PRD Sizing As Per API 520 (Steam)
DOC.NO REV NO 0
PROJECT NO PAGE No. 2 of 3
PROJECT TITLE
BASIS
CALCULATION OBJECTIVE
CALCULATION BASIS
CALCULATION METHDOLOGY
ASSUMPATIONS
SOFTWARE USED
CONCULSIONS
REFERENCES
ATTACHMENTS
PRD Sizing as per API 520 (Part 1) (Steam)
PROJECT TITLE
INTRODUCTION
The Spreadsheet provide calculations for PRV sizing for steam
INPUT
PSV PSV or Rupture disc
Psv and RD not Are Psv and Rupture disc is in combination?
10 Overpressure
70000.0 Kg/h Q Required Flowrate
338.0 °C T Relieving Tempeature
640.4 °F T Relieving Tempeature
11032 Kpag Pset Pressure Set point
0 Kpag Pback Constant Backpressure
0.9 ¯ Z Compressbilty Factor (Z=1)
18 M Molcular Weight
1 ¯ Kb Vendor Provided Value
OUTPUT
0.975 ¯ Kd Effective Coefficent Discharge( PSV=0.975 ,RD= 0.62)
1 Kc Combination Correction factor for installations with RD
1103.2 Kpag Overpressure
11133.325 Kpaa P1 Upstream reliveing pressure
1.00 KN Correction Factor for Napier Equation
1.00 Ksh Superheat steam Correction Factor
Steam is saturated
1226.1 mm2 A Orifice Area Calculated
1.90 inch2 A Orifice Area Calculated
L Selected Orifice
2.853 inch2 A Orifice Area for Selected Orifice
REV 0
PAGE NO. 3 OF 3
LIST 1
PSV
Rupture disc
LIST2
Psv and RD IN
Psv and RD not
overpressure
10
16
21
RD= 0.62)
s with RD