College of Engineering
Bachelor of Science in Electrical Engineering
EE311 MACHINES-1
Plate No. 2
Submitted by:
Submitted to:
Engr. Bryan O.
Calma
1. A 4-pole, d.c. generator has a wave-wound armature 3. A d.c. generator generates an e.m.f. of 540 V. It has
with 800 conductors. The flux per pole is 0.0121 Wb. 3,000 armature conductors, flux per pole of 0.013 Wb,
Determine the speed at which it should be run to speed of 1200 r.p.m. and the armature winding has
generate 240 V on no-load. four parallel paths. Find the number of poles.
2. A 40 kW compound generator works on full-load 4. When driven at 4000 r.p.m. with a flux per pole of
with a terminal voltage of 230 V. The armature, series 0.02 Wb, a d.c. generator has an e.m.f. of 200 V. If the
and shunt field resistances are 0.1, 0.05 and 115 Ω speed is increased to 1100 r.p.m. and at the same time
respectively. Calculate the generated e.m.f. when the the flux per pole is reduced to 0.019 Wb per pole, what
generator is connected short-shunt. is then the induced e.m.f. ?
5. Calculate the flux per pole required on full-load for a 7. A 4-pole machine running at 2000 r.p.m. has an
50 kW, 500 V, 8-pole, 700 r.p.m. d.c. shunt generator armature with 90 slots and 6 conductors per slot. The
with 256 conductors arranged in a lap-connected flux per pole is 10 mWb. Determine the terminal e.m.f.
winding. The armature winding resistances is 0.1 Ω, as d.c. Generator if the coils are lap-connected. If the
the shunt field resistance is 200 Ω and there is a brush current per conductor is 100 A, determine the electrical
contact voltage drop of 1 V at each brush on full- load. power.