Professional Documents
Culture Documents
VT-BDN 02-03-2023
VT-BDN 02-03-2023
Rectification:
MEL action reverted back to normal, FIM 34-45 fault tree 815 Rev 131 st 30 Jan 2023 followed TCS bite procedure bite
revealed top out faulty as per block 22 upper TCAS antenna replaced as per AMM 34-45-02/401 Rev 131 dt 20 Jan 2023,
securily of installation and operation check found satisfactory.
MEL revoked
P/N: 7514081-901
ON S/N: ANE60003
OFF S/N: ANE47269
Cert: 8130-3/1198976/ LO-047721, dt 12-05-2022
VT-BDN
Date: 02.03.2023 ATA Ch.: 75 SI. No: 21223
Inspection snag:
During C/O W/P – 16689 found 9 O’clock position (IP bleed value) acoustic alternator damaged. Required replacement.
Rectification:
IP bleed value acoustic alternator replaced as per AMM Ref 75-32-10/401 Rev-131, Dated 20 Jan 2023.
Acoustic alternator
P/N – ED 101208 (Qty -01)
R/N – 7157823-00 Dated -19-10-2022
Screw
P/N – U756263 (Qty -08)
R/N – MC – 31873 Dated -30-12-2021
Installation of security found satisfactory. Tag attached.
VT-BDN
Date: 02.03.2023 ATA Ch.: 72 SI. No: 21224
Inspection snag:
During C/O W/O – 16689, found one of the bolt on shroud fairing damaged. Required to be replaced.
Rectification:
Shroud fairing attachment bolt replaced as per AMM ref 72-03-01/401 Rev-131, Dated 20 Jan -2023.
P/N – AS20911 (Qty 01)
R/N – CN 88382536-0010-001 Dated-02-02-17
security of installation checked & formed satisfactory. Tag attached.