Dhaka khulna (N8) Road Improvement Project

HQ,24 Engineer Construction Brigade ,Bangladesh Army.


Package-3

Consultant: Contractor:
HPCPDIL PDL-CAMCE-CR-24B= JV

Flakiness Index (BS-812)


Lab Ref. No. : Sample No. : 03

Source : India Date of sampling : 08.08.18

Description : 16 mm Pakur Stone Chips Date of testing : 12.08.18

Sample Location :Stackyard Purpose : Binder Course Mix Design

Wt. of sample : 4545 gm Sampled by : Jointly

Sieve Size
Test Weight (gm) Weight Passing (gm) % Flaky Remarks
(mm)

63.0-50.0
50.0-37.5
37.5-28.0
28.0-20.0
20.0-14.0 2527 620 24.54
14.0-10.0 1874 270 14.41
10.0-6.30 144 63 43.75
Total 4545 953 20.97

total weight passing thickness gauge x 100


Flakiness Index =
Total weight of test sample

= 20.97 % ≈ 21%

Technician Material Engineer Material Engineer Representative


Technician Consultant Consultant
Contractor Contractor HQ,24-ECB
Technician Material Engineer Material Engineer Representative
Technician Consultant Consultant
Contractor Contractor HQ,24-ECB
9.5mm 100 100

4.75mm 95 100
2.36mm 80 100
1.18mm 50 85
0.600mm 25 60
0.300mm 10 30
0.150mm 2 10
Dhaka khulna (N8) Road Improvement Project
HQ,24 Engineer Construction Brigade ,Bangladesh Army.
Package-3

Consultant: Contractor:
HPCPDIL PDL-CAMCE-CR-24B= JV

Flakiness Index (BS-812)


Lab Ref. No. : Sample No. : 02

Source : India Date of sampling : 08.08.18

Description : 20mm Pakur Stone Chips Date of testing : 11.08.18

Sample Location :Stackyard Purpose : Binder Course Mix Design

Wt. of sample : 4528 gm Sampled by : Jointly

Sieve Size
Test Weight (gm) Weight Passing (gm) % Flaky Remarks
(mm)

63.0-50.0
50.0-37.5
37.5-28.0
28.0-20.0
20.0-14.0 2510 410 16.33
14.0-10.0 1874 290 15.47
10.0-6.30 144 63 43.75
Total 4528 763 16.85

total weight passing thickness gauge x 100


Flakiness Index =
Total weight of test sample

= 16.85 % ≈ 17%

Technician Material Engineer Material Engineer Representative


Technician Consultant Consultant
Contractor Contractor HQ,24-ECB
Technician Material Engineer Material Engineer Representative
Technician Consultant Consultant
Contractor Contractor HQ,24-ECB
9.5mm 100 100

4.75mm 95 100
2.36mm 80 100
1.18mm 50 85
0.600mm 25 60
0.300mm 10 30
0.150mm 2 10
Dhaka khulna (N8) Road Improvement Project
HQ,24 Engineer Construction Brigade ,Bangladesh Army.
Package-3

Consultant: Contractor:
HPCPDIL PDL-CAMCE-CR-24B= JV

Flakiness Index (BS-812)


Lab Ref. No. : Sample No. : 04

Source : India Date of sampling : 08.08.18

Description : 10 mm Pakur Stone Chips Date of testing : 12.08.18

Sample Location :Stackyard Purpose : Binder Course Mix Design

Wt. of sample : 1383 gm Sampled by : Jointly

Sieve Size
Test Weight (gm) Weight Passing (gm) % Flaky Remarks
(mm)

63.0-50.0
50.0-37.5
37.5-28.0
28.0-20.0
20.0-14.0
14.0-10.0 783 80 10.22
10.0-6.30 600 140 23.33
Total 1383 220 15.91

total weight passing thickness gauge x 100


Flakiness Index =
Total weight of test sample

= 15.91 % ≈ 16%

Technician Material Engineer Material Engineer Representative


Technician Consultant Consultant
Contractor Contractor HQ,24-ECB
Technician Material Engineer Material Engineer Representative
Technician Consultant Consultant
Contractor Contractor HQ,24-ECB
9.5mm 100 100

4.75mm 95 100
2.36mm 80 100
1.18mm 50 85
0.600mm 25 60
0.300mm 10 30
0.150mm 2 10
Dhaka khulna (N8) Road Improvement Project
HQ,24 Engineer Construction Brigade ,Bangladesh Army.
Package-3

Consultant: Contractor:
HPCPDIL PDL-CAMCE-CR-24B= JV

Flakiness Index (BS-812)


Lab Ref. No. : Sample No. : 01

Source : India Date of sampling : 08.08.18

Description : 25mm Pakur Stone Chips Date of testing : 11.08.18

Sample Location :Stackyard Purpose : Binder Course Mix Design

Wt. of sample : 5257 gm Sampled by : Jointly

Sieve Size
Test Weight (gm) Weight Passing (gm) % Flaky Remarks
(mm)

63.0-50.0
50.0-37.5
37.5-28.0
28.0-20.0 1012 297 29.35
20.0-14.0 2527 410 16.22
14.0-10.0 1574 230 14.61
10.0-6.30 144 63 43.75
Total 5257 1000 19.02

total weight passing thickness gauge x 100


Flakiness Index =
Total weight of test sample

= 19.02 % ≈ 19%

Technician Material Engineer Material Engineer Representative


Technician Consultant Consultant
Contractor Contractor HQ,24-ECB
Technician Material Engineer Material Engineer Representative
Technician Consultant Consultant
Contractor Contractor HQ,24-ECB
9.5mm 100 100

4.75mm 95 100
2.36mm 80 100
1.18mm 50 85
0.600mm 25 60
0.300mm 10 30
0.150mm 2 10

You might also like