B 352 214 (Pev-18a-2d)

You might also like

Download as pdf or txt
Download as pdf or txt
You are on page 1of 1

FLOW CONTROL VALVE

(Electro-Proportional, Normally Closed, Fast-acting)


Ordering Code: PEV-18A-2D-X-Y-Z 2

Torque 3-5 Nm

Coil EC-19A
1
127.3

19
TECHNICAL DATA
105

Max.Operating pressure: 350 bar


Rated flow: 320 l/min
46.0 Hex.
Cavity-Tooling: 18A-2
Locating
Shoulder Installation torque: 200-215 Nm
M48x2.0
Weight:(with Coil) 1.49 kg
(without Coil) 1.25 kg
Fluids-Temperatures: -40 to 120 ℃
79.5

Leakage at P of 140 bar


2
Approximately 50cc/minute maximum
Typical hysteresis less than 4% of
rated current at 10 bar pressure
1 drop - Pulse Width Modulated(PWM)
UNIT:mm
Recommended PWM frequency
Typical Metering Preformance (① ②) 60-150 HZ, application dependent,
350 140 HZ typical
P:14 bar
300
Coils must be ordered separately
Flow-Q(l/min)

250
2 Ports、22 Watt. Coil 19 mm tube
200

150
X OPTIONS
100
Normally-Closed,No Reverse Flow
50
09 Energized,Nose-in,Side-out Operation
0
(24 V) 100 200 300 400 500 600 Y OPTIONS
(12 V) 200 400 600 800 1000 1200
Command Current, mA N Non-adjustable
Typical Pressure Drop (② ①)
18 M Manual Override
15
Push Style
12 P Manual Override
P=bar

9
FLOW
6 Z
NOMINAL CAPACITY
3
3200 0-320 LPM
0 60 120 180 240 300 360
Flow-Q(l/min)
Rev.210128 B.352.214.E

You might also like