could be misinterpreted.
7.6 .1 2 Standardization checks shall be established and veri- 8.3 Evaluation Threshold—The evaluation threshold for
fied on a time or weld cycle defined by the contracting agency. each detection channel shall be typically 20 % of full screen
System perfo rmance between standardization checks shall be height or greater for fusion zones. All signals above this
continually monitored for degradation. amp litude will be evaluated in accordance with the contracting
agency’s acceptance criteria. Porosity detection channels may
8. Ul trasonic Examinati on Set-Up use a threshold for evaluation or patterns in mapping type
8.1 Search Unit Positioning and Pri ma ry Reference channels and transit time may be used to characterize porosity.
Sensitivity—The system shall be optimized for field examina- 8.4 Recording Set-Up—Channel output signals shall be
tion using the reference standard. Each search unit shall be arranged on the recording display in a manner that allows the
positioned at its operating distance from the simulated weld weld to be presented symmetrically on either side of the weld
centerline on the reference standard and adjusted to provide a centerline. In addition, delays shall be applied to the signals
peak signal fro m its target reference reflector in the search fro m each search unit to co mpensate for the various circu m-
unit’s examination zone. The peak signal response shall be ferential positions relat ive to the circu mferential zero point.

4
本资料由领翼NDT网校/领翼NDT商城整理,仅供个人学习交流使用,请勿用于商业目的!
E1961 − 16
Details of the delays applied and the chart arrangement shall be 10.4 Referen ce Line— Prior to weld ing the Contractor
recorded in the procedure. should scribe a referen ce line on th e p ipe surface at a d istance
8.5 Circumferential Scanning Velocity—For asynchronous of 40 mm (1.60 in .) 6 0.5 mm (0.020 in.) fro m th e centerline
system, the circu mferential scanning velocity Vc shall be of the weld p reparat ion, on the examinat ion band s ide. The
determined by: reference line shall be used to ensure that the search un it array
is ad justed to th e same d istance fro m th e centerline as to
PRF
V c # Wc 3
duplicate the reference standard . The to lerance to id eal posi-
(1) tioning should not exceed 60.5 mm (0.020 in.).
3
where: Wc is the narro west -6dB beam width at the appro- 10. 5 System Performance:
priate operating distance(s) of the all search units and PRF is 10. 5. 1 Sensitivity Verification—The reference standard shall
the effective pulse repetition frequency per search unit. be used to verify scanning sensitivity at the start of each shift
For synchronous systems, the sample interval shall be 1 mm and thereafter at intervals not exceed ing 2 h or ten welds,
(0.04 in.) regardless of travel speed. whichever co mes first, and at the conclusion of each shift or at
intervals defined by the contracting agency. Hardcopy records
--` `,, ,, ,`` `, `,, ,` ``, ,, ``, ,, ,`` -` -`, ,` ,,` ,` ,,` -- -

