Dropped Curbs

• Dropped curbs should be provided at


BATAS PAMBANSA BLG. 344 DISCLAIMER:
A. Outside and Around walkways with changes in elevations

Buildings
Always double-check the values given in this document with
the actual laws. For corrections or clarifications, email
• Should be provided at pedestrian
crossings and at end of footpaths
Accessibility Law
arch.pedrosantosjr@gmail.com.
• Should be as wide as the crossing or
should be 900mm wide at minimum

Dropped Curbs Dropped Curbs Dropped Curbs Curb Cut-outs


• Shall be ramped towards adjoining curbs • Curb cut-outs should only be allowed
with a gradient not more than 1:12 when it will not obstruct or lessen the
• Shall be sloped towards the road with a width of a walkway
maximum cross gradient of 1:20 • Minimum width should be 900mm
• The lowest point of the curb should not • Should have a gradient not more than 1:12
exceed 25mm height above the road/gutter

Curb Cut-outs Walkways Walkways Walkways


• Walkways should be kept as level as • Should not have abrupt pitches in angle or
possible and provided with slip-resistant interruptions by cracks that create edges
material above 6.5mm
• Minimum width is at 1200mm • Grating openings at walkways should
• Should have a gradient no more than 1:20 have max dimension of 13x13mm and
or 5% (1:100 max cross gradient) shall not project more than 6.5mm

Walkways Walkways Walkways Walkways


• In lengthy walkways, wheelchair rest
stops or turning spaces with minimum
dimension of 1500mm should be provided
(maximum distance of 12 meters between
stops)
• Straight forward routes with right angle
turns should be observed for the blind
Walkways Walkways Handrails Handrails
• Regular maintenance of the plantings • Handrails should be installed at both sides
adjacent to the walkway is needed to of ramps and stairs and at the outer edges
avoid overgrowth and obstruction of dropped curbs at crossings
• Walkway headroom shall not be less than • Shall be installed at 900mm and 700mm
2 meters
above steps or ramps ( Height at 1 or 1.06
• Passageway for the disabled should not be meters if for protection at great heights)
obstructed by furniture, bollards, etc

Handrails Handrails Open Spaces Open Spaces


• 300mm long extension of handrail should • Where open spaces are provided, give
be provided at start and end of ramps and walkways defined edges either by the use
stairs of planters with dwarf walls, grass verge
• Hand grips should be 30 to 50mm wide or similar which provides a texture
• If attached to walls or ledges it should different from the path. This helps the
have a minimum clearance of 50mm from blind to determine the pathway.
the wall or 40mm from the ledge

Signage Signage Signage Signage


• Directional and informational sign should A. Access Symbol B. Phone C. Elevator D. Parking E. Ramp

be located at points conveniently seen Sign Size (cm) Usage


even by a person on a wheelchair A 10x10 Toilets, stall doors
• Should be kept simple and easy to A,B,C,D 15x15 With or without directional arrows
understand, should be made of A,B,C 22x22 With or without arrows
contrasting colors and gray values to A,B,C,D,E 30x30 For exterior use

make detection and reading easy A,B,C,D,E 60x60 For exterior use
F 20x60 For exterior use

Signage Signage Signage Crossings


• Should a sign protrude into a walkway, it • Labeling public areas should have • To reduce the exposure time to vehicular
should have a min. headroom of 2 meters embossed symbols with min. height of traffic, all at grade crossing should:
• On walls and doors, it should be located at 1mm (Braille should also be included) – Be perpendicular to the carriageway
max. height of 1.60 meters and a min. • Text on signboards shall be of dimension – Be located at the narrowest part of the road
height of 1.40 meters that people with less than normal visual – Have central refuges of at least 1.5 m deep and
acuity can read at a certain distance preferably 2 m, where the width of road to be
crossed exceeds 10 m.
Crossings Crossings Crossings Crossings
• Provide tactile blocks in the immediate • Light controlled crossings and audible
vicinity of crossings as an aid to the blind, signals are best for the disabled
should be high enough to be felt but low • Audible signals should be distinguishable
enough to not cause tripping like in indicating end of crossing time
• Brushed or grooved concrete have not • A min. of 6 seconds crossing period or
proved successful as tactile strips crossing distance times 0.9 m/sec crossing
speed, whichever is greater should be used

Parking Areas Parking Areas Parking Areas


• Accessible parking slots should have a • Walkways from accessible spaces of 1.2 m
minimum width of 3.70m clear width shall be provided between
B. Parking • Should be close as possible to building or front ends of parked cars
accessible entrances and should be • Signs or markings for the handicapped
perpendicular or at an angle to the road or parking should be provided
circulation areas • Should never be located at sloping areas

Entrace Entrace Entrace


• At least 1 entrance to every building
C. Inside Buildings and should be accessible from arrival and
departure points to the interior lobby (1
Structures entrance should have elevator access)
• Entrance with vestibules shall be provided
a level area with at least 1.8m depth and a
1.5m width

