Solenoid Operated Valve: EP-08W-X-Y-Z-05

You might also like

Download as pdf or txt
Download as pdf or txt
You are on page 1of 1

SOLENOID OPERATED VALVE

(Pilot Operated)
(Poppet 2-Way Normally-Open Cartridge Style)
Ordering Code: EP-08W-X-Y-Z-05

2 2

Torque 2-3 Nm
1 1
M12x1.25

Coil EC-04W
85

TECHNICAL DATA
73
66

Max.Operating pressure: 350 bar


Rated flow: 40 l/min
24.0 Hex.

Locating
Cavity-Tooling: 08W-2
Shoulder 3/4"-16UNF-2A
Installation torque: 39 - 51 Nm
4
27.6

2 Weight: 0.13 kg
12.7
1
Internal Leakage Approximately:
UNIT:mm
0.15 cc/minute
Pressure Drop (3 drops/minute) max. at 350 bar
12
Pressure- P(bar)

10 Hydraulic Fluid Viscosity、Cleanliness、Temperature Level:


Please refer WINNER technical information.
8 ( T.101.101.E HYDRAULIC FLUID (A)VISCOSITY )
( T.101.102.E HYDRAULIC FLUID (B)CLEANLINESS )
6 ( T.101.103.E HYDRAULIC FLUID (C)TEMPERATURE )

②to
4
2 Minimum Voltage Required:
0 10 20 30 40 50 90 % of nominal
Flow-Q(l/min)
Coils must be ordered separately
200
Mounting Position: unrestricted
150
Time (ms)

Closing
100
X STRUCTURE
50
Opening 2 Ports、20 Watt. Coil
2A 12.7 mm tube
0 10 20 30 40 50
Flow-Q(l/min)
The performance curve or data is only for reference, as customers' using condition, pressure, flow, hydraulic fluid
viscosity, cleanliness, temperature and so on are different, the curve or data will be different.

Y OPERATION Z OPTIONS
Normally-Open N Non-adjustable
02 No Reverse Flow De-energized
In de-energized condition, this valve is allowed flow from port ② to port ① P Push Style
but it’s difficult to pass that flow from port ① to port ②.
Manual Override
This valve is similar to check valve when energized. Allow free flow from
Push and Twist Style
port ① to port ② and block flow from port ② to port ①. T Manual Override
If you need bi-directional flow, please refer Y=06.
Rev.221004 D.102.104.E

You might also like