9. Dynamic Standardization
for each reference standard scan should be included sequen-
9.1 Detection Channels:
tially with the weld examination data. During production weld
9.2 With the system optimized the reference standard shall examination, at the contracting agency’s discretion, the system
be scanned at the same speed at which the examination will be may be operated at a higher gain to ensure detection of flaws
performed. The analog or digital record ing shall indicate and to compensate for differences in coupling efficiencies
signals, 80 % FSH, fro m each reference reflector recorded in between the reference standard and the production pipe.
their correct position assigned on the display. The circu mfer- Whereas for initial standardization, the channels should ind i-
ential positional accuracy of the recorded reflectors relative to cate 80 % FSH, a satisfactory standardization during produc-
each other should be within typically 62 mm (0.080 in.), and tion may ind icate values from 70 to 99 % FSH. Standardizat ion
with respect to the zero start they should be within typically 61 outside of this range should require restandardization of the
cm (0.4 in.). system (see 10.7.1).
9.3 Acceptability of a system to produce a standardization 10. 5. 2 Circumferential Position Accuracy Verification—The
chart or record will be based on its ability to discriminate positional accuracy of the chart distance markers shall be
examination zones typical of those described in Fig. 1. This verified prior to commencement of the project and verified
will be demonstrated by signals from ad jacent zones being at monthly. The scanner shall travel fro m the zero position with
least 6 dB and not more than 14 dB lower than fro m the zone the scanning frame and the pipe zero position coincident. At
for wh ich a search unit channel is standardized for. Failure to the 1⁄4, 1⁄2 and 3⁄4 positions, the index marks on the scanning
ensure the 6 to 14 d B separation between zones may be frame and pipe shall be aligned. The chart shall then be
unacceptable and could require repositioning of the search unit compared to circu mferential distance measured with a tape
or a complete search unit replacement. Actual dB separation measure placed on the outer surface of the pipe; chart accuracy
requirements may be stipulated by the contracting agency. should typically be 61 cm (0.4 in.), or better, over the
circu mference.
9.4 Coupling Monitor Channels—A method shall be em-
10. 5. 3 Temperature Differentials and Control—Where tem-
ployed to determine that constant coupling is achieved during
perature differences between reference standard’s surface,
examinations. An examination of the test piece with its surface
search unit wedge material and examination surface cause
wiped dry (lack of couplant) shall produce a record showing an
absence of the couplant recording signal. shifts in refracted angle wh ich result in the system not being
able to provide the required zonal d iscrimination, a means of
10. Fiel d Exami nation regulating the temperature of the reference standard or search
10. 1 Weld Identification—Each weld shall be identified by a unit wedge material, or both, shall be employed.
unique number, a “0” mark and arrow, designating start point 10. 5. 4 Weld Zone Identification—The system shall be ca-
and direction of travel. The mark shall not interfere with pable of identifying all d iscontinuities identified in Fig. 1 or
scanning. those defined in API 1104 and clearly identifying the specific
zone in which they are located.
10. 2 Surface Condition—A10 cm (4.0 in.) wide scanning
area on each side of the weld shall be clear of weld spatter and 10. 6 Scanning Sensitivity—Scanning shall be at least at
other conditions which may interfere with the movement of the primary reference sensitivity for fusion-zone channels and at
search units, the coupling liquid, or the transmission of the added gain setting for porosity detection channels as
acoustic energy into the material. Any surface condition such described in 8.2.2 and 8.2.3.
as geometry, coating, etc., imped ing the ultrasonic examination 10. 7 Re-Examination:
shall be noted for corrective action prior to scanning. 10 .7 .1 Sensitivity—If standardization during production
10. 3 Time of Inspection—Unless otherwise detailed in the weld examination indicates one or more channels with values
contract, examination may begin anytime after welding and outside the range defined by the contracting agency, the data
when the surface temperature is low enough to allow the fro m the welds scanned since the last acceptable standardiza-
application of couplant. tion shall be evaluated to determine if the examination was

