Documment Number (Rev.) Comments: Project: PETROBRAS 78 (P-78)
Documment Number (Rev.) Comments: Project: PETROBRAS 78 (P-78)
ITEM
1) I-DE-3010.2G-1225-540-TH5-014 (0)
I-DE-3010.2G-122 I-DE-3010.2G-
5-540-TH5-014_0_01_Review 1225-540-TH5-
014_0_Re
As per I-ET-3010.00-1200-800-P4X-013_G, item 9.4.4: The lower process tap nozzle for transmitters shall be positioned
viewComments.xls
BUYER
OPEN
200 mm below the minimum value of the range of interest to ensure that the instrument is sensitized throughout the
2) I-DE-3010.2G-1225-540-TH5-014 (0)
measuring range. Please, adjust level transmitters nozzles accordingly or verify with process team the alarm/interlock
levels.
BUYER
To achieve item 7.4.3, 7.4.5 and 7.4.7 of I-ET-3010.1M-1200-800-P4X-005, as the nozzles for oil level are in the same
OPEN
3) I-DE-3010.2G-1225-540-TH5-014 (0) elevations, the level gauge shall be SIDE-SIDE magnetic type. Also, please inform that LG is magnectic type in the nozzle
table (nozzles 4A/B) as per TQF-P78-KES-DD-TOP-IIA-0011 and I-FD-3010.2G-1415-814-KES-104_A.
BUYER
OPEN
Please notice that the level instruments do not cover all indicated control/interlock setpoints.. Therefore, please adjust all
4) I-DE-3010.2G-1225-540-TH5-014 (0)
level nozzles to cover all level setpoints.
SELLER
OPEN
5) I-DE-3010.2G-1225-540-TH5-014 (A)
I-DE-3010.2G-12
P78 Topside I-DE-3010.2G-
5-540-TH5-014_A_01_Review
Equipment Documentation Templ 1225-540-TH5-
014_A_Re
viewComments.xls
I-DE-3010.2G-12
P78 Topside I-DE-3010.2G-
5-540-TH5-014_A_01_Review
Equipment Documentation Templ 1225-540-TH5-
014_A_Re
viewComments.xls
According to I-DE-3010.2G-1225-944-KES-002 [A], the condensate levels for V-UC-1225001A-01 are:
HHLL = 2760.0 mm
HLL = 1716.0 mm
NLL = 1194.0 mm
LLL = 672.0 mm
LLLL = 150.0 mm
According to I-DE-3010.2G-1225-540-TH5-014 [A], the elevation of high pressure tap of LITs (nozzles 7B and 7D) are 175
mm, higher than LLLL = 150.0 mm.
BUYER
OPEN
6) I-DE-3010.2G-1225-540-TH5-014 (A)
According to I-DE-3010.2G-1225-540-TH5-014 [A], the elevation of low pressure tap of LITs (nozzles 7A and 7C) are 1100
mm, lower than HHLL = 2760.0 mm.
In order to calibrate the LITs and sound alarms (HHLL and LLLL) on HMI screens and afterwards proceed with safety
interlock functions, the span of LITs shall be greater than HHLL-LLLL (2760.0 - 150.0 = 2610.0 mm).
The nozzles 7A/7B/7C/7D shall be revised in order to attend the span of LITs.
The nozzles 7B and 7D shall postioned, at the limit of vessel construction (lower than elevation 150.0 mm) slightly above
tangent line.
According to TQF-P78-DD-TOP-IIA-0011, LG-1225005A/B shall be magnetic type. Being magnetic type, the LG nozzles
BUYER
OPEN
I-DE-3010.2G-1225-944-KES-002 [A] presents LG-1225005A as REFLEX type. Please revise P&ID accordingly.
SELLER
OPEN
8) I-DE-3010.2G-1225-540-TH5-014 (B)
I-DE-3010.2G- I-DE-3010.2G-
1225-540-TH5- 1225-540-TH5-
014_B_02 014_B_Re
_Revie viewComments.xls
SELLER
wComments.pdf
OPEN
9) I-DE-3010.2G-1225-540-TH5-014 (C)
I-DE-3010.2G- I-DE-3010.2G-
1225-540-TH5- 1225-540-TH5-
014_C_02 014_C_Re
_Revie viewComments.xls
SELLER
wComments.pdf
OPEN
I-DE-3010.2G- I-DE-3010.2G-
1225-540-TH5- 1225-540-TH5-
014_D.pdf 014_D_Re
viewComments.xls
I-DE-3010.2G- I-DE-3010.2G-
1225-540-TH5- 1225-540-TH5-
014_D.pdf 014_D_Re
viewComments.xls
SELLER
OPEN
11) I-DE-3010.2G-1225-540-TH5-014 (E)
540-TH5-014-
Position Nozzles 4A and 4B on the same side as a Level Gauge will be installed.
13) I-DE-3010.2G-1225-540-TH5-014 (F)
SELLER RESPONSE:- NOZZLES 4A AND 4B ARE ON THE SAME. REFER NOZZLE ORIENTATION.
F.docx
SELLER
OPEN