Professional Documents
Culture Documents
Nwi Roj 208 465 1
Nwi Roj 208 465 1
EPKUNEL 2010-09-28 B
INDEX
1 GENERAL ...........................................................................................2
1.1 Background .........................................................................................2
1.2 Scope ..................................................................................................2
1.3 Statement of Compliance ....................................................................2
1.4 Purpose ...............................................................................................2
1.5 Revision History ..................................................................................2
1.6 Abbreviations and Definitions ..............................................................3
1.6.1 Definitions............................................................................................3
1.6.2 Abbreviations.......................................................................................3
1.7 References ..........................................................................................3
2 INTRODUCTION .................................................................................4
2.1 Compatibility with E-GEM magazine ...................................................4
3 HARDWARE ARCHITECTURE ..........................................................5
3.1 Overview .............................................................................................5
4 FUNCTIONAL DESCRIPTION ............................................................6
4.1 Switch Subsystem ...............................................................................6
4.2 Front-End Interface .............................................................................6
4.3 Management CPU ...............................................................................6
5 INTERFACE DESCRIPTION ..............................................................7
5.1 Internal Interfaces................................................................................7
5.2 EXTERNAL INTERFACES..................................................................7
5.2.1 Ethernet 10/100Base-T Management Interface ..................................7
5.2.2 Ethernet 10/100/1000Base-T Switching Interfaces .............................7
5.2.3 Ethernet 1000Base-X Interfaces .........................................................7
5.2.4 RS232 interface...................................................................................7
6 MECHANICAL DESIGN ......................................................................8
6.1 Front Connectors.................................................................................8
6.2 Back Connectors ...............................................................................10
6.3 Environment ......................................................................................10
6.4 Reliability ...........................................................................................10
6.5 Power consumption...........................................................................10
6.6 EMC/ Safety ......................................................................................10
Ericssonwide Internal
PRODUCT DECSRIPTION 2 (10)
Prepared (also subject responsible if other) No.
EPKUNEL 2010-09-28 B
1 GENERAL
1.1 Background
1.2 Scope
The document describes new NWI-E board but only to a certain degree. The
board design itself is owned by Extreme Networks.
The board has passed through several compliance tests. Please see
references [ 1 ] through [ 7 ] for more details.
1.4 Purpose
The document describes the NWI-E structure and its functionality on a high
level.
B 2010-09-22 Correcting information that stated that Ethernet connectors to the backplane
existed. They do not. Added information regarding interfaces.
Ericssonwide Internal
PRODUCT DECSRIPTION 3 (10)
Prepared (also subject responsible if other) No.
EPKUNEL 2010-09-28 B
1.6.1 Definitions
1.6.2 Abbreviations
GND GrouND
1.7 References
[ 2 ] Extreme Networks NWI-E 450A Declaration of Conformity 2/174 01-ROJ 208 465/1 Uen A
[ 4 ] AS/NZS Test Report (CISPR 22:2006) 2/174 24-ROJ 208 465/1 Uen A
EPKUNEL 2010-09-28 B
2 INTRODUCTION
The NWI-E implements the BSC IP network interface function for the BSC
(L2/L3 switching).
The PBA is designed to be hosted in both GEM and E-GEM magazine. The
only interface connected to the backplane is the power connection.
EPKUNEL 2010-09-28 B
3 HARDWARE ARCHITECTURE
3.1 Overview
EPKUNEL 2010-09-28 B
4 FUNCTIONAL DESCRIPTION
The following main functional blocks are present in NWI-E:
Switch subsystem
Front-End Interface
Management CPU
NWI-E uses one Broadcom XGS BCM56500 24-port Gigabit Ethernet switch
controller. It supports the functions, features and performance levels specified
by Broadcom by this chipset.
NWI-E has 13 DensiShield connectors on its front panel. Eleven of them are
used as single 10/100/1000Base-T Ethernet ports. One is used as out-of-
band Ethernet port and the other one is used as serial console port.
The BCM1122 CPU controls the local switch fabric and handles packets that
require CPU involvement. It has many interfaces that attach to local devices.
The most important control paths are:
The PCI bus which connects to the switch fabric BCM56500 chip
The Ethernet GMII/MII interface which connects to the BCM5241
single PHY
The I2C bus which connects to several local devices
EPKUNEL 2010-09-28 B
5 INTERFACE DESCRIPTION
The internal interfaces are not described as the design and usage of these
outside the scope of this document.
Eleven Ethernet standard interface connections are provided via front panel
for traffic switching. All interfaces are independent and fully compliant with
IEEE 802.3 and 802.3u.
The serial console port of the NWI-E uses DensiShield connector with cable
TSR 491 616. The default settings are:
Baud rate: 9600
Data bits: 8
Stop bit: 1
Parity: None
Flow control: XON/XOFF
Ericssonwide Internal
PRODUCT DECSRIPTION 8 (10)
Prepared (also subject responsible if other) No.
EPKUNEL 2010-09-28 B
6 MECHANICAL DESIGN
The front panel width is 15 mm, see product structure in reference [ 8 ] for
more information on the front panel.
NWI-E has 13 DensiShield connectors and two SFP cages on its front panel.
Ericssonwide Internal
PRODUCT DECSRIPTION 9 (10)
Prepared (also subject responsible if other) No.
EPKUNEL 2010-09-28 B
EPKUNEL 2010-09-28 B
6.3 Environment
6.4 Reliability
The maximum power consumption is 62 W, but during max 1 Gbps traffic the
nominal power consumption is 40 W.