5
本资料由领翼NDT网校/领翼NDT商城整理,仅供个人学习交流使用,请勿用于商业目的!
E1961 − 16
acceptable or if the weld must be re-examined. The contracting should contain sufficient resolution and contrast so that the
agency shall provide a written procedure for the evaluation of rationale for flaw evaluations can be easily seen by the
suspect welds and define requirements for re-examination. contracting agency’s representative.
10 .7 .2 Coupling Monitoring—An area with lack o f coupling 11. 2 Time of Report—For examination during production
as indicated by the absence of a coupling monitor signal over weld ing ultrasonic examination of the weld should be carried
a circu mferential d istance exceeding the minimu m allowab le out as soon as possible after the weld has been completed. The
flaw length, should be re-examined. entire examination of a weld, including ultrasonic examination,
10 .7 .3 Scanning speed will be limited by mechanical ability evaluation and production of the weld examination record
to maintain acoustic coupling and by the system’s electronic should not take longer than the weld production cycle. Evalu-
ability to ensure full waveforms are captured without missing ation of a weld and the associated weld examination data
data points. Missing data exceeding 5 % of the scan lines to be should be completed prior to co mmencement of the subsequent
collected, or two or more ad jacent data lines being missed shall weld.
require re-examinat ion.
11. Report 12. Standards of Acceptability
11. 1 Weld Examination Chart—The examination data pro- 12. 1 Standards of acceptability are to be established by the
duced as a permanent record shall consist of a complete strip - contracting agency. These may be based on workmanship or
chart type hardcopy showing the reference point, the d irection Engineering Crit ical Assessment (ECA) calculations. Ex-
of scanning, date and time of examination, and the name o f amp les of ECA determined acceptance criteria are shown in
the operator. The examination zone identified in each channel Tables 1 and 2 (see Note 1).
shall also be recorded. Alternate arch ival record formats may NOTE 1—Values in T able 1 and Table 2 are provided in only metric
be approved by the contracting agency. For B-scan data, (T able 1) or inch pound (T able 2), as they are actual industry examples.
depending on noise level, colors for mapping can be selected Each is derived from different calculations and only the units of calcula-
down to 3 to 5 % FSH to aid in characterizing flaws. tion are used in the table.
Colors used shall provide a rap id means of identifying areas of
concern. Colors on monitor displays and colors or gray scales 13. Keywords
used on printouts should be selected to provide useful 13. 1 contact focused search units; girth welds; mechanized
informat ion to the operator. However, in addition the hardcopy ultrasonics

6
本资料由领翼NDT网校/领翼NDT商城整理,仅供个人学习交流使用,请勿用于商业目的!
E1961 − 16
TABLE 1 Mechanized Girth Weld Acceptance CriteriaA,B,C
Table 1 Note A: Based on Appendix K of CSA-Z662.
Table 1 Note B: This table is an example only. It is used here to illustrate how zonal d iscrimination can be applie d to acceptance criteria. Acceptable lengths are based
on calculations deriv ed from destructiv e testing for a specific material.

A External undercut, low cap, cap porosity and excessiv e external weld reinf orcement may be assessed by v isual examination.
B Flaw interaction should be considered in def ining the eff ectiv e flaw length. See API 1104 Appendix A f or examples of flaw interaction.
C
All weldin g procedures assessed in accordance with this criteria should be qualif ied according to the appropriate gov erning standard, f or example CSA Z662, Appendix
K or API 1104.

7
本资料由领翼NDT网校/领翼NDT商城整理,仅供个人学习交流使用,请勿用于商业目的!
E1961 − 16
TABLE 2 Example Acceptance Criteria based on API 1104—Appendix A
Table 2 Note A: Parameters:
Pipe diameter– 30.0 in.
Wall thickness– 0.577 in.
Crack tip opening displacement attained– 0.01 in.
Maximum applied strain– 0.002 (100 % y ield) (inches per inch)
Examination error– 0.05 in. (depth measurements)

ANNEXES

(Mandatory Information)

A1. DETERMINING ACOUS TIC VELOCITY IN PIPE S TEELS

A1.1 General : essential to know the velocity of the two media. This is
especially critical where focused beams are used for zonal
A1.1.1 The procedure defined in this annex covers the
discrimination.
methods that may be used to determine acoustic velocity of
shear waves in line p ipe steels. A1.2 Equipment :
A1.1.2 Line pipe used in oil and natural gas transmission A1.2.1 To carry out the examinations the following equip-
pipelines is generally made of various grades of steel. The ment is recommended:
rolling processes used by various manufacturers orientates the A1.2.1.1 M icro meter or vernier caliper,
acicular grains with their long axis parallel to the direction of A1.2.1.2 Contact SH (horizontally polarized) shear wave
rolling. Size of grains as well as exact details of chemistry and search unit (5 MHz, 6 mm to 10 mm diameter),
stresses resulting fro m the rolling to shape (long-seam o r A1.2.1.3 Coupling fluid for SH shear waves (honey or other
spiral-seam pipe) allows for variations in acoustic velocities non-Newtonian viscous fluids), and
fro m manufacturer to manufacturer. In addit ion, the variation A1.2.1.4 Ultrasonic pulser-receiver with receiver with a
in grain characteristics and stress with respect to direction of -6d B bandwidth typically fro m 1 M Hz to 10 MHz and a CRT
propagation causes acoustic velocity variat ions with resultant type display capable of displaying received RF signals and
changes in the refracted angle of the sound in the steel. capable of at least 10 nanosecond resolution.
A1.1.3 Examination of welds in line p ipe steel by ultrasonic
A1.3 Specimen Preparation:
methods invariably uses refracted sound beams. Since the
acoustic velocity ratio between the incident material and A1.3.1 Steel used in line pipe is anisotropic, therefore
refract ing material determines the angle of refraction it is measurements made must specify the direction of sound beam

