YZ VEIKI-VNL No. 8301/VNL icp _¥LECTRIC LARGE LABORATORIES Ltd, Page 1 of 9 TYPE TEST CERTIFICATE OF DIELECTRIC PERFORMANCE ‘Test object: Composite insulator for rated voltage of 110 kV Designation: EUROINS H. 110. 120. 1250. T. T. 191. 12256E Manufacturer; FCI Composite Insulator Ltd ‘Tapidszecs6; Pest str 17. 2251 - HUNGARY ‘Tested for: FCI Composite Insulator Ltd. Date of tests: 10" October 2014 Tested by: VEIKI-VNL Ltd. - Budapest HUNGARY Project ID: ‘NFL - 01/2014-M8 Order/Contract: NFL - 01/2014 -M8 / 09" October 2014 ‘Test specification: IEC 61109:2008 Sub-Clause 11.1 Tests performed: The test object, constructed in accordance with the description, drawings and photographs incorporated in this report has been subjected to dry lightning impulse withstand voltage and wet power-frequency withstand voltage tests. ‘Test results: ‘The test object fulfilled the relevant requirements of the standard. This Type Test Certificate has been issued by VEIKI-VNL Lid. in accordance with above mentioned specifications. The Certificate applies only to the test object. The responsibility for conformity of any product having the same designations with that tested rests with the Manufacturer. ‘This Certificate comprises 11 sheets in total (9 numbered pages and 2 drawings). Only integral reproduction of this document is permitted without written permission from VEIKI-VNL Ltd VEIKI-VNL Ltd. is an independent testing laboratory. “LL Budapest, Tamas Forg6 Csaba Homok "Dr. Laszlé Varga 04" December, 2014 responsible for the test. supervised by managing director ~H-1158 Budapest, Vasgolyé u. 2-4, HUNGARY E-mail: vnl@vnl.hu Phone: +36-1-417 3157 www. vni.hu Fax: +36-1-417 3163 Vz VEIKI-VNL No. 8301/VNL l=jpep _©LECTRIC LARGE LABORATORIES Ltd. Page 2 of 9 TEST CERTIFICATES OR REPORTS ISSUED BY VEIKI-VNL LTD. Type Test Certificate of Complete Type Test This certificate provides the verification of all the rated characteristics of the equipment as assigned by the manufacturer, by means of the performance of all type tests specified by the standards. ‘Type Test Certificate of Dielectric Performance This certificate provides the verification of all dielectric ratings, by means of the performance of the appropriate type tests specified by the standards. Type Test Certificate of Temperature-Rise Performance This certificate provides the verification of temperature-rise limits together with measurement of the ‘main circuit resistance, by means of the performance of the appropriate type tests specified by the standards, Type Test Certificate of Short-Circuit / Making and Breaking Performance ‘This certificate provides the verification of rated characteristics with respect short-circuit and/or making and breaking performance, by means of the performance of the appropriate type test specified by the standards, ‘Type Test Certificate of Switching Performance This certificate provides the verification of the switching ratings (e.g. capacitive current), by means of the performance of the appropriate type tests specified by the standards. Prototype Test Report Prototype tests are required to verify the suitability of the materials and method of manufacture for composite insulators defined by relevant ANSI standards. Design Test Report According to IEC standard: The design tests are intended to verify the suitability of the design, materials and method of manufacture (technology) of composite insulators. According to ANSI standard: The design tests are intended to verify the insulators electrical and mechanical characteristics that depend on its size and shape. ‘Type Test Report This report provides the verification of the rated characteristics of the equipment as assigned by the manufacturer, by means of the performance of the appropriate type tests specified by the standards, for type tests not indicated above. Development Test Report This report is issued when