Download as pdf
Download as pdf
You are on page 1of 6
Osmo1 Single-Sample Miro-Osmometer The latest innovation in osmometry for clinical labs. A sit: Pp ed GS Rae, Why osmolality determination matters. Osmolality s a fundamental measurement of the total solute concentration of body fluids including whole blood, serum, plasma, urine, feces, sweat, and tissue homogenate, and its directly related to osmotic pressure. Osmotic pressure i of vital importance in biology as it relates to fluid balance, nutrient transfer, and waste removal processes in cellular organisms The value of osmolality testing in clinical laboratories. (Osmolality is a valuable clinical tool used in the diagnosis and treatment of patients. Its a quick and effective test help evaluate the body's water balance or its ability to produce and concentrate urine, investigate low sodium levels chyponatremia), detect the presence of toxins in the body, and monitor osmotically active drug therapies such {as mannitol, used to treat cerebral edema, It can also help. ‘monitor the effectiveness of a treatment for @ condition found to be adversely affecting a person's osmolal a Why freezing point depression is the preferred method. There are many methods for measuring concentration of solutions including: specific gravity, refractive index, and conductivity. Freezing point osmolality, however, is the only method which is truly independent from the size, shape, and other physical characteristics of the liquid solution. This is why freezing point depression is the industry-preferred solution and the gold standara in clinical laboratories around the world, Theory of freezing point depression for ‘osmolality determination. Advanced Instruments’ osmometers utilize the industry preferred freezing point depression method to determine the osmolality of body fluids. When solutes (particles) are issolved in a solvent (water), the freezing point of the solution is lowered compared to that of the solvent alone. ‘As more solute is added, the freezing point decreases further. Therefore, by precisely measuring the freezing point of the solution, the osmolality (\@. concentration) can be determined. Freezing point osmometry can ascertain volatiles in solutions such as CO, ammonia, ‘and alcohol unlike vapor pressure osmametry. The industry standard for osmometers. Worldwide. The Osmol™ value. Your laboratory deserves best-in-class technology. Introducing the Osmo! Single-Sample Micro-Osmometer. Osmotis ideally suited for clinical laboratories that prefer to directly draw and test small sample volumes and are looking for an osmometer that offers ease of use, accurate and precise results, and the security and efficiency of electronic data management. Easy to us + Factory calibrated and ready to test + Calibration only required if quality controls out of specification, or after maintenance + One-step direct sampling, simply aspirate sample and load sampler into the instrument + Fast, 90-second test time * Color-coding, in combination with on-screen messages, provides clear indication of instrument status Flexible and convenient workflow. + Only requires 20 pi. of sample + Selectable 2- or 3-point calibration to satisty CLIA calibration veritication requirement + Operating range up to 2,000 mOsm/kg H,0 to cover all of the samples your laboratory may encounter + Replacement sampler plunger wire included with every Micro-Sample Test Kit to optimize instrument performance Ethernet and USB port (located on ‘the back of the instrument) Allows for easy LIS connectivity and export of data Consumable box Micro-Sample Test Kit fits in accessory compartment to maximize available bench space and make sampler tins and cleaners easily accessible Includes replacement plunger wire for optimal performance On-board printer For easy printing and archiving of test results Freezing chamber (located inside) Hinged cover provides easy access to solenoid for maintenance Ease-Fject™ Sampler Convenient sample intraduction, eliminates loss of sample On-board sampler holder Convenient place to store sampler when not in use Operating cradle Guides sampler into freezing chamber Integrated barcode scanner Touchscreen Built-in barcode scanner allows _Intuitive, color-coded menu- for traceable sample identification driven operating system, with ‘and reduces transcription errors multi-language capability splays test results and enables enhanced data management EE a MIO) SR RP SN ee we Sa SY Secure and efficient electronic