Ramps Ramps Ramps Ramps


• Change in elevation require a ramp except • Ramps exceeding 6 meters whose gradient • Shall be equipped with curbs on both sides
when served by a dropped curb, an is 1:12 shall be provided with landings not with a minimum height of 100mm
elevator or other mechanical device less than 1.5m • Ramp with a rise greater than 200mm and
• Provide 1.2m clear width with 1:12 max • Level areas not less than 1.8m should be leads down towards a vehicular area,
gradient provided at the top and bottom should have a railing across the full width
• Length of the ramp should not exceed 6 • Handrails will be provided on both sides at of its lower end not less than 1.5m from
meter if the gradient is 1:12 700mm and 900mm from the ramp level the foot of the ramp
Ramps Doors Doors Doors
• 800mm minimum clear width for doors • Minimum clear level space of 1.5x1.5m
(measured between surface of the fully shall be provided before and extending
open door at the hinge and the door jamb beyond a door (Exception: Where a door
at the stop) shall open onto but not into a corridor, the
• Should be operable by force not more than required clear level space on the corridor
4 kg (closing device pressure shall not side of the door may be a minimum of
exceed 1 kg) 1.2m corridor width

Doors Doors Doors Doors


• Out swinging doors should be provided at • Vertical pull handles centered at 1.06m
storage room, closets and PWD toilet stall above the floor are preferred to horizontal
• Latching or non-latching, hardware should pull bars for all doors
not require wrist or fine finger actions • Doors along major circulation routes
• Doorknobs and other hardware should be should be provided with kick plates at a
located between 0.82m and 1.06m above height of 300mm to 400mm
the floor (900mm is preferred)

Thresholds Switches Switches Corridors


• Thresholds and sliding door tracks shall • Manual switches shall be positioned • 1.2 meter minimum clear width for
have a maximum height of 25mm and within 1.2m to 1.3m above the floor corridors (Shall have no obstruction)
preferably ramped • Manual switches shall be located no • Turnabout spaces with minimum area of
further than 200mm from the latch side of 1.5x1.5 m and spaced at a maximum of 12
the door m shall be provided for wheelchair passes
and turning around of wheelchairs

Corridors Corridors Washrooms & Toilets Washrooms & Toilets


• Turnabout spaces should also be provided • 1.7 x 1.8 meters minimum dimension for • A turning space of 2.25 sqm with a min.
at or within 3.5m of every dead-end accessible toilets dimension of 1.5m for wheelchairs shall be
• As in walkways, corridors should be • 1 movable grab bar and 1 fixed to the provided outside water closet stalls
maintained level and provided with slip adjacent wall shall be installed at the • Minimum of 1 accessible water closets on
resistant surface accessible water closet stall for lateral each floor level (or on that part of a floor
mounting, fixed grab bars on both sides for accessible to the PWD) where the total
frontal mounting number of water closets per sex is 20
Washrooms & Toilets Washrooms & Toilets Washrooms & Toilets Washrooms & Toilets
• Minimum of 2 accessible water closets on • Maximum height of lavatories should be
each floor level (or on that part of a floor 800mm with a knee recess of 600-700mm
accessible to the PWD) where the total vertical clearance and a 500mm depth
number of water closets per sex exceed 20 • Urinals should have elongated lip or
• Max height of water closet should be should be trough-type, the maximum
450mm, flush control should have a max height of the lip should be 480mm
height of 1.2m

Washrooms & Toilets Washrooms & Toilets Washrooms & Toilets Stairs
• Signage of men’s washroom shall be an • Treads should be of slip-resistant material
equilateral triangle with a vertex pointing and edges of steps should be colored to be
upward (length of sides should be 300mm) easily seen
• Signage of women’s washroom shall be a • Slanted nosing are preferred over
circle (diameter should be 300mm) protruding nosing to avoid feet getting
• Signage should at least be 7.5mm thick caught in the recessed areas (Open
stringer should be avoided)

Stairs Stairs Stairs Elevators


• A 300m wide tactile strip shall be • Accessible elevators should be located not
provided before hazardous areas such as more than 30 meters from the entrance
sudden change in elevation and at the top • Shall have a minimum dimension of 1.1 x
and bottom of stairs 1.4 meters
• Centerline height of topmost buttons shall
be between 0.9-1.2 m from the floor

Elevators Elevators Elevators Water Fountains


• Button sizes shall have a minimum • At least 1 fountain shall be provided for
diameter of 20mm with maximum every 2000 sqm of floor area and there
depression depth of 1mm shall not be less than 1 on each floor.
• If wall mounted, the max height shall be
850mm from the floor to the rim and shall
be push-button controlled
Public Telephones Public Telephones Places of Assembly
• Provide an unobstructed space of 1.5 x 1.5
m in front of the telephone unit
• Booth door openings should have a D. Safety
minimum clear width of 800mm with
either out swing, folding or sliding door
• Controls shall be located at a maximum
height of 1.1m above the floor

Fencing For Road & Foot Works Fencing For Road & Foot Works Fencing For Road & Foot Works Covers For Excavations
• All excavations must be protected or – Railing should incorporate tapping rails that
fenced-in, whatever type of fence used, it should not be greater than 350mm above the
is important that the railing should adjacent surface
incorporate the following features: – Fence should be strong enough to resist people
walking in to it and gaps between adjoining
– Height of the rail should be at least 1 m above
fences should not occur
the adjacent surface

Covers For Excavations Covers For Excavations Signages Signages

Signages