Professional Documents
Culture Documents
Cooling Element - Bordos - Thermoelectric - Units
Cooling Element - Bordos - Thermoelectric - Units
C L I M AT E C O N T R O L S Y S T E M S
COOLING UNITS
173
Cooling Units Introduction
174 ■ Fandis
Cooling Units Introduction
THERMOELECTRIC UNITS
Thermoelectric unit is a solid-state device, which can operate as a heat pump to transfer heat
utilizing the Peltier effect. These thermoelectric air conditioners represent a cost-effective solution for
cooling electronic equipment housed in small enclosures to provide reliable performance without the
use of CFC’s.
DC THERMOELECTRIC UNITS
DOUBLE EFFECT
Heating and cooling conversion by
reversing polarity
COOLING UNITS
QUIET OPERATION
Compressor-free and no moving parts,
except for the fan
REFRIGERANT FREE
No dangerous fluids thanks to Peltier
effect cooling system
IP55
High protection against wet and dusty
conditions
Fandis ■ 175
Cooling Units Introduction
AC THERMOELECTRIC UNITS
Designed for enclosure in industrial settings, the AC cooling unit fit an integrated
AC power supply system on the outer cover, saving internal space and avoiding
additional thermal load inside the unit.
DESIGN
Corrosion-resistant stainless steel
construction
176 ■ Fandis
TCU 50 Thermoelectric units
50W DC air-air
General specifications
• Panel through mounting, see mounting cut-out. Fixing with M5 ISO screws (not supplied).
Suitable for any plate thickness
• Plastic parts in PC/ABS alloy, self-extinguishing, according to UL 94V-0
• Sealing gasket made of closed cell polyethylene foam
• Shielded and self-lubricating ball bearing fans
• Standard color grey RAL 7035
Technical data
Rated Rated Max Operating Rated
Model Cooling Power Weight Approvals
Voltage Current Current Temp. Range VoltageRange
W V A A °C V Kg
TCU501240IP55-7035 57 12 V d.c. 5.0 5.8 -20 ~ +70 7 ~ 13 5.39 CE;
TCU502440IP55-7035 57 24 V d.c. 2.4 2.8 -20 ~ +70 10 ~ 27.6 5.41 CE;
COOLING UNITS
Technical drawing Mounting cut-out
±
60
55 Te = 25 °C Qc = - 1.9331 ∆T + 57.2
50
45
Cooling Power [W]
40
35
30
25
20
15
10
5
0
0 2 4 6 8 10 12 14 16 18 20 22 24 26 28 30 32
∆T = Te - Ti [°C]
Fandis ■ 177
TCU 100 Thermoelectric units
100W DC air-air
General specifications
• Panel through mounting, see mounting cut-out. Fixing with M5 ISO screws (not supplied).
Suitable for any plate thickness
• Plastic parts in PC/ABS alloy, self-extinguishing, according to UL 94V-0
• Sealing gasket made of closed cell polyethylene foam
• Shielded and self-lubricating ball bearing fans
• Standard color grey RAL 7035
Technical data
Rated Rated Max Operating Rated
Model Cooling Power Weight Approvals
Voltage Current Current Temp. Range VoltageRange
W V A A °C V Kg
TCU1002440IP55-7035 101 24 Vd.c. 4.7 5.7 -20 ~ +70 17 ~ 27 7.39 CE;
TCU1004840IP55-7035 101 48 Vd.c. 2.4 3.0 -20 ~ +70 34 ~ 54 7.37 CE;
110
100 Te = 25 °C Qc = -2.881 T + 101.4
90
80
Cooling Power [W]
70
60
50
40
30
20
10
0
0 2 4 6 8 10 12 14 16 18 20 22 24 26 28 30 32 34 36 38
T=Te - Ti [°C]
178 ■ Fandis
TCU 200 Thermoelectric units
200W DC air-air
General specifications
• Panel through mounting, see mounting cut-out. Fixing with M5 ISO screws (not supplied).
