Download as docx, pdf, or txt
Download as docx, pdf, or txt
You are on page 1of 5

Alat kimia air

No NAMA ALAT SPESIFIKASI BRAND

Thermo Fisher
1 DuraProbe 4-Electrode Conductivity Cell, MiniDIN Connector, 1.5m Cable
Scientific
For Use With (Equipment) Star A112, Star A122, Star A212, Star A215, Star A222, Star A322, Star A325, Star A329, Versa Star and Versa Star Pro Conductivity Meters
Sensor Types 4 Electrode Graphite Cell
Cell Constant 0.55 cm^-1
Type 4-Electrode Conductivity Cell, Mini-Din Connector
Connector Types 8-pin Mini-DIN
Description DuraProbe 4-Cell Lab and Field Conductivity Probe, 1.5m
Diameter (English) Body 0.59 in.
Diameter (Metric) Body 12 mm
Length (English) Cable 5 ft.
Length (Metric) Cable 1.5 m
Material Epoxy-Body
Measurement Ranges 10 µS/cm to 200 mS/cm
Min. Immersion 35 mm
Storage Method Store in distilled or deionized water between measurements; for overnight or long-term storage, thoroughly rinse and store dry
Probe Conductivity probe with built-in ATC temperature sensor
Unit Size Each

pH Electroda for
2 EUTECH Thermo Scientific
pH Meter

Parameter : pH
Range : 0 to 13 pH
Temperature range Liquid : 0 to 100
Junction Type Internal : Annular ceramic
Reference Type : Ag/AgCl
Sealed/Refilable : Refilable
Reference Junction : Single
Refiling Reference Electrolyte : ECRE001
Dimensions (Shaft) : 130 x 12 mm
Cable Length : 1m
Connector : BNC
Description : General Purpose glass-body pH electrode with protective sensor guard. Suitable for samples with low
temperature measurements. Comes with 10 ml refiling electrolyte
Used with : All pH meters with BNC input connector

Portable Multi-
3 HQ2100 Portable Multi-Meter with Conductivity Electrode, 1 m Cable
Meter

Accessories Included Automatic : No


Buffer Recognition Backlight : Yes
Barometric Pressure Measurement Cable : Yes
Length : Automatic compensation of DO when using an LDO or LBOD probe 1 m
Calibration : Demal (1D/ 0.1D/ 0.01D);
: Molar (0.1M/ 0.01M/0.001M);
: NaCl (0.05%; 25μS/cm; 1000μS/cm; 18mS/cm); Standard sea water; User
: defined
Calibration Intervals/Alerts/Reminder: Certifications: : Off, selectable from 2 hours to 7 days
Conductivity Measurement Range: : CE, FCC, ISED, RCM, KC, ETL Verified: US DOE/ NRCan Energy Efficiency, RoHS Yes
:
:

Page 1 Page 5
No NAMA ALAT SPESIFIKASI BRAND

Conductivity measurement: Temperature correction: : None; Linear; NaCl Non-Linear Natural Water.

Custom Calibration Standards: Data Export: : USB connection to PC or USB storage device (limited to the storage device capacity). 10,000 data points

Data Memory: : Automatic in Press to Read Mode and Interval Mode. Manual in Continuous Read Mode. 63 mm x 97 mm x 220 mm

Data Storage: : Up to 3 parameters at a time, dependent on HQ model

Dimensions (H x W x D): Display: : Continuous / Auto-stabilisation ("press to read") / At Interval

Display Lock Function: Display Type: : 536x336 Mono-TFT

DO Measurement Range: DO Resolution: Enclosure Rating: : 0.1 - 20.0 mg/L (ppm), 1 - 200% saturation

GLP Features: : Date; Time; Sample ID; Operator ID, Calibration

Inputs: : IP67 (with battery compartment installed)

Instrument: : Date; Time; Sample ID; Operator ID, Calibration

ISE Direct Measurement Range: ISE Electrode Calibration: K : No

Languages: : Portable

Measurement method: : No

Model: : No

mV Measurement at Stable Reading: mV Measurement Rang : Yes

Pocket Pro+
4 Pocket Pro+ Multi 2 Tester for pH/Cond/TDS/Salinity with Replaceable Sensor
Multi 2 Tester

