VDA n.

º: VDA-P78-TH5-0016 KEPPEL PETROBRAS

Issued by: Déborah Marinhp Rafael Zeilmann


Project: PETROBRAS 78 (P-78)
Checked by: Ana Luisa Formosinho André Luis

Released by: Vitor Freitas Maurício Madureira

Document STATUS: Status by Petrobras


COMMENTS ADDED
COMMENTS
STATUS
ITEM

ITEM

Documment Number (Rev.) Comments


BY:
SELLER
OPEN

1) I-DE-3010.2G-1225-540-TH5-014 (0)

I-DE-3010.2G-122 I-DE-3010.2G-
5-540-TH5-014_0_01_Review 1225-540-TH5-
014_0_Re
As per I-ET-3010.00-1200-800-P4X-013_G, item 9.4.4: The lower process tap nozzle for transmitters shall be positioned
viewComments.xls
BUYER
OPEN

200 mm below the minimum value of the range of interest to ensure that the instrument is sensitized throughout the
2) I-DE-3010.2G-1225-540-TH5-014 (0)
measuring range. Please, adjust level transmitters nozzles accordingly or verify with process team the alarm/interlock
levels.
BUYER

To achieve item 7.4.3, 7.4.5 and 7.4.7 of I-ET-3010.1M-1200-800-P4X-005, as the nozzles for oil level are in the same
OPEN

3) I-DE-3010.2G-1225-540-TH5-014 (0) elevations, the level gauge shall be SIDE-SIDE magnetic type. Also, please inform that LG is magnectic type in the nozzle
table (nozzles 4A/B) as per TQF-P78-KES-DD-TOP-IIA-0011 and I-FD-3010.2G-1415-814-KES-104_A.
BUYER
OPEN

Please notice that the level instruments do not cover all indicated control/interlock setpoints.. Therefore, please adjust all
4) I-DE-3010.2G-1225-540-TH5-014 (0)
level nozzles to cover all level setpoints.
SELLER
OPEN

5) I-DE-3010.2G-1225-540-TH5-014 (A)
I-DE-3010.2G-12
P78 Topside I-DE-3010.2G-
5-540-TH5-014_A_01_Review
Equipment Documentation Templ 1225-540-TH5-
014_A_Re
viewComments.xls
I-DE-3010.2G-12
P78 Topside I-DE-3010.2G-
5-540-TH5-014_A_01_Review
Equipment Documentation Templ 1225-540-TH5-
014_A_Re
viewComments.xls
According to I-DE-3010.2G-1225-944-KES-002 [A], the condensate levels for V-UC-1225001A-01 are:
HHLL = 2760.0 mm
HLL = 1716.0 mm
NLL = 1194.0 mm
LLL = 672.0 mm
LLLL = 150.0 mm

According to I-DE-3010.2G-1225-540-TH5-014 [A], the elevation of high pressure tap of LITs (nozzles 7B and 7D) are 175
mm, higher than LLLL = 150.0 mm.
BUYER
OPEN

6) I-DE-3010.2G-1225-540-TH5-014 (A)
According to I-DE-3010.2G-1225-540-TH5-014 [A], the elevation of low pressure tap of LITs (nozzles 7A and 7C) are 1100
mm, lower than HHLL = 2760.0 mm.

In order to calibrate the LITs and sound alarms (HHLL and LLLL) on HMI screens and afterwards proceed with safety
interlock functions, the span of LITs shall be greater than HHLL-LLLL (2760.0 - 150.0 = 2610.0 mm).

The nozzles 7A/7B/7C/7D shall be revised in order to attend the span of LITs.

The nozzles 7B and 7D shall postioned, at the limit of vessel construction (lower than elevation 150.0 mm) slightly above
tangent line.

According to TQF-P78-DD-TOP-IIA-0011, LG-1225005A/B shall be magnetic type. Being magnetic type, the LG nozzles
BUYER
OPEN

shall be aligned to level transmitters considering LGs magnetic SIDE-SIDE type.


7) I-DE-3010.2G-1225-540-TH5-014 (A)

I-DE-3010.2G-1225-944-KES-002 [A] presents LG-1225005A as REFLEX type. Please revise P&ID accordingly.
SELLER
OPEN

8) I-DE-3010.2G-1225-540-TH5-014 (B)

I-DE-3010.2G- I-DE-3010.2G-
1225-540-TH5- 1225-540-TH5-
014_B_02 014_B_Re
_Revie viewComments.xls
SELLER

wComments.pdf
OPEN

9) I-DE-3010.2G-1225-540-TH5-014 (C)

I-DE-3010.2G- I-DE-3010.2G-
1225-540-TH5- 1225-540-TH5-
014_C_02 014_C_Re
_Revie viewComments.xls
SELLER

wComments.pdf
OPEN

10) I-DE-3010.2G-1225-540-TH5-014 (D)

I-DE-3010.2G- I-DE-3010.2G-
1225-540-TH5- 1225-540-TH5-
014_D.pdf 014_D_Re
viewComments.xls
I-DE-3010.2G- I-DE-3010.2G-
1225-540-TH5- 1225-540-TH5-
014_D.pdf 014_D_Re
viewComments.xls

SELLER
OPEN
11) I-DE-3010.2G-1225-540-TH5-014 (E)

I-DE-3010.2G- I-DE-3010.2G- ABS_ABSG-13-


1225-540-TH5- 1225-540-TH5- 4715563-I-CS-BRC-
014_E_02 014_E_Re 10859-
SELLER

_Revie viewComments.xls 2021_B.docx


OPEN

12) I-DE-3010.2G-1225-540-TH5-014 (F)


wComments.pdf
I-DE-3010.2G-122 I-DE-3010.2G-
ABS_ABSG-13-
5-540-TH5-014_F_02_Review 1225-540-TH5-
4715563-I-CS-BRC-
014_F_Re
10859-2021-B_I-
viewComments.xls
DE-3010.2G-1225-
BUYER
OPEN

540-TH5-014-
Position Nozzles 4A and 4B on the same side as a Level Gauge will be installed.
13) I-DE-3010.2G-1225-540-TH5-014 (F)
SELLER RESPONSE:- NOZZLES 4A AND 4B ARE ON THE SAME. REFER NOZZLE ORIENTATION.
F.docx
SELLER
OPEN

14) I-DE-3010.2G-1225-540-TH5-014 (G)


I-DE-3010.2G-
1225-540-TH5-
014_G_Re
viewComments.xls