Suitable for any plate thickness
• Plastic parts in PC/ABS alloy, self-extinguishing, according to UL 94V-0
• Sealing gasket made of closed cell polyethylene foam
• Shielded and self-lubricating ball bearing fans
• Standard color grey RAL 7035
Technical data
Rated Rated Max Operating Rated
Model Cooling Power Weight Approvals
Voltage Current Current Temp. Range VoltageRange
W V A A °C V Kg
TCU2002440IP55-7035 201 24 Vd.c. 9.5 11.5 -20 ~ +70 17-27 Vd.c. 14.06 CE;
TCU2004840IP55-7035 201 48 Vd.c. 4.8 6.0 -20 ~ +70 34-54 Vd.c. 14.01 CE;
COOLING UNITS
Technical drawing Mounting cut-out
±
±
220
200 Te = 25 °C Qc = -5.4271 T + 201.4
180
160
Cooling Power [W]
140
120
100
80
60
40
20
0
0 2 4 6 8 10 12 14 16 18 20 22 24 26 28 30 32 34 36 38 40
T=Te - Ti [°C]
Fandis ■ 179
TCU 200 AC Thermoelectric units
200W AC air-air
General specifications
• Panel through mounting, see mounting cut-out. Fixing with M5 ISO screws (not supplied).
Suitable for any plate thickness
• Stainless steel external cover
• Sealing gasket made of closed cell polyethylene foam
• Shielded and self-lubricating ball bearing fans
• Terminal block connection
Technical data
Rated Input Max Input Operating
Model Cooling Power Weight Approvals
VoltageRange Power Power Temp. Range
W V W W °C Kg
TCU200AC40-SIP 201 88-264 Va.c. 245 306 -20 ~ +50 16.61 CE;
N° 8 HOLES Ø 5.5
224.3
Warm side
305±0.5
160±0.5
291+- 10
Cabinet wall
99.8
Cold side
290 276
140±0.5
347 312.5 276 +- 10
291±0.5
220
200 Te = 25 °C Qc = - 6.5797 ∆T + 201.09
180
160
Cooling Power [W]
140
120
100
80
60
40
20
0
0 2 4 6 8 10 12 14 16 18 20 22 24 26 28 30 32 34
∆T = Te - Ti [°C]
180 ■ Fandis
Cooling Units Introduction
THERMOELECTRIC MODULES
Thermoelectric modules are semiconductor-based electronic components that work as a small
heat pump. These modules are the core system of thermoelectric units and combine low energy
requirements with the ability to provide both cooling and heating from the same element, by
reversing the polarity of DC voltage.
DOUBLE EFFECT
Heating and cooling conversion by
reversing polarity
COOLING UNITS
REFRIGERANT FREE
No dangerous fluids thanks to Peltier
effect cooling system
Fandis ■ 181
TM Thermoelectric modules
single stage thermoelectric modules
General specifications
The thermoelectric module (or Peltier module) is an electronic component which works as
a small heat pump. This is the core system of the cooling unit and it is made up of a certain
number of couples of semiconductor material with different electric charge. These couples are
laid down between two ceramic plates, like a “sandwich”, that act as a mechanical support and
also as an electrical insulator. Applying a DC electric current to the module, the system starts to
work cooling a side of the module and warming the opposite one.
• Lead wires length: standard 150mm
• Tinned lead wires ends
• Lead wires insulation: PVC
• Sealing: silicone or epoxy resin
Technical data
Max Max Max Cooling Max Temp. Max Operating
Model
Current Voltage Power Differential Temp.
A V W °C °C
TM1-1273050-HXHP 5.0 15.2 47.1 66 125
TM1-1274060-HXHP 6.0 15.3 60.0 67 125
specifications
40 40
30 30
Th Th
3.8
2.9
Tc Tc
Cooling power vs temperature difference Cooling power vs current
65
65
60
60 TM1-1273050-HXHP
55 55
TM1-1274060-HXHP
50 50
Cooling Power [W]
45 45
Cooling Power [W]
40 40
35 35
30 30
25 25
20 Th = 25 C
20 T=0
15 15
10 10
5
5
0
0 5 10 15 20 25 30 35 40 45 50 55 60 65 70 0
0 0,5 1 1,5 2 2,5 3 3,5 4 4,5 5 5,5 6
T=Th - Tc [°C]
Current [A] 3
182 ■ Fandis
RC-TCU Accessories - thermoelectric units
drip trays
General specifications
Drip trays are stainless steel accessories to be mounted on the thermoelectric units. They are
used to collect the condensate generated on the cold heat sink inside the enclosure.
Suitable for vertical installation of the thermoelectric unit
ffStainless steel
Technical data
Model Description
COOLING UNITS
FOR TCU50 /TCU100 Technical drawing
140 147
129 136
136.5
121
121
Ø 5.5 Ø 5.5
48.5
48.5
20
27.5
Ø 10 Ø 10 55
151 158 60
140
Ø 5.5
55
49
65
20
27.5
Ø 10
55
296 60
Fandis ■ 183
Cooling Units Introduction
346
TCU200 / TCU200AC - max. height with drip tray
346
184 ■ Fandis
Fandis
■
185
COOLING UNITS