TWO WAY SLAB DESIGN

BUILDING NAME ADMIN BUILDING -RANASTHALAM


SAMARTH INFRA ENGG
DESIGN BY NRK DATE 05.03.19
TECHNOCRATS (INDIA)
CHECKED BY MPB DATE 06.03.19
PVT. LTD.
APPROVED BY MRRK DATE 07.03.19

DESIGN OF TWO-WAY SLAB

Grade of Steel 500 N/mm2


Grade of concrete 25 N/mm2
LOADS
Self wt.of slab 0.575 t/sq.m
Super Imposed Live Load 0.3 t/sq.m
Total load 0.88 t/sq.m
Design Load 1.31 t/sq.m

EDGE CONDITION one long edge discontinuous


Shorter Span(Lx) 3.6 m
Longer Span (Ly) 3.6 m
Ratio 1
Design Width,b 1000 mm
Depth of slab,D 150 mm
Effective Cover 20 mm
Effective Depth,d 130 mm

Calculation of Moments

The moment co-efficients for calculation of moments are taken from


Table:26 of IS-456:2000.

POSITIVE MOMENT AT MID SPAN

ax 0.028
MX 0.476 T-m

ay 0.028
MY 0.476 T-m

NEGATIVE MOMENT AT CONTINUOUS EDGE

ax 0.037
MX 0.629 T-m

ay 0.037
MY 0.629 T-m

Page 1
TWO WAY SLAB DESIGN
BUILDING NAME ADMIN BUILDING -RANASTHALAM
SAMARTH INFRA ENGG
DESIGN BY NRK DATE 05.03.19
TECHNOCRATS (INDIA)
CHECKED BY MPB DATE 06.03.19
PVT. LTD.
APPROVED BY MRRK DATE 07.03.19

required depth 52.31052766 mm (sqrt((M/0.138*Fck*b))


hence safe

Calculation of Reinforcement

POSITIVE MOMENT AT MID SPAN


shorter span longer span
Kx 0.42273 (Mx/b*d*d) Ky 0.42273373 (My/b*d*d)
Ptx 0.1 Table 3 SP16 Pty 0.1 Table 3 SP16
Ast x 130 sq.mm Ast y 130 sq.mm

Ast min 180 sq.mm


Ast required 180 Ast required 180
dia provided 8 mm dia provided 8 mm
spacing required 279.253 mm spacing required 279.25268 mm
spacing provided 200 mm spacing provided 200 mm
hense safe
NEGATIVE MOMENT AT CONTINUOUS EDGE
shorter span longer span
Kx 0.55861 (Mx/b*d*d) Ky 0.55861243 (My/b*d*d)
Ptx 0.13 Pty 0.13
Ast x 169 sq.mm Ast y 169 sq.mm

Ast min 180 sq.mm


Ast required 180 Ast required 180
dia provided 8 mm dia provided 8 mm
spacing required 279.253 mm spacing required 279.25268 mm
spacing provided 200 mm spacing provided 200 mm
hense safe

at end support
Ast calculated 125.664 sq.mm 0.5 of Ast provided at middle span
Ast required 200 sq.mm From section 9.3.2 of SP:34 (PAGE-121)
bar dia used 8 mm
spacing required 251.2 mm
spacing provided 200 mm

DEFLECTION CHECK

Ast provided 251.3274123 sq.mm


fs 207.6972007 (0.58*Fy*Ast required/Ast provided)
% of tension reinforcement 0.193328779
modification factor ,Fs 2 from fig 4, pg:38 of is 456,2000
Lx/d Permissible 26
Fs x Lx/d Permissible 52
(Lx/d) 27.69230769

Lx/d<(Fs x Lx/d Permissible) hence safe