Download as xlsx, pdf, or txt
Download as xlsx, pdf, or txt
You are on page 1of 9

PROJECT NUMBER

PROJECT TITLE

DOCUMENT

PRD Sizing as per API 520 (Steam)

DATEREV
REASON FOR REVISION
PREPCHKDAPPDAPPD
Doc No Page 1 of REV.O
3
PRD Sizing As Per API 520 (Steam)
DOC.NO REV NO 0
PROJECT NO PAGE No. 2 of 3
PROJECT TITLE
BASIS

CALCULATION OBJECTIVE

CALCULATION BASIS

CALCULATION METHDOLOGY

ASSUMPATIONS

SOFTWARE USED

CONCULSIONS

REFERENCES
ATTACHMENTS
PRD Sizing as per API 520 (Part 1) (Steam)

DOC. NO. REV


PROJECT NO PAGE NO.

PROJECT TITLE

INTRODUCTION
The Spreadsheet provide calculations for PRV sizing for steam

INPUT
PSV PSV or Rupture disc
Psv and RD not Are Psv and Rupture disc is in combination?
10 Overpressure
70000.0 Kg/h Q Required Flowrate
338.0 °C T Relieving Tempeature
640.4 °F T Relieving Tempeature
11032 Kpag Pset Pressure Set point
0 Kpag Pback Constant Backpressure
0.9 ¯ Z Compressbilty Factor (Z=1)
18 M Molcular Weight
1 ¯ Kb Vendor Provided Value

OUTPUT
0.975 ¯ Kd Effective Coefficent Discharge( PSV=0.975 ,RD= 0.62)
1 Kc Combination Correction factor for installations with RD
1103.2 Kpag Overpressure
11133.325 Kpaa P1 Upstream reliveing pressure
1.00 KN Correction Factor for Napier Equation
1.00 Ksh Superheat steam Correction Factor

Steam is saturated
1226.1 mm2 A Orifice Area Calculated
1.90 inch2 A Orifice Area Calculated
L Selected Orifice
2.853 inch2 A Orifice Area for Selected Orifice
REV 0
PAGE NO. 3 OF 3

LIST 1
PSV
Rupture disc

LIST2
Psv and RD IN
Psv and RD not

overpressure
10
16
21
RD= 0.62)
s with RD

Table 1- Standred Effective Orifice Area


List 1
Orifice designation
D
D
E
F
G
H
J
K
L
M
N
P
Q
R
T
Non-standard size
1- Standred Effective Orifice Areas According API 526

Orifice area, in2


-
0.110
0.196
0.307
0.503
0.785
1.287
1.838
2.853
3.600
4.340
6.380
11.050
16.000
26.000