FRGP/FRIE/FXCA/FXDA
commissioning in case of
3+3+0 and 3+0+0 (A or F-
type) configurations
Information is classified as
Internal
Public X
Customer Specific
1. Validity............................................................................................................................................3
2. Compatibility / Dependencies to other products.............................................................................3
3. Keywords........................................................................................................................................3
4. Summary ........................................................................................................................................3
5. HW / SW requirements...................................................................................................................3
6. Detailed description........................................................................................................................4
7. Corrective actions...........................................................................................................................4
Contact:
Summary of changes:
1. VALIDITY
Product Category 1
Flexi WCDMA BTS software X
EUBB UltraSite
UltraSite
N.A
3. KEYWORDS
4. SUMMARY
Purpose of this document is to describe how 3+3+0 and 3+0+0 configurations can be
utilized by using single FRGP / FRIE RF modules in RU20 EP1 SW level.
This Technical Support (TSN) Note applies only to 3+3+0 and 3+0+0 configurations build
by using only one FRGP / FRIE modules.
Workaround solution described in this TSN does not require any additional actions in RNC
or OSS.
Correction for this will be implemented in two phases: WN6.0 MP4 and final correction in
WN7.0. These two phases are described more accurately in the end of the document.
5. HW / SW REQUIREMENTS
SW REQUIREMENTS:
RU20 EP1
HW REQUIREMENTS:
FSMD/E
FRGP
FRIE
With WN6.0 MP3.x SW in 3+0+0 or 3+3+0 BTS configurations a faulty antenna mapping
was selected and due to that not all cells went onto air because not all TX and RX
resources in the RF were activated.
When using 3+3+0 or 3+0+0 A- or F-type configurations with one FRGP / FRIE RF module
and RU20 EP1 SW level, following workaround solution must be applied
Site must be configured first as 3+3+3 configuration
Only needed amount of cells are activated from RNC ( 3+3+0 or 3+0+0 )
Two optical fibers are needed between System and RF module
Two Local Cell Groups are needed to configure
36CE are reserved for common channels in second LCG
NOTE !
7. CORRECTIVE ACTIONS
WN6.0 MP4 correction for the problem is that the antenna mapping selection logic is
changed so that when there is 3 cells from one/two or three branch in use the correct
antenna mapping is always selected in configurations 3+0+0, 3+3+0 and 3+3+3.
Phase 2: WN7.0
Final correction will be implemented RAN2162: RP3 Dynamic Allocation. RAN2162
enables to commission both 3+3+0 and 3+0+0 configuration normally without the
workaround solution described above.
After RAN2162 feature implementation only one optical fiber is needed when using 3+3+0
or 3+0+0 configurations.
The information in this document is subject to change without notice and describes only the product
defined in the introduction of this documentation. This documentation is intended for the use of Nokia
Siemens Networks customers only for the purposes of the agreement under which the document is
submitted, and no part of it may be used, reproduced, modified or transmitted in any form or means
without the prior written permission of Nokia Siemens Networks. The documentation has been
prepared to be used by professional and properly trained personnel, and the customer assumes full
responsibility when using it. Nokia Siemens Networks welcomes customer comments as part of the
process of continuous development and improvement of the documentation.
The information or statements given in this documentation concerning the suitability, capacity, or
performance of the mentioned hardware or software products are given “as is” and all liability arising
in connection with such hardware or software products shall be defined conclusively and finally in a
separate agreement between Nokia Siemens Networks and the customer. However, Nokia Siemens
Networks has made all reasonable efforts to ensure that the instructions contained in the document
are adequate and free of material errors and omissions. Nokia Siemens Networks will, if deemed
necessary by Nokia Siemens Networks, explain issues which may not be covered by the document.
Nokia Siemens Networks will correct errors in this documentation as soon as possible. IN NO EVENT
WILL NOKIA SIEMENS NETWORKS BE LIABLE FOR ERRORS IN THIS DOCUMENTATION OR
FOR ANY DAMAGES, INCLUDING BUT NOT LIMITED TO SPECIAL, DIRECT, INDIRECT,
INCIDENTAL OR CONSEQUENTIAL OR ANY LOSSES, SUCH AS BUT NOT LIMITED TO LOSS OF
PROFIT, REVENUE, BUSINESS INTERRUPTION, BUSINESS OPPORTUNITY OR DATA, THAT
MAY ARISE FROM THE USE OF THIS DOCUMENT OR THE INFORMATION IN IT.
This documentation and the product it describes are considered protected by copyrights and other
intellectual property rights according to the applicable laws.
The wave logo is a trademark of Nokia Siemens Networks Oy. Nokia is a registered trademark of
Nokia Corporation. Siemens is a registered trademark of Siemens AG.
Other product names mentioned in this document may be trademarks of their respective owners, and
they are mentioned for identification purposes only.