Accuracy: : Cond: ±1%


Backlight: : Yes

Battery Requirements: : 4, AAA

IP Rating: : IP67

Manual Languages : English, French, German, Italian, Spanish

Operating temperature range : 0 - 50 °C

Parameter : pH, Conductivity, TDS, Salinity, Temp

Range: : Temp: 0.0 to 50°C

Resolution: : Cond: 0.1 μS/cm from 0.0 to 199.9 μS/cm; 1 μS/cm from 200 to 1999 μS/cm; 0.01 mS/cm from 2.00 to 19.99 mS/cm

Sample Volume: : 9 mL

TDS Factor: : adjustable; 0.71 default

Warranty: : 12 months

What's included?: : Includes: tester, 4 AAA batteries, lanyard, calibration solutions and quick start guide.

Benchtop Meter, Benchtop Dual Input, Multi-Parameter Meter - pH, Conductivity, Optical Dissolved Oxygen,
5
Multi ORP, and ISE

Automatic Buffer Recognition: : Yes


Backlight: : #

Barometric Pressure Measurement: : Automatic compensation of DO when using an LDO or LBOD probe

Calibration Intervals/Alerts/Reminder: : Off, selectable from 2 hours to 7 days

Compliance Certifications: : CE.WEEE

Page 2 Page 5
Conductivity measurement: : Yes

Conductivity Measurement Range: : 0.01 μS/cm - 200.0 mS/cm

Conductivity resolution: : 0.01 μS/cm - 0.1 mS/cm upon selected measuring range

Contents: : Meter Only

Custom Calibration Standards: : Yes

Data Memory: : 500 records/FIFO

Data Storage: : Automatic, GLP ISO compliant reading data stored with calibration details.

Dimensions: : 859 x 175 x 235 mm

INTELLICAL
Intellical ISENH318101 Ammonia (NH₃) Ion Selective Electrode (ISE) with Calibration
6 AMMONIA I
Reagents Pack
ANALYSIS PKG

Page 3 Page 5
No NAMA ALAT SPESIFIKASI BRAND

Accuracy: : ±0.02 mV or 0.05%, whichever is greater


Cable Length: : 1m
Electrode Type: : Non-Refillable Gel Reference Element, Replaceable membrane
ISA Required: : 4447169
Junction: : Double Annular Junction
Kit?: : Yes
Length: : 175 mm
Method Type: : Laboratory: Non-Refillable Gel Reference Element, Replaceable membrane
Parameter: : Ammonia
Probe Type: : Standard
Range: : 0.01 mg/L (5 x 10-7 M) - 14 g/L (1 M) NH3-N
Reference Type: : Ag/AgCl
Resolution: : Selectable up to 4 significant digits

INTELLICAL
Intellical ISENO318101 Nitrate (NO3−) Ion Selective Electrode (ISE) with Calibration
7 NITRATE
Reagents Pack
ANALYSIS PKG

Accuracy: : ±0.02 mV or 0.05%, whichever is greater


Cable Length: : 1m
Electrode Type: : Non-Refillable Gel Reference Element, Replaceable membrane
ISA Required: : 4447169
Junction: : Double Annular Junction
Kit?: : Yes
Length: : 175 mm
Method Type: : Laboratory: Non-Refillable Gel Reference Element, Replaceable membrane
Parameter: : Nitrate
Probe Type: : Standard
Range: : 0.01 mg/L (5 x 10-7 M) - 14 g/L (1 M) NH3-N
Reference Type: : Ag/AgCl
Resolution: : Selectable up to 4 significant digits

INTELLICAL
8 FLUORIDE Intellical ISEF12101 Fluoride (F−) Ion Selective Electrode (ISE) with Calibration Reagents
ANALYSIS PKG Pack

Accuracy: : ±0.02 mV or 0.05%, whichever is greater


Cable Length: : 1m
Electrode Type: : Non-Refillable Gel Reference Element, Replaceable membrane
ISA Required: : 4447169
Junction: : Double Annular Junction
Kit?: : Yes
Length: : 175 mm
Method Type: : Laboratory: Non-Refillable Gel Reference Element, Replaceable membrane
Parameter: : Fluoride
Probe Type: : Standard
Range: : 0.01 mg/L (5 x 10-7 M) - 14 g/L (1 M) NH3-N
Reference Type: : Ag/AgCl
Resolution: : Selectable up to 4 significant digits

Page 3 Page 6
Page Page 7
4