Technical Datasheet

7/20/2021

Model: AKA4460YXA

Product Description
Type: Reciprocating Compressors
Application: HBP - High Back Pressure
ProductDescription: R-134a/R-513A
Voltage/Frequency: 115V ~ 60Hz 100V ~ 50Hz
Version: N/A

Product Specifications
Performance

Ref rigeration Capacity Input Power (E) Ef f iciency


(R) (R) (R) (E) (E) EVAP AMBIENT RETURN LIQUID
Condition Test Voltage Btu/h kcal/h W (I) W Btu/Wh kcal/Wh W/W TEMP Condition TEMP GAS TEMP
ARI ( R- 513A) 115V ~ 60HZ 6593 1662 1932 894 7.38 1.86 2.16 7.2°C ( 45°F) 54°C ( 130°F) 35°C ( 95°F) 18.3°C ( 65°F) 46°C ( 115°F)

ARI ( R- 134a) 115V ~ 60HZ 6300 1588 1846 850 7.41 1.87 2.17 7.2°C ( 45°F) 54°C ( 130°F) 35°C ( 95°F) 18.3°C ( 65°F) 46°C ( 115°F)

General

Evaporating Temp. Range: -6.7°C to 12.8°C (20°F to 55°F)


Motor Torque: High Start Torque (HST)
Compressor Cooling: Fan

Mechanical

Weight: 41
Weight Unit of Measure: LB
Displacement (cc): 18.584
Oil Type: Polyolester
Viscosity (cSt): 32
Oil Charge (cc): 512

Electrical

Voltage Range (50 Hz): 90-110


Voltage Range (60 Hz): 103-127
Locked Rotor Amps (LRA): 48
Rated Load Amps (RLA 50 Hz): 0
Rated Load Amps (RLA 60 Hz): 9.5
Max. Continuous Current (MCC in Amps): 12.2
Motor Resistance (Ohm) - Main: .66
Motor Resistance (Ohm) - Start: 4.6
MotorType: CSIR
Overload Type:
Relay Type:

Agency Approval

cURus Recognized
Performance Data Sheet
AKA4460YXA

General
Model AKA4460YXA Unit of Measure Fahrenheit
Condition ARI (R-134a) Voltage/Frequency 115V ~ 60HZ
RETURN GAS 18.3°C (65°F) RETURN GAS MotorType CSIR

Performance Information
Condensing Temperature (°F)
EVAP TEMP (°F) 100 110 120 130 140
Btu/h 4060 3530 3060 2590 2040
Watts 574 592 600 594 573
20
Amps 7.43 7.60 7.68 7.65 7.49
Lb/h 57.8 52.9 48.6 43.5 36.7
Btu/h 4660 4100 3590 3080 2490
Watts 606 631 648 653 643
25
Amps 7.67 7.88 8.02 8.05 7.97
Lb/h 66.5 61.6 57.2 52.1 45.2
Btu/h 5350 4750 4200 3650 3020
Watts 635 668 693 708 708
30
Amps 7.89 8.15 8.33 8.44 8.43
Lb/h 76.7 71.7 67.2 62.0 55.1
Btu/h 6120 5480 4890 4290 3620
Watts 662 701 735 759 770
35
Amps 8.10 8.39 8.63 8.80 8.88
Lb/h 88.2 83.1 78.5 73.3 66.3
Btu/h 6960 6270 5630 4990 4270
Watts 686 732 773 806 827
40
Amps 8.29 8.63 8.92 9.16 9.31
Lb/h 101 95.6 91.0 85.7 78.7
Btu/h 7860 7120 6430 5730 4970
Watts 708 760 809 850 881
45
Amps 8.47 8.85 9.20 9.50 9.73
Lb/h 114 109 104 99.2 92.2
Btu/h 8800 8010 7260 6520 5700
Watts 729 786 841 891 931
50
Amps 8.64 9.06 9.47 9.84 10.1
Lb/h 129 124 119 114 107
Btu/h 9780 8930 8130 7320 6450
Watts 748 810 872 929 978
55
Amps 8.81 9.27 9.73 10.2 10.6
Lb/h 144 139 134 129 122

