Professional Documents
Culture Documents
TSS 24.07.2018-9 PDF
TSS 24.07.2018-9 PDF
NOTE:-
1. ALL DIMENSIONS ARE IN MM. & LEVELS ARE IN METER.
5300
5. DRAWING IS NOT TO BE SCALED ONLY WRITTEN
DIMENSION SHOULD BE FOLLOWED .
4100
4036
6.. CLEAR COVER TO MAIN REINFORCEMENT SHALL BE
3300
FOR COLUMN - 40MM & FOOTING -75MM, BEAM -25MM,
SLAB-15 MM
MOMENT .
10. THE MIX FOR ALL R.C.C. WORK SHALL BE M-25 (1:1:2)
RB-1 RB-2 RB-3 RB-4 RB-5 13. BUILDING IS DESIGNED FOR EARTHQUAKE LOAD
OF ZONE III.
C2 C2
C1 C2 C2 C1 14. THE DESIGN WIND SPEED HAS BEEN CONSIDERED
RB-21
AS 50 M/SEC.
RB-26
RB-32
RB-29
15. DURING EXCAVATION IF HARD ROCK IS
S-1 S-1 S-1 ENCOUNTERED THEN DEPTH OF EXCAVATION CAN BE
S-1 LOWERED FOR LACING OF FOUNDATION ,AFTER
CONSULTATION OF STRUCTURAL CONSULTANT.
RB-22
RB-31
RB-23
RB-25
RB-28
S-1 S-1 S-1 S-1
RB-27
RB-30
RB-24
S-1 S-1
S-1 S-1 LEV 3.3
Roof Beam Size - (230x300) typ ROOF BEAM LAYOUT WITH SLAB SCHEDULE
DRAWING NO : TSS/STR/09
SCALE:
PRODUCED BY AN AUTODESK EDUCATIONAL PRODUCT