8
本资料由领翼NDT网校/领翼NDT商城整理,仅供个人学习交流使用,请勿用于商业目的!
E1961 − 16
propagation. A min imu m of three read ings shall be made for birefringence. This birefringence results from the anisotropic
each plane in wh ich examination will be done. nature of the material. The velocity varies according to the
A1.3.1.1 A specimen is cut fro m a section of pipe to be relative direction of the shear-wave polarizat ion and the
examined and the corresponding results are specific for a microstructure of the material. Adjust the oscilloscope and read
particular pipe diameter, wall thickness and manufacturer. the interval of time between the faster of the two back
Specimen dimensions should be a minimu m o f 50 by 50 mm (2 reflection signals and the faster of the two first frontwall
by 2 in.); however, larger sections may be preferred fo r mu ltip le signals. An examp le of the birefringent signal is
handling and machining. shown in Fig. A 1.2.
A1.3.2 A min imu m of two parallel surfaces are mach ined A1.4.3 Record the time interval measured.
for the plane to be evaluated; one pair of surfaces is made in the
radial d irection (perpendicular to the outer surface) and the A1.4.4 In addition to the two measurements made fro m the
other pair made 20° fro m the perpendicular to the outer mach ined surfaces (axial and angled velocit ies), make a third
surface. Additional pairs of parallel surfaces may be mach ined reading fro m the outer surface for rad ial velocity. This will
at other angles in the p lane to be evaluated if more data points require a th ickness reading of the pipe wall at the point of
are desired. search unit contact using the micro meter or vernier caliper. The
configuration shown for the test sample in Fig. A 1.1 is for
A1.3.3 The machined surfaces should be smooth to a 20-µm radial velocity determination. The slots shown in the specimen
fin ish or better. Min imu m width of the specimen surface to be in Fig. A 1.3 are for measurements that would be made for girth
measured should be 20 mm and the min imu m thickness weld examinations. If long seam welds were to be examined it
between the parallel surfaces to be measured should be 10 mm. would be necessary to make measurements in the circu mfer-
Vertical extent of the test surface will be limited by the pipe ential plane, in that case the axial velocity would be rep laced
wall thickness. by the circumferential velocity and the angled velocity would
A1.4 Procedure : be taken at 20°fro m the perpendicular but in the circu mferen-
tial p lane.
A1.4.1 Using the micro meter or vern ier caliper measure the
thickness of the steel specimen between the machined parallel A1.4.5 Determine the acoustic velocities of the three direc-
faces. tions assessed using the equation:
A1.4.2 Assemble the ultrasonic pulser/receiver, SH shear 2d
( A1 .1 )
wave search unit and oscilloscope as illustrated in Fig. A 1.1 V5
t
using honey or other acceptable couplant (see A1.2.1) to where:
acoustically couple the search unit to the specimen. Exert V = velocity,
sufficient pressure on the search unit to obtain a clearly defined d = sample thickness (physically measured), and
back reflection and one multip le. Pivot the search unit on the t = t ime interval (measured by pulse-echo).
test surface and observe there may be t wo closely spaced
signals at the back reflect ion and mult iple; this is due to A1.5 Tolerances —In ord er that th e error in velocity det er-
minat ion be not g reater than 6 20 m/s (780 in ./s), th ickness
measurements of the samp les must be accu rate to 60.1 mm
(0.004 in.) and t ime measurements must b e accurate to 6 25
ns.
A1.6 Recording and Plotting—Values for the velocities
determined can be tabulated and graphed. By plotting veloci-
ties on a two-dimensional polar graph for a single plane,
velocities at angles other than those made directly can be
estimated. The effect of temperature on velocity can be
significant under extreme examination conditions, therefore the
temperature at which these readings have been made should
FIG. A1.1 Exam ple of Equipment Setup also be recorded.