the test is intended only to provide the Client with information about the performance of the equipment. The tests ate performed in accordance with relevant standards, but are not intended to verify compliance of the equipment. Control Test Report This report is issued for tests performed on equipment in service, or removed from service. Tests are performed, and compliance is evaluated in accordance with relevant standards ‘Test Report ‘Test report is issued in all cases not listed above, Ye VEIKI-VNL No. 8301/VNL jkef ¥LECTRIC LARGE LABORATORIES Ltd. Page 3 of 9 Ratings/characteristics assigned by the manufacturer: Designation: EUROINS H. 110. 120. 1250. T. T. 19L. 12256E Manufacturer: FCI Composite Insulator Ltd. Rated voltage (Uy 110kV Arching distance: 1040 mm Dry lightning impulse withstand voltage: 550 kV pax Wet power-frequency withstand voltage: 230 kVins Specified mechanical failing load (SML): 120 KN ‘The tests were carried out in accordance with the following standards: IEC 61109:2008 Composite insulators for a.c. overhead lines with a nominal voltage greater than 1000 V- Definitions, test methods and acceptance criteria IEC 60060-1:2010 High voltage test techniques. Part 1: General definitions and test requirements TEC 60383-2:1993 Insulator strings and insulator sets for a.c. systems Requirements of manufacturer or purchaser: Wet power-frequency withstand voltage: 340 kVins List of manufacturer's drawings for identification of the test object: *12256-E *11815/D-E * Drawings are attached to the test report. Present at the test in charge of manufacturer or purchaser: Mr. Bertalan Juhasz FCI Composite Insulator Ltd. Viz VEIKI-VNL No. 8301/VNL Rey? + ©LECTRIC LARGE LABORATORIES Ltd. Page 4 of 9 TESTS PERFORMED ON THE TEST OBJECT No. | Description Relevant clauses of the standard T | Dry lightning-impulse withstand voltage test_| Sub-Clause 11.1 of IEC 61109:2008 Clause 9 of IEC 60383-2:1993 2 | Wet power-frequency withstand voltage test | Sub-Clause 11.1 of IEC 61109:2008 Clause 10 of IEC 60383-2:1993 DESCRIPTION OF THE TESTS Dry lightning impulse withstand voltage and wet power-frequency withstand voltage tests were performed according to the referred standards on one specimen of the composite insulator with two mounted arcing homs for rated voltage of 110 kV. The test object can be seen on Photo 1 and for the test arrangement on Photo 2. During the tests the ambient parameters wer Dry temperature: 21.1 °C Absolute humidity: 11.3 gim? Air pressure: 100.53 kPa Characterisation of the artificial rain: * Vertical and horizontal component of the rain 1.8-2 mm/min ¢ Resistivity of water 9500 Ocm 1 Dry lightning-impulse withstand voltage test Ll Test method and parameters The lightning impulse withstand voltage test were carried out in dry condition, The 50 % flashover voltage values were determined on positive and negative polarity with up and down test method according to Clause 9 of the standard IEC 60383-2:1993. The correction factor was K=0,9924 during the tests, The test circuit can be seen on the Figure | 12 Test results The determined 50 % flashover voltages: = 710.7 kV peak {+ 605.3 KV peak The calculated 10% flashover voltages: = 683.4 kVpeak / + 582.0 KVpcak ‘The calculated lightning-impulse withstand voltage was 582 kVpax Which was higher, than the requirement lightning-impulse withstand voltage of 550 kVpcai therefore the test object met the requirement of lightning impulse voltage test in dry condition. Vz VEIKI-VNL No. 8301/VNL fz =]fc7 __¥LECTRIC LARGE LABORATORIES Ltd. Page 5 of 9 2 Wet power-frequency withstand voltage test 2.1 Test method and parameters The power-frequency withstand voltage test was performed in the outdoor laboratory according to Sub-Clause 11.1 of the standard IEC 61109:2008, The power-frequency voltage test was carried out on one unit. The test voltage was 340 kVims corrected by meteorological factor. The test object shall withstand the test voltage for I minute without breakdown and without flashovers. The sample was pre wetted for 15 minutes before the test. The form of the artificial rain was drop. During the test the insulator was continuously wetted. After the withstand test on one unit the wet power-frequency flashover voltages test was carried out. The average values were calculated from five measured flashover voltages. ‘The correction factor was K=0.9931 during the withstand test. The test circuit can be seen on the Figure 2. 