Survey: "3D- CRT Photon Planning Competency Evaluation"


Reviewer: Clinical Instructors (HAAS, Beth)
Reviewee: Students (Curry, Meshan)
Survey Period: 3/27/2023
Completed: 3/27/2023 10:42:02 AM CT

1. Select the external beam photon planning competency from the drop down menu below:

Lymphoma

2. If Other competency, please specify the type here:

Rt Axilla Nodes

about:blank 1/3
5/11/23, 12:23 PM Typhon Group - EASI System
3. Please assign each task a score of Satisfactory or Unsatisfactory.
Unsatisfactory in any essential task constitutes competency failure.
The student will repeat the competency at a later date.

Discusses the plan prescription with the physician. Satisfactory [2 pts]


Additional Comments:  DIscussed the dose with the physician
and learned the reason for treating 4000cGy/20 fxs which is
different than other fractionation schemes used in our
department

Loads the patient imaging studies into the planning computer. Satisfactory [2 pts]

Contours the appropriate anatomy on the image data set. Satisfactory [2 pts]
Additional Comments:  Meshan does a great job contouring

Successfully places the isocenter using simulation data. Satisfactory [2 pts]


Additional Comments:  Isocenter was placed correctly in CT

Correctly generates plan using blocks, wedges, segmented Satisfactory [2 pts]


fields. Additional Comments:  PTV created based on physician
instuctions and the block was generated based on a margin
from the PTV. Segments created to develop a more
homogenous isodose distribution.

Generates plan with appropriate weighting. Satisfactory [2 pts]

Generates plan with appropriate energies. Satisfactory [2 pts]


Additional Comments:  Meshan looked at different energies
and settled on 10 MV for both beams

Accurately generates/evaluates plan DVH or composite DVH Satisfactory [2 pts]


(for correct # of fractions).

Communicates effectively with physician for plan review and Satisfactory [2 pts]
makes changes as requested. Additional Comments:  The physician wanted to know the skin
max dose. Meshan had to create a skin contour and provide
him with the information he requested.

Exports/Prints appropriate plan data. Satisfactory [2 pts]

Performs a verification calculation for plan MU settings. Satisfactory [2 pts]


Additional Comments:  Rad calc done successfully

Enters correct parameters for the patient chart. Satisfactory [2 pts]


Additional Comments:  Transfer of plan to ARIA with
appropriate notes and instructions done

Performs pretreatment checks/calculations. N/A


Additional Comments:  This is a therapist task in our
department

Utilizes respiratory gating information to determine field N/A


parameters. Additional Comments:  Gating was not performed for this
patient

Observes patient treatment. Satisfactory [2 pts]

Mean: 2.00 of 2  Points: 26  Score: 100.0%

4. Overall rating:

Pass [2 pts]
If applicable, please specify reason for failure:  Meshan did a great job with this plan

Mean: 2.00 of 2   Points: 2  Score: 100.0%

about:blank 2/3
5/11/23, 12:23 PM Typhon Group - EASI System

Total points for all rating scale questions: 28


Mean percentage score for all rating scale questions: 100.0%
(Each main question equally weighted)
Responses as of 5/11/2023 12:21:41 PM CT

about:blank 3/3