Engineering Change Order: Intent

You might also like

Download as pdf or txt
Download as pdf or txt
You are on page 1of 1

ECO Number 158371

ENGINEERING CHANGE ORDER Supplement No.


Page 1 of 1

ECO TYPE ECO CLASSIFICATION MODELS IMPLEMENTATION METHOD


A. EMERGENCY - SHIP NO ENGINES W/O THIS CHANGE NEW RELEASE VHP 16CYL ALL DATE:
B. PRIORITY REVISIONS IDENTIFIED PARTS SEE INTENT SECTION
C. MUST BE AVAILABLE FOR CHANGES CONFIGURATION RULES NOTIFY CSA
D. ROUTINE CHANGES ENGINE OUTLINE OR CONNECTIONS AFFECTS TORSIONAL ANALYSIS
E. DOCUMENT ONLY TECH DATA RELEASE SERVICE BULLETIN REQUIRED?
F. RESTRICTED RELEASE - PROTOTYPE CE MARK COST REDUCTION: $
INTENT:
CURRENTLY IN NOTES OF DRAWING S-SHEET WIRING DIAG. CALLS FOR 16GA WIRE. OPERATORS ARE USING 14 AWG OR 16 AWG BECAUSE THE
DIFFERENT CONDUIT ASSEMBLIES FOR THE UNIT CALL 14AWG WIRE SIZES FOR THE CIRCUIT. ALL HARNESSES AND ASSEMBLIES SHOULD USE 14 AWG
WIRE FOR THE CIRCUIT.
THIS ECO REVISES THE S-SHEET TO CHANGE 16 AWG WIRE TO 14 AWG WIRE IN NOTES.
NOTE:

HS/ECCN CODES: (PRC) PART RELATIONSHIP CODES:


"A"=ASSIGNED, "V"=VERIFIED, "R"=REVISED, "N"=N/A (DWI-02-1041) "1"=YES, "2"=NO, "3"=YES IF, N=ENG. OBS. (DWI-02-1032)
STOCK DISPOSITION
E
N R P PRODUCTION SERVICE P
PART NUMBER H C SUPERSEDED PART
ITEM E E DESCRIPTION R C
NEW & REVISED PART(S) S C NUMBER(S)
W V C C
N USE REWORK SCRAP USE REWORK SCRAP

WIRING DIAGRAM. IGNITION, CSA


1 S-06563-50 X V V 1) CHANGED NOTE 1. “ALL W.E.D. WIRING TO BE #14
AWG RATED 600 VOLTS”.
WIRING DIAGRAM. IGNITION, CSA
2 S-06563-59 X V V 1) CHANGED NOTE 1. “ALL W.E.D. WIRING TO BE #14
AWG RATED 600 VOLTS”.

WORK REQUEST: ER62717 APPROVED BY: C. NELSON APPROVED BY: G. PAVON


REQUESTED BY: S. SMITH 10/17/12 APPROVED BY: R. OLSEN APPROVED BY:
PREPARED BY: A. GARNICA 08/19/15 APPROVED BY: D. OURADNIK APPROVED BY:
CHECKED BY: J. KOLBACH 08/21/15 APPROVED BY: T. SINTKOWSKI ISSUED BY:
Form 0135-A 12-2-2009