COEFFICIENTS CAPACITY POWER CURRENT MASS FLOW


C1 2.382485E+04 4.824307E+02 3.369828E+00 3.549330E+02
C2 5.529595E+01 3.827835E+00 1.338268E-01 5.482796E-01
C3 -4.798364E+02 -5.718293E+00 1.221579E-02 -7.693100E+00
C4 3.605990E+00 9.836078E-03 -7.673312E-04 4.156067E-02
C5 -4.526413E-01 -6.960173E-02 -1.853097E-03 -6.099490E-03
C6 3.746725E+00 1.049571E-01 5.316797E-04 6.432671E-02
C7 -1.474830E-02 3.018793E-04 3.763006E-06 -1.871895E-04
C8 -6.867588E-03 -8.707661E-04 8.647884E-07 1.093610E-05
C9 1.260477E-04 1.251932E-03 1.249010E-05 1.763469E-05
C10 -1.052312E-02 -5.453806E-04 -3.705206E-06 -1.889689E-04

Value = C1 + C2 * Te + C4 * Te^2 + C7 * Te^3 + (C3 + C5 * Te + C8 * Te^2) * Tc + (C6 + C9 * Te) * Tc^2 + C10 * Tc^3

Te = Evaporator Temperature
Tc = Condensing Temperature
Performance Data Sheet
AKA4460YXA

General
Model AKA4460YXA Unit of Measure Fahrenheit
Condition ARI (R-513A) Voltage/Frequency 115V ~ 60HZ
RETURN GAS 18.3°C (65°F) RETURN GAS MotorType CSIR

Performance Information
Condensing Temperature (°F)
EVAP TEMP (°F) 100 110 120 130 140
Btu/h 4250 3700 3210 2710 2130
Watts 603 622 631 625 602
20
Amps 7.59 7.76 7.84 7.81 7.65
Lb/h 69.9 64.0 58.7 52.7 44.4
Btu/h 4880 4290 3760 3220 2610
Watts 637 664 682 687 676
25
Amps 7.83 8.05 8.18 8.22 8.14
Lb/h 80.4 74.5 69.1 62.9 54.6
Btu/h 5600 4970 4400 3820 3160
Watts 668 702 729 744 745
30
Amps 8.06 8.32 8.51 8.61 8.61
Lb/h 92.7 86.7 81.2 75.0 66.6
Btu/h 6410 5730 5110 4490 3790
Watts 696 737 773 798 809
35
Amps 8.27 8.57 8.82 8.99 9.06
Lb/h 107 100 94.9 88.6 80.2
Btu/h 7290 6560 5890 5220 4470
Watts 721 770 813 847 870
40
Amps 8.47 8.81 9.11 9.35 9.50
Lb/h 122 116 110 104 95.2
Btu/h 8230 7450 6730 6000 5200
Watts 745 799 850 894 926
45
Amps 8.65 9.03 9.39 9.70 9.94
Lb/h 138 132 126 120 111
Btu/h 9210 8380 7600 6820 5960
Watts 766 827 885 937 979
50
Amps 8.82 9.25 9.67 10.0 10.4
Lb/h 156 149 144 137 129
Btu/h 10200 9340 8510 7660 6750
Watts 786 852 916 976 1030
55
Amps 8.99 9.46 9.94 10.4 10.8
Lb/h 174 168 162 155 147

COEFFICIENTS CAPACITY POWER CURRENT MASS FLOW


C1 2.493214E+04 5.071766E+02 3.440772E+00 4.291755E+02
C2 5.786590E+01 4.024180E+00 1.366442E-01 6.629651E-01
C3 -5.021374E+02 -6.011608E+00 1.247296E-02 -9.302292E+00
C4 3.773583E+00 1.034061E-02 -7.834855E-04 5.025406E-02
C5 -4.736783E-01 -7.317189E-02 -1.892110E-03 -7.375341E-03
C6 3.920859E+00 1.103408E-01 5.428730E-04 7.778215E-02
C7 -1.543374E-02 3.173639E-04 3.842227E-06 -2.263446E-04
C8 -7.186767E-03 -9.154313E-04 8.829945E-07 1.322364E-05
C9 1.319059E-04 1.316149E-03 1.275305E-05 2.132340E-05
C10 -1.101219E-02 -5.733554E-04 -3.783210E-06 -2.284962E-04

Value = C1 + C2 * Te + C4 * Te^2 + C7 * Te^3 + (C3 + C5 * Te + C8 * Te^2) * Tc + (C6 + C9 * Te) * Tc^2 + C10 * Tc^3

Te = Evaporator Temperature
Tc = Condensing Temperature