FUNCTION SAFETY AND HIMA INITIATION

SUMMARY

What is HIMA?
HIMA is the leading provider of smart automation solutions for functional safety.

1. HIMA’s products presentation


 HIMATRIX (The Small and Inexpensive Safety Controller)
 HIQUAD/ HIQUAD X: HIQuad X is a programmable electronic safety system
made by HIMA.
 HIMAX
 Planar 4

a) HIMATRIX:
HIMatrix non-redundant systems are certified for use up to SIL 3. They are native ethernet
and can be either compact or modular. HIMatrix systems are dedicated for small
applications because they have a limited number of I/Os (but they can have extension
modules).
The HIMatrix system family includes not only a modular controller (F60) but also a
comprehensive range of compact small controllers (like : F10 (obsolete), F20 (obsolete), F30,
F31 (obsolete), F35) and remote I/O modules (like : F1 DI 16 01, F2 DO 16 01..)

Compact PLCs are un-divided solid structures, generally non-expandable with a specific
number of inputs, and outputs.
Modular PLC is a rack-based system with individual Power supply, Processor, Various IO
modules, Extension units, mounted on one or more racks.

HIMATRIX F30
Specifications
Digital inputs 20
Analog inputs 0
Digital outputs 8
counters 2
Number of switch ports 4
Number of fieldbus interfaces 3

HIMATRIX F35
Specifications
Digital inputs 24
Analog inputs 8
Digital outputs 8
counters 2
Number of switch ports 4
Number of fieldbus interfaces 3

HIMATRIX F60
The F60 system is quite special, it’s a modular HIMatrix system.
Specifications
Number of switch ports 4
Number of fieldbus interfaces 2

b) HIQUAD/ HIQUAD X:
HIQuad X systems are certified for use up to SIL 3, they can have redundant: CPU,
communication and IOs. They are dedicated to small to medium applications.

HIQUAD H41 (the basic)


The H41X system family has a modular structure which includes an H41X base rack and can
be additionally equipped with an extension rack. The H41 PLC can manage up to 208 I/Os.

HIQUAD H51
The H51X system family has a modular structure which includes an H51X base rack and up to
16 extension racks. The H51 controller can manage several thousand.

Comparison between H41 and H51


H41 H51
Main Rack Processor NO YES
Separate I/O rack NO YES
Max communication module 2 10
redundant configuration YES YES
Total rack I/O 1 16
Total number of I/O modules 13 256

c) HIMAX:
HIMAX systems are systems with high availability designed for large and mission-critical
applications.
This safety PLC has the particularity of never stopping whatever the modifications requested
during operation: hardware, program or task modifications. There is therefore no longer any
compromise between safety, availability and profitability.

Himax system advantages:

 High availability (Safety non-stop)


 It offers an opening to all HIMA PLCs (HIQUAD, HIMATRIX) and can be used as a
redundant data concentrator on global architectures.
 Quadruple Modular Redundant (QMR) (4 CPU, 4 Communication modules..)
 Online modification without the need to shutdown the system
 More precision for analog input (100 times more accurate than HIMATRIX)
example: HIMATRIX AI from 0 to 2000 and HIMAX from 0 to 200 000
 It has more diagnostic capabilities.
 It has all the marshalling features.
 Redundant FTA (Field Terminal Assembly).

HIMAX MODULES
Digital Input Modules
X-DI 32 01
X-DI 32 02 (for proximity switches: CAPACITIVE PROXIMITY SENSOR, INDUCTIVE PROXIMITY
SENSOR, MAGNETIC PROXIMITY SENSOR, OPTICAL PROXIMITY SENSOR, ULTRASONIC
PROXIMITY SENSOR.)
X-DI 32 04
X-DI 32 05 (for proximity switches)
X-DI 64 01
X-DI 32 03
X-DI 16 01
Analog Input Modules
X-AI 32 01 (4….20 mA)
X-AI 32 02 (4...20 mA)

Counter Module
X-CI 24 01 (0…20kHz)

Digital Output Modules


X-DO 24 01
X-DO 12 01 (relay output module) more expensive
X-DO 32 01
X-DO 24 02
X-DO 12 02

2. Communication protocols
SafeEthernet enables easy and efficient networking of HIMA safety systems in the widest
range of industrial and application fields.
- Certified protocols for use in safety related applications (up to SIL 3)
- Ethernet
- Identified by IP address and SRS ID

Note: you can’t upload a program from HIMA system. So


if you lost your program you can’t recover it
3. SILworX
SILworX allows you to program and configure your HIMA safety-related controllers and
diagnose errors in a friendly user interface. For HIMATRIX, HIQUAD and HIMAX.