9
本资料由领翼NDT网校/领翼NDT商城整理,仅供个人学习交流使用,请勿用于商业目的!
E1961 − 16

FIG. A1.2 Exam ple of Time Interval Measured in Birefringent Ma-


terial

FIG. A1.3 Steel Specimen

A2. TYPIC AL S EARCH UN IT CONFIGURATION

A2.1 Fig. A 2.1 illustrates a typical configuration for search (GMAW) process. The six zones identified would be typical of
unit array placement on a girth weld. Motion is facilitated a pipe wall th ickness of 12.6 mm (0.496 in.). Search unit
using mechanized carrier on a welding band which keeps the placement is symmetric about the weld centerline. On ly search
search unit exit points at fixed distances from the weld units used on one side of the weld are illustrated.
centerline.
A2.2 Fig. A 2.2 illustrates an examp le of beam configura-
tions used to examine a weld in a single pass. The weld bevel
illustrated is used in an Automatic Gas Metal Arc Welding

10
本资料由领翼NDT网校/领翼NDT商城整理,仅供个人学习交流使用,请勿用于商业目的!
E1961 − 16

FIG. A2.1 Typical Search Unit Configuration

FIG. A2.2 Exam ple of Beam Configurations

11
本资料由领翼NDT网校/领翼NDT商城整理,仅供个人学习交流使用,请勿用于商业目的!
E1961 − 16

A3. MINIMUM REQUIREMENTS FOR REFERENCE S TANDARDS

A3.1 Instrument Standardization—A reference standard A3.5 Targets :


shall be constructed and used to standardize the system and
A3.5.1 Targets shall be arranged to allow zonal discrimina-
demonstrate proper positioning and performance o f the scan-
tion based on both weld profile and nu mber of fill passes. (See
ning apparatus.
Fig. A3.1).
A3.2 Material :
A3.5.2 Primary reference targets for fusion areas should be
A3.2.1 Material used shall be taken fro m p ipe of the same typically 2 to 3 mm (0.08 to 0.12 in.) d iameter flat-bottom
manufacturer, d iameter, thickness, and seam type as that to be holes (FBH).
examined.
A3.5.3 Square slots 1 mm (0.04 in.) deep and 2 mm (0.080
A3.2.2 Acoustic velocity shall be determined using SH
in.) wide should be machined typically 1 to 2 cm (0.4 to 0.8 in.)
shear waves for specific angles cut from the same pipe material
long on the design fusion line to indicate locations where
to be used (see Annex A 1).
undercut or surface breaking non-fusion would occur on the
A3.3 Dimensions —Overall dimensions of the reference pipe outer surface. Slots may also be used for the root fusion
standard and its actual shape shall be determined by the size o f zone. Root slots should be typically 1 to 2 cm (0.4 to 0.8 in.)
the search unit array and block support structure. The standard long and their depth and angular configuration should be
(and its mounting) shall provide sufficient surface area to identical to the root bevel used in the weld process being
permit the entire search unit array to traverse the target area of examined.
the reference standard during dynamic standardization scan-
A3.5.4 A centerline through hole, 2 mm (0.08 in.) diameter,
ning. The standard and mounting should be equipped with a
permanently mounted welding band to allow the array to be should be drilled to verify detectability o f centerline flaws and
correctly positioned and moved during dynamic standardiza - to ensure gate length is sufficient to cover 1 mm (0.04 in.) past
tion scanning. the weld centerline.