data management. Intelligent user interface. + Interactive and intuitive touchscreen with ‘2 menu-driven operating system displaying test results, user 1D, sample IO, date, time, test progress bar, instrument status, and errors + Multi-language capability + Sampler tip countdown for inventory management eT Built-in quality control. + Can issue warnings when quality control is out of range so users can re + Allows tracking of quality control data over time with exportable Levey-Jennings chart + Able to set custom range limits for QC samples + Audit control ensured with events database + Stores the last 1,000 test records and 10,000 events Electronic data management for bid SUES security and efficiency. + Enables laboratories to comaly with Statistics for 3 samples" HIPAA regulations + Password protected user accounts, with ability Mean = 2897 mOsm/kg H20 Loli sample ID and user ID to test results, or Standard Deviation = 0.6 nOsm/Kg H20 Improved traceability Coefficient of Variation = (20% + Supervisor login with abiliy to set restrictions and password expiry + Bidirectional LIS via Ethernet connectivity Re EXIT + Provides statistical analysis (mean, standard deviation, and coefficient of variation + USB for easy data export Parts and supplies Part number Description Instrument. OSMO1__Osmol Single-Sample Micro-Osmomster ‘Osmometer calibration standards and reference solutions ‘SMAO0S __SO mOsmy/Kg callration standard 0x2 mL. SMAQBS___850 mOsm/kg callbrtion standard, 1Ox2 mL ‘3MAZ0O__ 2000 mOsm/ug calibration standard 10x2 mL ‘3MAO29___Clnivol™290 reference solution, 1x2 mL. AOI linearity set 5x5 mL ‘Osmometer control solutions 3MA028_Protinl™ protein-based serum controls (S-Love Sm vials) ‘SCAOGS__ Renol” urine osmolality controls @-Lew Sm vials) ‘Osmometer calibration standards (not included) LAQTI___100. mOsm calibration standard 1x5 ml |368020 200 mOsm ealbration standard, 1x2 mL ‘3MAQAO 400 mOsm caratin standard 2m. ‘SLAQS| 500 mOsm ealloration standard 1S mL ‘LAOS 900 mOsm caloration standard 1Ox5 mL. ‘SHAOGO 1000 mOsm calibration standard TOx2 mL SLAISI___1500 mOsm callbration standard, 1Ox5 ml. ‘Osmometer supplies and accessories 138300 Micro-Sample Test Kt 500 tips, 00 cleaners, ‘Osmo1 Single-Sample Micro-Osmometer specifications! Sample type Aqueous solution Semple volume 20 74, Test time 90 seconds Semple capacity Single sample Unite mOsm/ke HO Resolution | mOsm/kg HO ange 0 f0 2000 mOsm/kg HO Recuracy™ (0 t0 400 mOsm/kg H.0: <2 mOsm/kg H:O from nominal value 15D) > 400 ta < 1800 mOsm/kg HO: 0.5% mOsm/kg HO from nominal value (15D) 221500 to 2000 mOsm/kg HiO: <1 mOsm/kg HO from nominal vale 'SD) Precision? (within un) 0 to 400 mOsm/kg H,0: Standard deviation <2 moOsmyka HO > 400 to < 1500 mOsm/i«g HO: Coefficient of variation <0.5% mOsm/kg HO 321500 to 2000 mOsm/kg H.0: Costicient of variation <8 mOsm/kg iO Temperature effects? Less than 1 mOsm/kg H:0 per 5°C (3°) ambient temperature charge ‘Communications On-board printer, USB 20 Type A ports @), USB 20 Type 8 ports (0, Ethernet 10/100, RJAS connector port Supported languages Simplified Chinese, Czech, Danish, English, French, German, Greek italia, Japanese, Korean, Portuguese, Russian, Slovak, Spanish, Swedish, Turkish Storage temperature 20°C to VASC CAF to HSE) plunger wire Electrical voltage 100 10240 VAC (50/60 H2) ‘3MO825__20 pL Ease-Flect Sampler ower consumption 60 Watts FLAB3S Reorder thermal printer paper, 5/oka Dimensions (© x W x H) 38 cm x 86cm x 8 em GS" x14" x15 FLAB36 Thermal printer paper, 2/0k3 iNet weight 60 kg 033 Ibs) Optimal performance requires quality test supplies. ‘Advanced struments offers 2rtinal and Renal Contois which ‘imie srum and urine to ensure optimal systom performance and faceurate tert results, Renal and Protna ats CAP requirement ‘hat laboratories ran two contros a two eliferent concentrations dlly or with each batch of samples and reagent Shipping weight 74 kg (25 tbs) ‘Warranty One-year limited warranty on workmanship and parts C€ ol @ 4 Emme ‘subject to change “operating Condens Tamoerature 6° 1 35°C (EA to 957), 30 te BOX Bie. amavcen GES iisrennrs ‘Two Technology Way | Norwood, MA 02062 stance inerumentsproscts te aunsbl tom worldwide dtrovtor Hot ine" Technical are Advanced insrumens provides arr comorenansa customer sence a8 techs scopor 2018 Advancad Instruments Advances, Hot Lig Intro Potina Reno Ease, Oxo are rademari of Advance Instruments, lather rademaves re the property of he resect companiee

You might also like