2.2 Test results During the wet power-frequency withstand voltage test at 360 kVins With a duration of 1 minute, neither breakdown nor flashovers occurred, therefore the test object met the requirement of power-frequency withstand voltage test in wet condition. ‘The obtained values are given in Tables 1, Table 1 The results of the wet power-frequency flashover voltage measurement No: Flashover voltage [kV] __] ih 356.2, a 360.2 3 361.2 4 361.2 = 352.1 Average: 358.2 Note: the voltages in this table are corrected with the calculated meteorological correction factor (K) Urabic=Unmeasurea!K VEIKI-VNL No. 8301/VNL VYz ELECTRIC LARGE LABORATORIES Ltd. Page 6 of 9 3 Uncertainty of measurements Measured parameter Uncertainty Lightning impulse measurement £25% Power-ftequency measurement £2.5% The uncertainty values given in this report are the standard deviation values multiplied by k=2. Measurement uncertainty was estimated according to the method described in the EA-4/ document. 4 Measuring devices used for the tests: No._ [Designation [Manufacturer [Type SIN Voltage divider MICAFIL [SDR 2000 138127-33 Impulse voltage measuring system _[DR. STRAUSS | TR-AS 200-12/2 _|972/2010 O) 2] E Voltage divider TUR MCF 407600 381066 [4] [Termination TUR WMUT3/H6 851459 [5] [Voltmeter TUR WMUT3 894966 vD Measuring system Gimp Impulse generator MICAFIL SH 11-24 [yD Voltage divider [1] [Measuring system | Dr.Srauss [2 a Figure 1 Measuring circuit for lightning impulse test. 42 VEIKI-VNL No. 8301/VNL Eb 7h ELECTRIC LARGE LABORATORIES Ltd. Page 7 of 9 pe sort i] co Tr 10/3kV FI M) ™M G G iS F2 \| oe 712 1/500 kV Trl; Tr2 Transformers CB1; CB2 Circuit breakers Fl; F2 Reactors M Motor G Generator VD Voltage divider [3] Term Termination [4] VM Voltmeter [5] Figure 2 Measuring circuit for power frequency test. IVE VEIKE-VNL No. 8301/VNL MELPED ELECTRIC LARGE LABORATORIES Ltd. Page 8 of 9 PHOTOS Photo 1 ‘Test arrangement for the dry lightning impulse withstand voltage test V4 VEIKE-VNL No. 8301/VNL ME if ELECTRIC LARGE LABORATORIES Ltd. Page 9 of 9 Photo 2 Test arrangement for the dielectric tests 4 | 2 | 2 | be HEE| "is drawings preprty of FCI Campouite Ltd Budsoest/Aangory anais no ate reraoicedor wae fe rsh any hen proved try wien agrenent ni on |OMENSIONS {rr} | |A |Section length 1250 |Arcing distance 1040 Leakage distance 2580 [- |WITHSTAND VOLTAGES fev] Lightning impulse dry 550 B \Power frequency wet 230 |MECHANICAL LOADS [kN] SML 120 rt |RTL 80 MASS kg] insulator 43 c ‘SHED NUMBER (pes. } Insulator 2/11 Tolerances of insulator acc. to 1EC 61109. |_ Catalogue number: EUROINS H. 110. 120. 1250. 7. T. 191. 12256E Designed by Checked by S Consultant ‘Approved by Filename | Date antalG Lichner Bognar A, uhasz & pazsse | 2010017 | F ea ] EUROINS® INSULATOR ng No 12256-E eee tailor macie solutions of pages 1] page 1 I i a | 1. dg. ~ hot ip galvanized min. 500g/sqm according to IEC 383. 4. fs ~ drop forged steel FCI Kompozi [sues it Szigi 8301 5 aaa wae TF mata IVNL ao vet 04 4} it Mig z ae [hia Dessgnes by ‘Checees By Wernsnop "aoproved by FST Bot wizxes 2 ‘steel ha. igh” Brbortet Kine? aognae' 3 arng dom reeTa=E [a tsp i FURUKAWA ARGNG HORT 1 areing horn body —[r|nnaaiye=e—[-a 1s aa By Fel even Teal i [iem| onesies Peal ov et "ele \S INSULATOR Lea "ef ae NBDE EL. T T Tr eo $ T T

You might also like