A3.4 Identification —All standards shall be permanently A3.6 Lateral positioning of the targets shall be such as to
identified using hard stamps. Information recorded for each allo w for independent signals. The beam of each search unit
reference standard shall include; manufacturer, diameter, wall shall pass across the target without any part of the beam
thickness, acoustic velocity and serial nu mber. The serial encountering adjacent targets during the time the primary
number shall be used to trace recorded informat ion with target is in the beam. (See Fig. A 3.2).
regards to acoustic velocities, manufacturer and target infor-
mat ion.

12
本资料由领翼NDT网校/领翼NDT商城整理,仅供个人学习交流使用,请勿用于商业目的!
E1961 − 16

NOTE 1—Fig. A3.1 use s a weld bevel configuration typical of the automatic gas metal arc welding process to illustrate the minimum number of targets
for a more complex weld bevel geometry.
FIG. A3.1 Illustrations of Targets

NOTE 1—Fig. A3.2 illustrates placement of holes and slots relative to the weld centerline for a six -zoned weld similar to the configuration used in Fig.
A3.1.
FIG. A3.2 Illustrations of Target Layout on Reference Standard Pipe Section

13
本资料由领翼NDT网校/领翼NDT商城整理,仅供个人学习交流使用,请勿用于商业目的!
E1961 − 16
A3.7 The contractor may add other targets to the above Hole diameters ±0.2 mm (0.008 in.)
minimu m required in A 3.5 provided they do not interfere with Slot lengths ±1.0 mm (0.040 in.)
Slot depths ±0.2 mm (0.008 in.)
the required targets. All pertinent angles ±1°
Center position of all targets ±0.2 mm (0.008 in.)
A3.8 Tolerances —Tolerances of targets should be as fo l-
lows:

SUMMARY OF CHANGES

Co mmittee E07 has identified the location of selected changes to this standard since the last issue (E1961 - 11)
that may impact the use of this standard. (June 1, 2016)

(1) Added ISO 9712 to 2.7 and subsection 5.2.1. (4) Renu mbered notes in Table 1 fro m “Note 1” and Note 2” to
(2) Corrected subsection 8.2.2, to use “specular” in place of “Table 1 Note A” and “Table 1 Note B.”
“perpendicular.” (5) Renu mbered note in Table 2 fro m “Note 1” to “Table 2
(3) Addressed re-examination criteria for missing data lines in Note A.”
subsection 10.7.3.

ASTM International takes no position respecting the validity of any patent rights asserted in connection with any item me ntioned
in this standard. Users of this standard are expressly advised that determin ation of the validity of any such patent rights, and the risk
of infringe ment of such rights, are entirely their own responsibility.

This standard is subject to revision at any time by the responsible technical committee and must be reviewed every five years and
if not revised, either reapproved or withdrawn. Your co mments are invited either for r evision of this standard or for add itional standards
and should be addressed to ASTM International Head quarters. Your co mments will receive careful consideration at a meeting of the
responsible technical co mmittee, which you may attend. If you feel that your comments have not received a fair hearing you should
make your views known to the ASTM Co mmittee on Standards, at the address shown below.

This standard is copyrighted by ASTM International, 100 Barr Harbor Drive, PO Box C700, West Consho hocken, PA 19428-2959,
United States. Individual reprints (single or multiple copi es) of this standard may be obtain ed by contacting ASTM at the above
address or at 610-832-958 5 (phone ), 610-832-9 555 (fax), or service@astm.org (e- mail); or through the AS TM website
(www.astm.org). Per mission rights to photocopy the standard may also be secured from the Copyright Clearance Ce nter, 222
Rosewood Drive, Danvers, MA 01923, Tel: (978) 646-2600; http://www.copyright.com/

14
本资料由领翼NDT网校/领翼NDT商城整理,仅供个人学习交流使用,请勿用于商业目的!