TOTAL SOLUTIONS

Tyco History

Fire suppression for valued assets


High value facilities warrant dedicated specialist protection
GASEOUS FIRE whether it is a Data Centre, Museum, Art Gallery, POG
facility, Marine, Power or Industrial facility. Our passion to
SUPPRESSION protect drives us to create solutions to help you safeguard
you valued people, property and operations.

SYSTEMS

Greener and more A clean, non-conductive


environmentally-friendly and natural fire
fire protection suppression agent

Custom-engineered clean agent INERGEN introduces the proper


system for 3MTM NovecTM 1230, mixture of gases into a room
delivering a clear, colourless lowering the oxygen content below
low-odour agent with zero ozone the level that supports combustion
depletion and safe for use in but allows a person to breathe, and
occupied areas. Available as a 25 as no fogging on discharge occurs,
and now a 42 bar system, this evacuation is not inhibited.
already versatile system with the The INERGEN system is particularly
additional benefit of high pressure useful for suppressing fires in
release and multi-valve technology hazards where an electrically
is suitable for application which contain multiple risks and non-conductive medium is essential
benefit from protection via a central storage location. or desirable; where clean-up of
other agents presents a problem; or where the hazard is
normally occupied and requires a non-toxic agent.
TOTAL SOLUTIONS

Controlled release, Naturally occurring protection


three innovations for environments containing
working together electrical components

The i-FLOW system is i3 is part of the inert gases family, a


patented technology 50/50 mix of Nitrogen and Argon.
incorporating three innovations Acting as all inert gas systems, it
working together: the i-FLOW valve, the i-FLOW check works by reducing the oxygen in a
valve and the i-FLOW matrix cylinder racking design. protected enclosure to a level
that will not sustain combustion.
i-FLOW valves regulate the agent release flow, eliminating The benefit of using Nitrogen and
peak pressure spikes associated with conventional orifice Argon is that they are naturally
systems. The check valve ensures the integrity of the occurring in the atmosphere, so
system by preventing leakage and can be placed in any upon discharge there is no global
orientation to connect multiple components. Finally the warming or ozone depleting potential. As i3 is stored and
i-FLOW’s matrix cylinder racking design offers maximum discharged as a gas, it is ideal for environments containing
space utilisation in conventional or unconventional spaces. electrical components.

Fire suppression by
heat removal Ideal for non-occupied
spaces
FM-200 works by removing the element
of heat from a fire to interrupt combustion A naturally occurring compound with
and suppress a fire. It is non-conductive so no measurable environmental impact,
there is no effect on energized electrical making it ideal for non-occupied
components upon discharge, and with zero spaces* that can be totally flooded
ozone depleting potential, it has proved to by a suppression agent for maximum
be the most widely selected replacement effect, CO2 is collected, stored and
for Halon 1301. processed for use as a fire suppression
solution. Providing personnel are trained
in the hazards, safety precautions and
operation of CO2 systems during
and after discharge, CO2 is an
economical fire suppression solution for protecting
numerous industrial applications.*

*CO2 is lethal at design concentrations and must not be used in occupied areas or
areas where human exposure is possible.